PERSONNEL PREPARATION PROTOCOLS PERFORMANCE OPTIMIZING CT IMAGING IN CHILDREN

Similar documents
CT Radiation Risks and Dose Reduction

Managing Radiation Risk in Pediatric CT Imaging

Debra Pennington, MD Director of Imaging Dell Children s Medical Center

Why is CT Dose of Interest?

Translating Protocols Across Patient Size: Babies to Bariatric

Radiation Dose Reduction: Should You Use a Bismuth Breast Shield?

Radiation Dose Reduction Strategies in Coronary CT Angiography

Accounting for Imaging Dose

Customizing Contrast Injection for Body MDCT: Algorithmic Approach

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

X-Ray & CT Physics / Clinical CT

3/5/2015. Don t Electrocute Me!: Common Misconceptions in Imaging and Radiation Safety (and What to Do About Them)

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell

(Non-EKG Gated) CTA Thoracic Aorta = CTA Chest

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

B. CT protocols for the spine

The Computed Tomography Examination

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

STRUCTURED EDUCATION REQUIREMENTS EFFECTIVE: JANUARY 1, 2016

Chief Radiographer TEI Clinical Associate 2016

Hi RES Extremity - (04/18/2011) CTDI: ~13 mgy per acquisition Used for evaluation of: Ankle Elbow Hand Wrist Foot /Calcaneous Toes Fingers

CT Dose Estimation. John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology. University of California Davis Medical Center

CHEST CT PROTOCOL FOR MULTIPLE DETECTOR ROW SCANNERS

CTA Pulmonary Embolism CTA Chest W (arterial)

Cardiac CT Techniques in Neonates (and infants)

CTA Chest Pulmonary Embolism & Routine CT Abdomen + Pelvis W CTA Chest W (arterial) & CT Abdomen + Pelvis W (venous)

Low Dose Era in Cardiac CT

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION

Ultralow Dose Chest CT with MBIR

Introduction Pediatric malignancies Changing trends & Radiation burden Radiation exposure from PET/CT Image gently PET & CT modification - PET/CT

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

A comparison of radiation doses from modern multi-slice Computed Tomography angiography and conventional diagnostic Angiography:

HI-Res Extremity Sensation 16

EXAMINATION CONTENT SPECIFICATIONS ARRT BOARD APPROVED: JANUARY 2017 IMPLEMENTATION DATE: JULY 1, 2017

The radiation dose in retrospective

Computed Tomography (CT) - Chest

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

STRUCTURED EDUCATION REQUIREMENTS IMPLEMENTATION DATE: JULY 1, 2017

To Shield or Not to Shield? Lincoln L. Berland, M.D.

Managing Patient Dose in Computed Tomography (CT)

Radiation Dosimetry for CT Protocols

Computed tomography. Department of Radiology, University Medical School, Szeged

Paediatric Dose Reduction and Image Quality

Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer

created by high-voltage devices Examples include medical and dental x-rays, light, microwaves and nuclear energy

Radiation Exposure in Pregnancy. John R. Mayo UNIVERSITY OF BRITISH COLUMBIA

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

Computed Tomography (CT) - Chest

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

CT angiography techniques. Boot camp

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Aquilion ONE: Pediatric Imaging. Richard Mather, PhD. Senior Manager, CT Clinical Science Toshiba America Medical Systems, Inc.

THE TUFFEST STUFF CT REGISTRY REVIEW Live Lecture Seminar SATURDAY CURRICULUM

Cardiac Imaging Tests

Ask EuroSafe Imaging. Tips & Tricks. Paediatric Imaging Working Group. Shielding in pediatric CT

Doses from Cervical Spine Computed Tomography (CT) examinations in the UK. John Holroyd and Sue Edyvean

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Tracking Doses in the Pediatric Population

CT Low Dose Lung Cancer Screening. Part I. Journey to LDCT LCS Program

Outline. Lifetime Attributable Risk 10 mgy in 100,000 exposed persons (BEIR VII 2006) SPECT/CT and PET/CT Dosimetry

How do the Parameters affect Image Quality and Dose for Abdominal CT? Image Review

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Overview of Medical Diagnostic and Interventional Imaging: Usage Patterns

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

Radiation Dose in Pediatric Imaging

Survey of patients CT radiation dose in Jiangsu Province

Computed Tomography (CT) - Body

Vascular CT Protocols

Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology

Computed Tomography (CT) - Body

HONG KONG COLLEGE OF RADIOLOGISTS. Higher Training (Radiology) Subspecialty Training in Computed Tomography

Computed Tomography (CT) - Sinuses

Outline. NCRP Scientific Committee 6-2

Computed Tomography (CT) - Abdomen and Pelvis

Combined Anatomical and Functional Imaging with Revolution * CT

JUSTIFICATION PROTOCOLS FOR CT SCANNING ALBURY WODONGA HEALTH WODONGA CAMPUS

Pediatric chest HRCT using the idose 4 Hybrid Iterative Reconstruction Algorithm: Which idose level to choose?

Austin Radiological Association Nuclear Medicine Procedure PET SODIUM FLUORIDE BONE SCAN (F-18 NaF)

VASCULAR RINGS A CASE - BASED REVIEW

Ask EuroSafe Imaging. Tips & Tricks. CT Working Group. Optimization of scan length to reduce CT radiation dose

8/1/2017. Financial Disclosures. Dose Tracking at MGH. How Dose Tracking Affected Protocol Optimization in a Tertiary Quaternary Healthcare Center

CT Pancreas 3 Phase CT Abdomen WO W - NC.A.V

CT: Common Protocols. Michael Steigner, M.D. Director, Vascular CT/MR Assistant Professor of Radiology

Computed Tomography (CT) - Head

Justification, Optimization and Communication in Pediatric CT Imaging: Recent Improvements and Persistent Challenges Designated Emphasis in Nuclear

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

Liver 4 Phase CT Abdomen WO W - NC.A.V.D

RAMPS-GNYCHPS 2010 Spring Symposium New York, NY, April 30, Error Prevention and Patient Safety for Radiation Treatment and Diagnosis

The Increasing Use of CT and Its Risks

Patient / Organ Dose in CT

ADI Procedure Codes. August 2016 Revised April 2017 Page 1 of 7 ADI Procedure Codes

Dual-Energy CT: The Technological Approaches

FDG-18 PET/CT - radiation dose and dose-reduction strategy

PULMONARY EMBOLISM ANGIOCT (CTA) ASSESSMENT OF VASCULAR OCCLUSION EXTENT AND LOCALIZATION OF EMBOLI 1. BACKGROUND

Cardiac CTA without and with IV Contrast

Effective Utilization of Imaging. John V. Roberts, M.D. Premier Radiology Abdominal Imaging

After the Chest X-Ray:

Transcription:

OPTIMIZING CT IMAGING IN CHILDREN OPTIMIZING CT IMAGING IN CHILDREN BEVERLEY NEWMAN, BSc. MB.Bch. FACR Associate Professor of Radiology Stanford University and Lucile Packard Children s Hospital Personnel Preparation Protocol Performance Postprocessing Interpretation and Communication PERSONNEL Schedulers knowledgeable, facilitative access for consultation Child Life preparation/distraction Nurses adept at dealing with children/parents, assessing ability to cooperate, need for sedation, IV access and monitoring Anesthesiologists understand levelof sedation needed, prevention of atelectasis in chest CT, lung recruitment, breathold techniques CT Technologists skilled in handling/restraining children, know the equipment and appropriate protocols for age and indication, understand and use dose saving measures Radiologists knowledgeable about appropriate indications, correct protocol, equipment and dose saving capabilities, skilled interpretation of pediatric diseases PREPARATION Clinical information /correct study Protocol Cooperation/sedation/anesthesia Realistic expectations Child life help, distraction aids Oral contrast IV access plan for site, type of contrast, volume, method and speed of delivery, saline chaser PROTOCOLS First study versus followup High detail, lower detail options resolution needed dd Standard CT vs CT angiography spatial and contrast resolution interplay Contrast IV and/or oral IV access type and speed PERFORMANCE Scanner/room distractors Efficient Proper positioning Swaddling, reassurance, comfort, parent Protection leadapron apron, thyroidshields for nurse, anesthetist, parent? patient,thyroid,breast shield Nurse/physician in scanner to monitor contrast injection Follow protocol of scan including parameters, contrast delivery and scan delays Rapid scan quality check 1

18 m / boy gross patient motion 2yo M Neuroblastoma- difficult to 2007 compare serial nonuniform studies 2008 POSTPROCESSING Source images and various reconstructions along with protocol page sent to PACS Chest CT Routine reconstructions include: 1. Axial 3 5mm soft tissue algorithm(b30) 2. Axial 2mm lung algorithm (B60) 3. Axial MIPS 5 8mm thick 3 5mm apart 4. Coronal MPR 2mm (B45) 5. Sagittal MPR 2mm (B45) 6. Postprocessing interaction with data on 3D workstation with additional MIPS, MINIPS, CPR, 3D volumetric reconstructions and saved images as appropriate INTERPRETATION AND COMMUNICATION View multiple windows ( soft tissue, lung, bone) and planes (axial, coronal, sagittal). Interact with data on 3D workstation as needed Document technique, dose indices and findings Dictationto to includedescription description of positive and pertinent negative findings. Impression review and give opininion/conclusion of important findings Documentation of any problems e.g. contrast reaction, IV infiltration and their management Prompt communication of results. Direct communication of critical results OPTIMIZING CT IMAGING IN CHILDREN Personnel Preparation PROTOCOL PERFORMANCE Postprocessing Interpretation and Communication Multiple Chest CT Protocols Gap HRCT 1mm thick 5 10mm intervals, noncontrast detail of lung parenchyma/interstitium, Individual axial slices may require more than one breathold Inspiratory/expiratory, large areas not covered 100kVp, 30 80mAs lower dose about 50 70% less than routine chest CT dose. Routine spiral Chest CT 3 5mm contrast CT (3 5secs) protocol varies with age/weight; 80 100kVp, ref mas 55, pitch1 start study approx. 30secs into contrast injection dose ~2mSv can do lower dose or limited followup dose ~2mSv, can do lower dose or limited followup CTA for vascular detail 1mm thick spiral triggered study( 4 sec delay) with rapid dynamic IV contrast 80 100kVp, ref mas 100 150 dose ~50% more than routine contrast chest CT Gated CTA cardiac, small moving vessels e.g. coronaries.75mm, multiple slices throughout the cardiac cycle at each level 80 100kVp, ref mas 550 dose 3 4X routine chest CT with current retrospective gating Volumetric chest CT.6mm/ 50% overlap 100 kvp, 30 60mAs pitch 1inspiratory, expiratory 1.2 dose 20 30% higher than routine spiral 2

Contrast for Pediatric CT Chest: Noncontrast vs Contrast Children have little body fat and poor natural tissue contrast IV contrast (2cc/Kg) almost always desirable for body CT unless specifically contraindicated e.g. renal dysfunction ( Creatinine clearance < Oral contrast usually desirable for abdominal CT except for CT angiography and some emergencies. Usually some better than none Occasionally need rectal contrast 15mos noncontrast Incr. Creatinine 6mos SVC obstruction hand injection PICC 1do with PTX, PIE, IAA, Scimitar 2CT s same day NON CON CT.7mSv CTA 2.2mSv Pediatric Radiology Peripheral and Central IV Access Guide Contrast Dose: CT 2 3cc/Kg Study Purple PICC and purple Mediport power needle access - confirm tip location All other PICCs, ports and central lines3-4fr confirm tip, blood return, easy flush 18-20 g up to 6cc/sec 22 g ~2-3cc/sec 24 g 1-2cc/sec *OK<10Kg Injection Power Hand Power Power Power limits Method Hand Hand Hand 1-1.5cc/sec PSI 120 or Hand CT head/neck Acceptable Acceptable Acceptable Acceptable Suboptimal * CT chest Acceptable Acceptable Acceptable Acceptable Suboptimal * (alone) CT abd/pelvis Acceptable Very suboptimal CT angio/cardiac/ head & neck Acceptable Acceptable Very suboptimal * Acceptable Unacceptable Acceptable Suboptimal Very suboptimal * Abdomen Kidneys/Liver 3yoF Wilm s RVT and mets Mediport Hand Injection 15mos noncontrast renal dysfunction Good peripheral IV injector 12yoF RT. pyelonephritis 12/4/09 Rt arm peripheral IV injector 1/15/10 Mediport hand injection Suboptimal contrast IV infiltrated 3

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. 24-11-10 IMAGING USING IONIZING RADIATION IS AN ESSENTIAL PART OF MODERN MEDICAL MANAGEMENT ALARA PRINCIPLE Radiation Dose Should be As Low As Reasonably Achievable. www.imagegently.com IONIZING RADIATION MEDICAL IMAGING IS RESPONSIBLE FOR APPROXIMATELY 40 50% OF POPULATION RADIATION EXPOSURE IN THE U.S. 62 MILLION STUDIES/YR CTACCOUNTS FOR 17% OFMEDICAL IMAGING BUT 75% OF MEDICAL RADIATION. ONE CT = ABOUT 100 150 CXR S 11% OF CT SCANS ARE IN CHILDREN IONIZING RADIATION AND CANCER CONCERN FOR CANCER INDUCTION BY IONIZING RADIATION small risk, 1 in 1,000 1in 2,000 for 1CT(10mSv) =.05%. Lifetime cancer risk for population overall (40%) Children, especially infants, female>male have greater organ sensitivity to radiation (breast, thyroid, gonads) Increased organ dose in children because of less peripheral tissue to attenuate the Xray beam Cancer risk is cumulative with multiple exposures Longer lifetime for radiation effects to manifest Pierce et al Rad Res 154 pg 183: 2000 Effective Dose Estimates for a 5 year old child ective Dose (msv) Effe 12 10 8 6 4 2 0 CXR SXR Pelvis XR VCUG DMSA CT Head CT Chest Bon e Scan CT Abdo/Pelvis CT NCAP Annual background radiation (3 msv) S) CXR days L/S spine XR months GI/GU fluoroscopy months Nuclear Med mths / 1 2 yrs CT (mths) / 1 5 yrs Hall Pediatric Radiology Apr 2002 pg 226 Karen Thomas Hospital for Sick Children, Toronto 4

Approximate Medical Radiation Doses and chest Xray equivalents CXR msv Equivalents in a 5 year-old child in msv 3-view ankle.0015 1/14 th 2-view chest.02 1 Tc-99m radionuclide gastric emptying.06 3 Tc-99m radionuclide cystogram.18 9 Tc-99m radionuclide bone scan up to 6.2 310 FDG PET 15.3 765 Fluoroscopic cystogram.33 16 Upper GI 3 150 Contrast Enema 7 350 Chest C up to 3 150 Abdomen C up to 5 250 Effective Dose (ED) It is a radiation dose quantity It is a computation based on: Organ dose and radiosensitivity Weighting factors It is not a risk number Airline passenger (coast to coast R/T).03 Flight crew / attendants/yr 1.6 1.5 80 Huda, W Pediatric Radiology 2002: 32; 272 279 CTDIvol and DLP from Scanner NOT the actual dose the child receives CTDIvol = weighted CTdose index/pitch Reflects the average dose through a 16cm (head) or 32cm (body) plexiglas phantom with central dose weighted by 1/3 and peripheral dose 2/3 Dose length product(dlp)=ctdivol x scan length CTDIvol referenced to 16cm phantom( head ) 2x CTDIvol referenced to 32 cm phantom(body). Convert pediatric body DLP by 2X multiplication so dose referenced to 16cm phantom ED DLP METHOD Scanner generated CT dose index ( CTDI) and Dose length product (DLP) 3.4 YO 14.2Kg F routine chest CT 80kVp ; ref mas 55; mean mas 122 CTDI vol 2.21. Conversion to 16cm phantom (x2) = 4.42 DLP = CTDIvol x scan length = 43 (16 cm conversion =86) ED for Chest CT DLP METHOD Scanner DLP multiplied by an age based pediatric correction factor <1.039 Disadvantages: Correction factors for 120kVp Correction NOT scanner specific Large age/size range <5.026 <10.018 <15.013 Adult.014 3.4YO F DLP of 86; ED = 86x.026 = 2.23 msv Shrimpton PC et al 2006 BJR 79:968 Updated Chest DLP Conversion Factors ( based on Radiation Protection Publication 103 updated organ radiosensitivity) < 1yr.057 <5yrs.038 <10yrs.026 <15yrs.019 adult.02 3.4YO F DLP of 86; ED = 86x.038 = 3.26 msv kvp correction about 4% decrease per 10kVp drop (120 to 80kVp =16% decrease = 2.74mSv) Alessio calculation 2.2mSv Alessio AM, Phillips GS. A pediatric CT dose and risk estimator. Pediatr Radiol 2010; 40; 1816 5

Optimization of benefit/risk ratio Appropriate to do exam Appropriate p timing of exam Appropriate modality Get clinician/radiologist together Technologist APPENDICITIS CT is a digital technology, unlike radiographs, excessive radiation dose does not produce overexposed or poor quality images 40 to 80% reduction of typical adult CT doses still produces high quality diagnostic scans in children and young adults CT DOSE and REDUCTION STRATEGIES CT vendor related MDCT > radiation Overranging region above and below prescribed scan are exposed to radiation, can contribute 10% increase to dose. Therefore try and do multiple contiguousparts as singlesweepesweep e.g. CAP auto MA and automodulation of MA (changing MA during scan based on tissue thickness/density). Choose high detail option( lower noise index or higher ref mas) increased dose Many newer scanners provide some suggested pediatric protocols Imager still needs to choose many parameters to optimize study. CT DOSE REDUCTION SPECIFIC PARAMETERS kvp (80 to 120 kvp) ma (40 to 180) GANTRY CYCLE TIME (0.3 0.5 secs) PITCH (.5 1.5) Function of table speed and width of xray beam mas = ma x gantry rotation time (Siemens (i scanner incorporates pitch in mas) DETECTOR THICKNESS (.6 &1.2mm) ( Siemens 64 detector) Differences with varying manufacterer, e.g. Siemens has increased beam filtration, 40mAs on Siemens64 equivalent to 23mAs on GE64 CT DOSE REDUCTION SPECIFIC PARAMETERS Kilovoltage ( kvp) SINGLE MOST EFFECTIVE DOSE REDUCTION STRATEGY Typical 80 to 140 kvp for CT Exponential dose relationship ( decrease kvp from 120 to 100 dose decreased 39%) Decreased kvp produces increased contrast but also increased noise Decrease Kvp( 80 to 100kVp) in small children and high contrast studies e.g. CTA, Musculoskeletal 6

LPCH CHEST CT Results 2006 to 2008 major change was 120kVp to 80 or 100kVp 3 years / boy, 14.7 kg, 2006-120kVp <15 kg, CTDI vol, DLP, and ED were reduced by 73%, 75% and 73% respectively 15 60 kg, CTDI vol, DLP, and ED were reduced by 45%, 44% and 48% by using 2008 protocol All of these dose reductions were statistically significant Objective noise measurements and subjective quality assessments were still acceptable 4 years / boy, 14.1 kg, 2008-80kVp CT DOSE REDUCTION SPECIFIC PARAMETERS ma Linear relationship:1/2 ma=1/2 DOSE Decreased ma Increased noise Most pediatric scans should be in the 40 to 180 ma range depending on: weight; ih site (higher for brain and abdomen than chest and extremities); slice collimation ( thinner slice selection often defaults to a higher ma ) detail required (less for larger lesion, f/u scan, planning scan e.g precontrast ) 15 mas GE CT DOSE REDUCTION SPECIFIC PARAMETERS Gantry cycle time (0.3 1.0 sec) x ma = mas Linear relationship also:1/2 time=1/2dose Faster scan useful: less need for sedation decreased motion artefact Increased noise with decreased spatial resolution CT DOSE REDUCTION SPECIFIC PARAMETERS PITCH This is a function of table speed and width of the Xray beam More complex parameter in multidetector scanners Lower pitch produces higher image quality and higher radiation dose In general a higher pitch (around 1 1.5) is fine for most pediatric scans. <1 pitch if high detail is required. Note some scanners automatically increase ma to adjust for higher pitch 7

DETECTOR WIDTH.6mm or 1.2mm Thinner detector increases dose approx. 20%, use for high detail scan e.g. CTA. Conventional CT 60mAs 5mm (1.2 mm det) CTA 190mAs 1.25mm (.6mm det) SLICE GAPS Slice gaps e.g. HRCT 1mm thick slices every 5 10mm can reduce dose by 50% to 80% versus contiguous or volumetric scanning, although there is a tendency to significantly increase ma in HRCT scans to increase resolution and decrease noise. Some scanners increase ma automatically with decreased slice thickness &/or cannot obtain a single slice at each selected level 17yo M trauma- bronchial injury EKG GATED CT Marked increased radiation dose. 4 to 5X nongated CTA Multiple slices at each level throughout the cardiac cycle Requirement for thin collimation, low pitch for highest spatial resolution of small structures ( coronaries) 17yo M with syncopal episode Aberrant Right Coronary artery SPECIFIC DOSE REDUCTION STRATEGIES Protective Shields LOW DOSE HRCT PLUS BREAST SHIELD 14yo F CF Reusable or disposable protective shields of different sizes available for breast, thyroid, eyes Thin 2 ply bismuth strip with underlying foam pad placed anteriorly Attenuates the xray beam, especially the low energy rays. Foam pad absorbs scatter Does not completely block xrays but decreases breast dose by about 20 30% Causes some increased noise but can still be used effectively even in very low dose protocols.6mm thick 100kVp 40mAs INSPIRATORY 1mm thick 8

GENERAL CT DOSE REDUCTION STRATEGIES Tailor the CT to best answer the clinical questions COMMUNICATATION Limit location to area of interest e.g. heart only. Avoid radiosensitive organs where possible e.g. thyroid Avoid routine multiple series e.g. pre and post contrast tscans or both arterial and venous phase imaging Delayed images only when necessary e.g. renal trauma. Limit location Scanning two or more phases is the same as obtaining multiple separate scans 3yo Abdominal pain EARLY DELAY NONACCIDENTAL INJURY There is a tendency to quickly adopt adult practices and protocols in children. Particularly occurs in situations where there is overlap care, such as in many ER s. TRAUMA SERIES PEDIATRIC DISEASE PATTERNS DIFFER FROM ADULTS ORDERING AND PERFORMING IMAGING STUDIES SHOULD LIKEWISE BE SPECIFIC TO THE CLINICAL CONCERN, SIZE OF THE CHILD AND BODY PART SCANNED 14 YO M ATV ACCIDENT NORMAL CT ABDOMEN(OUTSIDE), HEAD, FACIAL, ENTIRE SPINE 40mAs 5mm 90mAs 1.25mm All 120kVp, mean mas 250 EST. ED >20mSV Post dislocation lt clavicle Comp Lt IV 9

Future CT Capability 128/256 detectors Chest CT<1sec, dose much lower kvp As well as mas automodulation, Lower kvp - 70 Organ based dose modulation- Xray turned off anteriorly over breasts Adaptive collimator control- shields area above and below desired scan location ( overranging) Iterative reconstruction with noise reduction Cardiac CT, prospective gating with dose modulation or EKG triggering. Flash dual source scan within 1 heartbeat (.25secs) Much faster, much lower dose Dual source- faster scan, tissue differentiation, virtual noncontrast SUMMARY Many people and technical factors need to work together to improve and optimize CT imaging in children Important not to treat children as little adults Customize protocols that are appropriate for children and follow them ALARA is the guiding principle for all imaging techniques involving ionizing radiation. Always aim for high quality study at lowest dose Dose saving capability only effective if you use them BE AN ADVOCATE FOR THE CHILD Question study requests or protocols that appear unusual Question orders to do multiple sequences or follow adult protocols 10