ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

Similar documents
STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

Straumann Dental System Indication-based prosthetic workflow. Technical Information

Restoring Straumann implants. with Locator abutments.

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

the way to straumann cares abutments

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

Straumann Dental Implant System. Fax Order Form Collection.*

SwissPlant Prosthetic Catalog. SwissPlant

Stock Prosthetic Guide 2014

Product Information. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance. The NEW. Variobase family members

The difference is obvious. Original components by Straumann

SURGICAL PROCEDURES FOR ROXOLID IMPLANTS

CROWN AND BRIDGE RESTORATIONS WITH THE SYNOCTA PROSTHETIC SYSTEM

SS Implant System 2013 PROSTHETIC PROCEDURE

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

Bridging the Gap Between Original and Multi-Platform Systems.

INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Straumann Screw-retained Prosthetics

surgical and prosthetic options & impression technique overview

cement-retained single crowns using cementable abutments

Product Information for Labs. etkon ident Perfectly versatile. Performance you can rely on.

seamless connections

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

PROSTHETIC EFFICIENCY. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance.

Product Information. Straumann CARES Scan & Shape Turn into digital.

CEMENT-RETAINED CROWNS AND BRIDGES WITH THE SOLID ABUTMENT SYSTEM

Quick start Prosthetics

Straight Octagon Abutment for Tissue Level Implant

More than a denture. A new and natural-looking smile.

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

» For multi-unit restorations -

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

Straumann synocta Prosthetic System Basic Information. Technical Information

More than a short implant.

1 mm 2 mm 3 mm 4 mm 5 mm 6 mm

introduction to BioHorizons prosthetics

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

Legacy Prosthetic Catalog

SCREW-RETAINED RESTORATION LINE. THE MULTI UNIT ABUTMENT SYSTEM ON STRAIGHT and tilted IMPLANTS

Guidance for. implant removal. Straumann Dental Implant System

More than a Ti-base. Your trusted link between implant and restoration. Straumann Variobase C. Variobase for CEREC becomes Variobase C

UFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics

SimpleLine II Surgical / Prosthesis Manual

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free

More than pure esthetics. The natural and strong solution.

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

- RESTORATIVE PRODUCT CATALOG

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

Product Catalog 2017/2018. Straumann International Edition

TS Implant System 2013 PROSTHETIC PROCEDURE

TRINON. Index. Index. Overview Page 4. Catalogue

RePlant System Prosthetic Catalog

US Implant System 2013 PROSTHETIC PROCEDURE

HEXAGON Implant System

For the oral rehabilitation

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

BONE LEVEL ABUTMENTS. on4. multi-unit

PROSTHETICS. Fabrication of an overdenture using retentive anchors

NobelParallel Conical Connection Product overview

Transforming the Implant Industry. Broadest Product Line Highest Quality-Best Value

cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves

Product Catalogue. Swedish premium quality Competitive prices Proven performance CE0402

External Hex 4.1 & 5.0 platform

PROSTHETIC PROCEDURE for TS & GS Implant System

CHECK-UP Determination of Impression type & Method after implant placement

» Prosthetic Options by MEDENTiKA «

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

screw-retained crown using a PEEK temporary abutment

Straumann Basic Guided Surgery Cassette. More than a simple cassette. A smart Guided Surgery solution.

THE WORD Smart screw installation Access angle to implant screws

Straumann Guided Adapter. Basic information on. the Straumann Guided Adapter

SuperLine & Implantium Surgical / Prosthesis Manual

NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions.

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

NARROW DIAMETER implant

verification jig fabrication

Straumann Variobase for Bridge/Bar

STRAUMANN CARES DIGITAL SOLUTIONS. CARES Implant Prosthetics Ultimate restorative flexibility.

Smarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants

abutment selection guide

screw-retained crown using the Laser-Lok Easy Ti temp abutment

Osteotome inserts kit, angled. Impression tube (open tray) Selection abutment kit / Selection measurement post. Bar base PMMA & Finisher

Continuing Education. Implant Prosthetics for the General Practice. Samuel M. Strong, DDS

Basic information on the. Straumann Pro Arch TL. Straumann Pro Arch TL

INTRODUCTION. Why Choose Cortex Prosthetics?

Multi-unit abutment open tray technique using the direct pick-up coping

NobelProcera Product Overview

Ø Smaller and Stronger.

SuperLine & Implantium Surgical / Prosthesis Manual

SIC invent. SIC P2F Abutment Dr. Galip Gurel From the gingiva shaper to a provisional crown to the final aesthetic restoration

3. Guarantee conditions

Care for your dental implants. Patient information on dental implant aftercare

Transcription:

Choosing the correct Straumann abutment for crowns, bridges, and bars Straumann abutments are torqued to 35 Ncm by using the ratchet with torque control device and the appropriate abutment driver. Abutments for use with Abutments for use with Indications (Regular Neck) implants (Wide Neck) implants 6 Solid abutments (all solid abutments have a 6 taper) 7.0 mm ß For crowns and bridges 048.540 048.541 048.542 048.545 048.546 yellow grey blue green brown Note: Abutments for use with crowns and bridges should not be used with implants that have been placed more than 2.0 mm below the subgingival margin. Straumann offers different prosthetic options for subgingival cases. The synocta prosthetic system allows the impression to be taken at the implant level before an abutment is placed, allowing abutment selection to be evaluated on the model with plastic planning parts. Straumann s synocta abutments can ONLY be used with Straumann implants that have the internal octagon configuration (identified by the 043. and 033. prefix of the implant article number). 1.5 mm 048.605 048.602 1.5 mm 048.606 048.603 synocta cementable abutments ß For crowns and bridges ß Can be especially helpful with large multi-unit cases Note: synocta cementable abutments can be shortened occlusally by a maximum of 2.0 mm. synocta 1.5 mm abutments ß For crowns and bridges (can also be used with a gold coping to fabricate a custom abutment for a restoration) ß For bar-retained overdentures 6.7 mm, long 6.7 mm, long 5.7 mm, short 5.7 mm, short 048.612-15, short, A 048.613-15, short, B 048.610-15, long, A 048.611-15, long, B 4.25 mm 048.620 8.8 mm 048.617-20, short, A 048.618-20, short, B 048.615-20, long, A 048.616-20, long, B 048.608-15, A 048.609-15, B synocta angled abutments ß For cement or crowns and bridges ( is for ONLY) ß For cases with angulation problems Note: The short synocta angled abutments are 1.0 mm shorter than the long and cannot be modified. synocta transversal abutment ß For lingual crowns and bridges ß Transversal screw retention is used in cases where occlusal screw retention is not feasible due to esthetic requirements and/or axial alignment of the screw. synocta gold abutment ß For cement or crowns ß Ideal for the fabrication of a custom restoration ß Is good for the esthetic region 048.642

Component stack sheet Cement-retained restorations 7.0 mm minimum vertical height required for a porcelain fused to metal restoration 1 minimum vertical height required for a porcelain fused to metal restoration 1 Minimum vertical height of 6.0 mm is required for an all-metal restoration (synocta cementable abutments can be shortened occlusally by a maximum of 2.0 mm, which would allow for a porcelain fused to metal restoration with a minimum vertical height requirement of 5.0 mm.) 2 3 Minimum vertical height of 4.5 mm is required for an all-metal restoration ( solid abutments can be shortened occlusally by a maximum of 1.0 mm, which would allow for a porcelain fused to metal restoration with a minimum vertical height requirement of 4.5 mm.) 2 3 1. synocta plastic coping 2. synocta cementable abutment 3. Straumann implant 1. Plastic coping 2. Solid abutment 3. Straumann implant Custom abutment restoration 4.25 mm 5.75 mm minimum vertical height required for a porcelain fused to metal restoration 1 NOTE: Other types of restorations with the Straumann Dental Implant System may have different height requirements. NN Narrow Neck (Ø 3.5 restorative platform) Regular Neck (Ø 4.8 mm restorative platform) Wide Neck (Ø 6.5 mm restorative platform) Minimum vertical height of 4.75 mm is required for an all-metal restoration 2 3 1. synocta occlusal screw 2. synocta gold abutment 3. Straumann implant International Headquarters Institut Straumann AG Peter Merian-Weg 12 CH-4002 Basel, Switzerland Phone +41 (0)61 965 11 11 Fax +41 (0)61 965 11 01 North American Distributors Straumann USA, LLC 60 Minuteman Road Andover, MA 01810 Phone 800/448 8168 978/747 2500 Fax 978/747 2490 www.straumannusa.com Straumann Canada Limited 4145 North Service Road, Suite 303 Burlington, ON L7L 6A3 Phone 800/363 4024 905/319 2900 Fax 905/319 2911 www.straumann.ca Straumann products are CE marked 8/07 USLIT 097

PROSTHETIC OPTIONS

NN (Narrow Neck) Straumann Dental Implant System Ø 3.5 mm System Overview P ROSTHETICS Narrow Neck Transfer parts Solid 048.017V4 048.016 048.122V4 048.130 048.060/061/062V4 048.160/161/162 or Prosthetic restoration 048.017V4 048.117V4 Plastic planning parts 048.935V4 048.936V4 048.937V4 048.926/927/928V4 Abutments 048.540 048.541 048.542 Temporary restoration/ protective caps/healing caps 048.374 048.043 048.050 048.505 048.550 048.551 048.654 /655 048.047/048/049V4 Titanium copings/ matrices 048.214 Gold copings/ matrices 048.635 048.500 048.204 Plastic copings 048.246 048.245 / Auxiliary parts/screws 049.177 048.350V4 Transfer aids crown bridge bar not for hollow cylinder implants, 15

(Regular Neck) Ø 4.8 mm synocta 048.090 O 048.010 048.017V4 048.070V4 048.124 or 048.929V4 048.642 048.602 048.921V4 / 048.916/917/918/919V4 048.620 / 048.612/613/617/618 048.651 4 /241 048.10 048.650 u 048.922/923/924/925V4 048.930V4 048.610/611/615/616 048.605 u 048.560 retentive a 048.43 048.668 /240 048.45 048.632 048.633 048.634 048.227 048.229 048.665 048.360V4 048.361V4 048.356 048.676V4 049.154 048.672 048.003V4 V2 = 2 components per pack 048.45 048.670 048.662 048.663 048.350V4 048.000V4 V4 = 4 components per pack 048.002V4 V20 = 20 components per pack 048.059V4

(Wide Neck) Ø 6.5 mm Overdenture 09 anchor 39 50 Solid 048.013 048.197V4 synocta 048.013 048.065/066 048.013 048.091 048.198V4 LOCATOR 048.175 048.180 048.165/166 048.140 048.545 048.546 048.656 /657 048.051/052 048.095 048.171 048.931V4 048.933V4 048.934V4 048.932V4 048.603 048.608 048.609 048.606 048.233 048.234 048.189V2 56 048.248 048.196V20 048.247 048.638 048.639 048.666 048.667 048.350V4 048.678 048.244 048.243 048.032 048.054V4 048.361V4 048.561