Indiana University Health Proton Therapy Center. Chee-Wai Cheng, Ph.D.

Similar documents
Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Quality assurance in external radiotherapy

Learning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan

EORTC Member Facility Questionnaire

Computed tomography Acceptance testing and dose measurements

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

Amendment No. 2. Item No. 2 (Rfx/ Event number )

A new geometric and mechanical verification device for medical LINACs

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Treatment Efficiency and Optimization of Patient Care with IBA ProteusOne

such as lung cancer or breast cancer

Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines for Gamma Knife Radiosurgery. A guidance document on behalf of:

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

Work partially supported by VisionRT

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

Eric E. Klein, Ph.D. Chair of TG-142

ph fax

The Journey of Cyberknife Commissioning

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

IBA Dosimetry Company Presentation. Patient Safety & Quality Control

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Limits of Precision and Accuracy of Radiation Delivery Systems

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

Unrivaled, End-to-End

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

RPC s Credentialing Programs for Clinical Trials

Presented by: Rebecca M. Howell PhD, DABR, FAAPM. Results from Voluntary Independent External Peer Review of Beam Output

IMRT QA: Point Dose Measurements or 2D Array?

Two Week Course Curriculum Catalog

Hampton University Proton Therapy Institute

Proton Stereotactic Radiotherapy: Clinical Overview. Brian Winey, Ph.D. Physicist, MGH Assistant Professor, HMS

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Leila E. A. Nichol Royal Surrey County Hospital

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry J. Phys.: Conf. Ser.

TEMPLATE PORTFOLIO FOR THE REGIONAL CLINICAL TRAINING PROGRAMME IN RADIOTHERAPY MEDICAL PHYSICS

Volumetric Modulated Arc Therapy - Patient Specific QA

Proton Therapy Dosimetry & Clinical Implementation. Baldev Patyal, Ph.D., Chief Medical Physicist Department of Radiation Medicine

Two Week Course Curriculum October 8-20, 2018

Dental ConeBeam Computed Tomography (CBCT) X-ray Systems

Application(s) of Alanine

Efficient Dosimetry for Proton Therapy

Planning for the Installation of a Compact Superconducting Proton Therapy Unit in a Busy Medical Center Environment

Quality Assurance in Radiation Therapy

Dose perturbation effect of metallic spinal implants in proton beam therapy

Assessment of Dosimetric Functions of An Equinox 100 Telecobalt Machine

Nuclear Associates

Dental Extraoral X-ray Systems

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

Learning objective. Outline. Acknowledgements. KV CBCT Imaging Part I. R Hammoud AAPM 2008 CE-Therapy (SAM) 1

Inter-fractional Positioning Study for Breast Cancer with Proton Therapy using a 3D Surface Imaging System

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

Peak temperature ratio of TLD glow curves to investigate the spatial variation of LET in a clinical proton beam

Practical Challenges and Opportunities for Proton Beam Therapy. M. F. Moyers Loma Linda University Medical Center

Debate Motion. Theoretical benefits of VMAT: Real Costs of VMAT. "Arc Based Techniques Will Make Conventional IMRT Obsolete

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

X-Ray Guided Robotic Radiosurgery for Solid Tumors

A model for assessing VMAT pre-treatment verification systems and VMAT optimization algorithms

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Treatment Planning (Protons vs. Photons)

CT Quality Control Manual FAQs

Dosisverifikation mit Delta 4 Discover während der Behandlung

Small field diode dosimetry

Sasa Mutic a) Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110

Fetal Dose Calculations and Impact on Patient Care

Intensity Modulated RadioTherapy

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

Proton Beam Therapy at Mayo Clinic

Diversity in Medical Applications: The Linac Example

SRS Uncertainty: Linac and CyberKnife Uncertainties

IMRT Implementation And Patient Specific Dose Verification With Film And Ion Chamber Array Detectors

GATE MONTE CARLO DOSIMETRY SIMULATION OF MARS SPECTRAL CT

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

MRI to fit your planning. Philips Panorama HFO Oncology Configuration

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

Herlev radiation oncology team explains what MRI can bring

IORT with mobile linacs: the Italian experience

Assessment of a three-dimensional (3D) water scanning system for beam commissioning and measurements on a helical tomotherapy unit

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

Verification of Advanced Radiotherapy Techniques

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Online Care, Online Control, Online Confidence

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

Dental Intraoral X-ray Systems

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

PRESCRIBING RECORDING AND REPORTING PROTON BEAM THERAPY ICRU 78. RAJESH THIYAGARAJAN Senior Medical Physicist & RSO Medanta The Medicity

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

BICOE Breast Imaging Center of Excellence. What is it? - Requirements. National Mammography Database. What do you get? ACR Accreditation in:

Mammography. Background and Perspective. Mammography Evolution. Background and Perspective. T.R. Nelson, Ph.D. x41433

Assessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital

An anthropomorphic head phantom with a BANG polymer gel insert for dosimetric evaluation of IMRT treatment delivery

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

Transcription:

Indiana University Health Proton Therapy Center Chee-Wai Cheng, Ph.D.

Machine configuration and layout Fixed beam line, double scattering and propeller

Uniform scanning nozzle and snout Gantry room Range modulator

Indiana University Health Proton Therapy Center 3 snout sizes (10cm, 20cm and 30cm) 30-40 patients treated per day Typical patient mix (present time): prostate (30%), H&N (30%), Peds+brain (40%)

Indiana University Health Proton Therapy Center Current Clinical Staffing 6 physicists and 2 medical physics assistants 8 therapists and 3 therapist assistants 3 dosimetrists 5 radiation oncologists (4 treat patients between the PTC and the IU Cancer Center).

Daily Machine QA MPA/Physicist performs the QA: Alignment Lasers, snout, x-rays and DR panels, gantry, light-field Safety X ray systems, barcode scanner, intercom, cameras, panic button, patient positioner, floor panels, interlocks Beam Output constancy, flatness and symmetry, radiation survey (Friday only) Typically takes 30 minutes per room Therapist check room readiness Patient positioner, gantry, snout, DDS, BDS

Daily QA

Monthly QA (gantry room) Output factor for the reference condition in water phantom with calibrated IC and Elect. Range and SOBP (2.8, 10, 14.5cm) for 10cm fieldsize for three energy ranges: low, medium and high using a MLIC Symmetry and flatness at the middle of 10cm SOBP for the 3 snout sizes (10, 20 and 30cm) and the three energy ranges (low, medium and high) with MatrixX Typically takes 4-5 hours per room

SOBP measurement with MLIC 100 80 60 40 DD Prox Bound Dist Bound 20 0 8 10 12 14 16 18 20 22 24

Annual QA Additional QA (not performed in monthly): Gantry isocentricity with star-shot Linearity of OF-MU, OF-Cvolt, OF constancy-dose rate, OF vs gantry angle All three snout alignment at full extension/retraction Snout position check at 270 o and 90 o at full extension/retraction for all three snouts. X-ray source tests: kvp calibration, exposure reproducibility, timer accuracy, mas linearity, HVL Dosimetry protocol: TRS398 ADCL calibrated Advanced Markus chamber and electrometer.

Mechanical Isocenter Check with pointer and x-rays Light and Rad coincidence Star shot

Patient Support System Treatment Table & Robotic systems QA Degree of freedom: (x, y, z), Pitch, roll, Yaw Motion accuracy Reproducibility Adoptability Compatibility Safety

Dose monitor linearity Electrometer Charge (nc) 12.0 11.0 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 TR3 Ion Chamber Charge vs. DDS Requested MU (Constant Dose Rate) Markus A12/10 Linear (Markus) Linear (A12/10) y = 0.0193x + 0.001 R 2 = 1 y = 0.0067x - 0.0401 R 2 = 0.9992 0 100 200 300 400 500 600 700 DDS requested MU

OF variation with gantry angle 1.02 TR2 TR3 1.01 1.00 0.99 0.98 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 Gantry Angle Dose Variation

Patient Specific QA Relative output factor measurements in water phantom of aperture and compensator for each field For field size<3cm diameter, measurements taken at different points along SOBP to locate appropriate point of measurement (MLIC was used before). QA tolerances Relative output factor ±2% for both open (aperture only) and closed (with compensator) Re-measure to confirm discrepancy Move IC along SOBP to examine change in OF to understand the discrepancy

Unique Implementations at IUHPTC Quarterly QA Absolute cross-calibration of all IC available (4) Laser alignment Robot alignment, constancy 10cm snout alignment at full retraction/extension w/ x rays and four cardinal gantry angles X ray and DR panel alignment using x rays Light and radiation coincidence Emergency stop and emergency power in wall outlet

Top 3 items in our wish list (if we could have them in the future) Commercial Imaging system for Image Guidance (eg., MedCom, kvct, In-room CT) Spot scanning Record-and-verify system

Acknowledgement Chris Allgower Mark Wolanski Li Zhao Leia Fanelli Archana Gautam Len Coutinho Brian Allen Ryan Reed Indra Das Laddie Derenchuk IUCO Engineering staff IUCO software engineers http://www.google.com/search?q=analemma&rls=com.microsoft:en-us:ie- SearchBox&tbm=isch&tbo=u&source=univ&sa=X&ei=XwT8UeSgBYycrQHPi4C ocw&ved=0ceiqsaq&biw=888&bih=820