HemoCue Hb METHOD AND SAMPLE COLLECTION

Similar documents
Alere INRatio 2 METHOD AND SAMPLE COLLECTION

Blood Glucose Monitoring System. User Guide

Items in the package:

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

Dear HighQ Check System Owner :

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

Summary of Significant Changes at this Revision. Items Required

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

The performance of Microdot Test Strips has been evaluated both in laboratory and in clinical tests.

Fraser Health Authority Accu-chek Inform II: Training Script

Determination of hemoglobin is one of the most commonly

PROCEDURE. TITLE: Bedside Glucose Monitoring PC Laboratory. Issuing Department: Clinical Director Signature: Departments Involved:

Accu-Chek Inform II: Point of Care Glucose Testing. Sharp Healthcare 2014

Title: Abbott Optium Xceed Glucose Meter Effective date: 16/05/2011. Summary of Significant Changes at this Revision. SOP updated.

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

Dear Prodigy System Owner:

Blood Glucose Monitoring System

Roche CoaguChek XS Plus INR

User Guide For in vitro Diagnostic Use in Animals Featuring the AlphaTRAK 2 Meter

Summary of Significant Changes at this Revision

Worksheet. Worksheet. Worksheet. Worksheet. Student Performance Guide. Student Performance Guide

User s Manual Blood Glucose Meter

Current Status: Active PolicyStat ID: Accu-Chek Whole Blood Glucose Testing Policy PURPOSE

Lilly. Disposable Insulin Delivery Device User Manual

GlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Table of Contents Information Preparation Testing Additional Functions Maintenance

User Manual. For single user / home use only

User Manual. For single user / home use only

User s Manual. Blood Glucose Meter

Precision Xtra Training

Management of Central Venous Access Devices. Blood Glucose Monitoring

Mission Hb accurately detects both

PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

Blood Glucose & Ketone Monitoring System

User manual for healthcare professionals

User s Manual Blood Glucose Meter

i-stat CHEM8 + Cartridge Quick Reference Guide

Abbott PXP Glucose Meters Resource: Lin Gustafson, MT(ASCP) Point of Care Coordinator, Laboratory

User Manual second language

Blood Glucose Measurement. Omnitest 5 & Omnican Lance FAQ Frequently Asked Questions

System. User Manual for Self-Testing

CentriVet GK Blood Glucose & Ketone Monitoring System

PLUS One. Blood Glucose Monitoring System. Owner s Manual

PRIMA. Blood Glucose Monitoring System. Owner s Manual

BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL

Blood Glucose Meter Owner s Manual

Blood Glucose Monitoring System. Owner s Booklet

Integrated Multiparameter Monitoring System. Owner s Manual

To provide you with necessary knowledge and skills to accurately perform 3 HIV rapid tests and to determine HIV status.

TRUEHb HEMOMETER. Instructions for Use. Wrig Nanosystems Pvt. Ltd.

Blood Glucose & Ketone Monitoring System. User s Manual

Blood Ketone and Glucose Monitoring System Owner s Guide For Veterinary Animal Use Only Not For Human Use

Dear HemoSmart GOLD Owner

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

GM700S USER S MANUAL. Blood Glucose Monitoring System

Owner's Booklet. Blood Glucose Monitoring System. Accurate, complete blood glucose monitoring through advanced biosensor technology

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

Tips for Training New Customers

INTRODUCTION: TRUE METRIX

Blood Glucose Monitoring System

Table of Contents. Section 1 Introduction... 1 Section 2 Getting Started... 2 Section 3 Components... 5

I. Subject: Ionized Calcium (Ca++) Analysis Whole Blood

EasyPlus mini 2IN1. Self-Monitoring Blood Glucose System. User s Manual

EasyMax Voice III. User s Manual

Summary of Significant Changes at this Revision. Items Required. Printed copies are uncontrolled unless there is an allocated Copy Number on page 1

User Manual. This is a CLIA waived system.

2. Before Testing Monitor Checker Test...10 Inserting Lancets into Lancing Device...11 Quality Control Testing...13

User s Manual Please read this User s Manual thoroughly before using your blood glucose meter.

Blood Glucose and ß -Ketone Monitoring System. Owner s Manual

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

Multi User Model. Product Overview

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use

VOICE. Blood Glucose Monitoring System. Owner s Manual

User s Manual Please read this User s Manual thoroughly Before using your blood glucose meter

EasyPlus mini Self-Monitoring Blood Glucose System. User s Manual. Please read this User s Manual thoroughly before using your blood glucose meter.

Title/Description: Point of Care Glucose Testing-Waived Department: Organization Wide Personnel: All Effective Date: November 29, 2016 Revised:

Skills workshop: Screening tests for syphilis

PRIMA Lab SA Via Antonio Monti Balerna Switzerland 0041 (0) primahometest.com

Blood Glucose Monitoring System

Owner s Booklet. 24/7 Customer Care English or Spanish Manufactured by:

Prodigy Talking Meter Owner s Manual. Dear Prodigy Owner:

GlucoCheck BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL

EME. Self-Monitoring Blood Glucose System. Quick Reference Guide

INTRODUCTION: McKesson TRUE METRIX PRO Professional Monitoring Blood Glucose Meter

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY AND INSTRUMENT COMBINATION TEMPLATE

Point of Care Testing for INR using CoaguChek XS Plus

METHOD FOR THE MEASUREMENT OF BEDSIDE TROPONIN T (cobas h232)

Mouse C-Peptide ELISA Kit

EasyMax N Self-Monitoring Blood Glucose System. User s Manual. Please read this User s Manual thoroughly before using your blood glucose meter.

Polymer Technology Systems, Inc. CardioChek PA Comparison Study

User Instruction Manual. Read this User Instruction Manual carefully before you start testing.

EasyPlus mini Self-Monitoring Blood Glucose System. User s Manual. Please read this User s Manual thoroughly before using your blood glucose meter.

If you have questions or simply want more information, please call your veterinarian or visit our website at

Blood Glucose Monitoring System

Specimen Collection Policies

Blood Glucose Monitoring System USER GUIDE. AW A Rev. date: 04/2010. Downloaded from manuals search engine

Transcription:

HemoCue Hb 201 + METHOD AND SAMPLE COLLECTION 1. PURPOSE AND SCOPE The purpose of this document is to describe the procedure for performing a Haemoglobin (Hb) test using the HemoCue Hb 201 + analyser. The HemoCue Hb 201 + meter can be used by healthcare professionals for measuring Hb. This method is to be used for the determination of haemoglobin in venous, arterial or capillary whole blood using the HemoCue Hb 201 + meter. 2. HAZARDS Patient Samples All patient samples should be treated as potentially infectious and handled appropriately. Standard precautions should be employed. Personal Protective Equipment (e.g. gloves and safety glasses) should be worn when processing samples, quality control testing and maintenance procedures. 3. CLINICAL SIGNIFICANCE Anaemia is defined as a low concentration of haemoglobin. Haemoglobin is the main component of red blood cells (RBCs) that transports oxygen from the lungs to other tissues and then returns carbon dioxide from the body to the lungs for removal. Anaemia occurs when RBCs are lost through excessive bleeding, if the bone marrow fails to produce enough RBCs or when there is premature destruction of RBCs in the circulation. Symptoms of anaemia depend on the aetiology but commonly include fatigue, muscle weakness, shortness of breath, rapid heartbeat and pale skin. Anaemia can be caused by vitamin or mineral deficiencies particularly of iron, vitamin B12 and folic acid. Anaemia can also be a result of underlying diseases such as cancer, rheumatoid arthritis, human immunodeficiency virus/acquired immunodeficiency syndrome (HIV/AIDS) and chronic kidney disease. In approximately 25% of cases no cause can be identified. Treatment for anaemia is based on the underlying cause and usually involves dietary changes, nutritional supplements and medications such as epoetin for patients with chronic kidney disease or cancer-related anaemia. In severe cases of anaemia, blood transfusions may be necessary. 1

4. TEST PRINCIPLE Within the microcuvette, sodium deoxycholate haemolyses the red blood cells releasing haemoglobin. Sodium nitrite then converts the haemoglobin to methemoglobin which, together with sodium azide, gives azide methemoglobin. The absorbance of the sample is measured at two wavelengths (570 and 880 mm) in order to compensate for turbidity in the sample. The haemoglobin level is then calculated by the meter and displayed on the screen. 4.1 Interference Mixing samples for extended periods can produce increased oxygen pressure and viscosity that may give false results. Values above 235 g/l must be confirmed using a suitable laboratory method. Following substances have not been found to interfere: Acetaminophen (1322.8 umol/l), ascorbic acid (170.3 umol/l), conjugated bilirubin (648.2 umol/l), unconjugated bilirubin (648.2 umol/l), creatinine (2.65 mmol/l), ibuprofen (1.94 mmol/l), leukocytes (600 x 10 9 /L), lipaemia (intralipid 4000mg/L, triglycerides 11.3 mmol/l), salicylic acid (36.2 umol/l), tetracycline (20 mg/dl), thrombocytes (2100 x 10 9 /L), urea (178.5 mmol/l), uric acid (1.19 mmol/l) and ph between 6.3 9.0 have not been found to interfere with the system. 4.2 Accuracy The results of the comparison studies between the HemoCue Hb 201 + system and the International Council for Standardization in Haematology method (ICSH) 3 are summarized in the table below. The study was performed on four HeomoCue Hb 201 + Analyzer which had not been recalibrated during the study period. Study N Min g/dl Max g/dl Regression line Correlation coefficient (r ) 1 498 4.1 20.5 Y=1.009X 0.008 0.998 2 103 9.0 17.7 Y=0.971X + 0.584 0.934 1=ICSH (Cyanmethemoglobin method), venous EDTA blood, multicenter study 2=ICSH (Cyanmethemoglobin method), capillary blood 4.3 Precision Within-run precision was determined according to the NCCLS Document EP5- A 5. The results given below in Within-run precision and Total precision come from 1 batch of HemoCue Hb 201 Microcuvettes and 5 HemoCue Hb 201+ Analyzers. No recalibration was performed during the analyzing period. Commercially available controls at 2 different leves were used. The hemoglobin concentration was measured in duplicate twice a day, morning and afternoon, during 20 consecutive days. 2

Control Level N x g/dl Within-run Precision SD g/dl Within-run Precision CV % Total Precision SD g/dl Total Precision CV % 1 400 7.70 0.057 0.74 0.100 1.30 2 400 15.36 0.078 0.51 0.109 0.71 Additionally, a study has been performed to determine the precision using fresh blood samples. The study was performed on venous whole blood samples tested in duplicate. 5. INSTRUMENT Product specifications 5.1 Operating and technical conditions Temperature range Relative humidity Position Measurement range Test time Memory Barcode scanner 15-30 C <90% (non-condensing) Place meter on a level, vibration-free surface 0-256 g/l 15-60 seconds 600 test results with date and time Interface The instrument is made for continuous mode Battery operation No Four AA batteries or power adapter recommended by HemoCue or CE marked adapter Mains connection Power supply adapter: Input: 100-240 V / 50-60Hz / < 500 ma Automatic power-off To turn off the analyser press and hold the left button until the display reads OFF and becomes blank 3

Dimensions Weight 85 x 160 x 43 mm 350g 5.2 Storage and transport conditions Temperature range Relative humidity 6. SPECIMEN REQUIREMENTS 15-30 C <90% (non-condensing) 6.1 Sample Material Venous or arterial blood is recommended for use on the HemoCue Hb instrument. Bloods must be collected into an EDTA or heparin tube. Capillary samples can be used but results should be interpreted with caution. Venepuncture (see suitable anticoagulants above) If the blood has been stored in a refrigerator it must be allowed to reach room temperature before analysis. Haemoglobin remains unchanged for days, provided that the blood does not become infected. Capillary blood (from finger prick) Wash hand with warm soapy water and dry thoroughly prior to collecting samples Capillary samples can be used but should be interpreted with caution as inaccurate results may be produced due to poor circulation. If the result does not fit the clinical picture, repeat using a venous sample. 7. CARTRIDGES/REAGENTS 7.1 Storage and handling The microcuvettes are stored at room temperature. Do not refrigerate. Individually packaged microcuvettes are stable until their expiry date. The microcuvette is for single use only. 8. CALIBRATION The HemoCue Hb 201 + instrument is calibrated against the international reference method for haemoglobin determination, ICSH 3. 9. QUALITY CONTROL Quality control material (perform as per your organisation protocol) Accurately testing known levels of haemoglobin ensures that the system and your technique used in testing give accurate results on patient tests. The 4

control solutions have defined (known) values. The results for these solutions must first fall within a certain acceptable range in order to allow valid patient testing. A quality control test should be performed every time a new shipment of test cuvettes are received, when a new lot number of test cuvettes are used, if the clinical picture does not correlate with the patient test results, after major maintenance, and at a minimum of once a month. Enrolling in an External Quality Assurance Program is encouraged to objectively compare results with other users using the same method of testing. If an External Quality Assurance Program is not available, monthly lab comparison is encouraged. 9.1 Internal quality control The HemoCue Hb 201 + uses the HemoTrol quality control solutions (three levels), each with a known haemoglobin concentration. Quality control material should be stored refrigerated at all times when not in use (2-8ºC). The control solution is stable for 30 days after opening or until the expiry date (whichever occurs first). 9.2 Performing the Test Remove vials from the refrigerator for 15 minutes to come to room temperature Roll the vial back and forth for 20-30 seconds. Occasionally invert the vial to mix the control solution. Mix vigorously, but do not shake. Continue to mix in this manner until the red cells are completely suspended. Vials stored for a long time may require extra mixing. Gently invert the vial 8-10 times immediately before sampling Remove the cap from the vial. Dispense a drop of control solution on to a hydrophobic surface e.g. plastic film or inside of the microcuvette package Fill the microcuvette in one continuous process. Place the microcuvette in the analyser. The result will be displayed on the instrument when the test is complete. Ensure this falls within the expected range indicated on the insert sent with your control vial. If the result does not fall within the expected range, repeat the test. 5

9.3 Laboratory Comparison If your policy states you must perform laboratory comparison, then perform a venepuncture and test the sample on the HemoCue Hb 201 + and send it to the laboratory for comparison. Record and compare the results ensuring they are in acceptable range for your organisation 10. TEST PROCEDURE 10.1 Performing the Test Collecting the sample Turn on the instrument. After start-up the cuvette holder should be in its loading position. The display will show three flashing dashes and the HemoCue symbol. If using a venous or arterial sample, mix the tube well by inverting 8-10 times before testing. Place a drop of blood on to a hydrophobic surface e.g. plastic film, or inside of the microcuvette package and fill the microcuvette in one continuous process. Follow the test procedure from Applying blood to the cuvette. If using capillary samples, results should be interpreted with caution. Make sure the patient s hand is warm and relaxed. Use only the middle or ring finger for sampling and avoid fingers with rings on. Clean finger with disinfectant and allow to dry. Using your thumb, lightly press the finger from the top of the knuckle towards the tip. This stimulates the blood flow towards the sampling point. For best blood flow and least pain sample at the side of the fingertip, not in the centre. Whilst pressing lightly towards the fingertip, prick the finger using a lancet Wipe away the first two or three drops of blood. Re-apply light pressure towards the fingertip until another drop of blood appears. When the drop is large enough, fill the microcuvette in one continuous process, filling from the tip of the microcuvette. DO NOT REFILL. 6

Inserting the cuvette Wipe off excess blood on the outside of the microcuvette tip using a tissue. Make sure no blood is drawn out of the microcuvette during this procedure. Look for air bubbles in the filled microcuvette. If bubbles are present take a new sample. Small bubbles around the edge can be ignored. Inserting cuvette into the meter Place the filled microcuvette in the cuvette holder. Testing should be performed within 10 minutes from filling the microcuvette. Push the cuvette holder to its measuring position. During the measurement, the hourglass symbol appears on the screen. After 15-60 seconds the haemoglobin value of the sample is displayed. The result will remain on the display as long as the cuvette holder is in the measuring position. When operating on battery power the analyser will automatically turn off after approximately 5 minutes. Once the test is completed, discard the used microcuvette in the hazard bin. 11. RESULTS Measuring range The instrument has a measuring range of 0 256 g/l. Results above 256 g/l are displayed as HHH. Accessing previous results The analyser automatically stores 600 results. When the memory is full the analyser will automatically overwrite the oldest result. The most recent result in the memory is displayed first Press the left or right button to scroll backwards or forwards between the results. The stored values are shown in the display. When the button is held down the user can see the order of the results, the most recent 7

measurement is always number 1 and when the button is released the result is shown. Reference Range Adult males 130 170 g/l Adult females 120 150 g/l Infants, after neonatal period 110 140 g/l Children, two years to teenage: gradual increase to adult normal. Additional information for healthcare professionals If the haemoglobin results do not reflect the patient s clinical symptoms, or seem unusually high or low, perform a control test. If the control test confirms that the system is working properly, repeat the test. If the repeated result still seems unusual, follow facility guidelines for further action. Your policy may encourage sending the specimen to the laboratory for testing. 12. MAINTENANCE 16.1 Cleaning the cuvette holder At the end of each day s use, remove the cuvette holder and clean with alcohol or a mild soap solution. The cuvette holder can also be autoclaved. It is important that the holder is completely dry before being replaced in the meter. 16.2 Cleaning the optronic unit Clean the optronic unit using the HemoCue Cleaner when directed to do so by an error message. Check that the analyser is turned off. The display should be blank. Pull the cuvette holder out to its loading position. Use a pointed object to carefully depress the small catch positioned in the upper right corner of the cuvette holder. Whilst keeping the catch depressed, carefully pull the cuvette holder in the direction in which the handle of the cuvette holder is pointing. Clean the cuvette holder with alcohol or mild detergent. 8

Push the HemoCue Cleaner swab into the opening of the cuvette holder. Pull out and push in 5 10 times. If the swab is stained, repeat with a new swab. Stop when the swab comes out clean. Wait 15 minutes before re-using the analyser. Replace the cuvette holder. The cover may be cleaned with alcohol or a mild soap solution. 13. REFERENCE SOURCE OF METHOD Adapted from the method described in the HemoCue Hb 201 + manual and HemoCue Hb 201 + Microcuvette package insert. 9