Tangential volumetric modulated arc therapy technique for left-sided breast cancer radiotherapy

Similar documents
Epworth Radiation Oncology

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

Intensity-Modulated Radiotherapy, Rapid Arc and Threedimensional Conformal Radiotherapy for Breast Cancer. Robert Lumsden

Guang-Hua Jin 1,2, Li-Xin Chen 1*, Xiao-Wu Deng 1, Xiao-Wei Liu 2, Ying Huang 1 and Xiao-Bo Huang 1

Is there a preferred IMRT technique for left-breast irradiation?

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

Variation In Mean Heart Dose By Treatment Plan Optimization During Radiotherapy For Left Sided Breast Cancer

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Volumetric Modulated Arc Therapy in a Large Body Habitus Patient with Left Breast Cancer: A Dosimetric Study

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

Address for Correspondence: Department of Medical Physics, Khwaja Yunus Ali University, Enayetpur, Sirajgonj ,

Dosimetric analysis of tangent-based volumetric modulated arc therapy with deep inspiration breath-hold technique for left breast cancer patients

Tangent field technique of TomoDirect improves dose distribution for whole-breast irradiation

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

Elective breast radiotherapy including level I and II lymph nodes: A planning study with the humeral head as planning risk volume

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

The Impact of Image Guided Radiotherapy in Breast Boost Radiotherapy

162 Popescu et al.: Couch gantry arc in partial breast 162

Protocol of Radiotherapy for Breast Cancer

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction

VOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

Clinical experience with TomoDirect System Tangential Mode

Received 24 September 2015; accepted 7 November 2015; published 10 November 2015

The choice of multi beam IMRT for whole breast radiotherapy in early stage right breast cancer

Fuli Zhang, Weidong Xu, Huayong Jiang, Yadi Wang ( ), Junmao Gao, Qingzhi Liu

REVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria

Correspondence should be addressed to Richard L. Bakst;

Chest wall desmoid tumours treated with definitive radiotherapy: a plan comparison of 3D conformal radiotherapy, intensitymodulated

Katherine S. Chen 1, Scott M. Glaser 1,2, Allison E. Garda 3, John A. Vargo 2, M. Saiful Huq 1,2, Dwight E. Heron 1,2 and Sushil Beriwal 1,2,4*

Dosimetric Comparison of Intensity-Modulated Radiotherapy versus 3D Conformal Radiotherapy in Patients with Head and Neck Cancer

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

Tangent-based volumetric modulated arc therapy for advanced left breast cancer

Influence of different boost techniques on radiation dose to the left anterior descending coronary artery

Three dimensional conformal radiotherapy for synchronous bilateral breast irradiation using a mono iso-center technique

Statistical Analysis and Volumetric Dose for Organ at Risk of Prostate Cancer

Defining Target Volumes and Organs at Risk: a common language

Left Breast Cancer Treated in Isocentric Lateral Decubitus (ILD) Position: An Alternative Technique Sparing Organs at Risk (OAR)

Corporate Medical Policy

VMAT plans for treatment prostate cancer: Dosimetric verifications and comparison with 3D-CRT and IMRT

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

Reproducibility of deep inspiration breath hold for prone left-sided whole breast irradiation

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Cardiovascular disease after radiation therapy

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

Tomohisa FURUYA*, Satoru SUGIMOTO, Chie KUROKAWA, Shuichi OZAWA, Kumiko KARASAWA and Keisuke SASAI

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

OPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING

3D-CRT Breast Cancer Planning

Morphological Factors and Cardiac Doses in Whole Breast Radiation for Left-sided Breast Cancer

PRONE BREAST WHAT S THE BIG DEAL? Rachel A. Hackett CMD, RTT

Relationship of segment area and monitor unit efficiency in aperture-based IMRT optimization

Quality assurance of volumetric modulated arc therapy using Elekta Synergy

7/28/2012. Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures***

To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence

The Physics of Oesophageal Cancer Radiotherapy

Editorial Process: Submission:11/14/2017 Acceptance:07/31/2018

Katarzyna Pudełek, MD, PhD, Jacek Pudełek, MD, PhD, Sergiusz Nawrocki, MD, PhD, Assoc. Professor of the Medical University of Silesia

Intensity modulation techniques for spinal treatments and on-line VolumeView TM guidance

Prone versus supine position for adjuvant breast radiotherapy: a prospective study in patients with pendulous breasts

Computerized Treatment Planning in Radiation Therapy of Intact Breast: Influence of Number of CT-Cuts

VMAT planning study in rectal cancer patients

Advances in external beam radiotherapy

ISSN: X (Print) X (Online) Journal homepage:

A dosimetric evaluation of VMAT for the treatment of non-small cell lung cancer

Potential benefits of intensity-modulated proton therapy in head and neck cancer van de Water, Tara Arpana

Dose escalation for NSCLC using conformal RT: 3D and IMRT. Hasan Murshed

Dosimetric comparison of preoperative single-fraction partial breast radiotherapy techniques: 3D CRT, noncoplanar IMRT, coplanar IMRT, and VMAT

Does the IMRT technique allow improvement of treatment plans (e.g. lung sparing) for lung cancer patients with small lung volume: a planning study

Leila E. A. Nichol Royal Surrey County Hospital

Evaluation of a new predictor of heart and left anterior descending artery dose in patients treated with adjuvant radiotherapy to the left breast

Post-Lumpectomy Radiation Techniques and Toxicities

Protocol of Radiotherapy for Small Cell Lung Cancer

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast

Correlation between intensity modulated radiotherapy and bone marrow suppression in breast cancer

Silvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

Electron Beam ET - Reloaded Therapy - Reloaded

Post-mastectomy radiotherapy: recommended standards

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

IMRT Planning Basics AAMD Student Webinar

COMPARISON OF THREE CONCOMITANT BOOST TECHNIQUES FOR EARLY-STAGE BREAST CANCER

SIMPLE IMPLEMENTATION OF A DIBH TANGENTIAL IMRT TECHNIQUE FOR LEFT-SIDED BREAST CANCER

Radiobiological Impact of Planning Techniques for Prostate Cancer in Terms of Tumor Control Probability and Normal Tissue Complication Probability

Case Study. Institution Farrer Park Hospital

Guidelines for the treatment of Breast cancer with radiotherapy v.1.0 September 2017

Borges C 1, Zarza- Moreno M 2, Teixeira N 2, Vaz P 3 1

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Evaluation of three APBI techniques under NSABP B-39 guidelines

Treatment of exceptionally large prostate cancer patients with low-energy intensity-modulated photons

Collimator rotation in volumetric modulated arc therapy for craniospinal irradiation and the dose distribution in the beam junction region

Citation for published version (APA): Laan, H. P. V. D. (2010). Optimising CT guided radiotherapy for breast cancer Groningen: s.n.

Clinical implications of the ISC technique for breast cancer radiotherapy and comparison with clinical recommendations

Evaluation of volumetric modulated arc therapy for postmastectomy treatment

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Transcription:

Virén et al. Radiation Oncology (2015) 10:79 DOI 10.1186/s13014-015-0392-x RESEARCH Open Access Tangential volumetric modulated arc therapy technique for left-sided breast cancer radiotherapy Tuomas Virén *, Janne Heikkilä, Kimmo Myllyoja, Kristiina Koskela, Tapani Lahtinen and Jan Seppälä Abstract Background: The aim of the present study was to introduce a new restricted tangential volumetric modulated arc therapy (tvmat) technique for whole breast irradiation and compare its dosimetric properties to other currently used breast cancer radiotherapy techniques. Method: Ten consecutive women with left-sided breast cancer were enrolled in this retrospective study. Four treatment plans were generated for each patient: 1) standard tangential field-in-field (FinF), 2) tangential intensity modulated radiotherapy (timrt), 3) tangential VMAT (tvmat) with two dual arcs of 50-60 and 4) continuous VMAT (cvmat) with a dual arc of 240. The plans were created with Monaco (timrt, tvmat and cvmat) and Oncentra (FinF) treatment planning systems. Results: With both VMAT techniques significantly higher cardiac avoidance, dose coverage and dose homogenity were achieved when compared with FinF or timrt techniques (p < 0.01). VMAT techniques also decreased the high dose areas (above 20 Gy) of ipsilateral lung. There were no significant differences in the mean dose of contralateral breast between the tvmat, timrt and FinF techniques. The dose coverage (V47.5 Gy) was greatest with cvmat. However, with cvmat the increase of contralateral breast dose was significant. Conclusions: The present results support the hypothesis that the introduced tvmat technique is feasible for treatment of left-sided breast cancer. With tvmat dose to heart and ipsilateral lung can be reduced and the dose homogeneity can be improved without increasing the dose to contralateral breast or lung. Keywords: Radiotherapy, Breast cancer, VMAT, IMRT, Low dose volume * Correspondence: Tuomas.Viren@kuh.fi Cancer Center, Kuopio University Hospital, PO Box 100, FI-70029 Kuopio, Finland Background Adjuvant radiotherapy (RT) after breast-conserving surgery of breast cancer decreases the rate of recurrence and increases the overall survival [1]. Unfortunately, a number of patients develop radiation related complications such as breast fibrosis, changes in the breast appearance and late pulmonary and cardiovascular complications [2-4]. Although the frequency of radiationinduced complications has decreased along the development of RT techniques, novel methods are needed for effective reduction of dose to heart and ipsilateral lung. Dose inhomogeneity in treated breast has been reported to be the most important predictor of RTinduced toxicities such as fibrosis, erythema, moist desquamation and oedema [5]. With conventional tangential field-in-field (FinF) or wedge field techniques the dose inhomogeneities are usually unavoidable, especially in large-breasted patients. Furthermore, the increased use of hypofractionation has also increased the requirement for the dose homogeneity in breast cancer RT [6]. Simultaneously, to avoid radiation induced pulmonary complications dose volume constraints for ipsilateral lung must also be employed [5,7]. In addition to pulmonary complications, more and more concern has been addressed on cardiac mortality related to left-sided whole breast irradiation (WBI) [1,4]. Furthermore, sparing of left anterior descending coronary artery (LAD) has been recommended to avoid late coronary complications [8]. Since recommendations on safe dose levels to 2015 Virén et al.; licensee BioMed Central. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Virén et al. Radiation Oncology (2015) 10:79 Page 2 of 8 the heart are not available, techniques that minimize the cardiac exposure are needed [9]. Static tangential field or intensity modulated radiotherapy (IMRT) techniques are generally used for WBI. Tangential field techniques usually consist of two opposing fields and the dose intensity modulation is limited from these directions. As a consequence the avoidance of heart and ipsilateral lung might lead to compromising the target volume coverage and also result in higher dose inhomogeneities. IMRT has been shown to improve target dose coverage and minimize the dose in organs at risk [10,11]. However, IMRT techniques with multiple treatment fields have been reported to increase the low dose volumes in contra- and ipsilateral lung and contralateral breast [12,13]. Consequently, a fear of increasing the risk for second cancer has hindered the use of IMRT techniques in WBI. Volumetric modulated arc therapy (VMAT) is a relatively new technique based on simultaneous optimization of multi leaf collimator (MLC), gantry rotation and dose rate. So far the VMAT techniques have been applied for WBI with varying results [14-16]. When compared to IMRT greater target volume coverage and homogeneity have been achieved with VMAT. In addition, VMAT has reduced ipsilateral lung doses when compared to conventional tangential field techniques [15]. However, the earlier VMAT techniques have been reported to increase the mean dose of contralateral lung, contralateral breast and heart as compared to the tangential techniques. Thus it has been concluded that the studied VMAT techniques should not be used for WBI [14]. In the previous dosimetric studies full or continuous partial arcs have been used in VMAT treatment planning [14-16]. Analogous to multiple-field IMRT plans, the use of full arcs consequently increases the irradiated volume. The aim of the present study was to introduce and dosimetrically evaluate a restricted tangential VMAT technique for left-sided breast cancer. We hypothesize that with the proposed tangential VMAT (tvmat) technique the dose homogeneity within target volume can be increased. Furthermore, we hypothesize that radiation dose to heart and lung can be decreased without increasing low dose volume, especially in contralateral breast, when compared to conventional tangential field techniques. Method Patients Ten patients (age 65 ± 6 years) with left-sided breast cancer without nodal involvement were selected in this retrospective study. The study was approved by the Research Ethics Committee of Northern Savo Hospital District. The patients were imaged with a CT scanner (Toshiba Aquilion LB, Toshiba Medical Systems Co., Tochigi, Japan) in treatment position (supine, arms up). CT images were acquired from the level of mandible to the basis of lungs with a slice thickness of 2 mm. Target and OAR delineation The delineation of the clinical target volume (CTV) was based on the RTOG guidelines (http://www.rtog.org/ corelab/contouringatlases.aspx). A margin of 5 mm was added to the CTV resulting in the planning target volume (PTV). The volumes outside the body contour and insidethelungwereexcludedfromtheptv.furthermore, for the plan evaluation and normalization purposes, a margin of 5 mm from skin surface was excluded from the PTV (resulting PTV in ). PTV in was also used as a target volume in the optimization of VMAT and IMRT plans to avoid overdosing the skin. Organs at risks (OAR) defined in this study were contra- and ipsilateral lung, heart, LAD, contralateral breast and normal tissue which was defined by excluding the PTV from the body surface (Body-PTV). Dose objectives and constraints The prescription dose was 50 Gy in 25 fractions. The primary aim in treatment planning was to achieve 98% dose coverage of 47.5 Gy (V47.5) in the PTV. VMAT and IMRT plans were optimized in Monaco TPS in a constrained mode and biological cost functions were used as constraints. The volumes of doses 30 Gy, 25 Gy and 2 Gy (V30, V20, V2) were minimized for heart and LAD. For ipsilateral lung volumes of doses 20 Gy, 10 Gy and 5 Gy (V20, V10 and V5) were minimized. For contralateral lung and breast the doses were optimized to be less than 5 and 2 Gy, respectively. The objective functions were specified individually for each patient to accomplish the best achievable treatment plan. For FinF plans the treatment planning goal was to achieve the same dose objectives used in the IMRT and VMAT planning. Treatment planning Treatment plans were created for Elekta Infinity accelerator (Elekta AB, Stockholm, Sweden) with 5 mm Agility MLC. The treatment energies (either 6 or 10 MV) were selected according to the size of the PTV. Four separate treatment plans with an identical isocenter were created to each patient as shown in Figure 1: 1) a standard tangential FinF, 2) a dynamic IMRT with two static tangential fields (timrt), 3) tangential VMAT (tvmat) with two tangential dual arcs of 50-60 and 4) continuous VMAT (cvmat) treatment plan with one dual arc of 240. The tvmat, cvmat and timrt plans were generated using Monaco treatment planning system (TPS) (version 3.30.01, Elekta AB). To determine optimal arc configuration for tvmat and cvmat plans several plans with different plan parameter (e.g. start and stop angles of the arcs) were generated and beam

Virén et al. Radiation Oncology (2015) 10:79 Page 3 of 8 Figure 1 Typical beam arrangements for FinF (A), timrt (B), tvmat (C) and cvmat (D). configuration that produced the best result were selected to the study. Surface margin (e.g. the inner margin from skin surface that is excluded from the optimization) was set to 0.5 cm. Minimum segment width of 1.0 cm and high fluence smoothing was used in the optimization. To avoid under dosing the skin optimized radiation fluences were extended 2 cm outside the body surface using auto flash operation available in Monaco TPS. Maximum number of control points per plan was set to 170. A standard deviation of 0.5% was used in Monte Carlo (MC) dose calculation with a dose grid of 3.0 mm. The 3D-CRT FinF plans were generated in Oncentra TPS (version 4.3.0.410, Elekta AB) with collapsed cone convolution (CCC) dose calculation algorithm with a dose grid of 3.0 mm. Doses to the OARs were minimized without compromising the PTV coverage as recommended by QUANTEC [17]. All treatment plans were normalized to the mean dose of PTV in. Plan analysis Dose volume histograms (DVH) of the treatment plans were used in analyzing target coverage and doses to the OAR s. In addition, the plan qualities were compared by the homogeneity index (HI) and conformity index (CI). The plan CI, defined by Paddick [18], is given by CI ¼ TV PIV 2 ðtv PIVÞ ; where the TV PIV is the volume of the PTV in covered by the prescription isodose, TV is the volume of the PTV in and PIV the total volume covered by the prescription isodose. The HI was defined as ð HI ¼ D 1 D 98 Þ ; D P where D 1 is the minimum dose in 1% of the PTV in,d 98 is the minimum dose in 98% of the PTV in and D P is the prescription dose. Statistical analysis One way analysis of variance with least significant difference post-hoc test (LSD) was conducted using SPSS software (version 19.0.0.2, IBM, USA) to evaluate the significance of difference between the dosimetric parameters calculated from the treatment plans. A p-value <0.05 was considered significant. Results The VMAT and the IMRT techniques achieved significantly higher dose homogeneity (lower HI-value, p < 0.01) when compared with the FinF technique (Table 1). Furthermore, with the both VMAT techniques the dose homogeneity was significantly higher as compared to timrt (p < 0.05). No significant difference in CI was detected between the VMAT, IMRT or FinF techniques. The dose coverage (V47.5 Gy) was significantly superior with VMAT techniques as compared with FinF and timrt techniques (p < 0.05). There was no statistical difference in V47.5, HI or CI between tvmat and cvmat techniques.

Virén et al. Radiation Oncology (2015) 10:79 Page 4 of 8 Table 1 Mean values and standard deviations (n = 10) of the dosimetric parameters for the different techniques studied tvmat cvmat timrt FinF PTV D1cm 3 (Gy) 53.4 ± 0.5 53.3 ± 0.4 53.7 ± 0.5 53.5 ± 0.6 V47.5 (%) 97.8 ± 0.8 98.1 ± 1.0 96.3 ± 2.0 91.4 ± 2.4 HI 0.10 ± 0.01 0.10 ± 0.01 0.12 ± 0.02 0.14 ± 0.01 CI 0.50 ± 0.03 0.50 ± 0.04 0.45 ± 0.05 0.47 ± 0.09 Lung, Ipsilateral V20 (%) 18.1 ± 5.3 15.3 ± 4.6 21.6 ± 4.0 21.4 ± 3.7 V10 (%) 25.3 ± 5.6 23.4 ± 5.6 26.2 ± 4.3 25.7 ± 3.8 V5 (%) 36.9 ± 5.4 35.5 ± 5.6 33.3 ± 4.3 32.0 ± 3.6 Mean dose (Gy) 9.6 ± 2.1 8.7 ± 1.7 10.9 ± 1.8 10.4 ± 1.5 Lung, Contralateral Mean dose (Gy) 0.9 ± 0.1 1.6 ± 0.7 0.7 ± 0.1 0.7 ± 0.1 Heart V30 (%) 5.7 ± 6.0 3.4 ± 3.9 13.9 ± 6.8 15.2 ± 6.9 V25 (%) 8.2 ± 6.9 5.0 ± 5.3 15.4 ± 7.1 16.4 ± 7.4 V2 (%) 60.8 ± 18.8 68.4 ± 22.3 61.3 ± 14.4 57.9 ± 14.4 Mean dose (Gy) 6.3 ± 3.0 5.5 ± 2.9 9.1 ± 3.4 9.1 ± 3.5 LAD V30 (%) 43.1 ± 29.5 32.0 ± 27.3 67.8 ± 19.9 79.7 ± 8.1 V25 (%) 55.0 ± 27.8 40.3 ± 28.4 72.2 ± 15.1 81.2 ± 7.5 Mean dose (Gy) 24.3 ± 8.0 20.4 ± 8.7 34.4 ± 7.0 37.9 ± 3.6 Breast, Contralateral V2 (%) 10.2 ± 7.0 53.0 ± 27.1 11.1 ± 5.6 7.0 ± 4.8 Mean dose (Gy) 1.2 ± 0.3 2.6 ± 1.2 1.0 ± 0.4 1.0 ± 0.3 Normal tissue (Body-PTV) V53.5 (cm 3 ) 0.9 ± 1.1 0.4 ± 0. 5 8.5 ± 15.6 1.9 ± 4.1 V2 (%) 20.3 ± 4.6 30.4 ± 8.3 17.3 ± 2.8 15.9 ± 3.4 Mean dose (Gy) 3.3 ± 0.5 3.8 ± 0.6 3.3 ± 0.5 3.4 ± 1.1 Body Integral Dose (Gydm 3 ) 105.3 ± 43.4 113.5 ± 43.8 105.6 ± 43.8 99.3 ± 46.5 Significant cardiac (heart and LAD) dose sparing was achieved with VMAT techniques when compared to FinF or timrt (Table 1, Figure 2, Figure 3). With tvmat and cvmat the V30 and V25 volumes to the heart and LAD were significantly lower when compared to IMRT or FinF techniques (p < 0.05) (Table 1). Furthermore, the cvmat technique reduced the mean dose of the heart significantly when compared with timrt or FinF (p < 0.05). Slight but non-significant reduction of V2 of the heart was achieved with FinF as compared with that of tvmat, cvmat or timrt. Significant decrease in high dose volume (V20) and mean dose of ipsilateral lung was achieved with cvmat technique as compared with timrt or FinF plans (p < 0.01) (Table 1). Additionally, with tvmat technique the reduction of high dose volume to the lung was evident as compared with timrt and FinF (Figure 2, Figure 3). However, no statistically significant differences were found in V20, V10 or V5 volumes between tvmat, timrt or FinF techniques. cvmat increased the mean dose of the contralateral lung significantly when compared with other techniques (p < 0.01). The difference was non-significant between tvmat, timrt and FinF. The difference in contralateral breast mean dose between tvmat, timrt and FinF techniques was nonsignificant (Table 1, Figure 3). However, the cvmat technique increased the mean dose of contralateral breast significantly (p < 0.01). No significant differences were detected in the low dose volumes (V2) to normal

Virén et al. Radiation Oncology (2015) 10:79 Page 5 of 8 Figure 2 Average cumulative DVHs (n = 10) for the four different techniques studied. PTV in (A), contralateral breast (B), left anterior descending coronary artery (C), heart (D), ipsilateral lung (E), and contralateral lung (F). structures (Body-PTV) between tvmat, timrt or FinF techniques as with cvmat the increase was significant (p < 0.01, Table 1). No significant differences in mean dose to the normal structures or integral doses to body were detected between the techniques (Table 1). The average number of monitor units (MUs) with one

Virén et al. Radiation Oncology (2015) 10:79 Page 6 of 8 Figure 3 Typical dose distributions for one patient planed with (A) FinF, (B) timrt, (C) tvmat and (D) cvmat techniques. fraction were on average 629 ± 93 MU, 678 ± 98 MU, 283 ± 37 MU and 233 ± 5 MU with tvmat, cvmat, timrt and FinF, respectively. Discussion In this dosimetric study two different VMAT techniques were investigated for left-sided breast cancer radiotherapy and were found to increase the dose homogeneity when compared with timrt and FinF. Similarly, significant increases in dose homogeneity and coverage have been reported as IMRT or VMAT techniques have been compared with conventional techniques [13,14,19]. Correspondingly with the previous studies high doses to heart and LAD was avoided with the studied VMAT techniques [14,20]. As the mean dose and doses of 25 and 30 Gy to heart have been reported to be detrimental [4,17,21], it would support the potential of VMAT techniques in WBI. In this study the high dose volumes in ipsilateral lung were decreased by using the VMAT techniques. Similar results have also been reported in previous studies in which VMAT or IMRT techniques have been compared with conventional tangential techniques [11,15,16]. However, when using the VMAT or IMRT techniques without restricting the field directions (as with cvmat) significant increase in low dose volume has also been observed. Fear of increasing the low dose volume to lungs and contralateral breast is probably the main reason for the delayed clinical implementation of IMRT and VMAT techniques in WBI. As expected, increase in low dose volume (V5 and V2) of lungs and contralateral breast was detected with cvmat plans when compared to tvmat, timrt or FinF. Since the IMRT fields in this study were limited to opposing tangential directions no significant differences were found in contralateral lung or breast doses between timrt and FinF techniques. Importantly, no significant differences in mean doses to contralateral lung, and breast were detected between tvmat and conventional tangential techniques. Furthermore, no significant differences were detected in integral dose or mean dose to normal tissue between the techniques. This indicates that there is no apparent elevation in the second cancer risk related to tvmat technique. Generally, mean doses to the heart, contralateral lung and breast reported in the present study are higher than those reported in some of the previous studies [11,14]. The main reason for this is the target delineation protocol used. In the current study the CTVs were delineated strictly based on the RTOG guidelines resulting in significantly larger target volumes (mainly to the medial direction) than we would have used clinically. However, an important conclusion from this study is that both the studied VMAT techniques decreased the heart doses when compared to conventional tangential techniques. One of the limitations of this study is that the possible movement of the breast during the treatment was not accounted for. However, in recent dosimetric study no significant differences were detected in the dose homogeneity between IMRT and tangential plans using a moving target [22]. In addition, the VMAT treatment plans in this study were optimized with low beam modulation avoiding sharp dose gradients inside the target volume thus minimizing the effect of breathing motion to the

Virén et al. Radiation Oncology (2015) 10:79 Page 7 of 8 dose distributions. It should be also noted that as two different dose calculation algorithms (CCC and MC) where used in the present study, part of the differences in the low dose areas might result from the accuracy of the used algorithms [23]. However, the dose distributions between the VMAT and IMRT treatment plans are directly comparable, since they were planned and calculated with the same TPS with the same dose calculation algorithm. In the present study patients were treated in supine position. To reduce the dose to ipsilateral lung and heart, and to increase the dose homogeneity in PTV prone treatment position has been proposed for patients with large or pendulous breasts [24]. In the recent studies, in which prone treatment position was compared with supine position, significant decrease in ipsilateral lung dose was reported [25,26]. However, no significant differences were detected in doses to heart between the treatment positions [25,26]. As the heart typically moves towards chest wall in prone position usage of VMAT techniques to decrease the dose to heart might be beneficial also in prone position. However, further studies are needed to evaluate the potential of VMAT techniques in prone treatment position. To further avoid the irradiation of heart deepinspiration breath-hold techniques have been implemented and introduced for WBI [27]. The use of VMAT techniques could even further decrease the doses to cardiac tissue and ipsilateral lung in deep-inspiration breath-hold treatments. Unfortunately, there are a number of patients that cannot hold their breath for long times or are having difficulties to manage the breathhold techniques. For those patients the VMAT techniques should definitely be considered to avoid irradiating high doses to heart. However, it should be noted that even if large heart doses are avoided by using breath-hold techniques significant increase in the dose coverage and homogeneity can be achieved with VMAT. The increase in dose homogeneity not only decreases the possibility of developing adverse effects in breast tissue but also allows the use of hypofractionation even for the patients with a large PTV. It should also be noted that with the restricted tvmat technique the low dose volume is not increased in contralateral breast. Conclusion The restricted tvmat technique is an effective method for achieving a homogeneous dose coverage simultaneously reducing doses to heart, LAD and ipsilateral lung. Although, the cvmat technique achieved the highest reduction of high dose volume in heart, LAD and ipsilateral lung, it also increased the low dose volumes of lung and contralateral breast. Since the tvmat technique does not increase the low dose volumes in the contralateral breast or lung and significantly increases the dose coverage and homogeneity, the tvmat technique could be a potential option for conventional WBI techniques. However, further studies evaluating the clinical outcome of treatments given with tvmat technique is needed to proof the clinical value of the technique. All patients included in the present study were treated with tvmat technique. Competing interests The authors declare that they have no competing interests. Authors contributions Authors TV, JH, KM, KK, TL and JS contributed to the conception and design of the study. Authors TV, JH, KM, KK and JS contributed to acquisition of data, or analysis and interpretation of data. All authors participated in the writing process. TV takes responsibility of the integrity of the work. All authors read and approved the final manuscript Received: 24 December 2014 Accepted: 25 March 2015 References 1. Clarke M, Collins R, Darby S, Davies C, Elphinstone P, Evans E, et al. Effects of radiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival: an overview of the randomised trials. Lancet. 2005;366:2087 106. 2. Mukesh MB, Harris E, Collette S, Coles CE, Bartelink H, Wilkinson J, et al. Normal tissue complication probability (NTCP) parameters for breast fibrosis: Pooled results from two randomised trials. Radiother Oncol. 2013;108:293 8. 3. Blom Goldman U, Wennberg B, Svane G, Bylund H, Lind P. Reduction of radiation pneumonitis by V20-constraints in breast cancer. Radiat Oncol. 2010;5:9. 4. Darby SC, Ewertz M, McGale P, Bennet AM, Blom-Goldman U, Brønnum D, et al. Risk of ischemic heart disease in women after radiotherapy for breast cancer. N Engl J Med. 2013;368:987 98. 5. Tortorelli G, Di Murro L, Barbarino R, Cicchetti S, Di Cristino D, Falco MD, et al. Standard or hypofractionated radiotherapy in the postoperative treatment of breast cancer: a retrospective analysis of acute skin toxicity and dose inhomogeneities. BMC Cancer. 2013;13:230. 6. Yarnold J, Bentzen SM, Coles C, Haviland J. Hypofractionated whole-breast radiotherapy for women with early breast cancer: myths and realities. Int J Radiat Oncol Biol Phys. 2011;79:1 9. 7. Yorke ED, Jackson A, Rosenzweig KE, Braban L, Leibel SA, Ling CC. Correlation of dosimetric factors and radiation pneumonitis for non-small-cell lung cancer patients in a recently completed dose escalation study. Int J Radiat Oncol Biol Phys. 2005;63:672 82. 8. Nilsson G, Holmberg L, Garmo H, Duvernoy O, Sjögren I, Lagerqvist B, et al. Distribution of coronary artery stenosis after radiation for breast cancer. J Clin Oncol. 2012;30:380 6. 9. Chung E, Corbett JR, Moran JM, Griffith KA, Marsh RB, Feng M, et al. Is there a dose response relationship for heart disease with low-dose radiation therapy? Int J Radiat Oncol Biol Phys. 2013;85:959 64. 10. Hurkmans CW, Cho BCJ, Damen E, Zijp L, Mijnheer BJ. Reduction of cardiac and lung complication probabilities after breast irradiation using conformal radiotherapy with or without intensity modulation. Radiother Oncol. 2002;62:163 71. 11. Hong L, Hunt M, Chui C, Spirou S, Forster K, Lee H, et al. Intensitymodulated tangential beam irradiation of the intact breast. Int J Radiat Oncol Biol Phys. 1999;44:1155 64. 12. Tsuchiya K, Kinoshita R, Shimizu S, Nishioka K, Harada K, Nishikawa N, et al. Dosimetric comparison between intensity-modulated radiotherapy and standard wedged tangential technique for whole-breast radiotherapy in Asian women with relatively small breast volumes. Radiol Phys Technol. 2014;7:67 72. 13. Dogan N, Cuttino L, Lloyd R, Bump E, Arthur DW. Optimized dose coverage of regional lymph nodes in breast cancer: the role of intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys. 2007;68:1238 50.

Virén et al. Radiation Oncology (2015) 10:79 Page 8 of 8 14. Jin G-H, Chen L-X, Deng X-W, Liu XW, Huang Y, Huang XB. A comparative dosimetric study for treating left-sided breast cancer for small breast size using five different radiotherapy techniques: conventional tangential field, filed-in-filed, Tangential-IMRT, Multi-beam IMRT and VMAT. Radiat Oncol. 2013;8:89. 15. Johansen S, Cozzi L, Olsen DR. A planning comparison of dose patterns in organs at risk and predicted risk for radiation induced malignancy in the contralateral breast following radiation therapy of primary breast using conventional, IMRT and volumetric modulated arc treatment technique. Acta Oncol. 2009;48:495 503. 16. Popescu CC, Olivotto IA, Beckham WA, Ansbacher W, Zavgorodni S, Shaffer R, et al. Volumetric modulated arc therapy improves dosimetry and reduces treatment time compared to conventional intensitymodulated radiotherapy for locoregional radiotherapy of left-sided breast cancer and internal mammary nodes. Int J Radiat Oncol Biol Phys. 2010;76:287 95. 17. Gagliardi G, Constine LS, Moiseenko V, Correa C, Pierce LJ, Allen AM, et al. Radiation dose-volume effects in the heart. Int J Radiat Oncol Biol Phys. 2010;76:S77 85. 18. Paddick IA. Simple scoring ratio to index the conformity of radiosurgical treatment plans, Technical note. J Neurosurg. 2000;93:S219 22. 19. Qiu J-J, Chang Z, Wu QJ, Yoo S, Horton J, Yin FF. Impact of Volumetric Modulated Arc Therapy Technique on Treatment With Partial Breast Irradiation. Int J Radiat Oncol. 2010;78:288 96. 20. Sakumi A, Shiraishi K, Onoe T, Yamamoto K, Haga A, Yoda K, et al. Single-Arc Volumetric Modulated Arc Therapy Planning for Left Breast Cancer and Regional Nodes. J Radiat Res. 2012;53:151 3. 21. Gagliardi G, Lax I, Söderström S, Gyenes G, Rutqvist LE. Prediction of excess risk of long-term cardiac mortality after radiotherapy of stage I breast cancer. Radiother Oncol. 1998;46:63 71. 22. Liu Q, McDermott P, Burmeister J. Effect of respiratory motion on the delivery of breast radiotherapy using SMLC intensity modulation. Med Phys. 2007;34:347 51. 23. Heikkilä J, Seppälä J, Virén T, Lahtinen T, Heikkilä J, Seppälä J, et al. Accuracy of contralateral breast doses using different treatment planning algorithms. Vienna, Austria: ESTRO 33 conference, EP-1550; 2014. 24. Merchant TE, McCormick B. Prone position breast irradiation. Int J Radiat Oncol Biol Phys. 1994;30(1):197 203. 25. Mulliez T, Speleers B, Madani I, De Gersem W, Veldeman L, De Neve W. Whole breast radiotherapy in prone and supine position: is there a place for multi-beam IMRT? Radiat Oncol. 2013;8:151. 26. Krengli M, Masini L, Caltavuturo T, Pisani C, Apicella G, Negri E, et al. Prone versus supine position for adjuvant breast radiotherapy: a prospective study in patients with pendulous breasts. Radiat Oncol. 2013;8:232. 27. Mast ME, Van Kempen-Harteveld L, Heijenbrok MW, Kalidien Y, Rozema H, Jansen WP, et al. Left-sided breast cancer radiotherapy with and without breath-hold: Does IMRT reduce the cardiac dose even further? Radiother Oncol. 2013;108:248 53. Submit your next manuscript to BioMed Central and take full advantage of: Convenient online submission Thorough peer review No space constraints or color figure charges Immediate publication on acceptance Inclusion in PubMed, CAS, Scopus and Google Scholar Research which is freely available for redistribution Submit your manuscript at www.biomedcentral.com/submit