Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and Julian Garcia-Sanchez METHODS

Similar documents
INTRODUCTION S. HERDENER, D. HAFIZOVIC, M. PACHE, S. LAUTEBACH, J. FUNK. University Eye Hospital, Freiburg - Germany

Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry

Dina H. Erickson, O.D., a Denise Goodwin, O.D., a Michael Rollins, O.D., b Amber Belaustegui, O.D., c and Chad Anderson a

CLINICAL SCIENCES. Effect of Central Corneal Thickness, Corneal Curvature, and Axial Length on Applanation Tonometry

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer

An Ultra-High-Speed Scheimpflug Camera for Evaluation of Corneal Deformation Response and Its Impact on IOP Measurement

CLINICAL SCIENCES. Comparison of Ocular Response Analyzer Parameters in Chinese Subjects With Primary Angle-Closure and Primary Open-Angle Glaucoma

MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

CLINICAL SCIENCES. Clinical Significance of Central Corneal Thickness in the Management of Glaucoma

Evaluation of the Effect of Diabetes Mellitus on Corneal Biomechanics

True IOP No Doubt Facts and Figures Figures. Ziemer Ophthalmic Systems AG a Ziemer Group Company Allmendstrasse 11 CH-2562 Port, Switzerland

Role of central corneal thickness measurement in management of open angle glaucoma and glaucoma suspects in Calabar, Nigeria

Policy #: 354 Latest Review Date: July 2011

1 Birmingham and Midland Eye Centre, City Hospital, Birmingham, 2 Ophthalmic Research Group, Life and Health Sciences, Aston

Comparison of Intraocular Pressure Measurements by the Ocular Response Analyzer and Goldmann Applanation Tonometer after Penetrating Keratoplasty

December 2016, Volume: 8, Issue: 12, Pages: , DOI:

Peretyagin O.A., Cand. Med. Sc., Ass. Prof.; Dmitriev S.K., Dr. Med. Sc., Prof.; Lazar Yu.M., Cand. Med. Sc.; Tatarina Yu.A., Junior Research Fellow

Intraocular pressure changes and relationship. Corneal Biomechanics After SMILE and FS-LASIK

Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression.

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma

Deep anterior lamellar keratoplasty (DALK) is considered

Effects of Intracorneal Ring Segment on Corneal Biomechanics in Keratoconic Eyes. Abstract

Clinical Study Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure

NIIOS. Cornea Specialist, Melles Cornea Clinic, NIIOS, Rotterdam, the Netherlands Naval Hospital, Athens, Greece VASILIS S.

The Association of Central corneal thickness with Intra-ocular Pressure and Refractive Error in a Nigerian Population

Laser in situ keratomileusis (LASIK) has

Correlating central corneal thickness and intraocular pressure in ocular hypertension and glaucoma

Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India

Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery

Central corneal thickness among glaucoma patients attending Menelik II Hospital, Addis Ababa, Ethiopia

Recent concerns regarding the depth of tissue ablation with

Central corneal thickness and vascular risk factors in normal tension glaucoma

Comparing Corneal Variables in Healthy Subjects and Patients with Primary Open-Angle Glaucoma

Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes

Kobe University Repository : Kernel

Correspondence should be addressed to Fusako Fujimura;

International Journal of Health Sciences and Research ISSN:

The Ocular Response Analyzer (ORA; Reichert Ophthalmic

Ocular hypertension is present in approximately 8%

Analysis of differences in intraocular pressure evaluation performed with contact and non-contact devices

Correlation between presence of primary irisand cilliary body cysts and intraocular pressure

The changes in corneal biomechanical parameters after phototherapeutic keratectomy in eyes with granular corneal dystrophy

Original Article Effects of topical travoprost 0.004% on intraocular pressure and corneal biomechanical properties in an animal model

Ocular Rigidity Evaluation After Photorefractive Keratectomy: An Experimental Study

Central corneal thickness determined with optical coherence tomography in various types of glaucoma

Vision Research & Clinical Trials Havener Eye Institute Jenna Rajczyk Demarcus Williams 13 April 2018

INTRODUCTION MIKLOS SCHNEIDER 1, GABOR BORGULYA 2, ANDRAS SERES 1, ZOLTAN Z. NAGY 1, JANOS NEMETH 1

Glaucoma is the leading cause of irreversible blindness in

The Egyptian Journal of Hospital Medicine (October 2018) Vol. 73 (9), Page

Central Corneal Thickness and its Association with Ocular Parameters

Intraocular pressure (IOP) is of fundamental importance in

Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors

A Case of Primary Congenital Glaucoma

Recent evidence has stressed the clinical role of the assessment

Goldmann Tonometer Prism with an Optimized Error Correcting Applanation Surface

Comparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy

Glaucoma. Glaucoma. Optic Disc Cupping

Post-LASIK Ectasia associated with Pigmentary Glaucoma: Tomographic and Biomechanical Characterization

Goldmann applanation tonometry compared with corneal-compensated intraocular pressure in the evaluation of primary open-angle Glaucoma

NON-INVASIVE OCULAR RIGIDITY MEASUREMENT: A DIFFERENTIAL TONOMETRY APPROACH

Self-monitoring of disease has long been of proven value. For

Corneal Hysteresis, Resistance Factor, Topography, and Pachymetry After Corneal Lamellar Flap

The Heritability of Corneal Hysteresis and Ocular Pulse Amplitude: A Twin Study

Targeting Intraocular Pressure in Glaucoma: a Teaching Case Report 1

Changes in Central Corneal Thickness over Time

Refractive corneal surgery (RCS) using a laser, such as. Glaucoma Progression in Eyes with a History of Refractive Corneal Surgery.

Comparison of Central Corneal Thickness Measurement with Pentacam and Ultrasound

The Egyptian Journal of Hospital Medicine (January 2018) Vol. 70 (8), Page

pat hways Medtech innovation briefing Published: 15 March 2016 nice.org.uk/guidance/mib57

Diabetes, Hyperglycemia, and Central Corneal Thickness

Pearls for the Refractive Technician Fadiah Alkhawaldeh, IMBA, COT, ROUB

Effect of brimonidine on intraocular pressure in normal tension glaucoma: A short term clinical trial

Corneal hysteresis in patients with glaucoma-like optic discs, ocular hypertension and glaucoma

Circadian variations in central corneal thickness and intraocular pressure in patients with glaucoma

Based on the studies by Goldmann and Schmidt 1 and Ehlers. Central Corneal Thickness Correlated with Glaucoma Damage and Rate of Progression

The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology

Central corneal thickness (CCT) measurement is a critical

Reports. Macular Thickness as a Potential Biomarker of Mild Alzheimer s Disease

Intro to Glaucoma/2006

Is NTG different from POAG?

Central and Peripheral Changes in Anterior Corneal Topography after Orthokeratology and Laser in situ Keratomileusis

Clinical Study Short-Term Effect of Standard Automated Perimetry Testing on Intraocular Pressure in Patients with Open-Angle Glaucoma

MEASURING THE SIZE OF A TREATMENT EFFECT: RELATIVE RISK REDUCTION, ABSOLUTE RISK REDUCTION, AND NUMBER NEEDED TO TREAT

Trabeculectomy is an effective method for lowering

Landmark Tube Trials

Effects of laser in situ keratomileusis (LASIK) on corneal biomechanical measurements with the Corvis ST tonometer

Correspondence should be addressed to Pedro Arriola-Villalobos; pedro

Central corneal thickness and normal tension glaucoma: A cross-sectional study

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

Dr Taha Abdel Monein Labib Professor of Eye Surgery Cairo University.

Comparison of Corneal and Anterior Chamber Parameters following Myopic laser in situ keratomileusis and photorefractive keratectomy by

Laser in situ keratomileusis (LASIK) has proven to be

Interest in central corneal thickness (CCT) and glaucoma was. Central Corneal Thickness and Glaucoma in East Asian People.

Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

펨토초레이저와미세각막절삭기를이용한근시교정수술에서임상성적비교

THE TAMILNADU DR.M.G.R. MEDICAL UNIVERSITY CHENNAI, TAMILNADU

Elevated intraocular pressure (IOP) is the most important. The Effect of Trabeculectomy on Ocular Pulse Amplitude. Glaucoma

Transcription:

Ocular Response Analyzer versus Goldmann Applanation Tonometry for Intraocular Pressure Measurements Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and Julian Garcia-Sanchez PURPOSE. To establish correlations between intraocular pressure (IOP) measurements obtained with the ocular response analyzer (ORA) and the Goldmann applanation tonometer (GAT). The effects of central corneal thickness on the measures obtained were also examined. METHODS. This was a cross-sectional study. IOP was determined in 48 eyes of 48 patients with glaucoma In all patients, central corneal thickness (CCT) was measured by ultrasound pachymetry. RESULTS. ORA readings were consistently higher than GAT measurements (Goldmann-correlated IOP IOP GAT mean difference, 7.2 3.5 mm Hg; corneal-compensated IOP IOP GAT mean difference, 8.3 4.0 mm Hg) However, differences were not constant and increased with increasing IOP GAT readings, both with respect to Goldmann-correlated IOP (slope 0.623, P 0.0001) and corneal-compensated IOP (slope 0.538, P 0.0001). Both pressure measurements provided by the ORA showed significant correlation with CCT (CCT versus Goldmann-correlated IOP: r 0.460, P 0.001; CCT versus corneal-compensated IOP: r 0.442, P 0.001). No significant effects of corneal curvature or refraction on any of the pressures were observed. CONCLUSIONS. The ORA significantly overestimates IOP compared with the GAT. Differences between both sets of measures increase as the GAT-determined IOP increases. ORA readings seem to be affected by central corneal thickness. (Invest Ophthalmol Vis Sci. 2006;47:4410 4414) DOI:10.1167/ iovs.06-0158 It has been widely documented that Goldmann applanation tonometry (GAT) measures can be affected by several ocular properties such as corneal curvature, axial length, and central corneal thickness. 1 5 Recent studies focusing on the treatment of ocular hypertension 6,7 have reconfirmed the importance of corneal thickness on pressure measurements. From the Hospital Clínico San Carlos, and Instituto de Investigaciones Oftalmologicas Ramon Castroviejo, Universidad Complutense, Madrid, Spain Supported in part by the Instituto de Salud Carlos III, Proyecto C03/13: Investigación clinica y basica para la prevención de la ceguera. LEP SA (Barcelona, Spain) provided the Ocular Response Analyzer for an unrestricted trial period. Submitted for publication February 11, 2006; revised May 7 and June 12, 2006; accepted August 8, 2006. Disclosure: J.M. Martinez-de-la-Casa, None; J. Garcia-Feijoo, None; A. Fernandez-Vidal, None; C. Mendez-Hernandez, None; J. Garcia-Sanchez, LEP SA (F) The publication costs of this article were defrayed in part by page charge payment. This article must therefore be marked advertisement in accordance with 18 U.S.C. 1734 solely to indicate this fact. Corresponding author: Julian Garcia-Feijoo, Departamento de Glaucoma, Hospital Clinico San Carlos, Martin Lagos sn, 28040 Madrid, Spain; mherrerad@sego.es. These findings have prompted the development of numerous formulas and nomograms designed to compensate for the corneal thickness effect on GAT, but none of these methods has been entirely satisfactory. 8,9 Similarly, as a result of efforts to mitigate some of the limitations of conventional tonometry, several new tonometers have appeared on the scene. One such recently marketed instrument, the Ocular Response Analyzer (ORA; Reichert Inc., Depew, NY), is able to establish the biomechanical properties of the cornea and use this information to adjust IOP measurements according to these properties. The ORA provides four variables: the Goldmann-correlated IOP, corneal-compensated IOP, corneal resistance factor, and corneal hysteresis. A precisely metered collimated air pulse causes the cornea to move inward, past applanation, and into a slight concavity. Milliseconds after applanation, the air pump shuts off, and the cornea gradually recovers its normal configuration, passing through a second applanation state. An electro-optical system monitors the deformation of the cornea throughout the entire process, and two independent values are obtained for the inward and outward applanation events. Because of energy absorption, or damping, in the cornea, the inward and outward applanation events are delayed, resulting in two different pressures. The average of these two pressures provides a reproducible Goldmann-correlated IOP, and the difference between the two pressures is called corneal hysteresis. 10 Corneal hysteresis is an indication of viscous damping in the cornea, reflecting the capacity of corneal tissue to absorb and dissipate energy. Previous studies have revealed that this measure ascribed to corneal tissue is independent of the radius of curvature of the cornea, corneal astigmatism, visual acuity, or axial length. 11 Corneal-compensated IOP is a pressure measurement that utilizes the new information provided by the corneal hysteresis measurement to provide an IOP that is less affected by corneal properties. 11 The Corneal Resistance Factor, also derived from corneal hysteresis, is an indicator of the overall resistance of the cornea, which, according to previous data, seems to be related to central corneal thickness and GAT-determined IOP but not to corneal-compensated IOP. The purpose of the present study was to examine using the ORA the biomechanical properties of the cornea in a group of patients with primary open-angle glaucoma and to correlate the IOP measurements provided with those obtained via conventional applanation tonometry. METHODS Patients with a diagnosis of glaucoma were recruited from the Glaucoma Department of the Hospital Clínico San Carlos, Madrid. The study was discussed in detail with each patient, and informed consent was obtained from all participants in accordance with the tenets of the Declaration of Helsinki. The need for formal approval was waived by Investigative Ophthalmology & Visual Science, October 2006, Vol. 47, No. 10 4410 Copyright Association for Research in Vision and Ophthalmology

IOVS, October 2006, Vol. 47, No. 10 Ocular Response Analyzer versus Goldmann Applanation Tonometer 4411 TABLE 1. Baseline Characteristics of the Study Population Age, y (mean SD) 65.1 14.5 Gender (M/F) 22/26 Visual acuity (mean SD) 0.9 0.1 Visual field mean deviation, db (mean SD) 7.3 4.1 Cup-disc ratio (mean SD) 0.5 0.2 Glaucoma medication* Prostaglandin analogues 32 -Blockers 18 2-Adrenergic agonists 5 Topical CAIs 3 * 38/48 (79.2%) eyes were under treatment with one drug, and 10/48 (20.8%) eyes received combined therapy (two drugs). our Institutional Review Board. For inclusion, the patients were required to have had a diagnosis of glaucoma in any of its forms and to show reproducible visual field defects. We excluded patients with refractive defects greater than 6Dofspherical equivalent and/or more than 5 D of astigmatism, and a best corrected visual acuity less than 20/25. Patients with any type of corneal disease, or those having undergone any type of eye surgery were also excluded. Only one eye, fulfilling all the inclusion criteria and none of the exclusion criteria, was designated as the study eye. When this was true of both eyes of a patient, the study eye was chosen at random. In all patients, central corneal thickness was determined by ultrasound pachymetry (Dicon P55; Paradigm Medical Industries Inc., UT). IOP was then determined using the ORA and the GAT (Haag-Streit, Köniz, Switzerland). Each patient also underwent an examination to establish his or her refractive error (sphere, cylinder, and spherical equivalent) and corneal curvature (mean K). Patients were randomly divided into two groups to vary the order in which the tonometers were applied using a randomization list obtained from www.randomization.com. All measurements were made by two examiners, one using each tonometer, who were masked to the results obtained with the other tonometer. The ORA was used to obtain four measurements in each patient, and the mean of these four readings was used in the analysis according to the manufacturer s instructions. The GAT readings used were two IOP measurements per person, or three measurements if the difference between the first two IOPs was greater then 2 mm Hg. Mean IOP was used in the analysis. All statistical tests were performed on computer (SPSS 12.0 software for Windows; SPSS Inc., Chicago, IL). The Kolmogorov-Smirnov test was used to check for a normal distribution of quantitative data, which are provided as the mean and SD. Differences between the measurements obtained using the two instruments were evaluated using the Student s paired t-test, whereas intermethod reliability was established by calculating intraclass correlation coefficients (r). A Bland-Altman plot 12 of the difference between the ORA and GAT readings against the average of the two was drawn to assess agreement between the two methods and the presence of systemic bias. The level of significance for each contrast was set at P 0.05. The effect of multiple comparisons was corrected by the a posteriori Bonferroni test. RESULTS The series examined comprised 48 eyes of 48 patients with primary open-angle glaucoma of mean age 65.1 14.5 years. Table 1 shows the characteristics of the study population. Refractive error, corneal curvature, and central corneal thickness recorded for each patient are provided in Table 2. The mean IOP obtained using the GAT was 16.8 3.4 mm Hg (range, 10 25 mm Hg), whereas those provided by the ORA were 24.1 5.2 mm Hg (range, 14 40 mm Hg) for Goldmann-correlated IOP (P 0.0001) and 25.1 5.4 mm Hg (range, 13 41 mm Hg) for corneal-compensated IOP (P 0.0001). The Bland-Altman plots in Figures 1 and 2 show the differences in pressure measurements obtained with ORA and GAT. These differences were not constant across the pressure range examined, but increased as the pressure values determined using the GAT increased (Goldmann-correlated IOP versus IOP GAT: slope 0.623, P 0.0001; corneal-compensated IOP versus IOP GAT: slope 0.538, P 0.0001). Only in 4.2% of the eyes (two eyes) was the difference between Goldmanncorrelated IOP and IOP GAT less than 2 mm Hg, whereas differences between corneal-compensated IOP and IOP GAT under 2 mm Hg were recorded in 6.2% of eyes (three eyes). Significant correlation was also detected between the two pressure measurements provided by the ORA (Goldmann-correlated IOP versus corneal-compensated IOP: r 0.909, P 0.0001; Fig. 3). The mean difference between these two pressures was 1.0 2.3 mm Hg. Mean corneal hysteresis and corneal resistance factor were 8.8 2.1 (range, 3.9 14.7) and 11.5 2.1 (range, 5.7 18.5), respectively. These variables correlated significantly (r 0.698, P 0.0001). Corneal hysteresis showed correlation with corneal-compensated IOP (r 0.573, P 0.0001), whereas the corneal resistance factor correlated with IOP GAT (r 0.437, P 0.001) and with central corneal thickness (r 0.503, P 0.0001). When we analyzed the effects of corneal thickness on the measures provided by the ORA, both the Goldmann-correlated IOP and corneal-compensated IOP showed weak yet significant correlation with central corneal thickness: central corneal thickness versus Goldmann-correlated IOP: r 0.460, P 0.001; central corneal thickness versus corneal-compensated IOP: r 0.442, P 0.001. The IOPs obtained with the GAT showed no significant correlation with central corneal thickness (r 0.263, P 0.07). None of the pressure measurements was significantly affected by refraction or corneal curvature. No complications arising from the use of either tonometer was recorded. DISCUSSION To date, no factor used to correct for central corneal thickness in intraocular pressure measurements has been completely satisfactory. 13 Many of these correction factors are based on the changes in corneal thickness and IOP observed after refractive surgery. Besides corneal thinning leading to reduced IOP determined by applanation tonometry, surgery has other effects on corneal architecture (rigidity, deformability changes) that are not accounted for by correction factors. This is probably why these factors cannot be applied to IOP determinations in patients with glaucoma. Over the past few years, several new instruments have been tried in an effort to resolve the limitations of conventional tonometry. Recent studies performed using the new dynamic contour tonometer (DCT) seem to indicate less dependence on TABLE 2. CCT, Refractive Error, and Corneal Curvature in this Series of 48 Eyes of 48 Patients with Glaucoma Minimum Maximum Mean SD CCT ( m) 475.0 640.0 555.3 41.2 Mean K 39.4 48.2 43.7 1.8 Sphere (D) 5.2 6.0 0.1 2.6 Cylinder (D) 3.2 0 1.4 0.8 Spherical equivalent 6.0 5.5 0.7 2.5

4412 Martinez-de-la-Casa et al. IOVS, October 2006, Vol. 47, No. 10 FIGURE 1. Bland-Altmann plot of Goldmann-correlated IOP (ORA) minus Goldmann IOP (GAT) versus the mean of both (slope 0.623, P 0.0001). central corneal thickness of its pressure measurements, compared with those of conventional tonometry. 14,15 The ocular response analyzer was developed with a similar purpose in mind. This instrument evaluates several biomechanical properties of the cornea and then corrects the IOP according to these properties. One of the variables measured by the ORA is the corneal hysteresis, which reflects the capacity of corneal tissue to absorb and dissipate energy. In eyes with keratoconus or Fuchs dystrophy or those undergoing corneal refractive surgery, the corneal hysteresis is significantly reduced with respect to eyes with normal corneas. 10 This corneal property is FIGURE 2. Bland-Altmann plot of corneal-compensated IOP (ORA) minus Goldmann IOP (GAT) versus the mean of both (slope 0.538, P 0.0001).

IOVS, October 2006, Vol. 47, No. 10 Ocular Response Analyzer versus Goldmann Applanation Tonometer 4413 FIGURE 3. Correlation between Goldmann-correlated IOP (ORA) and corneal-compensated IOP (ORA; r 0.909, P 0.0001). thought to be independent of IOP and is used by the instrument to calculate corneal-compensated IOP, the main variable provided by the ORA. In our series, corneal hysteresis effectively proved to be independent of the IOP GAT and correlated significantly with corneal-compensated IOP. Another variable measured by the ORA that reflects the cornea s biomechanical properties is the corneal resistance factor, which indicates the overall resistance of the cornea. Our data confirm the findings of Luce 10 indicating that cornealcompensated IOP is unaffected by the corneal resistance factor, the latter being significantly correlated with central corneal thickness and IOP GAT. In other words, the thicker the cornea and/or the higher the IOP GAT, the greater the corneal resistance factor. Both Goldmann-correlated IOP and corneal-compensated IOP significantly overestimated IOP measured with the Goldmann tonometer, with mean differences of 7.2 and 8.3 mm Hg, respectively, observed in this study. These differences are more relevant if we consider that they did not remain constant across the entire range of pressures recorded in our series, such that the discrepancy between the two tonometers becomes larger for the higher GAT-determined IOPs. This observation precludes the use of a linear correction factor to equate ORA-determined pressures with those obtained by conventional tonometry. The ORA theoretically corrects the Goldmann-correlated IOP according to the two new factors that define the biomechanical properties of the cornea (corneal hysteresis and corneal resistance factor). In this study, we provide data that could, on the one hand, support, and on the other, contradict this presumptive correction. Contrary to this correction, our results indicate significant correlation between the two pressure measurements provided by the ORA and central corneal thickness, along with excellent correlation between Goldmann-correlated IOP and cornealcompensated IOP (r 0.909, P 0.0001) and minimal differences between them (1 mm Hg), which would seem insufficient to justify an adequate correction for the wide range of corneal thicknesses used in this study. In favor of the ORAs correction method, we found a significant correlation between the corneal-compensated IOP and corneal hysteresis that was not found for the Goldmann-correlated IOP, which would indicate a certain degree of correction of this last measure according to the corneal hysteresis to give rise to the corrected pressure. Accordingly, it seems that effectively the corneal-compensated IOP is corrected for by the corneal hysteresis, but that this correction is subtle and perhaps insufficient to compensate for the central corneal thickness effect on pressure measurements. In our opinion, the main limitation of the ORA for its use in daily clinical practice is the considerable overestimation of IOP with respect to applanation tonometry and the fact that these differences progressively increase as the applanation pressure measurements increase. Thus, for patients with glaucoma, the real utility of the two new variables provided by the ORA (corneal hysteresis and corneal resistance factor) has yet to be established. References 1. Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol. 1993;38:1 30. 2. Whitacre MM, Stein RA, Hassanein K. The effect of corneal thickness on applanation tonometry. Am J Ophthalmol. 1993;115:592 596. 3. Argus WA. Ocular hypertension and central corneal thickness. Ophthalmology. 1995;102:1810 1812. 4. Chatterjee A, Shah S, Bessant DA, Naroo SA, Doyle SJ. Reduction in intraocular pressure after excimer laser photorefractive keratectomy: correlation with pretreatment myopia. Ophthalmology. 1997;104:355 359. 5. Herndon LW, Choudhri SA, Cox T, Damji KF, Shields MB, Allingham RR. Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes. Arch Ophthalmol. 1997;115:1137 1141.

4414 Martinez-de-la-Casa et al. IOVS, October 2006, Vol. 47, No. 10 6. Kass MA, Heuer DK, Higginbotham EJ, et al. The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma. Arch Ophthalmol. 2002;120:701 713. 7. Gordon MO, Beiser JA, Brandt JD, et al. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol. 2002;120:714 720. 8. Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44:367 408. 9. Orssengo GJ, Pye DC. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Math Biol. 1999;61:551 572. 10. Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005;31:156 162. 11. Luce D, Taylor D. Reichert Ocular Response Analyzer measures corneal biomechanical properties and IOP: provides new indicators for corneal specialties and glaucoma management. Ocular Response Anlyzer White Paper. Available at: http://www.ocularresponseanalyzer.com/downloads.html. Accessed September 2005. 12. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1: 307 310. 13. Gunvant P, O Leary DJ, Baskaran M, Broadway DC, Watkins RJ, Vijaya L. Evaluation of tonometric correction factors. J Glaucoma. 2005;14:337 343. 14. Kaufmann C, Bachmann LM, Thiel MA. Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthalmol Vis Sci. 2003;44:3790 3794. 15. Siganos DS, Papastergiou GI, Moedas C. Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg 2004;30:746 751.