Amino Acid Methods: Present and Future. Claire Hart Sheffield Children s Hospital

Similar documents
Report from the Amino Acids Working Group. Ann Bowron Anny Brown Helena Kemp

MS/MS APPROACHES TO CLINICAL TESTING FOR INBORN ERRORS OF METABOLISM

Comparison of a UPLC Method across Multiple UHPLC Systems

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

[ APPLICATION NOTE ] UPLC-MS/MS Analysis of 45 Amino Acids Using the Kairos Amino Acid Kit for Biomedical Research INTRODUCTION APPLICATION BENEFITS

Level and activity of D-amino acids in mouse brain tissue and blood

Lab Guide 2019 Metabolic Section Lab Guide

[Application Note] TOXICOLOGY SCREENING BY UPLC/PDA IN COMBINATION WITH AN EXTENSIVE COMPOUND LIBRARY

LC-MS Analysis of Amino Acids on a Novel Mixed-Mode HPLC Column

Am I getting the very best value from my UHPLC analyses?

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

An Introduction to the Use of itraq Reagents for Amino Acid Analysis

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

PRA International Early Development Services Bioanalytical Laboratory

Analysis of L- and D-Amino Acids Using UPLC Yuta Mutaguchi 1 and Toshihisa Ohshima 2*

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Facile t-boc and FMOC Amino Acid Chiral Separations by HPLC

SERVICE SCHEDULE, FEES & GUIDELINES FOR SAMPLE SHIPMENT

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

USP Dietary Supplements Standards Up-to-Date Roundtable Meeting Report. Huy Dinh, MS. Senior Scientific Liaison Dietary Supplements

Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots

Newborn Screening by Tandem

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Practical relevance of measurement uncertainty in inborn errors of metabolism. Prof Jim Bonham Clinical Director Sheffield Children s NHS FT

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

AbsoluteIDQ p180 Kit. Targeted Metabolite Identifi cation and Quantifi cation

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

Proteomics of body liquids as a source for potential methods for medical diagnostics Prof. Dr. Evgeny Nikolaev

4th Multidimensional Chromatography Workshop Toronto (January, 2013) Herman C. Lam, Ph.D. Calibration & Validation Group

Xiaolei Xie, Marta Kozak. Thermo Fisher Scientific, 355 River Oaks Parkway, San Jose, CA Introduction

[APPLICATION NOTE] DETERMINATION OF AMINO ACIDS IN BEERS USING THE UPLC AMINO ACID ANALYSIS SOLUTION

A Novel HILIC Column for High Speed N-linked Glycan Analysis

Comparison of Relative Quantification of Monoclonal Antibody N-glycans Using Fluorescence and MS Detection

Auto HbA1C ANALYZER HbA1LC HPLC 3660

Annual Report ERNDIM-EQAS Quantitative Amino Acids 2002

PerkinElmer talks at spring TCJJP Meeting Wednesday, Mar. 14, 2012

High Performance Liquid Chromatography

GlycanPac AXR-1 Columns

Low-Pressure Chromium Speciation in P2O5 using the Spectro ARCOS MV ICP and the ESI SC-DX chromfast System

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Annual Report ERNDIM-EQAS Quantitative Amino Acids 2004

Analysis of N-Linked Glycans from Coagulation Factor IX, Recombinant and Plasma Derived, Using HILIC UPLC/FLR/QTof MS

SimGlycan. A high-throughput glycan and glycopeptide data analysis tool for LC-, MALDI-, ESI- Mass Spectrometry workflows.

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Newborn Screening & Methods for Diagnosing Inborn Errors of Metabolism

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids

HPLC Analysis of Sugars

Introduction. Goals. Peter Stout

Small Molecule Science: Experimental designs for achieving ultra trace analysis

Pantothenic Acid. Shang-Jing Pan, Ph.D. Abbott Nutrition Columbus, Ohio, USA

Title Revision n date

AbsoluteIDQ p150 Kit. Targeted Metabolite Identifi cation and Quantifi cation. Bringing our targeted metabolomics expertise to your lab.

ANALYSIS OF -HYDROXYBUTYRATE (GHB) AND -BUTYROLACTONE (GBL) IN LIQUIDS PERFORMED AT NATIONAL LABORATORY OF FORENSIC SCIENCE (SKL), SWEDEN

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

The Raptor HILIC-Si Column

Acylcarnitine measurement in blood spots: methodological aspects, problems and pitfalls with reference to the ERNDIM QA scheme

BODY CHEMISTRY TEST. Sample Report

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Challenges in Artemisinin

Diagnostic Proficiency Testing Survey Annual Report

Performance Characteristics of the Agilent 1290 Infinity II Multicolumn Thermostat

Amino acids. Ing. Petrová Jaroslava. Workshop on Official Controls of Feed AGR 46230, , Ankara. Turkey ÚKZÚZ - NRL RO Praha 1

The Impact of Column Peak Capacity on the Multi- dimensional Chromatography of Complex Peptide Mixtures

USER GUIDE. Can You Complete An Amino Acid Analysis In 15:00 Minutes?...now you can! USERGUIDE

High Throughput simultaneous analysis of 39 amino acids in various foods without derivatization using LC-MS/MS

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

1. Sample Introduction to MS Systems:

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

Fig.1. Denatonium benzoate (DB) chemical structure

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Savesta Herbals is engaged in manufacturing

An Introduction and Overview on Comprehensive Two-Dimensional Gas Chromatography (GCxGC): New Opportunities for Unresolved Complex Mixtures

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Use of Derivatization for LC- MS/MS Analysis in the Clinical Lab

Key Advantages of Comprehensive Cannabis Analysis

Proficiency Testing Centre Basel Annual Report 2007

Hemoglobinopathy and thalassemia detection

Choosing the metabolomics platform

Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID

John P. McCauley and Rui Chen Waters Corporation, Milford, MA, USA INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEY WORDS

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

SUPPLEMENTARY DATA. Materials and Methods

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Thin-Layer Chromatography of Amino Acids HASPI Medical Biology Lab 15b Background Macromolecules

Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V.

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Transcription:

Amino Acid Methods: Present and Future Claire Hart Sheffield Children s Hospital

The Status Quo Questionnaire shows everybody using HPLC or ion-exchange amino acid analysers for routine quantitative services Some use tlc /HVE to pre-screen urine and /or plasma samples

Why would we want to change? Long run times for AA analyser, significant maintenance to keep running, temperamental Significant sample preparation times for HPLC, co-eluting peaks Analysers /staff running at capacity (or beyond) Need for rapid results in urgent cases

Some current solutions to the capacity problem Pre-screening samples using tlc and HVE to reduce number of samples that need to be quantitated Using HPLC as a semi-quantitative screen (report as NSA or proceed to quant) Run two amino acid analysers Use tandem or underivatised HPLC method for PKU monitoring Use of short programs to reduce analyser time when only certain amino acids are required e.g. MSUD monitoring

Why look for other alternatives? Screening by tlc has its own problems. significant staff time technically demanding Interpretation and identification of amino acids requires significant experience Have to have low threshold for quantitating samples to be confident of not missing something significant and even then.

Would you have spotted this? Glycine = 110 µmol/l (200-600) Serine = 30 µmol/l (50-350) CSF glycine = <1 µmol/l (0-10) CSF serine = 5 µmol/l (35-80)

Why look for other alternatives? Cost of two instruments Run time is not just a capacity issue, also a need for quick turnaround times in certain circumstances

The ideal analyser would be Fast (run time <30 mins) Little or no sample preparation Separation and positive identification of all diagnostically relevant amino acids Robust equipment, easy to maintain Cheap

What are the possible alternatives? GC-MS Tandem MS UPLC

GC-MS ERNDIM returns indicate a small number of labs using GC-MS for amino acids, (? In house methods or commercial kits) Commercially available EZ:faast amino acid analysis kits for GC-MS -Sample derivatisation with propriety reagent and analysis within 15 mins

Pros Fast Quick derivatisation Analyse 50 amino acids /dipeptides in an 8 min run time

Cons Would need a dedicated GC-MS (can t use same column as organic acids) Citrulline and Arginine are NOT two of the 50

Tandem-MS Use well established in Neonatal Screening Increasingly being used as a solution to amino acid analysis in specific circumstances or specific problem analytes -e.g. Rapid screen in acutely ill child, monitoring of treatment in decompensated MSUD, sulphocysteine Small number of labs are using it for routine analysis

Rapid Screen of the acutely ill child A number of diagnostically useful amino acids can be easily measured by underivatised MS/MS method Can be measured on the same injection as acylcarnitines 10 minutes sample preparation and 3 minute run can give a host of information and either provide a diagnosis or narrow it down considerably What can be measured is limited by the problem of isobaric / isomeric compounds

Monitoring in Decompensated MSUD A probable diagnosis can be made from the simple MS/MS method Need a different method to measure leucine, isoleucine and allo-isoleucine separately to allow planning and monitoring of treatment A chromatographic step is required for separation of the isomers

Possible chromatographic options Macrocyclic glycopeptides eg Chirobiotic TAG (teicoplanin aglycone) Porous graphite column (Hypercarb) -columns easily attached between sample manager and tandem with an extra piece of tubing -adds a few minutes to the run time -allows rapid measurement of leucine and its isomers, ideal for monitoring treatment during crisis when frequent sampling is required

Routine Amino Acid Analysis Small number of labs are using tandem methods for routine amino acid analysis e.g. Piraud et al, Lyon (SSIEM abstract 140-P 2005) -using ion-pairing reverse phase liquid chromatographic method with MS/MS as the detector -run time is ~25mins -in routine use for 18 months, several thousand samples -have diagnosed and monitored wide range of disorders without problems

UPLC (ultra performance liquid chromatography) Souped up version of HPLC Relies on even smaller particle size (made possible by new material) and a system designed to tolerate very high pressures to provide better resolution and increased speed

The promise of the van Deemter plot Smaller Particles The enabler of productivity 2004 Waters Corporation

UPLC cont Run time <20 mins Better resolution than HPLC Requires derivatisation step but this is much shorter than the PITC method (<30 mins) Cost of equipment similar to current amino acid analysers Appears to be capable of analysing all necessary amino acids Unfortunately amino acid analysis by UPLC is still very much in development

UPLC Physiological Amino Acids UV Detection @ 250 nm

One stage further: UPLC- MS/MS Using MS/MS as the detector would allow positive identification of peaks -Best of both worlds, UPLC separates isobaric compounds, MSMS separates coeluting peaks No derivatisation of samples required Rapid, high through-put system suitable for diagnosis, monitoring and urgent analysis with minimal sample preparation Same system could be used for other assays would open up possibilities for the larger, specialist labs

The Future. New technologies could alter the way we operate allowing more flexibility Higher through-put systems could put an end to pre-screening samples by tlc etc In the next few years newer technologies will become more and more of a realistic alternative which way labs decide to go will ultimately depend on staff expertise, costs, existing facilities and equipment, workloads and clinical needs