Similar documents
15 cm Reservoir Tubing. 210 cm Tubing

Compressor Nebulizer. Guidebook

Medescan Nebuliser Med - S600A Instructions Manual

Compressor Nebulizer. Guidebook

8/13/11. RSPT 1410 Humidity & Aerosol Therapy Part 3. Humidification Equipment. Aerosol Therapy

Anaesthetic and respiratory equipment Nebulizing systems and components

Nebulizers. Small Volume Nebulizers

Compressor Nebulizer System

Portable Equine Nebuliser System. User Manual

Using an Inhaler and Nebulizer

ISO INTERNATIONAL STANDARD. Anaesthetic and respiratory equipment Nebulizing systems and components

Continuous Aerosol Therapy

PORTABLE COMPRESSOR NEBULIZER Guidebook & Manual Reorder No. 5606

Day-to-day management of Tracheostomies & Laryngectomies

OG TAL ODUCT CA PR e e HEALTH

Effective Date: August 31, 2006 SUBJECT: CARE AND USE OF NEBULIZER AND INTERMITTENT POSITIVE PRESSURE BREATHING DEVICE

Pulmo Waves Device for respiratory physiotherapy

Selection and Optimization of the Sample Introduction System

1.40 Prevention of Nosocomial Pneumonia

Tropic plus ultrasonic nebulizer Consumables and Accessories

Section 2.1 Daily checks Humidification

1 2 3 Based on the contents detailed below, assess the substantial equivalence to a legally marketed predicate device. In that case, the standards, et

TOWN OF FAIRFIELD HEALTH DEPARTMENT PUBLIC HEALTH NURSING

I. Subject: Continuous Positive Airway Pressure CPAP by Continuous Flow Device

KOALA. Adult Bacterial Viral Filters. Medical Pty Ltd

Airway Clearance Devices

Saline (0.9%) Nebuliser Guideline

Allergy Reliever. User Manual. AR 1 Series

Aerosol Therapy. Aerosol Therapy. RSPT 1410 Humidity & Aerosol Therapy Part 4

Simple. Stress-free. The Newtron Ultrasonics Series

WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients.

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual

Small Volume Nebulizer Treatment (Hand-Held)

E L E C T R O N I C VA P O R I Z E R S. User Manual

Nebu 100s Series. Instruction Manual

Compressor Nebulizer. Model UN-014

Complex Care Hub Manual: Continuous Positive Airway Pressure (CPAP) Ventilation

INSTRUCTION MANUAL. Compressor Nebulizer System NE-C25

MESH NEBULIZER INSTRUCTION MANUAL. Model NE-U22

experiences that matter

WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients.

Respiratory Therapy. Medical/Scientific/General Background

Rhino Clear Sprint Atomizer

Manufacturer s information

EMERGENCY AIRWAY MANAGEMENT SOLUTIONS

Table of Contents. Introduction Indications For Use Contraindications Warnings Precautions...5

10/17/2016 OXYGEN DELIVERY: INDICATIONS AND USE OF EQUIPMENT COURSE OBJECTIVES COMMON CAUSES OF RESPIRATORY FAILURE

Xpert MTB/RIF Training. Indira Soundiram 2012

The essential principles of tracheostomy care

Smart asthma therapy. Patient information Spacer inhaling aid for metered-dose aerosol inhalers

Cough Assist. Information for patients, families and carers Therapy Services

This letter is to notify you of recent changes to the PULMOZYME product monograph. Please note, additions/changes have been highlighted in yellow.

Operating Room Equipment and Accessories

Charisma High-flow CPAP solution

Bilevel positive airway pressure (BPAP) non-invasive ventilation

Operating Instructions SaHoMa -II mobile ultrasonic nebulizer

OPTIMISING ANALYTICAL STRATEGIES FOR THE DEMONSTRATION OF BIOEQUIVALENCE IN A GENERIC NEBULISER

CRITICAL CARE AquaVENT

Latex Free. An affordable, easy to use, high density, small volume nebulizer with a breath enhanced design! Breath Enhanced High Density Jet Nebulizer

PREMIXES FOR MEDICATED FEEDING STUFFS FOR VETERINARY USE. Praeadmixta ad alimenta medicata ad usum veterinarium. Effervescent powders

NIV and Aerosoltherapy

YOURS POSITIVELY V100. No. 85 Suli Road. Wuzhong District, Suzhou. P.R. China

DEBSON TM2 OXYGEN THERAPY FLOWMETERS WITH PRE ADJUSTED FLOWRATES. English version 09/2015

Appendix M: Device Technique

Effects of Tube Depth and Infusion Rate of Continuous Humidification by Endotracheal Intubation on Humidification Effect

Anatomy & Physiology 2 Canale. Respiratory System: Exchange of Gases

Pediatrics in mechanical ventilation

DreamStation. Provider guide

Adult Patients Going Home with a Tracheostomy

PRODUCT TRAINING TREND II

Cleaning and Care Instructions

Mini-Mist. Owner s Manual. portable nebulizer. PMM241 Rev.3 12/10

Home Care ecatalog. When Your Care Is Critical. westmedinc.com

Emergency Medicine High Velocity Nasal Insufflation (Hi-VNI) VAPOTHERM POCKET GUIDE

Delivering Aerosol Medication in ICU

COMMITTEE FOR MEDICINAL PRODUCTS FOR HUMAN USE (CHMP) GUIDELINE ON THE PHARMACEUTICAL QUALITY OF INHALATION AND NASAL PRODUCTS

SONOPULS 490 SONOPULS 490

TIP NO AEROSOLIZED DRUGS TECHNICAL INFORMATION PAPER NO PURPOSE.

Chapter 10. The Respiratory System Exchange of Gases. Copyright 2009 Pearson Education, Inc.

Lumis Tx: the all-in-one hospital ventilation solution

Introducing Infant Flow Advance SIPAP. By Joanne Cookson March 2008

Head and Neck Oncology A guide to using your nebuliser Information for patients

CoughAssist E70. More than just a comfortable cough. Flexible therapy that brings more comfort to your patients airway clearance

Breezhaler. Open to see clear capsule. How do I use my Breezhaler? Care of my Breezhaler

Therapy options. snoring & obstructive sleep apnea. Mandibular advancement devices Nasal dilators Supine position preventers

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

Û mectron Air-Polishing

INSTRUCTIONS FOR USE AND CARE

Q. What are metered-dose inhalers? A. These are devices that dispense medicines directly into the lungs, in the form of a mist or aerosol in a

NI 60. Non-invasive ventilation without compromise. Homecare Pneumology Neonatology Anaesthesia. Sleep Diagnostics Service Patient Support

The Respiratory System Structures of the Respiratory System Structures of the Respiratory System Structures of the Respiratory System Nose Sinuses

Policy x.xxx. Issued: Artificial Airways and Airway Care. ABC Home Medical Company Policy & Procedure Manual. A. Tracheostomy Tubes ( trach tubes)

Pap Settings. A review of fine tuning settings For patient comfort and compliance Wendy Cook BSRT Judy Salisbury RPGST

Clearing the air.. How to assist and rescue neck breathing patients. Presented by: Don Hall MCD, CCC/SLP Sarah Markel RRT, MHA

Quick Start Guide. Venipuncture and Intramuscular Injection Training Arm

Tracheostomy discharge information. Information for community nurses, patients and carers

Unit 5 Humidity/Aerosol Generators

Tuesday, December 13, 16. Respiratory System

Transcription:

Ultrasonic Humidifiers and Nebulisers for Medical Institutions DP100 NF EN ISO 13485 0459

SYST AM DP100, a n Container Ê Stands upright : convenient for preparing the session. Ê With simple and quick connector. Ê Integrated protecting metal disc in the container for greater lifetime. Ê Electronic built into the housing for greater reliability. Ê Design ensures flow and evacuation of water even in cases of accidental infiltration, preventing any deterioration of the material. Flexible Ê Coated for improved decontamination. Ê Easy fixing. Universal Bottle Support Rod Ê Easy fixing. Ê Free rotation to 180 even after fixing. Suitable for different types of bottle and for different consumable configurations. :! More settings and new functionalities Adjustable nebulisation : 6 settings for nebulisation. Ventilation : 5 settings of intensity for direct humidification. + a boost level for indirect humidification. Integrated timer : for programming the duration of the session. Keyboard locking button to avoid any unintended moves. Automatic memory of the settings of the previous session. Adjustable temperature of the heater. Fitted with an intelligent alarm system By dysfunctions, the DP100+ shows the source of the problem with indicators : Mist-heater alarm Ventilation alarm Water level in the container (too low or too high)

ew generation device safe simple efficient Design Ê Housing completely water repellent and watertight thanks to its design : the slopes and flow circuits avoid stagnation of liquid thus protecting the electronic components for added reliability and safety. Ê Removable ventilator without tools allows a perfect decontamination of air circuits. Ê No heat discharge on the surface of the casing. Ê Slopes provide flow. Ê A protecting visard at the back provides protection for the connections. In addition, 2 innovative functionalities are included in the alarm detection system : PATENTED Detection system in the nebulisation chamber Ê Automatic stop of the device at the end of the session when the nebulisation chamber is empty: facility and time saving for the nursing staff who do not need to supervise the end of the session, to switch off the device in time with risks of damaged consumable (deteriorated chamber). Ê Also detects an exceptionally high water level in the chamber (in the event of incorrect settings). The management of the service life of the quartz Ê The device analyses and indicates a quartz whose end of service life is close. The functioning of the device is not at this stage blocked. This gives time to technicians to make the replacement. Ê When the quartz is totally outworn the device will stop.

Aerosol Therapy (medicinal or humidifying) ULTRASONIC DEFINITION OF AEROSOL THERAPY Ê An aerosol is a suspension of solid or liquid particles in a gas or a gas mixture (e.g. air). In the application of medicinal aerosol therapy this aerosol is a spray of medication for inhalation by the patient. In the humidifying application the particles produced are droplets of water. OPERATING PRINCIPLES OF ULTRASONIC TECHNOLOGY Ê Under the action of an oscillator the quartz located at the base of the container is subjected to very high frequency vibrations producing the effect of ultrasound (waves). Ê These waves travel through the liquid up to the surface of the solution producing a liquid film of very fine droplets (cavitation process). Ê The size of the particles thus formed is proportional to the length of the quartz wave (fixed for each unit) but the nebulisation density (= quantity of particles produced or output) can be modified by varying the amplitude of the quartz. Ventilated or inhaled air Aerosol towards the patient Medication cup filled with water (humidification) or with medication(nebulisation) Container filled with water conducting the waves Vibrating quartz emitting the waves TECHNICAL CHARACTERISTICS DP100 Generator features - Quartz frequency : 2,4 Mhz - Ventilation for use by patients both active and inactive Characteristics of the particles to norm NF-EN 13544-1 (NaF 1% - filled volume 4ml) - MMAD (measure by Malvern optical laser diffraction) = 4,2 µm - Output liquid aerosol produced : 0,19 ml/min - Quantity of produced aerosol (inhalable volume) : 1,36 ml - Delivered fraction (inhaled) : 34% - 71% of the particles < 5 µm Nebulisation capacity - In aerosol therapy : 2 to 8 ml with Control Dose / 8 to 30 without Control Dose - In humidification universal bottle supply system - Dead volume : ±0,6 ml Other - Meets electrical safety norms and CEM NF EN 60601-1 & 60601-2 - Available accessories (supplied separately) : mist-heater, water trap, rolling stand, consummable.

The DP100 for aerosoltherapy ADVANTAGES OF AEROSOLTHERAPY IN RAPPORT TO THE ADMINISTRATION OF MEDICATION BY MOUTH Ê The aerosol reaches directly the targeted organ, thus providing much greater treatment efficiency. Ê Good bio-availability at the bronchial epithelium. Ê Requires less medication doses. Ê Low systemic absorbtion : reduction of side effects. INDICATIONS Ê Asthma, cystic fibrosis, bronchial pneumonia, COPD, bronchiolitis, winter ailments, ENT ailments, sinusitis, rhinitis... SYST AM CONSUMABLE FOR AEROSOLTHERAPY FOR USE WITH THE DP100 Adult/adolescent set Ref. 2901H Pediatric set (1 to 10 years) Ref. 2901NH Infant set Ref. 2901BBH + Adult/adolescent mask Mouth piece with valved mask Pediatric mask Infant mask Air inlet Medication particles outlet THE CONTROL DOSE PATENTED SYSTEM : A SYST A M INNOVATION PATENTED Medication cup Control Dose Particle production area Medicinal solution Ê Reduces dead volume thereby limiting the dilution of the medication. Ê Shorter session. Ê Maximised inhaled fraction. Controlled dosage Ê Enables the nebulisation of very small quantities of medication (from 2 to 8 ml) without dilution. Ê Allows nebulisation with a residual volume of 0,6 ml. In operation the medicinal solution remains within the volume created by the Control Dose and the medication particles produced are carried to the patient. Controlled time! Ê Reduces the length of the aerosol therapy session. Ê Therefore reduces the patient participation (particularly for young children). Ê Thus guarantees better treatment control.

The DP100 as a humidifier WHY HUMIDIFY? Ê Humidification becomes necessary due the dry nature of compressed gases used in hospital (oxygen therapy). It avoids the drying out of the bronchial mucosa and at the same time fluidising the expectorations in the event of bronco-pulmonary infection. Ê In normal time the upper airways provide the warming and humidification of the inhaled air. Also they retain the warmth and humidity contained in exhaled air. In the case of ventilated patients under anaesthetic (with tracheal probe) or tracheotomies the upper airways are no longer able to function. Prolonged exposure to dry compressed gasses can bring harmful effects including a localised inflammation in the trachea, a reduction in the ciliary function, a reduction in secretions, a lowering of body temperature, a reduction in the function of the cardio-pulmonary, an increased risk of a blockage in the tracheotomy tube... Ê Humidification is mainly obtained in the hospital environment by the production of aerosols (sprays, micro-droplets) from an ultrasonic nebuliser providing particles from 0,5 to 6 µm, optimal size for reaching both the tracheobronchial and the cavities. Ê It may also be preferable, for patient comfort, to warm the compressed gasses prior to a humidification sessions... INDICATIONS Ê Tracheotomy, tracheostomy Ê Trauma, palliative care Ê Neonatology, bronchiolitis Ê Bronchio-pulmonary infections... SYST AM CONSUMABLE FOR HUMIDIFICATION FOR USE WITH THE DP100 Closed humidification sets, Open humidification set, For bottles with puncture cap : Ref. 2901HUPN For bottles with screw-top : Ref. 2901HUVN For tracheotomy with bottles with screw-top : Ref. 2901HUVNT For bottles with screw-top : Ref. 2901HOV

THE BENEFITS OF A SINGLE-PATIENT CLOSED SYSTEM HAVING NO DIRECT CONTACT WITH THE DEVICE (2901HUVN, 2901HUPN, 2901HUVNT) Systems with an open respiratory circuit present potential contamination risks. The single-patient closed consumable prevents all hand-carried contamination risks, stops the infiltration of pathogenic agents and thus contributes to improving patient s quality of treatment. Controlled hygiene Ê Limitation of contamination Ê Closed breathing circuit without contact with the device. Universal system can be used with most bottles types Ê Distilled sterile water or isotonic sterile solutions (500 ml or 1000 ml screw thread or puncture top) Ê Stock s handling and purchasing are simplified Ê Easy installation and use for nursing staff. Overall improves quality of care in institutions through : Ê Time saving Ê Greater patient safety Ê Lower daily treatment cost Ê Capacity of nebulising during a humidification session. Distilled water or isotonic sterile solution Protecting caps to be removed before use to avoid hand carried contamination. Aerosol towards the patient Air inlet Closed inhalation circuit, No direct contact with the device Nebulisation chamber Can also be used for aerosol therapy during a humidification session

Accessories also make a new start THE MIST HEATER (Humidification) Easy to clean and disinfect : Ê Device cleanable by soaking Ê Large diameter stainless steel tube providing access for cleaning and meticulous drying. Better operating : Ê No water remaining inside the device. Ê No blockages New functionality : Ê Temperature control (three levels) providing greater comfort for the patient Increased Security : Ê Protectors avoiding contacts whith the heated surface during handling. Ê Requires less heating power for an equal functionality. Ê Design to minimise the formation of droplets. ROLLING STAND Ê Adjustable height to better adapt to different situations (beds, Alzheimer, incubators, etc...) Ê Tray designed to facilitate preparation of the session and to store accessories. Easily cleanable and decontaminable. Ê Fitted with braking system. Ê Clip board for personalising the proper use protocol. Oxygen nuzzle storage BACK Maximum height : 93 cm Minimum height : 55 cm Mist heater storage Consumables storage Preparation tray FRONT Connect With Us