DETERMINATION OF AR- TIFICIAL SWEETENERS IN LIQUID FOODS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Similar documents
Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Pelagia Research Library

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

ISSN: ; CODEN ECJHAO E-Journal of Chemistry 2011, 8(3),

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

Journal of Chemical and Pharmaceutical Research

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin

Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition

Hyderabad, India. Department of Pharmaceutical Chemistry, Glocal University, Saharanpur, India.

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

Ankit et al Journal of Drug Delivery & Therapeutics; 2013, 3(2), Available online at RESEARCH ARTICLE

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

Development and validation of related substances method for Varenicline and its impurities

Journal of Chemical and Pharmaceutical Research

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

International Journal of Pharma and Bio Sciences

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Development of a Validated RP-HPLC Method for the Analysis of Citicoline Sodium in Pharmaceutical Dosage Form using Internal Standard Method

New RP-HPLC Method for the Determination of Fludarabine in Pharmaceutical Dosage Forms

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Development and validation of RP-HPLC method for simultaneous estimation of gliclazide and metformin in pure and tablet dosage form

Volume 2 (6), 2014, Page CODEN (USA)-IJPRUR, e-issn: International Journal of Pharma Research and Health Sciences

J Pharm Sci Bioscientific Res (4): ISSN NO

Pelagia Research Library

A simple validated RP-HPLC method for quantification of sumatriptan succinate in bulk and pharmaceutical dosage form

Journal of Chemical and Pharmaceutical Research, 2013, 5(1): Research Article

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

ISSN (Print)

Scholars Research Library. Der Pharmacia Lettre, 2016, 8 (6): (

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

DEVELOPMENT AND VALIDATION OF NEW HPLC METHOD FOR THE ESTIMATION OF PALIPERIDONE IN PHARMACEUTICAL DOSAGE FORMS

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Analysis of Commercially Available Products Containing Stevia

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

A Validated Chiral Liquid Chromatographic Method for The Enantiomeric Separation of Dapoxetine Hydrochloride

MEDAK DIST. ANDHRA PRADESH STATE, INDIA. Research Article RECEIVED ON ACCEPTED ON

Scholars Research Library

AMERICAN JOURNAL OF BIOLOGICAL AND PHARMACEUTICAL RESEARCH

Application Note. Authors. Abstract. Food

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2

Corresponding Author:

Amudha S et al., Asian Journal of Pharmthiaceutical Technology & Innovation, 04 (21); 2016; Research Article

Journal of Pharmacreations

Research Article Simultaneous Estimation of DL-Methionine and Pyridoxine Hydrochloride in Tablet Dosage Form by RP-HPLC

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF LACOSAMIDE IN BULK AND ITS PHARMACEUTICAL FORMULATION

Available online at Scholars Research Library

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography


Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

Method Development and Validation for the Estimation of Saroglitazar in Bulk and Pharmaceutical Dosage Form by RP-HPLC

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Determination of taurine in energy drinks by high-performance liquid chromatography

A NOVEL RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF BERBERINE, QUERCETIN, AND PIPERINE IN AN AYURVEDIC FORMULATION

IJRPC 2011, 1(4) Rohan et al. ISSN: INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations

Comparison of conventional HPLC with UPLC method for determination of albuterol sulfate and it s impurities in pharmaceutical formulation

Title Revision n date

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

CHAPTER 3: ANALYTICAL METHOD DEVELOPMENT AND VALIDATION

Rebaudioside a From Multiple Gene Donors Expressed in Yarrowia Lipolytica

A Reverse Phase HPLC Method Development and Validation for the Determination of Paliperidone in Pure and Dosage Forms

Development and validation of UV spectrophotometric estimation of lisinopril dihydrate in bulk and tablet dosage form using area under curve method

SIMULTANEOUS DETERMINATION OF ATORVASTATIN AND EZETIMIBE BY RP-HPLC IN PURE AND PHARMACEUTICAL DOSAGE FORM

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ASSAY AND DISSOLUTION OF METOPROLOL SUCCINATE EXTENDED RELEASE TABLETS

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

438 Full Text Available On

Asian Journal of Research in Chemistry and Pharmaceutical Sciences

Stability indicating RP-HPLC method development and validation of Etizolam and Propranolol hydrochloride in pharmaceutical dosage form

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BACLOFEN IN BULK AND PHARMACEUTICAL DOSAGE FORMS

Journal of Chemical and Pharmaceutical Research

Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides Isolated From Stevia rebaudiana Bertoni

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

International Journal of Medicine and Pharmaceutical Research. International Journal of Medicine and Pharmaceutical Research

A Validated Rp-Hplc Method for the estimation of Milnacipran in Tablet dosage forms

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography

NOVEL RP-HPLC METHOD. B.Lakshmi et a. concentration range KEY INTRODUCTION. Diltiazem is used to. . It works by of contractionn of the. (dilate).

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Development and Validation of RP-HPLC Method for the Simultaneous Estimation of Haloperidol and Trihexyphenidyl in API and Combined Tablet Dosage Form

Transcription:

INTERNATIONAL JOURNAL OF PHARMACEUTICS & DRUG ANALYSIS VOL. 3 ISSUE 10, 2015; 311 321 ; http://ijpda.com; ISSN: 2348-8948 RESEARCH ARTICLE DETERMINATION OF AR- TIFICIAL SWEETENERS IN LIQUID FOODS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY DOUSHI D. RAMSURN, SABINA JHAUMEER- LAU- LOO, MINU G. BHOWON* Department of Chemistry, Faculty of Science, University of Mauritius, Reduit, Mauritius Date Received: 29 th September 2015; Date Accepted: 24 th October 2015 Date published: 26 th October 2015 Email: mbhowon@uom.ac.mu Abstract: Artificial sweeteners are widely used nowadays in order to substitute sugar. The analysis for various foods is very important for food quality control and regulation enforcement. In this study, the presence of five different artificial sweeteners aspartame, acesulfame k, saccharin, sucralose and rebaudioside A were analysed in 38 liquid food items including soft drinks, fruit juices, energy drinks and dairy products using high performance liquid chromatography (HPLC). The sweeteners aspartame, acesulfame k and saccharin were separated on a C18 column and were identified using a diode array detector. Sucralose was analysed using a refractive index detector while a UV detector was used for rebaudioside A. The validation of the analysis methods was determined in terms of sensitivity, linearity range, precision, repeatability, analytical recovery and residual analysis. Out of the thirty eight samples analysed, artificial sweeteners were detected in twenty samples. Therefore it can be concluded that there is a tendency by manufacturers to add mixture of artificial sweeteners in a product. Key words: acesulfame k, aspartame, saccharin, Sucralose, rebaudioside A, HPLC determination INTRODUCTION: Artificial sweeteners are substances which are significantly sweeter than the common carbohydrate sweeteners such as sucrose. Their sweetness range from about 30 times to several thousand times that of sucrose. The use of artificial sweeteners in food industry has been growing rapidly in recent years whereas in the past, they were mainly used in diabetic products. They have gained popularity as substitute sweeteners in many food products especially in soft drinks and other beverages, as consumers tend to control their sugar intake. Artificial sweeteners provide little caloric value to the normal diet and they do not affect insulin or glucose levels. Hence, they may help in weight management and provide sweet-tasting foods for people with diabetes. Examples of commonly used artificial sweeteners are aspartame, acesulfame k, saccharin and sodium cyclamate. However, there had been arguments based on studies [1] which had stated that artificial sweeteners might be hazardous to human health when consumed at certain concentrations. Many experiments have associated cancers with the intake of sweeteners but there was not enough evidence to prove it. Chronic exposure to these artificial sweeteners has been reported to cause the following symptoms; headaches, blurred vision, epileptic fits, brain tumor, insomnia, nausea and memory loss. [2-8] Hence, the use of artificial sweeteners in food has to be regulated by using a reliable, accurate, precise and robust method to monitor the concentration of added sweeteners. A variety of methods [9] such as UV spectroscopy [10], capillary electrophoresis [11], high performance liquid chromatography [12-- 15], high performance thin layer chromatography [16] and ion chromatography [17] have been used to determine the concentration of sweeteners in foods and beverages. The purpose of this study was to determine and quantify 5 different sweeteners namely acesulfame k, aspartame, saccharin, sucralose and rebaudioside A by using HPLC techniques in 38 different liquid foods marketed in Mauritius. The methods used were validated using several parameters such as limit of detection, limit of quantification, calculation of residuals for the standards and the recovery obtained from spiked samples. The results obtained were compared with the Food Regulation 1999 of Mauritius to see whether the concentrations of the st died sweeteners were within the limit set [18]. 311

Materials and Methods Reagents and Materials Reference compounds, acesulfame k, aspartame, saccharin, and rebaudioside A were purchased from Sigma-Aldrich (Steinheim, Germany) and sucralose was from BDH Chemicals LTD (UK). All standards were 98 or greater % purity. HPLC-grade methanol, orthophosphoric acid (85%) and acetonitrile were obtained from Sd-Fine Chem. Limited (Mumbai, Maharashtra). Sodium acetate was purchased from Fisher Chemical (UK) and acetic acid was purchased from Techno pharmchem (India) and was of HPLC grade. Water was purified using a SG instrument Ultra-pure water purification system (Hyde Cheshire). Preparation of standard solutions Stock solutions of a ternary mixture of acesulfame k, aspartame and saccharin (500 ppm), sucralose (300 ppm) and that of rebaudioside A (600 ppm) were prepared by dissolving the reference compounds in distilled water. A series of calibration standard solutions were prepared by diluting stock solutions in a concentration range of 50-500, 50-300 and 100-600 ppm. Dilutions of the standards solutions were done directly in 1.5 ml vials by using an electronic pipettor of range 75 µ L -1000 µ L. Preparation of Samples A set of 38 commercially available liquid foods were purchased from the local markets. The samples consisted of 13 soft drinks, 14 fruits juices, 6 energy drinks and 5 dairy products. The samples were prepared by modified reported procedures. [19] All the samples were first homogenised to ensure uniformity. Samples of soft drinks and energy drinks were degassed for 15 minutes in an ultrasonic bath. For dairy products, 5.0 g of the sample was dissolved in 100 ml of methanol, sonicated for 15 minutes and centrifuged at 4,000 rpm for 10 minutes. The samples were filtered through a 0.45 µm membrane filter before being injected into the HPLC system. If concentration of the sweeteners in samples exceeded the range of the calibration curve, the sample was diluted with distilled water in order for the concentration of the sample to fit in the calibration curve. Selected category of each variety of food samples was spiked with the standards to a concentration of 100 ppm to calculate the percentage recovery of the test analysis. Chromatographic conditions Acesulfame k, saccharin and aspartame were separated using a Dionex HPLC system of model Ultimate 3000 series with an Agilent C18 column (150 x 2.1 mm, 5 µm). The mobile phase was prepared by mixing methanol and the buffer solution (0.681 g of sodium acetate and 3 ml of acetic acid) in a ratio of 1:3. The mobile phase flow rate was set at 0.365 ml/min and injection volume was 2 µl. The column temperature was set at 30 C. The UV wavelength was set to 205 nm for aspartame and 229 nm for acesulfame k and saccharin. Each standard of the sweetener was first run separately to determine the retention time for each analyte. The retention time of acesulfame k was found to be 1.626 minutes, for saccharin 2.592 minutes and 31.017 minutes for aspartame and hence, the total run time was set to 36.00 minutes for each run of mixed standards. For sucralose, the analysis was performed using a Shimadzu HPLC system equipped with a refractive index detector. A Shim-pack VP-ODS C18 column (150 x 4.6 mm, 5 µm) was used. The mobile phase consisted of a mixture of water/ acetonitrile (15:85) and was pumped with the flow rate of 1.00 ml/min with an injection volume of 10 µl. The column temperature was set at 40 C. The retention time of sucralose standard being 7.884 minutes, hence the total run time was thus set to 9.00 minutes. The chromatographic analysis of rebaudioside A was performed on a Shimadzu HPLC system equipped with a UV detector using a Hilic packing column (150 x 5 mm, 4.6 µm). The ph of the mobile phase (water:acetonitrile, 2:3) was adjusted to 3 by adding orthophosphoric acid. Elution flow rate was 0.300 ml/min with an injection volume of 10 µl and compartment column was set to 40 C. Rebaudioside A was eluted at a retention time 7.522 minutes and the total run time was set to 10.00 minutes and the UV wavelength was adjusted to 190 nm. Quantification of each sweetener was performed by measuring peak areas at the corresponding retention time and comparing them with their corresponding calibration curve. Determination of limit of detection (LOD) and quantification (LOQ). The EPA sw-846 protocol was used to determine the lod and loq. a visual evaluation of the lod was determined by the analysis of known concentrations of standards until the minimum level of the analyte can be reliably detected. the minimum quantifiable standard was run 7 times and the standard deviation(s) were calculated. the lod and loq were calculated using the formulae: LOD = T0.99 X S LOQ = 3 X LOD Where, t0.99 is the one-tailed t-statistic at the 99% confidence level for n-1 replicates, n = 7 a n d s is 312

standard deviation of n sample spikes at the estimated LOQ In addition to the calculation method, evaluation of LOD and LOQ was based on signal to noise ratio to confirm the values. The limit of detection was estimated with concentrations giving a signal-to-noise ratio of 3 to 1. Results and discussion Method Development and Optimzation of HPLC system Method validation is a procedure used to confirm that the analytical procedure implemented for a particular test for the quality, reliability and uniformity of analytical results. Accordingly, the sensitivity, linearity range, reproducibility and recovery of the standards were evaluated. The sensitivity of each method was evaluated via the limits of detection and quantification, which were determined according to International Conference for Harmonization (ICH, 1990). The precision of our method was evaluated as analytical repeatability based on three replications of the standard solutions and calibration curves were plotted from the standard drug concentrations versus peak areas of the individual drugs. Precision is expressed as the relative standard deviation (RSD) of the replicates. Table 1 summarizes the different validation parameters used during the analytical tests. The linearity of each standard was tested within the amount range which covers the most likely amounts injected in the column for real sample analysis. The correlation coefficients, r 2 for all the sweeteners were higher than 0.99, which revealed a good linearity in the concentration range for each sweetener. The LOD was estimated with concentration giving a signal-to-noise ratio of 3 to 1. The LOQ for saccharin was the lowest whereas that of sucralose was the highest. Hence, the analysis performance for saccharin had the best sensitivity. The % RSD values for all methods were less than 10% which confirmed the repeatability of the analysis. [20] The accuracy of the analytical method was evaluated using the recovery test. Selected samples (J10, S9, D1, E2) were spiked with 100 ppm standards and were treated as normal samples. The developed method resulted in satisfactory recoveries for the samples, ranging from 96.5 % to 103.5%. This revealed the reliability of the method (Table 2). Residuals of standards Figure 1 shows the residual plot for each sweetener standard with the residuals on the vertical axis and concentration on the horizontal axis. A residual is the vertical difference between the Y value of an individual and the regression line at the value of X corresponding to that individual, for regressing Y on X and identifies non-linearity or outliers. In general, a null linear residual plot shows that there are no observable defects in the model, a curved plot indicates non-linearity and a fan-shaped or double-bow pattern indicates non-constant variance [21]. If the residual points are randomly dispersed around the horizontal axis, the linear regression model is appropriate for the data which indicate a good fit for a linear model. [22] From Table 3 and Figure 1, the residuals are spread uniformly and are at random around the regression lines, passing the normality distribution test (p<0.05). The standard error for each sweetener is very small (except for rebaudioside A) and hence it can be concluded that all the regression models are good ones Application of the developed method to real samples The proposed methods for the five sweeteners were applied for the analysis of the 38 liquid samples. The presence of acesulfame k, saccharin and aspartame sweeteners in the samples were determined by comparing both the retention time and spectral data generated by the diode array detector at wavelength 205 nm and 229 nm of standards with that of the samples peaks. For sucralose and rebaudioside A analysis, presence of the sweeteners in samples were determined by overlaying the chromatogram of the standards with that of the samples; that is based on retention time. Quantification of the sweeteners was based on peak areas. Table 4 summarized the average concentration of the sweeteners in the analysed samples obtained on HPLC with their standard deviation. Table 1: Validation parameters of the analytical tests Parameter Acesulfame k Saccharin Aspartame Sucralose Rebaudioside A Linearity range (ppm) 0-500 0-500 0-500 0-300 0-600 2 r 0.9999 0.9999 0.9995 0.9994 0.9995 LOD (ppm) 0.104 0.0486 1.59 2.20 0.24 LOQ (ppm) 0.312 0.146 4.77 6.99 0.718 RSD % 1.45 0.99 0.56 3.00 9.96 313

Sample Table 2: Recovery of spiking samples % Recovery Acesulfame k Saccharin Aspartame Sucralose Rebaudioside A J10 98.99 99.47 99.20 99.88 103.5 S9 98.49 97.97 99.04 99.21 102.4 D1 97.33 96.51 98.95 98.46 101.9 E2 99.58 99.13 99.51 99.84 101.1 Table 3: Summary output of the standards Acesulfame k Saccharin Aspartame Sucralose Rebaudioside A residuals -0.502 0.487-0.062 0.217 0.061 0.640-0.260 1.770-7.24 5.80 Standard error 0.392 0.159 0.388 0.720 6.51 p-value < 0.05 < 0.05 < 0.05 < 0.05 < 0.05 314

Table 4: Concentration of Sweeteners in food samples Sample Acesulfame k/ ppm Saccharin/ ppm Aspartame/ ppm Sucralose Rebaudioside A J1 - - 15.03± 1.10-232.70± 0.86 J2 2.93± 0.06 14.95± 0.02 - - - J3 2950± 89 - - - - J4-9.46± 0.41 - - 16.13± 0.71 J5 422.20± 0.65-844.00 ± 0.42 - - J6 165.60± 0.75 - - 96.46± - J7-145.20± 0.14 - - - J8 - - - - - J9 73.52± 0.12-1336± 37 - - J10 - - - - - J11 - - - - - J12 - - - - - J13 - - - - J14 - - - 69.32± - E1 - - - - - E2 - - - - - E3 - - - - - E4 163± 1-74.68± 1.25 - - E5 22.46± 1.60 - - 218.30± - E6 - - - - - S1 136.70± 2.76 60.23± 1.47 - - - S2 - - - - 142.90± 0.08 S3 - - - - - S4 - - - - - S5 61.11± 1.09 - - - - S6 197.00± 0.06 - - - - S7 82.20± 0.55-377.50± - - S8 - - - - - S9 - - - - - S10 190.20± 16.75-318.80± - - S11 - - - - - S12 - - - - 144.90± 1.39 S13 - - - - - D1 - - - - - D2 - - - - - D3 17.61± 0.46 - - - - D4 - - - - - D5 24.54± 0.08-24.13± 0.45 - - 315

Figure 1: Chromatograms of different standards 316

S1 J3 S7 D3 E5 317

S10 E4 J7 J1 E4 318

D3 E5 S2 319

S12 Figure 2: Chromatograms of selected samples Application of the developed method to real samples The proposed methods for the five sweeteners were applied for the analysis of the 38 liquid samples. The presence of acesulfame k, saccharin and aspartame sweeteners in the samples were determined by comparing both the retention time and spectral data generated by the diode array detector at wavelength 205 nm and 229 nm of standards with that of the samples peaks. For sucralose and rebaudioside A analysis, presence of the sweeteners in samples were determined by overlaying the chromatogram of the standards with that of the samples; that is based on retention time. Quantification of the sweeteners was based on peak areas. Table 4 summarized the average concentration of the sweeteners in the analysed samples obtained on HPLC with their standard deviation. From the 38 samples analysed, artificial sweeteners were detected in 20 samples. Most samples in which sweeteners had been detected had stated to have artificial sweeteners in their ingredient lists except the juices J1 and J4. In J1, aspartame (15 ppm) and rebaudioside A (233 ppm) were detected and in J4 juice, saccharin (9 ppm) and rebaudioside A (16 ppm) were detected. In both juices, the manufacture only labeled no sugar added but did not mention the sweeteners that were added. Moreover, most of the samples that contained sweeteners did not label the amount of sweeteners added except J3 (acesulfame k-100mg/serving) and J5 (aspartame-0.32g/l, acesulfame k-0.03g/l). For the juices J3 and J5, the amounts of sweeteners detected were beyond that stated. This is because both juices were concentrated and needed to be diluted before consumption and the data reported herein is for the concentrated juice. None of the samples analysed exceeded the maximum limits set by Food Regulation 1999. However, it should be noted that the Food Regulation 1999 only specified the concentration of aspartame and saccharin that should be added in liquid foods but no limit were specified for acesulfame k, sucralose and rebaudioside A. CONCLUSION Increased use of artificial sweeteners in food and beverages can present a danger to health if their concentrations exceed the acceptable daily intake. Hence, it is important to control the amount of artificial sweeteners added in food by regulating their concentration in food and beverages through legislation in order to prevent excessive intake. Sensitive, reliable and robust analytical methods to determine and quantify sweeteners are essential to meet the needs of growing markets in quality control and consumer safety. Consequently, it is important to develop analytical methods for simple, rapid and low-cost sensitive determination of sweeteners. The HPLC methods used are simple, rapid, require minimum sample preparation with high sensitivity and robustness. Hence, the method can be used routinely for regulation inspection of these different sweeteners in liquid food. References 1. Kroger M, Meister K, Kava R., Low-calorie Sweeteners and Other Sugar Substitutes: A Review of the Safety Issues. Compr Rev Food Sci F. 2006; 5: 35-47. 2. Humphries P, Pretorius E, Naude H., Direct and indirect cellular effects of aspartame on the brain. Eur. J. Clin. Nutr. 2008; 62: 451-462. 3. Swithers, S.E., Artificial sweeteners produce the counterintuitive effect of inducing metabolic derangements. Trends Endocrin. Met. 2013; 24(9): 431 441. 4. Gail K, John B, Endlich B, Martha S., Evidence on 320

the carcinogenicity of sodium saccharin. Reproductive and Cancer Hazard Assessment Section Office of Environmental Health Hazard Assessment California Environmental Protection Agency, 2003; 1-66. 5. Weihrauch M.R, Diehl V., Artificial sweeteners do they bear a carcinogenic risk? Ann. Oncol. 2004; 15(10): 1460-1465. 6. Whitehouse C.R, Boullata J, Mccauley L., The Potential Toxicity of Artificial Sweeteners, AAOHN Journal, 2008; 56(6): 251-259. 7. Rodero A.B, Rodero L de S, Azoubel R., Toxicity of Sucralose in Humans. Int. J. Morphol. 2009; 27(1): 239-244. 8. Nikoleli G.P, Alexandros G.A, Asimakopoulos G, Dimitrios P.N., Methods of Analysis of Acesulfame-K and Aspartame, Handbook of Analysis of Active Compounds in Functional Foods, 2009; 847-854. 9. Zygler A, Wasik A, Namieśnik J., Analytical methodologies for determination of artificial sweeteners in foodstuffs. Trends Analyt. Chem. 2009; 28(9): 1082 1102. 10. Turak F, Ozgar M.U., Validated Spectrophotometric Methods for Simultaneous Determination of Food Colorants and Sweeteners, Journal of Chemistry. 2013, 1-9. 11. Stojkovic M, Mai T.D, Hauser P.C., Determination of artificial sweeteners by capillary electrophoresis with contactless conductivity detection optimized by hydrodynamic pumping. Anal Chim Acta. 2013; 787: 254-259. 12. Serdar M, Knežević Z., Determination of artificial sweeteners in beverages and special nutritional products using high performance liquid chromatography. Arh Hig Rada Toksikol. 2011; 62: 169-173. 13. Croitoru M.D, Fülöp I, Ajtay M.K, Balogh C, Dogaru M.T., Direct HPLC-UV determination of cyclamate, saccharine and aspartame from soft drinks. Acta Alimentaria. 2011; 40(4): 459-465. 14. Idris M, Varshney K.M, Sudhakar P, Shuklaand S.K, Baggi T.R., HPLC determination of aspartame in tabletop sweeteners by precolumn derivatization using dinitrofluorobenzene. Int J Pharm Pharm Sci. 2012; 4(1): 522-527. 15. Chang C-S, Yeh T.S., Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry. J Food Drug Anal. 2014; 22: 318-323. 16. Saifi M, Ali A, Saini M, Nasrullah N, Khan S, Abdin M.Z., A rapid and efficient high performance thin layer chromatographic (hptlc) method for simultaneous analysissci. of stevioside and rebaudioside A in stevia rebaudiana. Int. J. Pharm. Pharm. Sci. 2014; 6(5): 465-469. 17. Chen Q-C, Wang J., Simultaneous determination of artificial sweeteners, preservatives, caffeine, theobromine and theophylline in food and pharmaceutical preparations by ion chromatography, J. Chromatogr. A. 2001; 937: 57-64. Regulations made by the Minister under Section 18, Food Act 1998, Government Notice No. 173 of 1999, 273-275. 18. Geana E-I, Iordache A-M, Ionete R.E., Simultaneous determination of artificial sweeteners in possible counterfeited wines, using high performance liquid chromatography with DAD detection, Ovidius University Annals of Chemistry. 2012; 23(1): 77-81. 19. McDevitt V.L, Rodríguez A, Williams K.R., Analysis of Soft Drinks: UV Spectrophotometry, Liquid Chromatography and Capillary Electrophoresis. J. Chem. Educ. 1998; 75(5): 625-629. 20. Montgomery D.C, Peck E.A., Introduction to Linear regression analysis 2nd edition. John Wiley. New York. (1992) 21. McPolin O., Validation of analytical methods for pharmaceutical analysis, Warrenpoint: Mourne Training Services, 2009. 321