The association of the uterine motion with bladder volume during radiotherapy in gynecological malignancies

Similar documents
Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

Does conformal therapy improve dose distribution in comparison to old techniques in teleradiotherapy of cervical cancer patients?

Specification of Tumor Dose. Prescription dose. Purpose

REVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

Defining Target Volumes and Organs at Risk: a common language

ART for Cervical Cancer: Dosimetry and Technical Aspects

Application of asi-kvcbct for Volume Assessment and Dose Estimation: An Offline Adaptive Study for Prostate Radiotherapy

Implementation of Gynaecological IMRT Planning Technique Clinical Guidelines and Constraints. Chloe Pandeli

Comparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy

CALCULATION OF OPTIMAL MARGINS BETWEEN CLINICAL TARGET VOLUME (CTV) AND PLANNING TARGET VOLUME (PTV)

The New ICRU/GEC ESTRO Report in Clinical Practice. Disclosures

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

Basic Concepts in Image Based Brachytherapy (GEC-ESTRO Target Concept & Contouring)

CBCT of the patient in the treatment position has gained wider applications for setup verification during radiotherapy.

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

NEWER RADIATION (3 D -CRT, IMRT, IGRT) TECHNIQUES FOR CERVICAL CANCERS (COMMON PELVIC TUMORS)

Nordic Society for Gynecological Oncology Advisory Board of Radiotherapy

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

PRINCESS MARGARET CANCER CENTRE CLINICAL PRACTICE GUIDELINES GYNECOLOGIC CANCER CERVIX

BLADDER RADIOTHERAPY PLANNING DOCUMENT

Bone Marrow Dosimetric Parameters and Hematological Toxicity In Cervical Cancer Patients Undergoing Concurrent Chemoradiation.

Dosimetric consequences of tumor volume changes after kilovoltage cone-beam computed tomography for non-operative lung cancer during adaptive

Department of Radiotherapy & Nuclear Medicine, National Cancer Institute, Cairo University, Cairo, Egypt.

The Evolution of RT Techniques for Gynaecological Cancers in a developing country context

Margins in SBRT. Mischa Hoogeman

Measure the Errors of Treatment Set-Ups of Prostate Cancer Patient Using Electronic Portal Imaging Device (EPID)

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

Role of IMRT in the Treatment of Gynecologic Malignancies. John C. Roeske, PhD Associate Professor The University of Chicago

From position verification and correction to adaptive RT Adaptive RT and dose accumulation

3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER

La Pianificazione e I Volumi di Trattamento

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

Protocol. Intensity-Modulated Radiation Therapy (IMRT): Abdomen and Pelvis

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Herlev radiation oncology team explains what MRI can bring

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015

Comparison of Three-Dimensional Conformal Radiotherapy and Intensity-Modulated Radiation Therapy ORIGINAL STUDY

Outline - MRI - CT - US. - Combinations of imaging modalities for treatment planning

doi: /j.ijrobp CLINICAL INVESTIGATION

Chapters from Clinical Oncology

Dose-Volume Histogram Analysis in Point A-based Dose Prescription of High-dose-rate Brachytherapy for Cervical Carcinoma

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

DICHIARAZIONE Relatore: Andrea Vavassori

IMRT for Prostate Cancer

8/3/2016. Outline. Site Specific IGRT Considerations for Clinical Imaging Protocols. Krishni Wijesooriya, PhD University of Virginia

VAGINAL MOTION AND BLADDER AND RECTAL VOLUMES DURING PELVIC INTENSITY-MODULATED RADIATION THERAPY AFTER HYSTERECTOMY

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

Chapter 2. Level II lymph nodes and radiation-induced xerostomia

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

The Physics of Oesophageal Cancer Radiotherapy

Implementation of advanced RT Techniques

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

MRI Based treatment planning for with focus on prostate cancer. Xinglei Shen, MD Department of Radiation Oncology KUMC

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Changing Paradigms in Radiotherapy

Vaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer. Scott Boulet BSc, RT(T)

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment

International Journal of Health Sciences and Research ISSN:

Image Guided Stereotactic Radiotherapy of the Lung

Potential systematic uncertainties in IGRT when FBCT reference images are used for pancreatic tumors

RADIOTHERAPY IN THE MANAGEMENT OF CANCERS OF THE URINARY BLADDER

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

New Technologies for the Radiotherapy of Prostate Cancer

Role of MRI in Intracavitary Brachytherapy for Cervical Cancer: What the Radiologist Needs to Know

OPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING

Overview of Advanced Techniques in Radiation Therapy

High-Dose-Rate Orthogonal Intracavitary Brachytherapy with 9 Gy/Fraction in Locally Advanced Cervical Cancer: Is it Feasible??

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 6, 2016

Wenjuan Chen, MD 1, Penggang Bai, MS 1, Jianji Pan, MD 1, Yuanji Xu, MD 1, and Kaiqiang Chen, MS 1. Introduction. Radiotherapy

8/1/2017. Clinical Indications and Applications of Realtime MRI-Guided Radiotherapy

Role of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation

Corporate Medical Policy

Radiotherapy Advances

Aytul OZGEN 1, *, Mutlu HAYRAN 2 and Fatih KAHRAMAN 3 INTRODUCTION

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Early clinical outcomes of 3D-conformal radiotherapy using. accelerated hyperfractionation without intracavitary brachytherapy

Organ Contour Adaptor to create new structures to use for adaptive radiotherapy of cervix cancer using Matlab Bridge and 3DSlicer / SlicerRT

Margin Reduction in Prostate. Radiotherapy. Richard Oates, A/Prof Michal Schneider Monash Prof Tomas Kron Peter Mac Dr Michael Lim Joon Peter Mac

TRANS-TASMAN RADIATION ONCOLOGY GROUP INC. Quality Assurance. Treatment Planning Benchmark

To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence

7/16/2009. Cost-benefit, QALYs and the Value of a Statistical Life

A Thesis. entitled. based on CBCT Data Dose Calculation. Sukhdeep Kaur Gill. Master of Science Degree in Biomedical Science

Stereotactic MR-guided adaptive radiation therapy (SMART) for locally advanced pancreatic tumors

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

ASTRO econtouring for Lymphoma. Stephanie Terezakis, MD

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

The Impact of Image Guided Radiotherapy in Breast Boost Radiotherapy

Image guided brachytherapy in cervical cancer Clinical Aspects

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS

Pitfalls in SBRT Treatment Planning for a Moving Target

Corporate Medical Policy

Course Directors: Teaching Staff: Guest Lecturers: Local Organiser: ESTRO coordinator: Melissa Vanderijst, project manager (BE)

Transcription:

Original Article The association of the uterine motion with bladder volume during radiotherapy in gynecological malignancies Bhandari Virendra, Mutneja Abhinav, Gurjar Omprakash, Saadvik Raghuram, Bagdare Priyusha, Gupta Krishnlal, Singh Kanchan Department of Radiation Oncology, Sri Aurobindo Medical College and PG Institute, Indore 452001, India. Correspondence to: Dr. Bhandari Virendra, Department of Radiation Oncology, Sri Aurobindo Medical College and PG Institute, 401, Samyak Towers, 16/3 Old Palasia, Indore 452001, India. E-mail: virencancer@yahoo.co.in ABSTRACT Aim: This study was performed to assess the extent of interfraction uterine motion during radiotherapy for cervical cancer and uterine body carcinoma while maintaining a strict bladder filling protocol. Methods: Twenty-four patients with cervical cancer or uterine body carcinoma who were treated on a linear accelerator, were recruited. During the course of external beam radiotherapy, cone beam computed tomographic scans were taken, once at the start of treatment and then weekly until the completion of the radiotherapy course. Patients were instructed to maintain a strict bladder filling protocol. After negating the effect of patient s setup error by offline cone beam computed tomographic imaging, the position of the uterus was defined in the clinical target volume. Then the position of the uterus was compared in the following weekly scans. The position of the uterus was also correlated with the position and the filling of the bladder. This change in uterus position was measured separately in the anterioposterior (AP), superioinferior (SI), and lateral directions. Results: According to calculations based on weekly imaging, The mean values of shift in AP, SI, and lateral directions were respectively 0.67, 0.29, and 0.23 The mean extent of motion in the uterine position on a daily basis for individual patients ranged from -2.28 to +1.3 in AP, -0.56 to +0.71 in SI, and from -0.6 to +0.45 in lateral directions. Conclusion: At least once a week cone beam computed tomography might be necessary to minimize the geometrical miss and deliver the planned doses to the target tissue and normal structure provide best results with minimum toxicity by maintaining a bladder volume of about 100 ml and an empty rectum during the whole course of treatment. The daily anatomical shift and contour of the patients maintaining a bladder volume of approximately 100 ml with an empty rectum may result in asymmetrical conforming to the planning target volume and hence appropriate and adequate planning target volume margins are required. Key words: Uterine motion; weekly computed tomographic evaluation; intensity modulated radiotherapy; inter-fraction variation; bladder volume INTRODUCTION External beam radiotherapy (EBRT) plays a great role in the management of female gynecologic cancers. Intensity modulated radiotherapy (IMRT) and image guided radiotherapy (IGRT) are considered the treatment of choice for cervical cancer and uterus carcinomas. These new techniques have overtaken the conventional four-field box technique as the preferred modality of treatment and have proven more efficacious in various studies. [1-3] The IGRT further reduces the radiation dose to the organs at risk (OAR) and thus further reduces toxicities. On the other hand, IMRT has very strict clinical and planning target volumes (CTV and PTV respectively) conforming to a particular volume to Access this article online Quick Response Code: Website: http://jcmtjournal.com DOI: 10.20517/2394-4722.2015.68 spare the adjacent organs; however, it does not account for interfraction and intrafraction motion of various organs as well as reduction in tumor volume during treatment. This phenomenon did not need to be considered in the conventional technique as it provided a uniform dose to all the structures included in the treatment field which avoids a geometrical miss of the tumor. Therefore, motion of organs within the treatment area is a vital issue in IMRT and three dimensional conformal radiotherapy (3D-CRT). During the treatmenta steep dose gradient is usually present that uses This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. For reprints contact: service@oaepublish.com How to cite this article: Virendra B, Abhinav M, Omprakash G, Raghuram S, Priyusha B, Krishnlal G, Kanchan S. The association of the uterine motion with bladder volume during radiotherapy in gynecological malignancies. J Cancer Metasta Treat 2016;2:139-43. Received: 03-09-2015; Accepted: 19-12-2015. 2016 Journal of Cancer Metastasis and Treatment Published by OAE Publishing Inc. 139

the newer techniques that conform to the optimum dose of the CTV or the shape of the target volume. Even a little geometrical movement could result in an underdosing to the target volume or conversely, delivering high undesirable doses to the surrounding normal tissues. These effects highlight the importance of accurate margin determination. This pilot study was conducted to define the daily uterine shift in patients undergoing external radiotherapy on linear accelerators with IMRT technique using IGRT with the help of an on-board cone beam computed tomography (CBCT) scan taken once a week during the whole course of radiotherapy. Figure 1: The perfect bone to bone matching of a patient with the reference computed tomographic image and the uterine shift between the two scans to negate the effect of the patient s setup errors METHODS We recruited 24 patients with the ages of 45 and 70 years who were diagnosed with cervical cancer and uterine body carcinoma were treated with EBRT (50 Gy in 25 fractions) from September 2010 to December 2013, and opted for the IMRT technique. Before starting radiotherapy a six-clamp thermoplastic Orfit cast was prepared for immobilization of the pelvic region in all the patients and then contrast enhanced computed tomographic (CT) scan of pelvis was done and 3 mm slice thickness scans were acquired and transferred to the treatment planning system (TPS) (Eclipse version 8.9). The gross tumour volume (GTV), CTV, PTV, and organs at risk (OAR) such as rectum, bladder, and femoral heads were delineated on the CT images following the guidelines of the International Commission on Radiation Units and Measurements report number 83 (ICRU 83). [4] Then IMRT plans were created with 6 Mega Volt (MV) and 15 MV photon beam and a Varian leaf motion calculator (version 8.9.08), was utilized to calculate leaf motion for dynamic dose delivery. Dose-volume optimizer was used for plan optimization. Anisotropic analytical algorithm was used to calculate doses with grid size of 0.25 cm. After approving, the plans were scheduled for 25 fractions with daily imaging by On Board Imaging system and CBCT technique. Patients were positioned and immobilized with the orfit cast on couch and then CBCT was done with the OBI system. The anatomy matching software Portal Vision 7.5, was used to study the patient s setup deviations and to determine the spatial coordinates in the images. After patient setup and laser alignment during EBRT, a kv portal image was taken and matched with the reference image to avoid patient s setup error and a CBCT scan was performed once at the start of treatment and then weekly until the completion of treatment. This CBCT was matched with the reference CT image to see the shift of the uterus, which was noted in X, Y, and Z axes [Figures 1 and 2]. A total of 96 scans were obtained during the whole treatment period, ie, four scans for each patient. Then the patients were assessed for intracavitory brachytherapy and if they did not fit, they Figure 2: The soft tissue matching of the contoured uterus with the reference scan showing bone displacement after radiotherapy were continued for boost by EBRT. Patients were asked to maintain a strict bowel and bladder filling protocol by instructing all the patients to defecate and urinate and then to maintain strict water intake of around 200 ml of water 20 min before the procedure. The position of the uterus was defined in the CTV during delineation on axial images of the lesion for radical radiotherapy. The CTV included all the gross as well microscopic lesions. The OARs such as the bladder, rectum, intestines, andfemoral heads were also delineated on axial images. The position of the uterus was then compared in the following weekly scans on the axial images guided by sagittal, coronal and three-dimensional reconstructions. This was done by merging the weekly CT images with the reference CT image taken before the start of the treatment at the same level. For every scan, we used the lower level of the S1 vertebra. After merging the images, a preliminary bone to bone matching was done to negate the effect of patient s setup errors which was followed by soft tissue matching of the uterus in two CT images. The change in CTV position during the bone to bone matching was subtracted from the anteroposterior (AP), superoinferior (SI), and lateral changes during the soft tissue matching. The correlation between the position of uterus with the position and the filling of the bladder was also assessed. This change in uterus position was measured separately in the AP, SI and lateral directions. No additional effort on the part of the patient or the doctor was required because a part of the OBI software performed the measurements during 140 Journal of Cancer Metastasis and Treatment Volume 2 April 15, 2016

the treatment. The time taken for every treatment was also similar among the patients undergoing IGRT of the pelvic region. The Mean of all the obtained-values for each patient was calculated and an unpaired-one-sample student t-test was applied to obtain the significance. The P value is less than 0.001 which is highly significant. RESULTS The mean, standard deviation, and median of uterine motion in each plane were calculated to see its association with the bladder filling and its influence on the displacement of the uterus. As shown in the Table 1, the displacement ranges were significant depending on the patient, although the mean values of the displacement were within 1 cm. The mean values of shift in AP, SI, and lateral directions were respectively 0.67, 0.29, and 0.23 for all the 96 scans done for 24 patients over the period of EBRT [Table 2]. The mean extent of motion in the uterine position on a daily basis for individual patients ranged from -2.28 to +1.3 in AP, -0.56 to +0.71 in SI, and from -0.6 to +0.45 in lateral directions. The mean movement in all the directions was also calculated over the course of the full treatment [Figure 3], and showed more anterior and superior shift that might be due to bladder filling while the lateral deviation, although Figure 3: The mean change of the uterine position in the lateral (X), anteroposterior (Y), and the superoinferior (Z) directions per patient over the whole course of the treatment along with its association with the bladder volume depicted in the area curve Figure 4: Comparison of different means of displacement in different directions between current study and the study of Taylor et al. [11] Table 1: Combined uterine motion in three different dimensions in patients undergoing radiotherapy Dimensions Mean (SD), cm Median, cm Range of motion, cm Lateral (X) 0.23 (0.22) 0.2-0.6 to 0.45 Anteroposterior (Y) 0.67 (0.83) 0.57-2.28 to 1.3 Superoinferior (Z) 0.29 (0.40) 0.245-0.36 to 0.71 present, was minimum. The posterior shift might be due to the rectal filling or presence or absence of gas in the rectum. The mean bladder volume was calculated to be 90.55 ml for all patients, and each patient had an average bladder volume of about 80 ml to 100 ml over the course of their treatment. This was done by maintaining a strict bladder control protocol for each patient. We found that maximum range of motion was observed when the bladder volume exceeded 100 ml as was seen in patient number 4, where a mean maximum shift in AP direction was almost up to -2.8 cm. When it was compared with their mean bladder volume, it was found to be excessive with a mean of almost up to 180 ml during the course of their treatment. DISCUSSION The EBRT with radiation doses of 40 to 50 Gy followed by boost with brachytherapy has been proven to be effective in the local control of cervical and uterine cancers. However, one of the major concerns with this modality of treatment has been acute or chronic small bowel toxicities with advancement in the treatment techniques of radiation therapy, it has been possible to reduce the toxicity to bowel. Nonetheless, it is essential to see that the benefits are not achieved at the cost of decreased local control due to a geometrical miss. [5-7] The CTV for primary cervical cancer treatment comprises the partially mobile uterus and cervix, the less mobile upper vagina, parametrium and pelvic lymph nodes located along the side walls in the pelvis. When treating with a conventional four field box technique, internal motion is less critical as the dose distribution is likely to encompass the central structures within the high dose region even if they move a little. The dose distribution in IMRT has the potential to conform more precisely to the target volume. Therefore, assessment of organ motion has become more important as there can be a geometrical miss during daily treatment. According to the ICRU statement number 62 (ICRU 62) two margin volumes of CTV should be used to create the PTV: the internal margin to account for organ motion, and the setup marginto account for variation in patient position. [8] Huh et al. [9] and Lee et al. [10] have previously reported the changes in the uterus position by comparing two magnetic resonance images taken before and during the period of radiotherapy. They showed that uterus movement and its Journal of Cancer Metastasis and Treatment Volume 2 April 15, 2016 141

Table 2: The mean of movement in all directions and the mean bladder volume for each patient Patient No. Lateral (X), cm Dimensions Anteroposterior (Y), cm Superoinferior (Z), cm Bladder volume, L 1 0.16-0.3-0.06 0.031 2 0.1-0.133 0.1 0.111 3 0.2 1.32-0.24 0.151 4-0.6-2.28 0.16 0.189 5 0.25 1.15 0.55 0.157 6-0.08 1.04-0.4 0.113 7 0.45-0.75-0.225 0.062 8 0.3 1.15-0.05 0.125 9-0.06 0.6-0.12 0.088 10 0.36 0.55-0.2 0.067 11 0.4 0.3-0.15 0.046 12 0.1 0.04-0.36 0.064 13-0.12 0.18 0.56 0.055 14 0.1 0.3 0.71 0.049 15 0.3 0.4 0.4 0.076 16 0.31-1.21-0.35 0.140 17-0.1-0.53 0.21 0.096 18 0.2 0.67 0.6 0.090 19-0.45 0.45-0.34 0.070 20 0.15-0.22-0.56 0.040 21 0.2 0.71 0.43 0.083 22 0.3 0.51 0.25 0.066 23-0.21 0.81 0.16 0.100 24 0.14 0.91-0.22 0.105 Table 3: The comparison of the magnitude of displacements between current study and the study of Taylor et al. [11] Magnitude of displacement, cm Dimensions Mean (SD) Median Range Present study Lateral 0.23 (0.22) 0.2-0.6 to 0.45 Anteroposterior 0.67 (0.83) 0.57-2.28 to 1.3 Superoinferior 0.29 (0.40) 0.24-0.36 to 0.71 Taylor et al. [11] study Lateral 0.08 (0.13) 0.0 0 to 0.5 Anteroposterior 0.7 (0.9) 0.5 0 to 0.48 Superoinferior 0.71 (0.68) 0.5 0 to 0.32 An assessment of interfractional uterine and cervical motion: implications for radiotherapy target volume definition in gynaecological cancer Table 4: Adverse effects of radiotherapy in twenty-four participants Frequency of toxicity, % Grade 1 Grade 2 Dysuria 80 20 Urinary frequency/urgency 90 10 Diarrhea 95 5 positional change were significant, which suggested the importance of accurately determining the target mobility for the conformal treatment. However, in that study, two sets of magnetic resonance images were taken in the supine position without a small bowel displacement system (SBDS) while the patients were treated in prone position with a SBDS placed under the patient s abdomen. We studied the uterine motion once a week during the full course of radiotherapy and every time, we found a significant shift in uterine position in all directions. In our study the mean bladder volume was 90.55 ml and it was shown that major shift occurred if the bladder volume exceeded 100 ml. We expected a mean bladder volume of 80 to 120 ml during IMRT in all our patients and this was corroborated on the weekly CBCT scans. Despite maintaining a standard bladder volume, we saw a uterine shift daily. In a similar study by Taylor et al., [11] in addition to the uterus, the movement of the cervix was assessed to determine the internal margin for radiotherapy. They concluded that an asymmetrical margin with CTV-PTV expansion of the uterus and cervix was needed during the treatment while they emphasized on the need for a strict bladder and rectum filling protocol during treatment. [11] Very few studies have documented the changes in uterine position during the radiotherapy course. An association between bladder filling and uterine movement was reported by Buchali et al. [12] that indicated no major AP change in cervical position. A maximum mean displacement in AP direction was seen in our study. In contrast, the mean displacement in SI direction was also substantial in the study by Taylor et al. [11] [Table 3 and Figure 4]. The difference might be due to strict adherence to the bladder-bowel filling protocol in our study as well as once weekly CBCT instead of two imaging on two consecutive days in their study. There is a definite association between the bladder filling and rectum emptying with uterine cervix movement. In addition, this association has been demonstrated by studies that have assessed the association of the bladder and rectum volume with the displacements of the uterus and the cervix respectively. Moreover, maximum uterine motion at the fundus emphasizes on the need to contribute a variable 142 Journal of Cancer Metastasis and Treatment Volume 2 April 15, 2016

margin around the fundus in the uterine shift. The incidence of early bladder and rectal toxicities amongst all our patients were mild with all of them except two showing Grade 2 cystitis and mild diarrhea. Only one patient had Grade 2 diarrhea which was controlled with conservative measures [Table 4]. Despite maintaining a strict bladder filling and rectal emptying protocol, the interfraction movement in the uterine position during the course of radiotherapy may lead to a miss in target or overtreatment of the rectum, which lead to toxicity. We could not find any study in which uterine shift was observed during the whole course of radiotherapy hence, we were unable to compare the results with other works. In conclusion, interfraction movement of the target organs may lead to overdosing or underdosing of the target or the normal structures during IMRT, hence at least once a week CBCT imaging might be necessary to minimize the geometrical miss of the tumor and deliver the planned doses to the target and normal structures for the best local control with minimum toxicity which is the primary aim of IMRT. This would also aid in the selection of appropriate and adequate planning target margins and provide an asymmetrical PTV conforming to the daily anatomical shift and contour of the patients. We also recommend a tapered CTV to PTV margin especially around the fundus of the uterus as maximum uterine motion is known at the fundus however further studies with larger numbers of patients and exact point localization of the uterus will be required for this purpose. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest. REFERENCES 1. Mundt AJ, Lujan AE, Rotmensch J, Waggoner SE, Yamada SD, Fleming G, Roeske JC. Intensity-modulated whole pelvic radiotherapy in women with gynecologic malignancies. Int J Radiat Oncol Biol Phys 2002;52:1330-7. 2. Portelance L, Chao KS, Grigsby PW, Bennet H, Low D. Intensity modulated radiation therapy (IMRT) reduces small bowel, rectum, and bladder doses in patients with cervical cancer receiving pelvic and paraaortic irradiation. Int J Radiat Oncol Biol Phys 2001;51:261-6. 3. Roeske JC, Lujan A, Rotmensch J, Waggoner SE, Yamada D, Mundt AJ. Intensity-modulated whole pelvic radiation therapy in patients with gynecologic malignancies. Int J Radiat Oncol Biol Phys 2000;48:1613-21. 4. ICRU Report 83. Prescribing, Recording, and Reporting Photon-Beam Intensity-Modulated Radiation Therapy (IMRT). Bethesda, MD: International Commission on Radiation Units and Measurements; 2010. 5. Gerstner N, Wachter S, Knocke TH, Fellner C, Wambersie A, Pötter R. The benefit of Beam s eye view based 3D treatment planning for cervical cancer. Radiother Oncol 1999;51:71-8. 6. Weiss E, Eberlein K, Pradier O, Schmidberger H, Hess CF. The impact of patient positioning on the adequate coverage of the uterus in the primary irradiation of cervical carcinoma: a prospective analysis using magnetic resonance imaging. Radiother Oncol 2002;63:83-7. 7. Thomas L, Chacon B, Kind M, Lasbareilles O, Muyldermans P, Chemin A, Le Treut A, Pigneux J, Kantor G. Magnetic resonance imaging in the treatment planning of radiation therapy in carcinoma of the cervix treated with the four-field pelvic technique. Int J Radiat Oncol Biol Phys 1997;37:827-32. 8. ICRU Report 62. Prescribing, recording and reporting photon beam therapy (supplement to ICRU report 50). Bethesda, MD: International Commission on Radiation Units and Measurements; 1999. 9. Huh SJ, Park W, Han Y. Interfractional variation in position of the uterus during radical radiotherapy for cervical cancer. Radiother Oncol 2004;71:73-9. 10. Lee JE, Han Y, Huh SJ, Park W, Kang MG, Ahn YC, Lim do H. Interfractional variation of uterine position during radical RT: weekly CT evaluation. Gynecol Oncol 2007;104:145-51. 11. Taylor A, Powell ME. An assessment of interfractional uterine and cervical motion: implications for radiotherapy target volume definition in gynaecological cancer. Radiother Oncol 2008;88:250-7. 12. Buchali A, Koswig S, Dinges S, Rosenthal P, Salk J, Lackner G, Böhmer D, Schlenger L, Budach V. Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynaecological cancer. Radiother Oncol 1999;52:29-34. Journal of Cancer Metastasis and Treatment Volume 2 April 15, 2016 143