Aquilion ONE: Pediatric Imaging. Richard Mather, PhD. Senior Manager, CT Clinical Science Toshiba America Medical Systems, Inc.

Similar documents
Debra Pennington, MD Director of Imaging Dell Children s Medical Center

Cardiac CT Techniques in Neonates (and infants)

Managing Radiation Risk in Pediatric CT Imaging

Clinical Image Gallery Next Generation Volume 1


Comanche County Medical Center to Bring World Class Imaging to the Area

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

CT Dose Reduction in Pediatric Patients

Justification, Optimization and Communication in Pediatric CT Imaging: Recent Improvements and Persistent Challenges Designated Emphasis in Nuclear

Translating Protocols Across Patient Size: Babies to Bariatric

Radiation Dose in X-Ray and CT Exams

Lung Perfusion Analysis New Pathways in Lung Imaging. Case Study Brochure PLA 309 Hospital

After the Chest X-Ray:

Combined Anatomical and Functional Imaging with Revolution * CT

IOWA RADIOLOGY 1. Guide to CT Scans Clive Downtown Des Moines

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

X-Ray & CT Physics / Clinical CT

Computed Tomography (CT) - Chest

Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology

Radiation Dose Reduction: Should You Use a Bismuth Breast Shield?

Why is CT Dose of Interest?

7/31/2017. Image Gently is. The Pediatric Radiologist Tailoring CT Protocols to the Patient's Age, Size, and Clinical Scenario.

MRI Assessment of the Right Ventricle and Pulmonary Blood Flow, Perfusion and Ventilation

IMAGE GENTLY HOW CAN YOU HELP?

Pediatric High-Resolution Chest CT

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Radiography/Radiology

To Shield or Not to Shield? Lincoln L. Berland, M.D.

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

CT angiography techniques. Boot camp

Full ultrasound breast volumes. Faster scans. Streamlined workflow. ACUSON S2000 Automated Breast Volume Scanner. Answers for life.

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

created by high-voltage devices Examples include medical and dental x-rays, light, microwaves and nuclear energy

Intravascular Ultrasound

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

The Increasing Use of CT and Its Risks

Pulmonary Embolism. Thoracic radiologist Helena Lauri

Computed Tomography (CT) - Chest

Liver Perfusion Analysis New Frontiers in Dynamic Volume Imaging. Case Study Brochure Chang Gung Memorial Hospital.

Low Dose Era in Cardiac CT

Radiation Dose Reduction Strategies in Coronary CT Angiography

Ultralow Dose Chest CT with MBIR

Utilization of a Patient Dose Tracking and Monitoring System to Modify CT Protocols and Lower Patient Doses

Outline. NCRP Scientific Committee 6-2

When You Need To Know More.

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Liver imaging takes a step forward with Ingenia

Radiation Exposure in Pregnancy. John R. Mayo UNIVERSITY OF BRITISH COLUMBIA

Low-dose and High-resolution Cardiac Imaging with Revolution CT

Process Improvement: High Quality Breast MRI

ViosWorks: A Paradigm Shift in Cardiac MR Imaging

Goals and Objectives MRI (First Year)

CT Chest HRCT CT Chest WO

Certainty. lives in layers. Philips IQon Spectral CT. Computed tomography

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

Volumetric Perfusion CT Using Prototype 256 Detector Row CT Scanner: Preliminary Study with Healthy Porcine Model V

Clinical Applications

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease

Postmortem Computed Tomography Finding of Lungs in Sudden Infant Death.

Rotation: Imaging 2. Nuclear Cardiology (in Imaging 1 and 2)

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

(Non-EKG Gated) CTA Thoracic Aorta = CTA Chest

Low Dose CT Lung Screening: What is Technically Required?

Functional Chest MRI in Children Hyun Woo Goo

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

8/1/2017. Financial Disclosures. Dose Tracking at MGH. How Dose Tracking Affected Protocol Optimization in a Tertiary Quaternary Healthcare Center

Patient preparation and coronary CTA techniques. Gregory Kicska, M.D. Ph.D. University of Washington, Thoracic Imaging

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION

Children's (Pediatric) Ultrasound - Abdomen

Pediatric Lung Ultrasound (PLUS) In Diagnosis of Community Acquired Pneumonia (CAP)

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Imaging Decisions Start Here SM

Ultra-low dose CT of the acute abdomen: Spectrum of imaging findings

Seattle Children s Hospital Radiology Department. Statement regarding radiation exposure related to computed. tomography (CT) exams

ADI Procedure Codes. August 2016 Revised April 2017 Page 1 of 7 ADI Procedure Codes

The radiation dose in retrospective

Overview of Medical Diagnostic and Interventional Imaging: Usage Patterns

CT Radiation Risks and Dose Reduction

Assignable revenue codes: Explanation of services:

What Have We Learned from Children? Donald P. Frush, MD

ACR MRI Accreditation: Medical Physicist Role in the Application Process

Les Outils Cliniques de Demain en Scanner Cardiaque. Cardiaque Status en ECR 2018 From Diagnosis to Prognosis

BENEFITS OF CT AND HOW LEADING ACADEMIC INSTITUTIONS ARE COMMUNICATING RISK TO PATIENTS. James A. Brink, MD Massachusetts General Hospital

Oral Contrast for Abdominal CT: Nay (Or Let s Make CT Great Again )

B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography

Low-Dose CT: Clinical Studies & the Radiologist Perspective

The first MR with IQ. Philips Intera 1.5T With SmartExam

A Randomized Controlled Study to Compare Image Quality between Fenestrated and Non-Fenestrated Intravenous Catheters for Cardiac MDCT

Technology Assessment Institute: Summit on CT Dose Cardiac CT - Optimal Use of Evolving Scanner Technologies

Bottom up cardiac CT for CABG assessment to resolve breathing artefact

BrightSpeed Elite CT with ASiR: Comparing Dose & Image Quality Rule Out Pulmonary Embolism on Initial & Follow-Up Exam

Lung Cancer Screening

9/8/2009 < 1 1,2 3,4 5,6 7,8 9,10 11,12 13,14 15,16 17,18 > 18. Tetralogy of Fallot. Complex Congenital Heart Disease.

CT Dosimetry in the Clinical Environment: Methods and Analysis

Updates on Coronary Angiography Rotational Angiography, 3-D Modeling, and

Fast and easy diagnostic imaging from head to toe

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006

New Horizons in the Imaging of the Lung

Improved image quality of low-dose thoracic CT examinations with a new postprocessing software*

Vascular. Experiences Using an Angiography System with a Inch FPD - CT-Like Imaging of the Neck and Abdomen - 1.

Transcription:

Aquilion ONE: Pediatric Imaging Richard Mather, PhD Senior Manager, CT Clinical Science Toshiba America Medical Systems, Inc.

The use of CT in pediatric diagnostic procedures has increased significantly over the past decade. New advanced applications along with faster scan times and submillimeter, isotropic resolution have made CT a valuable and potentially life saving diagnostic tool. Each year, there are more than 7 million pediatric CT procedures performed in the United States 1. While this means that a great number of children s lives are positively impacted by CT imaging each year, it also means that it is essential to consider the risks associated with medical imaging. For pediatric imaging, the two principle risks are radiation exposure and sedation complications. With 16 cm of craniocaudal coverage in a single axial rotation, Toshiba s Aquilion ONE CT scanner is uniquely suited to minimize both of these risks. UNIQUE IMAGING REQUIREMENTS There are anatomical and physiological differences between children and adults that make pediatric imaging a uniquely challenging endeavor. Anatomical differences such as lower bone density, smaller vessels, and significantly less fat surrounding their organs create different image quality requirements. Dynamic factors such as high heart rates, difficulty holding their breath, and crying during the exam can also make imaging a challenge. For example, since the natural contrast provided by intra-abdominal fat in adults is reduced in pediatric patients, the images generally require more signal to noise compared to adult images. This is somewhat mitigated by the fact that most pediatric patients are smaller and less attenuating than adults, so their images are naturally lower in noise. All these complex factors make it essential that the kv and ma techniques used for pediatric patients are tailored to their unique imaging needs and body sizes. Tailoring the kv and ma is especially important since children are more sensitive to radiation than adults. The BEIR VII report, the main authority on the health risks from low levels of ionizing radiation, shows that the risk from radiation exposure increases rapidly with decreasing age 2. In order to minimize the risks to children, it is critical that the appropriate exposure is used on each individual child. Radiation, however, is not the only risk to a pediatric patient undergoing a CT exam. Because helical CT scans last for several seconds and are sensitive to patient motion, it is often necessary to sedate children to ensure an adequate study and prevent the added radiation of a rescan should the study prove non-diagnostic. While the use of sedation varies from practice to practice, one national survey of sedation use in pediatric imaging reported that over 55% of all pediatric CT exams used some form of light or deep sedation. Furthermore, a more recent study of complications in pediatric sedation found that adverse events occurred in 3.3% of cases and unplanned treatments were necessary in 1.1% of cases 3. Even though the incidence of adverse events is low, the researchers at the Dartmouth Pediatric Sedation Project Site firmly believe that sedation represents an area of pediatric care that exposes patients to the greatest risk of iatrogenic morbidity and mortality 4. In order to minimize the risk to pediatric patients, it is necessary to not only lower the radiation dose but also to minimize the need for sedation. IMAGE GENTLY SM Concerned about awareness of CT radiation dose among both parents and medical professionals, the Alliance for Radiation Safety in Pediatric imaging was formed within the Society of Pediatric Radiology (SPR) in late 2006. This group grew to

2 Aquilion ONE: Pediatric Imaging include radiologists (ACR), technologists (ASRT), and medical physicists (AAPM) and started a campaign known as Image Gently. The purpose of this campaign is to increase awareness about radiation dose in pediatric imaging and to promote best practices for effective dose reduction. The campaign has gained international awareness within the imaging community and among imaging manufacturers. Toshiba and others are working with the Image Gently campaign to continue educational efforts of our applications staff and users as well as to continue optimizing our scanners to produce high quality images at the lowest possible radiation dose. The most effective method of dose reduction for pediatric patients is to limit the scans to only those that are appropriate. The Image Gently campaign urges clinicians to use only single phase scans whenever possible as pre- and post-contrast and delayed scans rarely add additional information in children but can contribute to doubling and tripling the radiation dose 5. Furthermore, it is always important to ensure that the CT scan is the appropriate diagnostic test for the clinical question at hand. Finally, eliminating the need for rescans due to patient motion is critical. To this end, many sites employ sedation to minimize movement during the scan acquisition. Therefore, in order to reduce the overall examination risk to pediatric patients, techniques should be employed to minimize radiation exposure, potential rescans, and sedation. TOSHIBA PEDIATRIC DOSE REDUCTION Toshiba s commitment to patient centered imaging and support of the Image Gently campaign mandate continuous development in technologies that enhance patient safety through radiation dose reduction and avoiding sedation. In order to use the appropriate radiation dose for the appropriate patient, automated software such as SURE Exposure Pediatric measures the size and attenuation of each patient and tailors the radiation dose to achieve the necessary image quality for the task at hand. Using an automatic, A B C Figures 1A, B & C: These images represent the exam of a 2-week-old infant scanned with the Aquilion ONE. With 16 cm of volume coverage, the entire chest and abdomen were covered in a single 0.5 second rotation using just 15 mas and 0.44 msv of dose, and no sedation. The panels show the 3DVR, coronal MinIP, and coronal MIP reconstructions demonstrating diffuse lung infiltration and abdominal distension. Images courtesy of Charité Hospital Humboldt University, Berlin.

Aquilion ONE: Pediatric Imaging 3 individualized protocol maintains a uniform level of image quality for every patient while ensuring that the minimum dose necessary to achieve that quality is used. SURE Exposure Pediatric starts working from the point at which the patient is registered. Monitoring the patient s age during the registration process, the software automatically takes the operator to the Aquilion s optimized suite of pediatric protocols. For each clinical task, there is a separate set of protocols that are tailored to the task s diagnostic needs. For example, a protocol for estimating liver size can handle a significant amount of image noise and would have SURE Exposure settings that reflect that: a high target noise value and a low maximum ma. On the other hand, a protocol set up to characterize a liver lesion requires more radiation dose to ensure a high contrast to noise ratio. Finally, each of these task-oriented protocols is further refined by patient weight with slightly different noise targets and upper and lower ma limits. Protocol tailoring optimizes the radiation dose for patients of every size and automates the protocol guidelines defined by the Image Gently campaign. Toshiba s Aquilion ONE dynamic volume CT scanner goes one step further in pediatric dose reduction. With 16 cm of craniocaudal coverage in a single axial rotation, the Aquilion ONE can scan most infant s and toddler s chests or abdomens in one rotation and no table motion. Since this eliminates the need for helical overlap and over-scanning, it further minimizes the radiation dose for most pediatric cases. In comparing an axial volume acquisition to a helical scan over 16 cm, and equalizing the noise between the two scans, there is a dose savings of 30% when using the volume acquisition. By using volume scanning, when appropriate, the radiation risk to pediatric patients can be minimized with no loss of image quality. TOTAL RISK REDUCTION As described earlier, however, the risk to pediatric patients does not come solely A B Figure 2A & B: 3DVR and coronal high resolution lung views show mild patchy atelectasis in the right lower lobe and along the right major fissure of the right upper lung lobe, the left lung shows consolidation in the lower lobe and a dilatation of the bronchus. Volume scan mode used with one 0.35 second rotation and 0.4 msv of dose, without sedation. Images courtesy of Arkansas Children s Hospital.

4 Aquilion ONE: Pediatric Imaging from radiation exposure. Since many young patients have trouble staying completely still, a clinician has to choose between using sedation and running the risk of a non-diagnostic exam. With 16 cm volume scanning on the Aquilion ONE, sedation can be greatly reduced or possibly eliminated since an entire acquisition can be accomplished more than 10 times faster than helical, in as little as 0.35 seconds, and motion during the scan can be eliminated. Figure 3 shows the chest CTA of a 2-year-old patient with a congenital pulmonary sling. Even though this patient was breathing and crying during the examination, the scan was completed without sedation using a single 0.35 second volume rotation. With the rapid, whole volume acquisition of the Aquilion ONE, this study has no motion artifact and was completed with a minimal risk to the patient. Another inherent risk in using sedation with imaging procedures is that the sedation itself can alter the physiologic condition that is being examined. Sedation can cause relaxation of the airway in patients with tracheomalacia causing airway collapse. Once airway collapse occurs, extubation will be difficult. Additionally, in some cases, the use of sedation can be acutely dangerous to the patient. For example, patients with Williams Syndrome have been reported to undergo coronary artery collapse following anesthesia with a high risk of death. The ability to image these patients in one rapid rotation during free breathing can greatly minimize the overall examination risk. Therefore, the reduction or elimination of anesthesia from a pediatric exam not only streamlines the scanning process but, more importantly, reduces the major contributor of acute risk to the patient. Furthermore, since volume scanning can be completed so quickly, sometimes during free breathing, the likelihood of needing a rescan, and extra radiation exposure, due to patient motion is drastically reduced. Finally, with the significant dose reduction possible on the Aquilion ONE, the overall A B Figure 3: This image shows the 3D VR of a 2-year-old patient with a congenital pulmonary artery sling. The CT angiogram of the pulmonary artery was performed using just 7cc of iodinated contrast. The scan was acquired using a single 0.35 second rotation while the baby was breathing and crying. The total radiation dose of this exam was 0.4 msv. Image courtesy of University Of Florida Shands. Figures 4A & B: The internal auditory canals of this 2-year-old patient were scanned for hearing loss. This high resolution scan was completed with a single 0.5 second volume acquisition and 0.22 msv of dose and no sedation. From this scan, it was concluded that the patient has bilateral tympanic membrane thickening contributing to the hearing loss. Also, note the detail of the semi-circular canals. Images courtesy of Arkansas Children s Hospital.

Aquilion ONE: Pediatric Imaging 5 acute and long term risk to the patient from the CT exam is minimized. INITIAL EXPERIENCE AT ARKANSAS CHILDREN S Arkansas Children s Hospital (ACH) runs a busy pediatric CT service scanning over 30 patients per day. Long time advocates of radiation dose and sedation reduction in pediatric CT, ACH has kept on the cutting edge of CT technology. Continuing with this dedication to patient safety, ACH recently installed an Aquilion ONE in their Radiology department. Using the Aquilion ONE, ACH has scanned a wide variety of patients from sinus exams in a single rotation using 0.1 msv of radiation dose to acquiring a whole 16 cm lung and chest in 0.35 seconds. Due to the rapid, volumetric imaging ability of the Aquilion ONE, their use of sedation has been significantly reduced for nearly all of their patients. CONCLUSIONS With advancing technology, the clinical utility of CT has increased significantly over recent years. This has led to a tremendous increase in the number of pediatric procedures and, therefore, in the total radiation exposure to the pediatric population. Furthermore, there is a distinct acute risk to pediatric patients from the use of sedation to ensure motion free studies using helical acquisitions. At cutting edge institutions around the world, the Aquilion ONE has proven its ability to dramatically reduce radiation dose and the use of sedation in pediatric patients. With its commitment to patient focused imaging, Toshiba has continuously developed technology to minimize patient risk. Figure 5: 3-year-old child with hydrocephalus and who has a ventricular shunt, showing signs of mental status changes likely due to increased intra cranial pressure. Patient is scanned using volume scan mode and 0.16 msv of dose and no sedation to check placement and position of the right parietal shunt catheter. Image courtesy of Arkansas Children s Hospital. Figure 6: 8-year-old boy was diagnosed with lymphangioma and as part of follow up after his right parotid gland resection, an Aquilion ONE CT angiography was performed. Volume was scanned using a single 0.5 second rotation and 0.3 msv of radiation dose without sedation. Without evidence of a recurrent or residual lesion, some small residual right parotid gland tissue is still present. Image courtesy of Arkansas Children s Hospital.

www.medical.toshiba.com REFERENCES 1. Mettler FA, Wiest PW, Locken JA et al. 2000, CT scanning: patterns of use and dose. J Radiol Prot. 20:353-359. 2. Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation; Nuclear and Radiation Studies Board, Division on Earth and Life Studies, National Research Council of the National Academies. Health Risks From Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2. Washington, DC: The National Academies Press; 2006. 3. Cravero JP, Blike GT, Beach M, Gallagher SM, Hertzog JH, Havidich JE, Gelman B; Pediatric Sedation Research Consortium. 2006, Incidence and nature of adverse events during pediatric sedation/anesthesia for procedures outside the operating room: report from the Pediatric Sedation Research Consortium. Pediatrics: 118(3):1087-96. 4. Dartmouth Pediatric Sedation Project Site. http://an.hitchcock.org/pedisedation. Accessed Jan 23, 2009. 5. The Alliance for Radiation Safety in Pediatric Imaging. Image Gently site. http:// www.pedrad.org/associations/5364/ig. Accessed Jan 23, 2009. 2441 Michelle Drive, Tustin CA 92780 / 800.421.1968 Toshiba Corporation 2009. All rights reserved. CTWP1069US