The British Journal of Radiology, 84 (2011),

Similar documents
Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

INTRAFRACTION PROSTATE MOTION DURING IMRT FOR PROSTATE CANCER

Effect of bladder filling on doses to prostate and organs at risk: a treatment planning study

Prostate immobilization using a rectal balloon

Department of Radiotherapy & Nuclear Medicine, National Cancer Institute, Cairo University, Cairo, Egypt.

Image-guided radiotherapy of bladder cancer: Bladder volume variation and its relation to margins

Implementation of daily image-guided radiation therapy using an in-room CT scanner for prostate cancer isocentre localization

OPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING

Linac Based SBRT for Low-intermediate Risk Prostate Cancer in 5 Fractions: Preliminary Report of a Phase II Study with FFF Delivery

Interfraction Prostate Movement in Bone Alignment After Rectal Enema for Radiotherapy

Outcomes Following Negative Prostate Biopsy for Patients with Persistent Disease after Radiotherapy for Prostate Cancer

UvA-DARE (Digital Academic Repository) Towards image-guided radiotherapy of prostate cancer Smitsmans, M.H.P. Link to publication

Treatment Planning Volume According to Change in Bladder Volume in Therapy of Proton Beam in Magnetic Field

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

Impact of Contouring Variability on Dose- Volume Metrics used in Treatment Plan Optimization of Prostate IMRT

Margin Reduction in Prostate. Radiotherapy. Richard Oates, A/Prof Michal Schneider Monash Prof Tomas Kron Peter Mac Dr Michael Lim Joon Peter Mac

An analysis of geometric uncertainty calculations for prostate radiotherapy in clinical practice.

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

New Technologies for the Radiotherapy of Prostate Cancer

Statistical Analysis and Volumetric Dose for Organ at Risk of Prostate Cancer

Prostate Cancer. 3DCRT vs IMRT : Hasan Murshed

CBCT of the patient in the treatment position has gained wider applications for setup verification during radiotherapy.

The British Journal of Radiology, 82 (2009),

BLADDER RADIOTHERAPY PLANNING DOCUMENT

Automatic Definition of Planning Target Volume in Computer-Assisted Radiotherapy

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 6, 2016

biij Initial experience in treating lung cancer with helical tomotherapy

Margins in SBRT. Mischa Hoogeman

Application of asi-kvcbct for Volume Assessment and Dose Estimation: An Offline Adaptive Study for Prostate Radiotherapy

Clinical Management Guideline for Planning and Treatment. The process to be followed when a course of chemotherapy is required to treat:

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015

Feasibility of 4D IMRT Delivery for Hypofractionated High Dose Partial Prostate Treatments

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

The sigmoid colon and bladder shielding in whole pelvic irradiation at prostate cancer (forward planned IMRT from Institute of Oncology Ljubljana)

The impact of IGRT for prostate radiotherapy on dosimetry and the traditional workflow practice of focus to skin distance measurements

A PRACTICAL METHOD TO ACHIEVE PROSTATE GLAND IMMOBILIZATION AND TARGET VERIFICATION FOR DAILY TREATMENT

Dosimetric effects of prone and supine positions on post-implant assessments for prostate brachytherapy

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

I. Equipments for external beam radiotherapy

doi: /j.ijrobp CLINICAL INVESTIGATION

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

Radiation Therapy for Prostate Cancer. Resident Dept of Urology General Surgery Grand Round November 24, 2008

The use of SpaceOAR hydrogel in dose-escalated prostate cancer radiotherapy and its impact on rectal dosimetry

IMRT for Prostate Cancer

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 6, NUMBER 2, SPRING 2005

4D Radiotherapy in early ca Lung. Prof. Manoj Gupta Dept of Radiotherapy & oncology I.G.Medical College Shimla

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

Would SBRT Hypofractionated Approach Be as Good? Then Why Bother With Brachytherapy?

Development of a treatment planning protocol for prostate treatments using intensity modulated radiotherapy

HIGH DOSE RADIATION DELIVERED BY INTENSITY MODULATED CONFORMAL RADIOTHERAPY IMPROVES THE OUTCOME OF LOCALIZED PROSTATE CANCER

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Research Article Implant R100 Predicts Rectal Bleeding in Prostate Cancer Patients Treated with IG-IMRT to 45 Gy and Pd-103 Implant

INFLUENCE OF CT SLICE THICKNESS ON VOLUME AND DOSE UNCERTAINTY FOR DIFFERENT ORGANS DURING TREATMENT PLANNING FOR EARLY PROSTATE CANCER

Role of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation

REVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria

Patient positioning and treatment instructions used during radiation therapy of the prostate: results of an Australian and New Zealand survey

Measure the Errors of Treatment Set-Ups of Prostate Cancer Patient Using Electronic Portal Imaging Device (EPID)

CyberKnife Radiotherapy For Localized Prostate Cancer: Rationale And Technical Feasibility

Nordic Society for Gynecological Oncology Advisory Board of Radiotherapy

Illawarra Cancer Care Centre

Target localization for post-prostatectomy patients using CT and ultrasound image guidance

Corporate Medical Policy

Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment

Radiation Planning Index for dose distribution evaluation in stereotactic radiotherapy

Prostate Cancer in comparison to Radiotherapy alone:

Comparison of multileaf collimator and customized blocks for 3-D conformal radiotherapy of prostate cancer with six-field technique

Vaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer. Scott Boulet BSc, RT(T)

7/16/2009. Cost-benefit, QALYs and the Value of a Statistical Life

The Phoenix Definition of Biochemical Failure Predicts for Overall Survival in Patients With Prostate Cancer

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS

UvA-DARE (Digital Academic Repository) (Un-)certainties in radiotherapy of rectal cancer Nijkamp, J.A. Link to publication

External Beam Radiation Therapy for Low/Intermediate Risk Prostate Cancer

Lewis Garvey Smith III, MD Reference List

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies

Organ Contour Adaptor to create new structures to use for adaptive radiotherapy of cervix cancer using Matlab Bridge and 3DSlicer / SlicerRT

Radiobiological Impact of Planning Techniques for Prostate Cancer in Terms of Tumor Control Probability and Normal Tissue Complication Probability

Andrew K. Lee, MD, MPH Associate Professor Department tof fradiation Oncology M.D. Anderson Cancer Center

Absolute volume of the rectum and AUC from rectal DVH between 25Gy and 50Gy predict acute gastrointestinal toxicity with IG-IMRT in prostate cancer

Outline - MRI - CT - US. - Combinations of imaging modalities for treatment planning

The effect of bowel preparation regime on interfraction rectal filling variation during image guided radiotherapy for prostate cancer

20 Prostate Cancer Dan Ash

The Evolution of RT Techniques for Gynaecological Cancers in a developing country context

Vol. 36, pp , 2008 T1-3N0M0 : T1-3. prostate-specific antigen PSA. 68 Gy National Institutes of Health 10

Post Radical Prostatectomy Radiation in Intermediate and High Risk Group Prostate Cancer Patients - A Historical Series

The Physics of Oesophageal Cancer Radiotherapy

Treatment of exceptionally large prostate cancer patients with low-energy intensity-modulated photons

EVALUATION OF THERAPEUTIC POTENTIAL OF HEAVY ION THERAPY FOR PATIENTS WITH LOCALLY ADVANCED PROSTATE CANCER

Evaluation of three APBI techniques under NSABP B-39 guidelines

Changing Paradigms in Radiotherapy

Determining optimal planning target volume and image guidance policy for post-prostatectomy intensity modulated radiotherapy

ART for Cervical Cancer: Dosimetry and Technical Aspects


Helical Tomotherapy Experience. TomoTherapy Whole Brain Head & Neck Prostate Lung Summary. HI-ART TomoTherapy System. HI-ART TomoTherapy System

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Medicare Program: Changes to Hospital Outpatient Prospective Payment and Ambulatory Surgical Center Payment Systems and Quality Reporting Programs

Stepping source prostate brachytherapy: From target definition to dose delivery Dinkla, A.M.

Johannes C. Athanasios Dimopoulos

Transcription:

The British Journal of Radiology, 84 (2011), 813 818 Assessing the daily consistency of bladder filling using an ultrasonic Bladderscan device in men receiving radical conformal radiotherapy for prostate cancer 1 S HYNDS, MSc, 2 C K McGARRY, MSc, 1 D M MITCHELL, FRCR, 1 S EARLY, BSc, 1 L SHUM, FRCR, 1 D P STEWART, FRCR, 1 J A HARNEY, FRCR, 4 C R CARDWELL, PhD and 1,3 J M O SULLIVAN, FFRRSCI 1 Radiotherapy Department, Northern Ireland Cancer Centre Belfast City Hospital, Belfast, UK, 2 Medical Physics Department, Belfast City Hospital, Belfast, UK, 3 Centre for Cancer Research and Cell Biology, and 4 Department of Epidemiology and Public Health, The Queen s University, Belfast, UK Objective: Consistency in target organ and organ at risk position from planning to treatment is an important basic principle of radiotherapy. This study evaluates the effectiveness of bladder-filling instructions in achieving a consistent and reproducible bladder volume at the time of planning CT and daily during the course of radical radiotherapy for prostate cancer. It also assessed the rate of bladder filling before and at the end of radiotherapy. Methods: 30 men attending for radiation therapy planning for prostate cancer received written and verbal bladder-filling instructions. They had their bladder volume assessed using a bladder ultrasound scanner post-void, immediately prior to planning CT scan and then daily immediately prior to treatment while in the therapy position. The inflow was calculated using the void and full bladder volumes and the time for the bladder to fill. Results: The mean bladder volume at the time of planning was 282 ml (range 89 608 ml, standard deviation (SD)5144.5 ml). This fell during treatment, with a mean value for all treatments of 189 ml (range 11 781 ml, SD5134 ml). During radiotherapy, 76% (828/1090), 53% (579/1090) and 36% (393/1090) of bladder volumes had.50 ml,.100 ml and.150 ml difference, respectively when compared with their volume at the time of planning. Inflow reduced from 4.6 ml min 1,SD52.9 min 1 at planning to 2.5 min 1,SD51.8 min 1 after radiotherapy. Conclusion: The Bladderscan device (BVI 6400 Bladderscan, Verathon Medical UK, Sandford, UK) provides an effective means of assessing bladder volume prior to radiotherapy for prostate cancer. The evaluated bladder-filling protocol does not produce consistent, reproducible bladder volumes for radiotherapy. Received 19 March 2010 Revised 1 May 2010 Accepted 5 May 2010 DOI: 10.1259/bjr/50048151 2011 The British Institute of Radiology Reproducibility of target volume position is a fundamental component of external beam radiotherapy at any site, but is of particular importance where a doseescalated regimen is being employed and where the surrounding organs are both dose and volume sensitive. For men receiving dose-escalated radical prostate radiotherapy, a consistent bladder volume between planning and treatment is vital. Although there are differing opinions on the influence of bladder volume on interfraction prostate position [1 7], the influence of the irradiated bladder volume on acute and late urinary [8] and bowel toxicity [2, 9] has been well documented. Despite the apparent importance of controlling bladder volume for prostate radiotherapy, there is surprisingly limited research into the provision of bladder-filling instructions that produce acceptable dose volume histograms (DVHs) and provide a reproducible bladder Address correspondence to: Dr Darren M Mitchell, Consultant in Clinical Oncology, Northern Ireland Cancer Centre, Belfast City Hospital, Lisburn Road, Belfast BT9 7AB, UK. E-mail: dmmitchell@doctors.org.uk volume from planning through to treatment [1 2, 10, 11] rather than an unreliable and misleading snapshot at the time of planning. This study was designed to first validate bladder volume measurements using a non-invasive transabdominal bladder ultrasound device (BVI 6400 Bladderscan, Verathon Medical UK, Sandford, UK) before using it to evaluate the effectiveness of standardised bladder-filling instructions in achieving a consistent and reproducible bladder volume from the time of planning and during each daily fraction of radical radiotherapy for prostate cancer. The data obtained would then be used to inform changes in bladder-filling instructions before future re-evaluation. There is a basic assumption in trying to obtain a standardised bladder volume that the rate at which a bladder fills after a defined fluid load is relatively constant. This has been previously confirmed in healthy volunteers [12] but not in men receiving radiotherapy for prostate cancer. The study was also designed to assess bladder inflow rate in such a group at the time of radiotherapy planning and on the final fraction of radiotherapy. The British Journal of Radiology, September 2011 813

S Hynds, C K McGarry, D M Mitchell et al Methods and materials Patients After ethical approval (REC ref: 08/NIRO3/70) and based on a review of previous literature [1, 10] and a small pilot study in our centre, 30 consecutive men attending for radical external beam radiotherapy planning for their localised prostate cancer between August 2008 and January 2009 gave written informed consent to enter the study. They received written and verbal advice on bladder filling prior to their CT planning appointment. The advice was to \void the bladder and then drink 500 ml of water within the next 15 minutes. 30 minutes later proceed with the radiotherapy planning scan. This process should then be repeated daily prior to each treatment". All men were being treated with radiotherapy as the primary definitive therapy for their prostate cancer, and received 3 months of neo-adjuvant hormonal therapy prior to radiation planning. All had an anatomically normal functioning bladder and had minimal lower urinary tract symptoms defined as a pre-treatment international prostate symptom score (IPSS) of less than 7. Bowel preparation with a single microenema was administered prior to voiding at the time of planning and repeated daily prior to each treatment. The use of a- blockade during radiotherapy, weekly IPSS and acute Radiation Therapy Oncology Group (RTOG) toxicity criteria from baseline were recorded. Radiotherapy planning and treatment Planning and treatment were performed with the patient in a supine position with a knee rest. CT slices were obtained at 2.5 mm intervals on a Siemens Emotion 6 CT Scanner (Siemens Healthcare, Camberley, UK). Target and critical structures including the bladder and rectum were delineated by the attending radiation oncologist and reviewed by a singe physicist on the Oncentra Masterplan treatment planning system (Nucletron, Veenendal, The Netherlands). Three-dimensional (3D) conformal radiotherapy was delivered using a 15 MV accelerator in a 2 phase plan treating the prostate and base of seminal vesicles to 64 Gy in 32 fractions with a 10 mm margin, except posteriorly where 8 mm was used. A final 10 Gy in 5 fractions was delivered with no margin. Bladder ultrasound scan protocol A bladder ultrasound scan was performed by a therapy radiographer directly after voiding and then immediately before the planning CT scan while on the CT couch (approximately 45 min post-fluid load). The time of each ultrasound scan was documented. The bladder volume was also calculated from the CT planning scan. Patients followed current bladder-filling instructions and then had an ultrasound scan performed immediately prior to each daily fraction of radiotherapy while on the treatment couch. A post-void volume was also recorded on the final fraction. Patients were not informed of their volume results to prevent falsely consistent volumes occurring via a biofeedback mechanism. The therapy radiographers were trained and supervised for their first 30 scans before being deemed competent. Each ultrasound scan took approximately 1 2 min and had no impact on overall treatment time. Analysis Validation of the ultrasound bladder volume measurements was performed by means of comparison with the corresponding CT scan volume using a Pearson correlation, a paired Student s t-test (assuming normality) and a Bland Altman plot. Statistical analysis was performed using SPSS (Version 17; Chicago, IL). Linear regression was used to calculate the average reduction in bladder volume per session using robust standard errors to account for the lack of independence of observations from the same person (Kirkwood and Sterene Medical Statistics; STATA version 9). Pearson s correlation coefficients were used to investigate the association between different characteristics (IPSS, age, Gleason, prostate-specific antigen (PSA) and glomerular filtration rate (GFR)) and average bladder volume and standard deviation. Spearman s correlation coefficient was used to investigate the association between ranked characteristics such as Gleason and T stage and explanatory variables. The spread of bladder volumes measured over the course of treatment was compared with the pretreatment volume for each patient. A linear regression analysis adjusting for the lack of independence to account for the fact that the same 30 patients were scanned on each session was performed to analyse the changes in bladder volume over the course of treatment. Inflow was calculated by taking the difference between the post-void volume on ultrasound scan and the full bladder ultrasound scan volume and dividing by the time between scans. This was performed during the CT planning appointment and on the final day of treatment. A Student s t-test was performed to assess the statistical significance of any differences (p,0.05). Any changes between these inflows were correlated with the change in bladder volumes on these specific days. Results 30 men with a median age of 67 years (range 56 78 years) were assessed. The hand-held ultrasound device was well tolerated, with 98% (1090/1110) of proposed scans performed and no men requiring a-blockade during radiotherapy. The validity of the volume measured by the ultrasound scanner was confirmed by comparison of the volume it calculated immediately prior to CT planning and the volume calculated on the CT scan data set using Oncentra Masterplan (Pearson correlation coefficient 0.91). Figure 1 demonstrates the relationship between the average of the bladder volumes (CT and ultrasound scan) and the difference between these readings, which is not constant, with larger volumes demonstrating a 814 The British Journal of Radiology, September 2011

Bladder filling prior to prostate radiotherapy Figure 1. A plot demonstrating the relationship between the average of the bladder volumes (CT and Bladderscan BV) at the time of planning and the difference between these values with the limits of agreement added. greater difference (Spearman s correlation coefficient 0.38, p50.04). volumes for that week for each patient, but revealed no correlation. Patient bladder volumes The mean volume on ultrasound at the time of planning was 282 ml (range 89 608 ml, SD5144.5 ml) and the mean CT volume was 291 ml (range 87 579 ml, SD5162 ml). A paired Student s t-test showed that these were not statistically different (p50.29). The average volume fell during treatment, with a mean value for all treatments of 189 ml (range 11 781 ml, SD5134 ml) and on the final day of treatment the mean value was 165 ml (range 64 339 ml, SD5138 ml). Figure 2 shows the spread of bladder volumes measured over the course of the treatment compared with the pre-treatment volumes for each patient. Based on the coefficient of variation (CoV), the most and least variable patients had median values of 62 ml (range 29 461 ml, SD583 ml, CoV586) and 473 ml (range 124 728, SD5159 ml, CoV5 35), respectively. During radiotherapy, 76% (828/1090), 53% (579/1090) and 36% (393/1090) of bladder volumes had a.50 ml,.100 ml and.150 ml difference, respectively, when compared with their volume at the time of planning. All men had a.50% reduction in their ultrasound volume on at least 1 occasion during treatment when compared with their planning volume. No correlations were observed between patient characteristics (age, Gleason, PSA and T stage) or GFR compared with the average bladder volume, standard deviation (ml) or standard deviation (%). IPSS score at each week was also compared with the average Bladder volume and inflow over time The mean time from void to bladder ultrasound immediately before the CT planning was 47.3 min (range 25 70 min) and from void to bladder ultrasound immediately before the final treatment was 45.5 min (range 10 139 min), p50.8. There was an average decrease in bladder volume per visit of 1 ml (p50.026; 95% CI 0.1 2.1) from linear regression using robust standard errors to adjust for correlated observations in patients. While the majority of cases had no apparent trend in bladder volume reduction over the course of their radiotherapy, a few had a clear reduction, with the most obvious having a 7 ml decrease in bladder volume per day. Average pre-treatment inflow was found to be 4.6 2.9 min 1 and was 2.5 1.8 min 1 after radiotherapy, which was a statistically significant reduction (p50.0003). It can be seen in Figure 3 that bladder volumes decrease over the course of radiotherapy. When the difference in inflow rate and the difference in bladder volume pre- and post-radiotherapy were assessed (Figure 4), a Pearson correlation of 0.79 was noted. The reduction in bladder inflow rate was not related to the calculated GFR (Cockcroft Gault formula). Discussion Daily ultrasound assessment using a hand-held bladder ultrasound scanner is an effective, well-tolerated and The British Journal of Radiology, September 2011 815

S Hynds, C K McGarry, D M Mitchell et al Figure 2. Individual patient bladder volumes from both ultrasound (pre-rt BS volume) and CT at the time of planning and daily immediately prior to radiotherapy (RT BS volume). RT, radiotherapy; BS, bladder scanning. non-invasive method of evaluating the bladder volume prior to radiotherapy treatment in the studied group. It provides an accurate assessment of bladder volume when compared with volumes calculated on a CT planning system, but may slightly underestimate the volume where the values are greater than 300 ml. In this cohort of men, the evaluated bladder-filling instructions fail to provide consistent and reproducible bladder filling from CT planning through a course of radiotherapy, with a progressive reduction in mean bladder volume over the duration of treatment. This finding concurs with other published work [1, 8]. None of the evaluated factors predicted for this inconsistency. While this study does not examine the effect of changing bladder volume on prostate position for radiotherapy, it clearly demonstrates the fallibility of DVHs in providing an accurate assessment of the actual radiation dose delivered to the bladder in this study population. In 21 of 30 (70%) men, the average bladder volumes were lower than the planning scan, and in 8 of 30 (27%) the average bladder volume over the course of treatment was more than 50% lower than the volume at the time of planning. The DVH data provided by the CT planning scan would therefore have underestimated the dose delivered to the bladder in 70% of treatments. There are three ways to apply this information. First, assuming that patients had no post-void residual volume, asking men to empty their bladder immediately prior to radiotherapy would remove any potential effect of variable bladder filling on prostate motion [7]. However, the dose delivered to the bladder and small bowel particularly in the dose escalation era would be expected to lead to increased acute and late toxicity in these organs [2]. Unfortunately, post-void residual volumes are often seen and provide a further source of variability. Figure 3. A box plot demonstrating the median, interquartile range and whisker s indicating the 90th and 10th percentile of daily bladder volume in all patients through the course of radiotherapy. 816 The British Journal of Radiology, September 2011

Bladder filling prior to prostate radiotherapy Figure 4. Direct relationship between the difference in inflow before and after radiotherapy compared with bladder volume before and after radiotherapy for prostate cancer patients. Second, continuing to plan radiotherapy with a large fluid load that, although difficult to reproduce through treatment, provides acceptable but unreliable DVHs. Assuming prostate position is not influenced by the change in bladder volume, then this could be a valid strategy. If, however, the prostate position is influenced by bladder filling, then as the bladder volume reduces over the course of treatment and if rectal volume is unchanged, the prostate would move anteriorly. Given the more generous anterior margins typically applied in expanding the clinical target volume (CTV) to planning target volume (PTV), the possibility of a geometric miss would be much less likely [3]. Finally, applying the general principle of consistency in patient set-up, a bladder-filling protocol should be developed that is reproducible and has limited variability with DVHs representative of the course of treatment. Several methods of reducing the variability of bladder volume have been examined in this setting. Stam et al [1] reduced the variability of the bladder volume through the use of a biofeedback mechanism with daily ultrasound assessment. The average bladder volume during treatment was 94.6% of the CT planning volume with biofeedback compared with 83.2% without biofeedback (p50.38). O Doherty et al [10] demonstrated how the provision of written bladder-filling instructions to patients helped to keep the average bladder filling during treatment closer to the volume at CT planning than patients who had not received the written instructions. This study has described in detail how the bladder volume can change on a daily basis. This has been invaluable in gaining an insight into daily variations. We are also now in the position where we can examine the frequency of bladder scanning that would be required to assess the overall bladder-filling protocol. Taking a weekly reading shows that the average 193.9 ml 136.6 ml is not significantly different from the daily average of 189.1 ml 134.8 ml (p50.83). Three readings at the start, middle and end of treatment would yield a significant difference (p50.02) from the daily analysis and therefore may not be adequate for full analysis of the bladder-filling protocol. This information can be transferred for use by in-line soft-tissue imaging such as cone beam CT, with weekly scans required to evaluate organ position and filling. The hypothesis that the rate at which the bladder fills is constant after a defined fluid load has not been supported by this study. Although the intravolunteer variation (SD52.9 ml min 1 pre-radiotherapy and 1.8 ml min 1 post-radiotherapy) is similar to those quoted by Lotz et al [12] (SD53.0 ml min 1 ), the younger healthy volunteers studied by Lotz had minimal variation in their inflow rate compared with the significant reduction in inflow rate from planning to the end of treatment in the men in our study. Bladder filling is not a simple input output calculation, as it is affected by the patient s state of hydration, time of day and concomitant medication, and the complexities of renal blood flow must be considered. Non-compliance with the protocol resulted from men either reducing their fluid load as bladder irritation increases over the course of treatment or reducing the period of time from void to load to treatment as they became more concerned about maintaining the fluid load for the recommended time. It is important that this reduction in inflow is taken into account when assessing bladder-filling protocols. Most studies have seen a reduction in bladder volume over the course of radiotherapy [1, 8]. We acknowledge the limited size of our population and recommend that this finding should be confirmed in a larger population, with inflow calculations performed more frequently during treatment. This study would also be improved by using cone beam CT, providing daily DVH data as well as assessing organ motion, which is not available with the ultrasound bladder scanner. While there should be continued focus on compliance with bladder-filling instructions, the reduction in inflow over treatment is a useful finding, suggesting that patients should be encouraged to progressively increase their fluid load as their treatment progresses. Conclusion The bladder-filling protocol evaluated in this study fails to provide reproducible and consistent bladder volumes from the time of planning through to daily treatment for prostate cancer, with the volume at CT planning generally overestimating the volume achieved during treatment. The reduction in bladder volume over the course of radiotherapy may not only be due to poor compliance to bladder-filling instructions, but also due to the inability to fill the bladder within a specified time, as demonstrated by the reduction in inflow. Further investigative research is planned to compare the effectiveness of different bladder-filling protocols in achieving a reproducible bladder volume for prostate radiotherapy. Acknowledgment A donation provided by the Friends of the Cancer Centre purchased and maintained the Bladderscan BVI 6400 device used in the study. The British Journal of Radiology, September 2011 817

S Hynds, C K McGarry, D M Mitchell et al References 1. Stam MR, Van Lin ENJ, Van Der Vight LP, Kaanders JHAM, Visse AG. Bladder filling variation during radiation treatment of prostate cancer: can the use of a bladder ultrasound scanner and biofeedback optimize bladder filling? Int J Rad Oncol Biol Phys 2006;65:371 7. 2. Pinkawa M, Asadpour B, Gagel B, Piroth MD, Holy R, Eble MJ. Prostate position variability and dose-volume histograms in radiotherapy for prostate cancer with full and empty bladder. Int J Radiat Oncol Biol Phys 2006;64: 856 61. 3. Langen KM, Jones DTL. Organ motion and it s management. Int J Radiat Oncol Biol Phys 2001;50:265 78. 4. Antolak JA, Rosen II, Childress CH, Zagars GK, Pollack A. Prostate target volume variation during a course of radiotherapy. Int J Radiat Oncol Biol Phy 1998;42:661 72. 5. Zellars RC, Roberson PL, Stawderman M, Zhang D, Sandler HM, Ten Haken RK, et al. Prostate position late in the course of external beam radiotherapy: patterns and predictors. Int J Rad Oncol Biol Phys 2000;47:655 60. 6. Roeske JC, Forman JD, Mesina CF, He T, Pelizzari CA, Fontenla E, et al. Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder and rectum during a course of external beam radiotherapy. Int J Rad Oncol Biol Phys 1995;33:1321 9. 7. Zelefsky MJ, Crean D, Mageras GS, Lyass O, Happersett L, Ling C, et al. Quantification and predictors of prostate position variability in 50 patients evaluated with multiple CT scans during conformal radiotherapy. Radiother Oncol 1999;50:225 34. 8. Lebesque JV, Bruce AM, Kroes APG, Touw A, Shouman T, van Herk M. Variation in volumes, dose-volume histograms, and estimated normal tissue complications probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer. Int J Rad Oncol Biol Phys 1995;33: 1109 19. 9. Storey MR, Pollack A, Zagars G, Smith L, Antolak J, Rosen I. Complications from radiotherapy dose escalation in prostate cancer: preliminary results of a randomized trial. Int J Radiat Oncol Biol Phys 2000;48:635 42. 10. O Doherty UM, McNair HA, Norman AR, Miles E, Hooper S, Davies M, et al. Variability of bladder filling in patients receiving radical radiotherapy to the prostate. Radiother Oncol 2006;79:335 40. 11. Moiseenko V, Liu M, Kirstensen S, Gelowitz G, Berthelet E. Effect of bladder filling on doses to prostate and organs at risk: a treatment planning study. J Appl Clin Med Phys 2007;8:55 67. 12. Lotz HT, van Herk M, Betgen A, Pos F, Lebesque JV, Remeijer P. Reproducibility of the bladder shape and bladder shape changes during filling. Med Phys 2005;32:2590 7. 818 The British Journal of Radiology, September 2011