Comparison of PAL SPME Fibers with established Fibers

Similar documents
Restek PAL SPME Fibers cat.#

HT5 - High Temperature Stationary Phase for Capillary Gas Chromatography

Table 1 Fuel Oil UST Closure Soil Analytical Results St. Ann Center for Intergenerational Care Sigma Project No

Locating DNAPLs at Former MGP Site

The challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample

using the Agilent 7696A Sample Prep

Volatile Organic Compounds (VOCs)

Separation of 54 PAHs on an Agilent J&W Select PAH GC Column

Volatile Organic Reference Materials for U.S. EPA Method 8260

Not authorized translation of original document

VCP ASSESSMENT ACTIVITIES CONDUCTED IN NOVEMBER 2018

Revised 2/7/01 PATUXENT WATER FILTRATION PLANT TAP WATER ANALYSIS 2000

Fast Separation of EU and US EPA Regulated PAHs on Agilent J&W Select PAH GC Columns

TOPIC: Gradient Analysis of PAH's using an Alliance System

Optimized Volatile Organic Compound Analysis Using Agilent VOC Application Solution

Rapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph

Catalog No. : Lot No. : Container Size : 300 µl Autosampler Vial Pkg Amt : 150 µl

Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column

Idaho Bureau of Laboratories 2220 Old Penitentiary Road Boise, Idaho Phone: (208) Fax: (208)

WA VPH Standard. Catalog # Lot # A

CERTIFICATE OF ANALYSIS

Increasing Extraction Efficiency of Wet Samples Using a Novel New Polymer During Accelerated Solvent Extraction

Blood Alcohol Determination with Teledyne Tekmar HT3 Automated Static/Dynamic Headspace Analyzer Application Note Introduction

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION ROSS AVENUE, SUITE 1200 DALLAS, TX December 7, 2018

Automated Analysis and Quantitation of Fish Oil Supplements using the MIDI Sherlock Marine Oil Analysis Package

AS Application Note 1602

A Ameren Champaign

Analysis of Organic Acids and Alcohols Using the Agilent J&W DB-624UI Ultra Inert GC Column

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

Chromatography Vacuum Ultraviolet Spectroscopy

Table 2-1. Soil Sampling Summary

Contract: Wilton Processing Site. Contract No: D6267. Client: York Potash Ltd Title: PID Results Page 5 TEL: FAX:

ABERDEEN HARBOUR EXPANSION PROJECT November Volume 3: Technical Appendices MONITORING DATA

IDENTIFICATION AND CONTROLOFRESIDUALSOLVENTS Identification and control of residual solvents EUROPEAN PHARMACOPOEIA 6.

Quantitative Determination of Terpenes in Cannabis Using Headspace Solid Phase Microextraction and GC/MS

EPA TO-15 QC Criteria

Rxi -5Sil MS Columns

July 9, Freeman Avenue Telephone: (562) Signal Hill, California Facsimile: (562)

DEVELOPMENT AND VALIDATION OF THE GC METHOD FOR THE QUANTITATIVE DETERMINATION OF SEMI-VOLATILE SOLVENTS IN THE PHARMACEUTICAL SUBSTANCE BOSENTAN

Quantitation of Four Regulated Phthalates in Plastic Consumer Products by Gas Chromatography Time-of-Flight Mass Spectrometry

Test Report. Report No.RLSZE Page 1 of 17

Roc On with These Dependable LC Columns

The next level of True Blue Performance

Life Science and Chemical Analysis Centre. John Heim

Analyze Drugs of Abuse with Agilent J&W Ultimate Plus Tubing in an Inert Flow Path

AppNote 1/2005. Blood Alcohol Analysis Using an Automated Static Headspace Method ABSTRACT

Polycyclic Aromatic Hydrocarbon (PAH) Standards and Standard Mixtures

Subject: Point of Entry Treatment System Sampling Results May 14, 2013 Sampling Event 1 Meadow Spring Drive, Bel Air, Maryland

OC2017 A-035- Unrestricted. Report. Oil spill identification. OSINET Round Robin Author(s) Kjersti Almås Marianne Unaas Rønsberg

Quantitative Analysis of -Hydroxybutyrate in Hair Using Target Analyte Finding Processing of Comprehensive GC-HRT Data

3-Acetyldeoxynivalenol. 15-Acetyldeoxynivalenol

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

Column Selection for the Analysis of Fatty Acid Methyl Esters Application

Off-flavour Analysis in Food Using a Simple and Rapid SPME-GC/TQMS Method with Dedicated Off-flavour Database

CONTEST. Scheme Description. Contaminated Land Proficiency Testing Scheme

Forensic Analysis of Blood Alcohol Concentration

APPENDIX D HAZARDS SCREENING LEVEL HEALTH RISK ASSESSMENT MEMORANDUM

Interested in conducting your own webinar?

Improved Characterization of Perfumes with GC GC-TOFMS

DEVELOPMENT AND VALIDATION OF GAS CHROMATOGRAPHY METHODS FOR THE CONTROL OF VOLATILE IMPURITIES IN THE PHARMACEUTICAL SUBSTANCE DUTASTERIDE

Analysis of FAMEs Using Cold EI GC/MS for Enhanced Molecular Ion Selectivity

Choosing Preparative Columns

Test Report. Report No.RLSZE Page 1 of 16

AppNote 4/2002. Stir Bar Sorptive Extraction: Capacity and Competition Effects KEYWORDS ABSTRACT. SBSE, SPME, capacity

WTQA '99-15th Annual Waste Testing & Quality Assurance Symposium LESSONS LEARNED FROM PERFORMANCE EVALUATION STUDIES

HAZARDOUS WASTE MANAGEMENT POST-CLOSURE CARE PERMIT ATTACHMENT 1 APPENDIX I ANNUAL GROUNDWATER SAMPLING CONSTITUENT LIST (APPENDIX IX 40 CFR PART 264)

1 000 ml 50% CAS: ml Ref : F Price : DB

Report Groundwater Analysis Results 86 th Quarter Event

Metabolomics Strategies

Pyrogenic vs Petrogenic Source Determination: Diagnostic PAH ratios. Gordon Nelson Andrew Garrard

Rapid Separation of Fatty Acid Methyl Esters

Organophosphorus Pesticides Analysis Using an Agilent J&W DB-5ms Ultra Inert Capillary GC Column. Application Note. Environmental. Abstract.

Martin Lommatzsch Gottfried-Hagener-Str. 60 D Köln. Report

2009 REASONABLE POTENTIAL ANALYSIS SUMMARY THE BOEING COMPANY SANTA SUSANA FIELD LABORATORY NPDES PERMIT CA

Separation of 37 Fatty Acid Methyl Esters Utilizing a High-Efficiency 10 m Capillary GC Column with Optimization in Three Carrier Gases

#20 Separation of Alcohols Using Gas Chromatography

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Direct Thermal Extraction Analysis of Food Packaging Material

Analysis of several common. organic acids in tobacco leaf, snus, and moist snuff

Testing Results of Water Samples from an Informal Pond

DEPARTMENT OF THE ARMY US ARMY CENTER FOR HEALTH PROMOTION AND PREVENTIVE MEDICINE 5158 BLACKHAWK ROAD ABERDEEN PROVING GROUND MD

GREYS LANDFILL 2009 GROUNDWATER MONITORING REPORT

Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Table H3-1 Values Used for Daily Intake/Absorbed Dose Inhalation of Particulates

SCOPE OF ACCREDITATION TO ISO/IEC GUIDE 34:2009. ERA Table Mountain Parkway Golden, CO Mr. David Kilhefner Phone:

Polycyclic Aromatic Compound (PAC) Standards and Standard Mixtures

TABLE 1A. RESULTS OF CHEMICAL ANALYSIS OF SITE WATER AND ELUTRIATE Kill Van Kull Western End SITE WATER ELUTRIATE CONSTITUENTS DETECTION LIMITS CONCEN

HYDROXYPROPYLCELLULOSE, LOW SUBSTITUTED Stage 4, Revision 1 CP: USP BRIEFING NOTE

Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds

Isopropanol (2-propanol) 49.5% CAS: Toluene 50% CAS: Water, ion-free 0.5% CAS:

Determination of SCCP and MCCP in different matrices by use of GC-ECNI-MS-combined Method_V8final_

State of Alaska DEPARTMENT OF ENVIRONMENTAL CONSERVATION DIVISION OF SPILL PREVENTION AND RESPONSE CONTAMINATED SITES PROGRAM

Highly Reproducible Detailed cis/trans FAMEs Analysis Ensured by New Optimized Rt-2560 Column Manufacturing and Application-Specific QC Test

AppNote 3/2013. Automated Determination of Total Fat, Saturated Fat, Monounsaturated Fat and Trans Fat Content in Food Samples KEYWORDS ABSTRACT

Exceed the Requirements of Standard Environmental Methods using a High Performance GC-TOFMS. Jonathan D. Byer

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

Results of Using Re-washed Vials and Closures

GAS CHROMATOGRAPHY-MASS SPECTROMETRY/SOLID PHASE MICROEXTRACTION: A NEW TECHNIQUE FOR THE IDENTIFICATION OF MVOCS FROM MOLDY BUILDING MATERIALS

Transcription:

Comparison of PAL SPME Fibers with established Fibers Abstract The performance of SPME fibers is an essential aspect of an analytical method. This study shows the comparison of three different SPME fibers of a conventional brand (referred to in the following as Brand X ) and the new PAL SPME Fibers. The tests involve the EPA Method 831 for PAH standards using three dedicated Brand X fibers, and the PAL SPME Fibers PDMS 7 µm, PDMS 3 µm, and Acrylate 85 µm. Furthermore the EPA Method 52.2 was tested for a mixture of 64 VOCs (Mega Mix 52.2) using two dedicated Brand X fibers, and the PAL SPME Fibers PDMS 1 µm and Carbon WR 95 µm. The new PAL fibers (PDMS fibers 7 µm, 3 µm, and 1 µm and the Acrylate fibers) yield identical results when compared with the corresponding Brand X fibers. For medium and high boiling compounds the PAL Carbon WR Fibers show a significantly better performance than the respective Brand X fibers. For more information visit: www.palsystem.com Printed 2/214 PAL is a registered trademark of CTC Analytics AG, Switzerland

Performance of different SPME Fibers for PAH-Samples (EPA Method 831) 7 µm PDMS Fiber Column: 1 ml Water + PAH Standard (2 ng/compound) (EPA Method 831, PAH Mixture) 3 min Immersion at 4 C, Agitating at 25 rpm 1 min. at 25 C in SPI Liner Directly Connected to the Column Inertcap 5MS/Sil (GL-Science) 15 m x.25 mm ID, Film Thickness.25 µm Temp. Progr. GC Oven: 9 C hold 1 min, 5 C/min up to 32 C Chromatographic Comparison Measurements with the PAL 7 µm PDMS fiber were compared to the corresponding Brand X fiber. For each type of fiber a series of 12 analytical runs were performed. Figure 1 shows the overlay of a chromatogram from the PAL 7 µm PDMS Fiber (blue), and a corresponding Brand X fiber (red). 1 Naphthalene 2 Acenaphthylene 3 Acenaphthene 4 Fluorene 5 Phenanthrene 6 Anthracene 7 Fluoranthene 8 Pyrene 9 Benzo(a)anthracene 1 Chrysene 11 Benzo(a)pyrene Figure 1: Chromatographic Comparison of PAL Fiber PDMS 7 µm (blue) and Brand X Fiber (red). 2 Comparison of PAL SPME Fibers with coventional Fibers

Quantitative Comparison The diagram shows the signal areas of three analytical runs for five selected target molecules with the same fiber compared to the corresponding Brand X fiber. No significant difference between the Brand X and the PAL PDMS 7 µm fibers is observable. The two brands of fibers show identical results. 7 μm PDMS Fibers 2 15 1 5 Brand X Lot 57291 Figure 2: Quantitative Comparison of PAL 7 µm PDMS Fiber and Brand X Fiber for Five selected Target Molecules. 3 µm PDMS Fiber Column: 1 ml Water + PAH Standard (2 ng/compound) (EPA Method 831, PAH Mixture) 3 min Immersion at 4 C, Agitating at 25 rpm 1 min. at 25 C in SPI Liner Directly Connected to the Column Inertcap 5MS/Sil (GL-Science) 15 m x.25 mm ID, Film Thickness.25 µm Temp. Progr. GC Oven: 9 C hold 1 min, 5 C/min up to 32 C Quantitative Comparison The diagram shows the signal areas of three analytical runs for five selected target molecules with the same fiber compared to the corresponding Brand X fiber. No significant difference between the Brand X and the PAL PDMS 3 µm fibers is observable. The two brands of fibers show identical results. 25 2 15 1 5 3 μm PDMS Fibers Brand X Lot 3151 Figure 3: Quantitative Comparison of PAL 3 µm PDMS Fiber and Brand X Fiber for Five selected Target Molecules. Comparison of PAL SPME Fibers with coventional Fibers 3

85 µm Acrylate Fiber Column: 1 ml Water + PAH Standard (2 ng/compound) (EPA Method 831, PAH Mixture) 3 min Immersion at 4 C, Agitating at 25 rpm 1 min. at 25 C in SPI Liner Directly Connected to the Column Inertcap 5MS/Sil (GL-Science) 15 m x.25 mm ID, Film Thickness.25 µm Temp. Progr. GC Oven: 9 C hold 1 min, 5 C/min up to 32 C Quantitative Comparison The diagram shows the signal areas of three analytical runs for five selected target molecules with the same fiber compared to the corresponding Brand X fiber. No significant difference between the Brand X and the PAL PDMS 85 µm fibers is observable. The two brands of fibers show identical results. 14 12 1 8 6 4 2 Acrylate Fibers Brand X Lot 32978 Figure 4: Quantitative Comparison of PAL 85 µm Acrylate Fiber and Brand X Fiber for Five selected Target Molecules. 4 Comparison of PAL SPME Fibers with coventional Fibers

Performance of different SPME Fibers for VOC-Samples (EPA Method 52.2) 1 µm PDMS Fiber 1 ml Water + 3 g NaCl + 52.2 MegaMix (2 ng/compound) (EPA Method 52.2 MegaMix Mixture Restek PNo 3431) 15 min Equilibration Time in Headspace at 5 C, Agitating at 25 rpm 1 min at 25 C in SPI Liner directly connected to the Column Column: BGB-624; 3 m x.32 mm, Film Thickness 1.8 µm Temp. Progr. GC Oven: 5 C hold 1 min; Afterwards 5 C/min up to 22 C Quantitative Comparison The diagram shows the signal areas of three analytical runs for six selected target molecules using PDMS 1 µm fibers. No significant difference between the Brand X and the PAL fibers is observable. 1 8 6 4 2 1 μm PDMS Fibers Brand X Lot 3266 Figure 5: Quantitative Comparison of PAL 1 µm PDMS Fiber and Brand X Fiber for Six selected Target Molecules. Comparison of PAL SPME Fibers with coventional Fibers 5

95 µm Carbon WR 1 ml Water + 3g NaCl + 52.2 MegaMix (2 ng/compound) (EPA Method 52.2 MegaMix Mixture Restek PNo 3431) 15 min Equilibration Time in Headspace at 5 C, Agitating at 25 rpm 1 min 25 C in SPI Liner directly connected to the Column Column: BGB-624; 3 m x.32 mm ID, Film Thickness 1.8 µm Temp. Progr. GC Oven: 5 C hold 1 min; Afterwards 5 C/min up to 22 C Chromatographic Comparison Measurements with the PAL 95 µm Carbon WR fiber were compared to the corresponding Brand X fiber. For each type of fiber a series of 12 analytical runs was performed. Figure 1 shows the overlay of a chromatogram from a PAL 95 µm Carbon WR Fiber (blue), and a Brand X Carboxen fiber (red). 1 1,1-Dichloroethene 2 cis-1,2-dichloroethene 3 Benzene 4 Trichloroethylene 5 Toluene 6 Ethylbenzene 7 m-,p- Xylene 8 o-xylene 9 Bromobenzene 1 2-Chlorotoluene 11 1,3,5-Trimethylbenzene 12 4 Chlorotoluene 13 tert-butylbenzene 14 1,2,4-Trimethylbenzene 15 sec-butylbenzene 16 n-butylbenzene 17 1,2,4-Trichlorobenzene 18 Naphthalene 19 1,2,3-Trichlorobenzene Figure 6: Chromatographic Comparison of PAL 95 µm Carbon WR Fiber (blue) and Brand X Carboxen fiber (red). 6 Comparison of PAL SPME Fibers with coventional Fibers

Quantitative Comparison The diagram shows the signal areas of three analytical runs for six selected target molecules with the same fiber compared to the Brand X fiber. The Brand X Carboxen and the PAL Carbon WR fibers show similar results for low boiling compounds. However, signal areas of higher boiling-point compounds such as Naphthalene show significantly higher performance with the PAL Carbon WR fibers (Figure 7). 8 6 4 2 95 μm Carbon WR / Carboxen Fibers Brand X CX Figure 7: Quantitative Comparison of PAL 95 µm Carbon WR Fiber and Brand X Fiber for Six selected Target Molecules. Fiber to Fiber Reproducibility 3 µm PDMS Fiber 1 min Immersion at 25 C Carrier Gas: 7.5 ml Water + Performance Mix (Nitrobenzene,2-Nitrotoluene 1 µg, each in 1 µl Methanol) in 1 ml Vial 1 min 28 C in SPME Liner.8 mm ID Hydrogen 7 kpa Column: ZB-5 15 m x.25 mm ID, Film Thickness.25 µm Temp. Progr. GC Oven: 4 C hold 1 min; Afterwards 5 C/min up to 8 C GC-FID: Thermo Trace 2, with FID at 25 C Performance Test In order to ensure consistent quality of the fibers, tests according to the performance test of a well-established brand were performed. The absolute values obtained are of minor importance for the analyst, as quantification of SPME analysis always requires an internal standard method. Nevertheless, those values are interesting for fiber production, as any change in the performance e.g. variations of the film thickness or changes of the physical properties of the phase can be detected. The diagram shows the peak areas for two selected molecules obtained from eight different fibers (3 µm PDMS) that had been subjected to the SPME performance test. Comparison of PAL SPME Fibers with coventional Fibers 7

Figure 8: Fiber to Fiber Reproducibility Test. Parameters of PAL SPME Fibers Coating Film Thickness (µm) Operating Temperature ( C) Maximum Temperatur ( C) Hub Color Code PDMS 7 2-34 34 Green FIB-P-7/1 PDMS 3 2-28 28 Gold FIB-P-3/1 PDMS 1 2-28 28 Red FIB-P-1/1 Polyacrylate 85 2-28 3 Grey FIB-A-85/1 Carbon WR 95 22-3 3 blue FIB-CWR-95/1 P/N Compatibility PAL SPME Fibers are compatible with all holders currently in use for automated applications. Conclusion The new PAL fibers (PDMS fibers 7 µm, 3 µm, and 1 µm and the Acrylate fibers) yield identical results when compared with the corresponding Brand X fibers. For medium and high boiling compounds the PAL Carbon WR Fibers show a significantly better performance than the respective Brand X fibers. The reproducibility of the fiber production is very high. Nevertheless the use of an internal standard for quantification is recommended, as it is common practice for quantitative SPME. Data Sheet A detailed data sheet is provided with informations on (pre-) conditioning, operating temperatures and cleaning in order to gain full performance and an extended lifespan of PAL SPME Fibers. 8 Comparison of PAL SPME Fibers with coventional Fibers