Coronary angiography is the standard way of visualizing

Similar documents
Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Contrast enhanced electron beam computed tomography to analyse the coronary arteries in patients after acute myocardial infarction

X-ray coronary angiography is considered the diagnostic

Adapted Transfer Function Design for Coronary Artery Evaluation

Cardiac Imaging Tests

Correlation of Cardiac CTA to Conventional Cardiac Angiography in Diagnosing Coronary Artery Stenosis in a Community Based Center

Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography

Improved Noninvasive Assessment of Coronary Artery Bypass Grafts With 64-Slice Computed Tomographic Angiography in an Unselected Patient Population

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

2004;77:800 4 MSCT OF CORONARY ARTERY BYPASS GRAFTS. Results. CABG With Adequate Diagnostic Quality

SYMPOSIA. Coronary CTA. Indications, Patient Selection, and Clinical Implications

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

MR Advance Techniques. Vascular Imaging. Class II

General Cardiovascular Magnetic Resonance Imaging

Multidetector CT Angiography for the Detection of Left Main Coronary Artery Disease. Rani K. Hasan, M.D. Intro to Clinical Research July 22 nd, 2011

Chapter 4. Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands. Department of Radiology,

Multidetector Computed Tomography (MDCT) in Coronary Surgery: First Experiences With a New Tool for Diagnosis of Coronary Artery Disease

Dr Felix Keng. Imaging of the heart is technically difficult because: Role of Cardiac MSCT. Current: Cardiac Motion Respiratory Motion

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Cardiac Computed Tomography

High-Resolution MR Angiography: Results in Diseased Arteries

MR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique

Interpreting CT Angiography: Three-Dimensional Reconstruction Techniques

Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing

Studies with electron beam computed tomography (EBCT) Imaging

Raja Muthupillai, PhD. Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital. Research Support: Philips Healthcare

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006

Banding and Step-Stair Artifacts on the Cardiac-CT Caused By Pseudo-Ectopic Beats

TITLE: Multi-Slice Computed Tomography Coronary Angiography for Coronary Artery Disease: A Review of the Clinical Effectiveness and Guidelines

Magnetic Resonance Angiography

Chapter. Non-Invasive Coronary Imaging and Assessment of Left Ventricular Function using 16-slice Computed Tomography

Purpose. Methods and Materials

Integrating CT in minimally invasive treatment of the coronary arteries

Coronary CT Angiography

Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography

Coronary artery bypass grafting has been a historically. Multislice CT Evaluation of Coronary Artery Bypass Graft Patients SYMPOSIA

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 1, FEBRUARY

What every radiologist should know about cardiac CT: A case-based pictorial review

b. To facilitate the management decision of a patient with an equivocal stress test.

Recent developments in cardiac CT

General Imaging. Imaging modalities. Incremental CT. Multislice CT Multislice CT [ MDCT ]

Fulfilling the Promise

The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6

Methods. Circ J 2004; 68:

The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses

Sang Ho Lee, Byoung Wook Choi, Hee-Joung Kim*, Member, IEEE, Haijo Jung, Hye-Kyung Son, Won-Suk Kang, Sun Kook Yoo, Kyu Ok Choe, Hyung Sik Yoo

Threshold Selection for CT Angiography Shaded Surface Display of the Renal Arteries

ROLE OF MULTISLICE COMPUTED TOMOGRAPHY IN CARDIAC IMAGING

Updates on Coronary Angiography Rotational Angiography, 3-D Modeling, and

Length Measurements of the Aorta After Endovascular Abdominal Aortic Aneurysm Repair

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Detection of Coronary Artery Stenoses with Thin Slice Multi Detector Row Spiral Computed Tomography Angiography

Index. average stress 146. see ACIS

Multislice CT angiography in abdominal aortic aneurysm treated with endovascular stent grafts: evaluation of 2D and 3D visualisations

A new method for radiation dose reduction at cardiac CT with multi-phase data-averaging and non-rigid image registration: preliminary clinical trial

M Marwan, D Ropers, T Pflederer, W G Daniel, S Achenbach

MR Advance Techniques. Cardiac Imaging. Class IV

Simon Nepveu 1, Irina Boldeanu 1, Yves Provost 1, Jean Chalaoui 1, Louis-Mathieu Stevens 2,3, Nicolas Noiseux 2,3, Carl Chartrand-Lefebvre 1,3

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre

Impact of SSF on diagnostic performance of coronary CT angiography within one heart beat in patients with high heart rate using a 256-row detector CT

Noninvasive Coronary Angiography with 16 Detector Row CT: Effect of Heart Rate 1

Cardiac CT: Your chest pain patient CAN be discharged from the Emergency Department

Utility of CT angiography for pre-operative evaluation of robotic-assisted minimally invasive mitral valve surgery.

Saphenous Vein Autograft Replacement

The New England Journal of Medicine

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

Bottom up cardiac CT for CABG assessment to resolve breathing artefact

Electron Beam CT of the Heart

9/8/2009 < 1 1,2 3,4 5,6 7,8 9,10 11,12 13,14 15,16 17,18 > 18. Tetralogy of Fallot. Complex Congenital Heart Disease.

Cardiac computed tomography: indications, applications, limitations, and training requirements

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

I have no financial disclosures

Imaging Strategies for Endovascular Cardiovascular Procedures and Percutaneous Aortic Valves. Roy K Greenberg, MD

New Horizons in the Imaging of the Lung

Anatomical and Functional MRI of the Pancreas

Index. radiologic.theclinics.com. Note: Page numbers of article titles are in boldface type.

Chapter 43 Noninvasive Coronary Plaque Imaging

Coronary Artery Disease - Reporting and Data System (CAD-RADS)

Computer-Assisted Navigation on the Arrested Heart during CABG Surgery

Computer Assisted Coronary CT Angiography Analysis

Chest X-ray Interpretation

Coronary Artery Anomalies from Birth to Adulthood; the Role of CT Coronary Angiography in Sudden Cardiac Death Screening

Computed tomography. Department of Radiology, University Medical School, Szeged

Cardiac CTA Prospective Gating Broad Beam

Tc-99m Sestamibi/Tetrofosmin Stress-Rest Myocardial Perfusion Scintigraphy

Anatomic Evaluation of the Circle of Willis: MR Angiography versus Intraarterial Digital Subtraction Angiography

Case 47 Clinical Presentation

Evaluation of Intermediate Coronary lesions: Can You Handle the Pressure? Jeffrey A Southard, MD May 4, 2013

Diagnostic accuracy of dual-source computed tomography in the detection of coronary chronic total occlusion: Comparison with invasive angiography

Progress in CT. Jim Green Senior Vice President & General Manager Philips CT

Intravascular Ultrasound for Complex Cases

PULMONARY EMBOLISM ANGIOCT (CTA) ASSESSMENT OF VASCULAR OCCLUSION EXTENT AND LOCALIZATION OF EMBOLI 1. BACKGROUND

Expert Consensus Document

Transcription:

Clinical Investigation and Reports Coronary Artery Fly-Through Using Electron Beam Computed Tomography Peter M.A. van Ooijen, MSc; Matthijs Oudkerk, MD, PhD; Robert J.M. van Geuns, MD; Benno J. Rensing, MD, PhD; Pim J. de Feyter, MD, PhD Background Virtual reality techniques have recently been introduced into clinical medicine. This study examines the possibility of coronary artery fly-through using a dataset obtained by noninvasive coronary angiography with contrast-enhanced electron-beam computed tomography. Methods and Results Ten patients were examined, and 40 to 60 transaxial tomograms (thickness, 1.5 mm; in-plane pixel dimensions, 0.5 0.5 mm) were obtained after intravenous contrast injection. The datasets were processed on a graphics workstation using volume-rendering software. For fly-throughs, the contrast-enhanced lumen was made transparent and other tissue was made opaque. Then, key frames were selected in a path through the vessel, with software interpolation of frames between key frames. A typical movie contained 150 to 300 frames (10 to 15 key frames). Fly-throughs of coronary bypass grafts (n 3), left anterior descending arteries (LAD; n 6), and the intermediate branch (n 1) were reconstructed. Coronary calcifications were seen in 3 patients. The fly-through of the intermediate branch, the bypass grafts, and one of the LADs did not show any irregularities. In 2 cases, a stenosis was visible in the LAD; its presence was confirmed by conventional coronary angiography. Conclusions Recent developments in fast-volume rendering using special-purpose hardware in combination with noninvasive coronary angiography with electron beam computed tomography have provided the possibility of performing coronary artery fly-throughs. (Circulation. 2000;102:e6-e10.) Key Words: angiography tomography, x-ray computed computers imaging Coronary angiography is the standard way of visualizing the coronary arteries. However, this method is invasive and, in a few cases, the procedure is associated with complications and has a small risk of mortality. Therefore, noninvasive methods to visualize the coronary arteries are currently under investigation; these include MRI 1,2 and electron-beam computed tomography (EBT). 3,4 Coronary angiography depicts the coronary artery as a planar silhouette (lumenogram) and, therefore, only detects a stenosis if the plaque obstructs the lumen; it also provides no information on the vessel wall. Coronary artery fly-through is another way to provide a comprehensive delineation of the lumen and the impact of vessel wall disease on the lumen. Some examples of fly-throughs of the coronary arteries with calcifications and stenoses are shown in this article. Methods For this study, 10 patients were selected who had a noninvasive, contrast-enhanced EBT angiogram of adequate quality. The data acquisition was performed on an Evolution XP (Imatron) EBT scanner. The acquisition of the 3D dataset began with the injection of 120 to 180 ml of contrast medium at 3 to 4 ml/s through an antecubital vein. Scanning commenced just proximal to the left main coronary artery after an ECG trigger at 80% of the RR interval (diastasis). The tomogram (slice) thickness was set at 1.5 mm, and the table increment after each tomogram was set at 1.5 mm, which resulted in contiguous, nonoverlapping slices. A total of 40 to 60 transaxial tomograms were made during a single breath-hold. Breath-holding is necessary during data acquisition to avoid respiratory motion artifacts. Field-of-view size was generally set at 18 cm, with a matrix size of 512 512 pixels; this yielded a pixel size of 0.35 0.35 mm. The acquired data were then transferred to a special-purpose graphic workstation (Indigo2, Silicon Graphics, Inc) running VoxelView software (Vital Images) for volume rendering and processing. 5 8 The volume dataset consisted of voxels (3D pixels), each of which had a certain value that was based on the tissue density value measured by the EBT scanner. Using these voxel values, several types of renderings can be performed. One of the possibilities is to construct a fly-through movie. A fly-through is similar in some ways to a flight-simulator. The surroundings in a flight-simulator are all virtually stored in a large computer database, and the image shown to the pilot is based on the position and direction of the virtual airplane in the virtual surroundings. By a fast and smooth replacement of the image of the virtual surroundings, the illusion of flying is created. In the case of a coronary artery fly-through, the surroundings are the scanned Received December 1, 1999; revision received January 25, 2000; accepted February 7, 2000. From the Department of Radiology (P.M.A.v.O., M.O.) and Thoraxcentre (R.J.M.v.g., B.J.R., P.J.d.F.), University Hospital Rotterdam/Daniel, Rotterdam, The Netherlands. Figures I through III can be found at http://circ.ahajournals.org/cgi/content/full/102/1/dc1 Correspondence to Peter M.A. van Ooijen, MSc, Dept of Radiology, University Hospital Rotterdam/Daniel, Groene Hilledijk 301, 3075 EA Rotterdam, The Netherlands. E-mail ooijen@radh.azr.nl 2000 American Heart Association, Inc. Circulation is available at http://www.circulationaha.org 1

2 Circulation July 4, 2000 Figure 1. Top, these graphs contain 2 types of information. The histogram shows the distribution of the voxel values. The x axis represents the voxel value, and the y axis, the number of voxels with this value. The line graph shows the opacity value assigned to a certain voxel value. The x axis again represents the voxel value, and now the y axis shows the opacity percentage (low value is transparent; high value is opaque). The images on the bottom demonstrate the effect of a change in opacity setting. The bottom left image shows the typical opacity setting used to depict the contrast-rich blood in the lumen of the vessel (maximum opacification), which is not necessarily an optimal setting for the depiction of the coronary arteries. In this case, the soft tissue and fat (with a lower voxel value) are transparent, and the contrast-enhanced blood (with a higher voxel value) is fully opaque. On the bottom right, the opacity for the soft tissue and fat is high (small peak in the yellow curve), and the voxel values corresponding to contrast-enhanced blood are fully transparent. As can be appreciated from the image shown, this type of setting hollows out the vessels, which enables flying through. data, and the airplane can be thought of as a camera mounted on the tip of a catheter. The images shown are based on the position and direction of this catheter in the coronary artery. By displaying images at consecutive positions along a certain path through the coronary (the flight path), the illusion of moving through this artery is created. To make a fly-through movie like this, the vessels must be hollowed out by assigning voxels representing contrast-media rich blood an opacity of zero (full transparency) (Figure 1). Next, the viewpoint is moved inside the aorta or coronary artery; this will be the first key frame. After this, a number of viewpoints can be selected, which are positioned along the flight path as key frames for the movie (typically 10 to 15 key frames are selected). These key frames and the desired number of frames to be interpolated between the key frames are fed into the VoxelAnimator software, which is used to render the movie. From this information, the software interpolates a curve through the defined key frames and renders the requested number of new frames between the key frames along this curve, which results in a 150- to 300-frame movie. Results The 3D EBT datasets of 39 patients were evaluated, with special attention paid to interslice correlation quality, lack of artifacts, and slice image quality. The best 10 datasets were selected for coronary artery fly-throughs. From these 10 patients, fly-through movies of coronary artery bypass grafts (n 3), the left anterior descending artery (LAD; n 6), and the intermediate branch (n 1) were constructed. Typical examples from a bypass (Figure 2 and Figure I [Figures I to III can be found online at http:// circ.ahajournals.org/cgi/content/full/102/1/dc1]) and from the LAD (Figures 3 and 4 and Figures II and III) are shown. Coronary calcifications were visible in 3 patients (eg, Figure 4 and Figure III), and a significant stenosis, which was confirmed by conventional diagnostic coronary angiography, was depicted in 2 patients (eg, Figure 3 and Figure II). Discussion EBT coronary angiography has emerged as a potentially viable technique for noninvasive visualization of coronary arteries and coronary bypass grafts. 3,4 However, although the technique is reasonably robust, only 81% of the major coronary artery branches could be visualized with sufficient quality to assess patency, the presence of a severe stenosis, or total occlusion. 4 For the reconstruction of fly-through movies, the image quality of the 3D datasets must be perfect. Even small irregularities may hamper the successful construction of a coronary artery fly-through. Aquisition problems include the following. (1) Problems with breath-holding may reduce the continuation of a coronary artery from one slice to another. (2) Arrhythmia, or even a single premature complex, may lead to images that are triggered at a slightly different time in the heart cycle, resulting in a displacement of 1 to 2 mm of a single slice with respect to the other slices. This creates a discontinuation of the coronary arteries in 3D reconstructions. (3) Vessels with a diameter 1.75 mm (area, 5 5 pixels) will not provide a smooth coronary fly-through. (4) Movement artifacts of the right coronary artery during the 100-ms image acquisition time hamper the construction of a fly-through movie of this artery. In addition to these acquisition problems, the reconstruction of a coronary artery fly-through is very timeconsuming; therefore, only the best quality datasets with a large vessel diameter were selected to undergo this proce-

van Ooijen et al Coronary Artery Fly-Through 3 Figure 2. A, Volume renderings of a patient with a coronary artery bypass graft. The left image shows the artifact introduced by the segmentation of the sternum and sternal wires as a bright white portion of the bypass graft. Evaluating the patency of the graft at this particular point is difficult. B, When flying through the vessel, it is clear from the first 2 images that the graft is patent. However, a possible calcified region shows up in the second image. By setting the opacity curves slightly differently (third and fourth images), the walls disappear and it becomes clear that this is not a calcified plaque, but an artifact from the sternum and the sternal wires. The actual fly-through is shown in Figure I. dure. For these reasons, a high-quality coronary artery fly-through was reconstructed in only 25% of the eligible patients. Much of the difficulties stated here can be overcome in the future by improvements in the spatial and temporal resolution of the EBT scanner. An update of the scanner is already available with a higher spatial resolution; this will increase the image quality and provide the possibility to display and fly-through smaller vessels. A reduction of slice acquisition time to below 100 ms will decrease the artifacts introduced by the movement of the right coronary artery. New scanning techniques that allow the acquisition of 1 slice during each heartbeat will shorten total scanning time and, thus, reduce the artifacts introduced by arrhythmias and breath-holding problems. Furthermore, the rapid development of both specialpurpose rendering hardware and software will provide faster and more interactive ways to reconstruct fly-through movies. Fly-through movies of venous bypass grafts are relatively easy to make because the vessel diameter is relatively large, and the cardiac motion of these vessels is limited. However, surgical clips or sternal wires may sometimes degrade the images because of the bright artifacts they cause (Figure 2 and Figure I). Calcifications of the vessel wall, which have a very high voxel value, are retained in the fly-throughs and are visible as white blobs floating in the artery (Figure 4 and Figure III). These preliminary findings demonstrate the feasibility and potential of this method in coronary artery or bypass graft fly-through movies. The technique of coronary artery fly-through cannot be considered an alternative to traditional coronary angioscopy because it does not provide any information about the color of the lumen or its contents, such as plaque and thrombus. Coronary artery fly-through is an alternative way to evaluate noninvasive coronary angiography, and it has several advantages. (1) It provides a delineation of the true 3 dimensions of the vessel lumen, unlike diagnostic angiography (lumenography), which is limited by foreshortening and overlapping structures. (2) Fly-throughs may eliminate the time-consuming segmentation of overlapping, obscuring anatomical structures (left atrium, coronary sinus) that is needed to visualize the coronary arteries from the outside. (3) Flythroughs may provide a more comprehensive delineation of bifurcation lesions or anastomoses of grafts on native vessels, which are sometimes difficult to asses, even with routine diagnostic angiography. Finally, fly-throughs may be helpful in assessing the remaining coronary lumen of a

4 Circulation July 4, 2000 Figure 3. A, The left image shows a 3D volume rendering of the coronary arteries. The stenosis can be seen in the proximal part of the LAD right after the left main. This stenosis was confirmed using conventional coronary angiography shown on the right. B, Some interesting frames from the fly-through. The trifurcation through the lumen is approached in frames 1 through 6, and movement is toward the stenosed origin of the LAD. Frame 7 shows the stenosis in close-up and, in frame 8, the stenosis has been crossed and the remaining part of the LAD is seen. The actual fly-through is shown in Figure II. Figure 4. When flying through a calcified LAD, the calcifications show up as white blobs floating inside the vessel. In this case, 3 big calcifications were passed on the fly-through of the LAD. The actual fly-through is shown in Figure III.

van Ooijen et al Coronary Artery Fly-Through 5 heavily calcified coronary plaque or stented segment, which may be invisible with traditional EBT-derived 3D rendering techniques. Conclusions A fly-through of coronary arteries and venous bypass grafts is feasible in clinical practice and may represent a future diagnostic technique that will allow comprehensive 3D delineation of the vessel lumen. References 1. Manning WJ, Li W, Edelman RR. A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med. 1993;328:828 832. 2. Van Geuns RJM, de Bruin HG, Rensing BJWM, et al. MRI of the coronary arteries: clinical results from three-dimensional evaluation of a respiratory gated technique. Heart. 1999;82:515 519. 3. Moshage W, Achenbach S, Seese B, et al. Coronary artery stenoses: three-dimensional imaging with electrocardiographically triggered, contrast agent-enhanced, electron-beam CT. Radiology. 1995;196: 707 714. 4. Rensing BJ, van Geuns RJM, Bongaerts AHH, et al. Intravenous coronary angiography using electron beam computed tomography, a viable alternative to conventional coronary angiography. Circulation. 1998;98: 2509 2512. 5. Ney DR, Fishman EK, Magid D, et al. Volumetric rendering of computed tomography data: principles and techniques. IEEE Computer Graphics Appl. 1990;10:24 32. 6. Fishman EK, Magid D, Ney DR, et al. Three-dimensional imaging: state of the art. Radiology. 1991;181:321 337. 7. Heath DG, Soyer PA, Kuszyk BS, et al. Three dimensional spiral CT during arterial portography: comparison of three rendering techniques. Radiographics. 1995;15:1001 1011. 8. Kuszyk BS, Heath DG, Ney DR, et al. CT angiography with volume rendering: imaging findings. AJR Am J Roentgenol. 1995;165: 445 448.