The CON-SOT-LOT Test for Nonorganic Hearing Loss

Similar documents
Strategies Used in Feigning Hearing Loss

Technical Report: Distortion Product Otoacoustic Emissions That Are Not Outer Hair Cell Emissions DOI: /jaaa

MEASUREMENTS AND EQUIPMENT FOR AUDIOLOGICAL EVALUATIONS

Wheeler, K.S. M.Cl.Sc. (Aud) Candidate School of Communication Sciences and Disorders, U.W.O

HEARING CONSERVATION PROGRAM

CITY OF FORT BRAGG HEARING CONSERVATION PROGRAM

Clinical Forum. Detecting and Remediating External Meatal Collapse during Audiologic Assessment. Levi A. Reiter* Shlomo Silmant

Supplementary Online Content

Janet Doyle* Lena L. N. Wongt

Introduction to Audiology: Global Edition

Acoustic-Immittance Characteristics of Children with Middle-ear Effusion : Longitudinal Investigation

HEARING CONSERVATION PURPOSE

Contents. 1) Purpose ) Policy ) Definitions ) Procedure a) Requirements b) Noise standard... 4

Intrasubj ect Reliability of High-Frequency (9-14 khz) Thresholds : Tested Separately vs. Following Conventional-Frequency Testing

Model Safety Program

Recommended Procedure. Industrial Audiometry

Recommended Procedure. Industrial Audiometry

REFERRAL AND DIAGNOSTIC EVALUATION OF HEARING ACUITY. Better Hearing Philippines Inc.

Hearing Conservation Program

Table 6.3 Example of Effective Masking* Hearing Level of 1,000 Hz Tone

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.

Prediction of Aided Preferred Listening Levels for Hearing Aid Gain Prescription *

Benefit: Hearing Services and Hearing Aid Devices

Basic Audiogram Interpretation

Effects of Exercise Training on Hearing Ability

TOWN OF FAIRFIELD PUBLIC HEALTH NURSING. MANUAL: School Health APPROVED BY: Board of Health School Medical Advisor

Clinical Protocol. Clinical Masking for Audiometric Testing in Adults PURPOSE

Effect of intensity increment on P300 amplitude

AUBURN UNIVERSITY DEPARTMENT OF COMMUNICATION DISORDERS CMDS 8200 DIAGNOSTIC AUDIOLOGY (3 credit hours) SPRING 2015

Utility of Standard DPOAEs in the Evaluation of the Normal-Hearing Tinnitus Patient


Classification of magnitude of hearing loss (adapted from Clark, 1981; Anderson & Matkin, 1991)

Optimal Design: Bekesy Test for Mobile

Audiometric Techniques Program in Audiology and Communication Sciences Pediatric Audiology Specialization

Asymmetric Suprathreshold Speech Recognition and the Telephone Ear Phenomenon

Organisation Internationale de Métrologie Légale

Sandra Gordon-Salant Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742

The Impact of Presentation Level on SCAN A Test Performance

Hearing Conservation Program April 27, 2018

Newborn Hearing Thresholds Measured by Both Insert and Earphone Methods

Signals, systems, acoustics and the ear. Week 1. Laboratory session: Measuring thresholds

Verification of soft speech amplification in hearing aid fitting: A comparison of methods

The Relationship Between Recruitment and Masking

Proceedings of Meetings on Acoustics

General about Calibration and Service on Audiometers and Impedance Instruments

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

Benefit: Hearing Services and Hearing Aid Devices

Santa Clarita Community College District HEARING CONSERVATION PROGRAM. Revised

C HAPTER FOUR. Audiometric Configurations in Children. Andrea L. Pittman. Introduction. Methods

An efficient test protocol for identification of a limited, sensitive frequency test range for early detection of ototoxicity

Environmental Health & Safety Policy Manual

Hearing in Noise Test in Subjects With Conductive Hearing Loss

Auditory temporal order and perceived fusion-nonfusion

Hearing Conservation Program

EVALUATION OF SPEECH PERCEPTION IN PATIENTS WITH SKI SLOPE HEARING LOSS USING ARABIC CONSTANT SPEECH DISCRIMINATION LISTS

But, what about ASSR in AN?? Is it a reliable tool to estimate the auditory thresholds in those category of patients??

11. Hearing Conservation Program Chapter , WAC

Procedure Number 310 TVA Safety Procedure Page 1 of 6 Hearing Conservation Revision 0 January 6, 2003

Research in past years indicates an increased prevalence

PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT

MA 25 Operating Manual

A Comparison of Baseline Hearing Thresholds Between Pilots and Non-Pilots and the Effects of Engine Noise

Hearing Conservation

Musicians With Conventional Noise Notches Have Poorer Extended High Frequency Sensitivity

TO BE RESCINDED Hearing aids. (A) Definitions. (1) "Audiologist."

Anatomy of the Ear. Hearing Screening and Audiometer Tutorial. The speaker has no conflict interest to declare

Hearing Conservation Program

Hearing Evaluation: Diagnostic Approach

3M Center for Hearing Conservation

User Manual. - Pro Edition -

UC Merced Hearing Conservation Program

FACE THE MUSIC: A BEFORE AND AFTER STUDY OF THE HEARING ACUITY OF CLASSICAL MUSIC STUDENTS

AD226 Diagnostic Audiometer

W illeford's early paper (1974) and publications

Aging and Word Recognition in Competing Message

Comparison of Acoustic Immittance Measures Obtained With Different Commercial Instruments

S everal studies indicate that the identification/recognition. Identification Performance by Right- and Lefthanded Listeners on Dichotic CV Materials

W ord recognition performance is poorer. Recognition of One-, Two-, and Three-Pair Dichotic Digits under Free and Directed Recall

What Is the Difference between db HL and db SPL?

PSYCHOMETRIC VALIDATION OF SPEECH PERCEPTION IN NOISE TEST MATERIAL IN ODIA (SPINTO)

SNAP-ON INCORPORATED STANDARD ON HEARING CONSERVATION

CMDS 8120 CLINICAL METHODS in AUDIOLOGY FALL SEMESTER 2013 Tuesday and Thursday, 9:30-10:45 AM Haley Center Room 3110

Environmental Health and Safety. Hearing Conservation Program

Seventh Survey of Audiometric Practices in the United States

Application of a Stimulus Spectral Calibration Routine to Click Evoked Otoacoustic Emissions

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Eliminate the Most Common Challenges in Audiometric Testing A Case for Tablet Audiometry in Occupational Hearing Conservation

S ound is a form of energy generated by vibration. It can be

UCSD HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) and Center for Occupational & Environmental Medicine (COEM) 2017

AMBCO AUDIOMETER

Speech Recognition in Noise for Hearing- Impaired Subjects : Effects of an Adaptive Filter Hearing Aid

Effects of Setting Thresholds for the MED- EL Cochlear Implant System in Children

Intercontinental hearing assessment - a study in tele-audiology

Student Learning Outcome KTS InTASC CEC/CED CAEP ISTE 1. The student will examine the

Test-Retest Reliability of Speech Recognition Threshold Material in Individuals with a Wide Range of Hearing Abilities

Hearing Conservation Program

Temporal order discrimination of tonal sequences by younger and older adults: The role of duration and rate a)

James W. Hall III, Ph.D.

Practical Grading System for Evaluating Cisplatin Ototoxicity in Children

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO :1998

Transcription:

J Am Acad Audiol 11 : 46-51 (2000) The CON-SOT-LOT Test for Nonorganic Hearing Loss Jeffrey S. Martin* Frederick N. Martint Craig A. Champlint Abstract The efficacy of a screening procedure for detecting nonorganic hearing loss using standard audiometric instrumentation was examined. Thirty normal-hearing subjects' responses to continuous and standard and lengthened off-time pulsed tones, using an ascending-descending method, were compared. Subjects were asked to respond to test stimuli in normal-hearing and simulated hearing loss conditions. Data show that there are clinical and statistical differences between subjects' response patterns in the normal-hearing condition as compared to the feigned hearing loss condition. The procedure is offered as a simple method of screening for nonorganic hearing loss. Key Words: Ascending-descending method, nonorganic hearing loss, screening procedure Abbreviations : A-D = ascending-descending, ANOVA = analysis of variance, CON = continuous tone, LOT = lengthened off-time pulsed tone, MML = modified method of limits, NOHL = nonorganic hearing loss, STL = simulated threshold level, SOT = standard off-time pulsed tone ollowing the introduction of the Type V Bekesy pattern by Jerger and Herer in F 1961, which showed more hearing loss for pulsed tones than for continuous tones, modifications of Bekesy audiometry emerged, aiding in the detection of nonorganic hearing loss (NOHL). Hood et al (1964) proposed the Bekesy Ascending Descending Gap Evaluation (BADGE) to examine intensity-change directionality in Bekesy audiograms. Using this procedure, significant gaps (>4 db) between ascending and descending tracings (A-D) were reported to be indicative of NOHL. Hattler (1970) proposed the lengthened off-time (LOT) test based on his previous research (1968), suggesting that changes in duty cycle of the pulsed tones directly affected Type V patterns. This alteration (LOT) increased the number of Type V patterns in patients suspected of NOHL without affecting *Brigham and Woman's Hospital, Division of Audiology, Boston, Massachusetts ; tdepartment of Communication Science and Disorders, The University of Texas at Austin, Austin, Texas Reprint requests : Frederick N. Martin, Department of Communication Sciences and Disorders, Jesse H. Jones Communication Center, The University of Texas at Austin, Austin, TX 78712-1089 the Bekesy tracings of patients with normal hearing or true organic hearing losses. Chaiklin (1990) confirmed Hattler's findings using a descending version of Hattler's LOT test, called DELOT. Although Bekesy audiometry generated plausible screening techniques for detecting NOHL, the limited availability of equipment, test complexity, and test administration time have contributed to its diminished utility during standard hearing evaluations. A recent survey of audiometric practices in the United States showed that only four percent of audiologists used some form of Bekesy audiometry to assess NOHL (Martin et al, 1998a). Similarly, other reliable methods for identifying NOHL, such as auditory evoked potentials, otoacoustic emissions, and acoustic reflex threshold testing, pose limitations as viable screening procedures because of equipment needs and time constraints. These procedures also require changes in either transducer type or patient set-up, which ultimately disrupts the standard test protocol. Due to these limitations, easily performed screening methods using common audiometric equipment have appeal. Harris (1958) evaluated the A-D gap using a modified method of limits (MML) and a basic 46

CON-SOT-LOT/Martin et al clinical audiometer. Results with this technique showed significantly larger gaps between A-D thresholds for patients suspected of NOHL as opposed to those with true hearing losses. A-D gaps of 5 db or more characterized NOHL. Cherry and Ventry (1976), using slightly different separation criteria (A-D gap >10 db) to indicate a suprathreshold response, further validated the MML procedure. Lankford and Meissner (1977) proposed a manual version of the LOT test. In order to simulate LOT pulsed tones, an audiometer with a continuously variable attenuator capable of producing the necessary 20 percent duty cycle was used. Average responses from manual LOT tones exceeding continuous tones by 5.5 db or more suggested NOHL. Results with the manual LOT appear to be a useful modification of Bekesy audiometry in screening for NOHL. A screening approach comparing A-D gaps in NOHL using common audiometric equipment was proposed by Woodford et al in 1997. This method, like the Harris MML procedure (1958), differed from previous investigations in that only responses to continuously presented pulsed tones were compared. A-D differences of 10 db or greater were reported as "unreliable," thereby indicating NOHL. Despite apparent differences in test methodologies, studies using standard audiometric equipment for detecting NOHL lend support for its use as a viable alternative to Bekesy audiometry in this endeavor. The extent to which techniques for identifying NOHL (Type V Bekesy audiogram, A-D gap, and LOT) can be combined into one screening procedure using standard equipment has not been previously investigated and was the focus of the present research. Subjects METHOD Subjects consisted of 30 English-speaking adults (9 males, 21 females), whose ages ranged from 20 to 27 years (mean = 22.3), with normal hearing sensitivity bilaterally. Normal hearing was defined as hearing thresholds lower than or equal to 15 db HL from 250 to 8000 Hz (ANSI, 1996). Although concern has been raised about using normal-hearing subjects for the evaluation of NOHL, many studies have documented this practice (e.g., Cherry and Ventry, 1976 ; Mordaunt and Martin, 1976 ; Woodford et al, 1997 ; Martin et al, 1998b). Furthermore, it can be assumed that patients with true NOHL would be unwilling to volunteer their actual hearing thresholds for experiments like these. Materials and Equipment All audiometric testing was performed in a sound-treated room adhering to ANSI-1991 allowances for permissible ambient noise levels. A Madsen Orbiter 922 clinical audiometer, calibrated to ANSI-1996 specifications, was used for all testing procedures. Acoustic stimuli were presented through Telephonics TDH 39 audiometric headphones mounted in MX-41/AR cushions. Signals Three different acoustic stimuli were used during the procedure. In all cases, the audiometer was set to the "normally on" position : 1. A continuous tone (CON). 2. A pulsed tone with a standard off-time (SOT) (44.4% duty cycle ; 200 msec on, 250 msec off). The slight difference between the duty cycle used here with previous studies using a 50 percent duty cycle was due to audiometer limitations. 3. A pulsed tone with a lengthened off-time (LOT) (22.2% duty cycle ; 200 msec on, 700 msec off). LOT tones were achieved by manually depressing the interrupter switch between successive SOT pulsed tones. Thus, every other pulse was not presented to the subjects. Test Procedure In order to evaluate the sensitivity and specificity of the screening procedure (CON- SOT-LOT) to distinguish between threshold and suprathreshold responses, subjects received test stimuli under two separate hearing conditions. Subjects were initially asked to respond at threshold and then again by simulating a hearing loss. In order to parallel real-world test situations, subjects selected their own levels (in db) for exaggeration of their thresholds. In the normal-hearing task, signals (CON, SOT, and LOT) were monaurally presented at 1000 Hz in random order to each subject in both an ascending and descending method. Test ear was alternated across subjects (15 right, 15 left). The attenuator for all ascending tones was set to -10 db HL, ensuring that the tones were initially presented below threshold. Conversely, 47

Journal of the American Academy of Audiology/Volume 11, Number 1, January 2000 the attenuator was initially set to relatively high intensities (90, 95, and 100 db HL) for presentation of the descending tones. Audiometric thresholds were considered to be the intensity where subjects first indicated that a signal was heard (ascending method) or the intensity where subjects indicated that the signal was no longer present (descending method). The attenuator was manipulated in 5-dB steps until thresholds were established. An attenuation rate of 2.2 db/sec was estimated for SOT tones and 2.4 db/sec for LOT tones. These values correspond to five pulses per intensity increment/decrement for SOT tones and three pulses per intensity increment/decrement for LOT tones. An attenuation rate of 2.5 db/sec for CON tones was easily achieved with practice of the procedure. In the feigned hearing loss condition, the attenuator was randomly set at 10, 20, or 25 db HL for ascending tones, whereas starting intensities for descending tones were presented at 85, 95, or 100 db HL. Alterations in starting level were made to offset any strategies used by subjects, such as counting "jumps" in loudness, or pulse-counting techniques, to arrive at a consistent response level. Besides modifications in starting levels, test protocol remained unchanged. Simulated threshold levels (STLs) were obtained and recorded in the same fashion as for the normal-hearing condition. RESULTS S ubsequent to data collection, a 3 x 2 x 2 analysis of variance (ANOVA) was performed to determine whether significant differences (p <.05) existed between subjects' true thresholds and STLs. In this design, test variables of signal type (CON, SOT, and LOT) and approach mode (ascending and descending) were evaluated with regard to responses obtained across both hearing tasks. Overall results of the ANOVA (Table 1) indicated that subject response patterns in the normal-hearing condition were significantly different from their STLs in the exaggerated hearing loss condition. Moreover, approach mode appeared to largely influence subject responses. Although interaction was noted in the analysis of signal type, due to the fact that all signals were presented in both hearing conditions, a clear assessment of signal type, hearing task, and approach mode within this statistical design may have obscured the differences between them. A main supposition regarding subject responses during threshold measurement was that signal type and approach mode should have minimal effects (<_10-dB range) on true hearing thresholds. In this study, all but seven subjects met this general assumption. Curiously, all seven subjects demonstrated a decrease in hearing sensitivity for continuously presented tones in a descending method (CON D). In order to determine whether these findings occurred as a result of abrupt-onset, high-intensity tones (90-100 db HL), a CON D with a 50 db HL starting intensity (CON D-50) was administered to these seven subjects prior to the acquisition of remaining thresholds. When using CON D-50 signals, thresholds for these seven subjects were within the predicted range. In order to evaluate subject response patterns in each hearing condition independently, two separate 3 x 2 ANOVAs were performed. Results of the ANOVA on true thresholds (Table 2) revealed that signal type and approach mode, when evaluated independently, had no significant effect on hearing thresholds, but a collective comparison of signal and approach did. Although statistically different, this later comparison was still considered to be clinically reliable (<-10-dB range). Results of the ANOVA on subject STLs (Table 3) showed that both approach mode and signal type significantly Table 1 Results of the 3 x 2 x 2 ANOVA Comparing Signal Type and Approach Method of Subject Responses across Both Hearing Conditions Source df Sum of Squares Mean Square F Value p Value Condition 1 229017.78 229017.78 8540.31 0001 Approach 1 6336.61 6336.61 97.91 0001 Condition *approach 1 4271.11 4271.11 66.03.0001 Signal 2 218.75 109.38 0.20.1859 Condition *signal 2 1225.97 612.99 9.48 0001 Approach *signal 2 396.81 198.40 3.07 0478 Approach *signal *condition 2 51.81 25.90 0.40.0670

CON-SOT-LOT/Martin et al Table 2 Results of the 3 x 2 ANOVA Comparing Subject Responses in the Normal-Hearing Condition (with CON D-50 Thresholds) Source of Sum of Squares Mean Square F Value p Value Approach 1 16.81 16.81 1.00 3191 Signal 2 65.83 32.92 1.96 1446 Signal *approach 2 111.94 55.97 3.32 0383 affected subject response patterns when asked to simulate a hearing loss. Subject STLs revealed that, with the exception of three cases, subject responses to ascending signals yielded significantly better thresholds (Fig. 1). Mean A-D gaps for the normal-hearing and exaggerated hearing loss conditions were 0.6 db and 15.3 db, respectively. Tukey post hoc analysis of signal type for STLs showed that LOT tones (mean = 60.25) were significantly different from CON tones (mean = 54.08), but SOT tones (mean = 58.08) were not significantly different from LOT or CON tones. Although the degree of separation between pulsed and continuous tones constituting the Type V pattern may be largely influenced by the A-D technique, STLs for descending SOT and LOT tones in this study did generally indicate poorer hearing than ascending CON tones (Fig. 2). Using a greater than 10-dB range criterion to indicate NOHL, the procedure was found to be 100 percent sensitive and 100 percent specific (with inclusion of CON D-50 thresholds) in the detection of NOHL. DISCUSSION he current investigation was proposed to T assess the efficacy of a procedure requiring only standard audiometric equipment for the evaluation of NOHL. The results obtained in this study show that there are several test paradigms that, when used in concert, can assist in distinguishing between threshold and suprathreshold responses. Based on results with the CON-SOT-LOT procedure, the use of both ascending and descending methods for detecting NOHL is supported. Based upon subject feedback, it appears that the A-D approach inhibits the use of strategies involving memorization of starting intensities for the signals. Difficulty with this task may have been compounded because different starting intensities were also used for each signal presentation. Although subject STLs for LOT and SOT pulsed tones were not statistically different, the exclusion of either one of these tones would have decreased the sensitivity of the procedure below 100 percent. Therefore, the unique combination of manual SOT and LOT tones in this procedure proved to be beneficial. In review of the results obtained in this study, slight elevations in normal-hearing thresholds were found for seven subjects when continuous tones were presented in a descending method (CON D). Therefore, adhering to a greater than 10-dB separation criterion indicating NOHL, inclusion of the CON D thresholds from these seven subjects would reduce the specificity of the procedure to approximately 77 percent. However, slight threshold shifts encountered during the normal-hearing condition would not explain the dramatic response inconsistencies observed for these subjects in the feigned hearing loss condition. Although an exact explanation for this phenomenon is difficult, due to the immediate improvement in subjects'thresholds to CON D tones using a lower starting intensity, auditory fatigue is possible but does Table 3 Results of the 3 x 2 ANOVA Comparing Subject STLs Source of Sum of Squares Mean Square F Value p Value Approach Signal Signal *approach 1 2 2 10503.47 1174.44 87.78 10503.47 587.22 43.89 96.14 5.38 0.40 0001 0054 6698 49

Journal of the American Academy of Audiology/Volume 11, Number 1, January 2000 85 75 4- k- a 65 'Ax 55 45 35 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 Subject L+ Ascending Tones ~Descending Tones I Figure 1 Mean STLs (for CON, SOT, and LOT) for ascending and descending tones. With the exception of three cases (subjects 5, 7, and 11), mean STLs for ascending tones revealed lower reported thresholds than did descending tones. Symbols are connected to demonstrate response patterns from subject to subject. not, in any way, obviate the advantages of this procedure. There are several key components to the administration of the CON-SOT-LOT procedure : (1) the use of all CON, SOT, and LOT tones ; (2) the random presentation of signals in an A-D approach (also randomized); (3) variation in the starting intensities for both ascending and descending tones ; and (4) different attenuation rates for each signal type. A key theme among these components is variation. If one assumes that patients with NOHL attempt to exaggerate hearing thresholds using strategies based upon the "pattern" of the test, then varying the test format would serve to decrease the margin of error in subject classification. Because the procedure can be performed using virtually any audiometer and requires approximately 2 to 3 minutes to complete, its applicability as a screening tool for NOHL is evident. In most cases, the CON-SOT-LOT test can be discontinued when a positive finding for NOHL is observed. Administration of the CON-SOT-LOT test can also be performed in a variety of test environments. For example, the test could be used to screen for NOHL in children during school screenings as soon as this behavior is noted, followed by a repeat screening. Immediate performance of the CON-SOT LOT test might discourage NOHL behavior and possibly eliminate the necessity for more indepth testing. The CON-SOT-LOT test was not designed to produce an exact measurement of hearing status but rather to alert the clinician to the possibility of NOHL. However, some quantitative information can be inferred. In this study, 79 percent of the subjects showed lower STLs for ascending CON tones when compared to other signals. This finding is similar to that reported by Hood et al (1964). Additionally, it is logical to assume that the hearing loss is no greater than the lowest reported response at any frequency. Although the procedure was performed in this study using normal-hearing subjects, very similar results have been obtained on patients who were either fabricating or exaggerating a true hearing loss. In fact, to date, we have seen no patients who were able to defeat this procedure. There is certainly no shortage of objective tests for both identifying and quantifying nonorganic loss. But these tests will not be helpful unless the clinician's index of suspicion leads to the administration of such tests. There continues to be a role for a simple, easily administered screening tool appropriate for the initial stage of auditory evaluation. We suggest that the CON-SOT-LOT test can fill this role. REFERENCES American National Standards Institute. (1996). American National Standard Specifications for Audiometers. (ANSI S3.6-1996). New York : ANSI. 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 Subject [-- -AscendmgTones ~DescendingTones Figure 2 General pattern of poorer hearing for pulsed tones than continuous tones using the CON-SOT-LOT procedure. In all cases, the range of STLs for CON A, SOT D, and LOT D tones exceeded the >10-dB criterion selected to indicate a "reliable" response. Symbols are connected to demonstrate response patterns from subject to subject. American National Standards Institute. (1991). American National Standard Criteria for Permissible Ambient Noise Levels during Audiometric Testing. (ANSI S3.1-1993). New York: ANSI. Chaiklin JB. (1990). A descending LOT-Bekesy screening test for functional hearing loss. J Speech Hear Disord 55 :67-74. Cherry R, Ventry IM. (1976). The ascending-descending gap : a tool for identifying a suprathreshold response. J Aud Res 16 :281-287. 50

CON-SOT-LOT/Martin et al Harris DA. (1958). A rapid and simple technique for the detection of non-organic hearing loss. Arch Otolaryngol 68 :758-760. Hattler KW. (1968). The Type V Bekesy pattern : the effects of loudness memory. J Speech Hear Res 11 :567-575. Hattler KW. (1970). Lengthened off time : a self-recording screening device for nonorganicity. J Speech Hear Disord 35 :113-122. Hood WH, Campbell RA, Hutton CL. (1964). An evaluation of the Bekesy ascending descending gap. J Speech Hear Res 7 :123-132. Jerger J, Herer G. (1961). An unexpected dividend in Bekesy audiometry. J Speech Hear Disord 26 :390-391. Lankford JE, Meissner WA. (1977). The manual lot test. JAm Audiol Soc 2:219-222. Martin FN, Champlin CA, Chambers JA. (1998a). Seventh survey of audiometric practices in the United States. J Am Acad Audiol 9:95-104. Martin FN, Champlin CA, Marchbanks TE (1998b). A varying intensity speech test for simulated hearing loss. Am JAudiol 7:39-44. Mordaunt KM, Martin FN. (1976). Effects of duty cycle on the loudness of pulsed and continuous tones. J Aud Res 16 :171-175. Woodford C, Harris G, Marquette ML, Perry L, Barnhart M. (1997). A screening test for pseudohypacusis. Hear Rev 11(4):23-26.