Health and Safety Policy Arrangements: Radiation Protection Guidelines

Similar documents
The checklist for the use of Ionising Radiation in Primary Dental Care. Not fully compliant

Information and Guidance

IRMER Ionising Radiation Medical Exposure Regulations

IONISING RADIATION REGULATIONS 99

Trust Policy 218 Ionising Radiation Safety Policy

SUMMARY AND EXTRACTS FROM THE 2010 GUIDANCE ON THE SAFE USE OF DENTAL CONE BEAM CT (COMPUTED TOMOGRAPHY) EQUIPMENT

Ionising Radiation Policy

Appendix I. List of stakeholders consulted with on the Patient Radiation Protection Manual and members of the Medical Exposure Radiation Unit

Code of Practice for Radiation Protection in Dentistry. Code of Practice For Radiation Protection in Dentistry

Ionising Radiations Regulations 2017

On successful completion of the Unit the learner will be able to:

IONISING RADIATION POLICY (for the Safe Use of)

Ionising Radiation Policy

RADIATION SAFETY POLICY. Controlled Document Number: Version Number: 3 Controlled Document Sponsor: Controlled Document Lead: Approved By:

Questions for ionising radiation applications

making a referral for breast imaging Standard Operating Procedure

DIRECT ACCESS - Guidance to BSDHT Members

SFHOH4 SQA Unit Code H4PX 04 Contribute to the production of dental images

Step by Step Guidance on how to Conduct a Clinical Audit in. Dental Radiography Core Subject

Ionising Radiation Safety Type: Policy Register No: Status: Public. For compliance with the Ionising Radiations Regulations 1999

The Professional Relationships Associated with the Practice of Dental Therapy Practice Standard

BRITISH SOCIETY OF DENTAL AND MAXILLOFACIAL RADIOLOGY CORE CURRICULA IN DENTAL RADIOGRAPHY AND RADIOLOGY FOR THE DENTAL TEAM

Procedure. Identify all possible radiation hazards.

Primary Care Dental Services Clinical Governance Framework. May 2006 (Updated)

Guided learning hours It is recommended that 15 hours should be allocated for this unit, although patterns of delivery are likely to vary.

The Royal College of Radiologists, August 2000 This Publication is Copyright under the Berne Convention and the International Copyright Convention.

Ionising Radiation Policy

Template Standard Operating Procedure For: Handling of Midazolam and other controlled drugs in Dental Practices

IT and Information Acceptable Use Policy

Management of AIDS/HIV Infected Healthcare Workers Policy

Higher National Unit specification: general information

CERTIFICATE IN SPECIAL CARE DENTAL NURSING

CERTIFICATE IN ORTHODONTIC NURSING

WORKERS IN A NUCLEAR FACILITY

1. NHS (GENERAL DENTAL SERVICES) (SCOTLAND) AMENDMENT REGULATIONS AMENDMENT NO 136 TO THE STATEMENT OF DENTAL REMUNERATION

Performers List Validation by Experience (PLVE)

General Dental Practice Inspection (Announced) Parkway Cosmetic and Dental Spa (Private Dental Practice) Inspection date: 25 July 2016

FOR CHILDREN ATTENDING FOR EXODONTIA UNDER GENERAL ANAESTHETIC

Workplace Drug and Alcohol Policy

INDEX Pages. 1. Conditions which are normally included in all determinations of conditional registration Alleged health issues...

DIRECT ACCESS Guidance to BSDHT Members

THE IONISING RADIATIONS REGULATIONS 1999

Protecting Vulnerable Groups Guidance for Care Inspectorate staff and service providers Publication date: October 2012

Approval of Dosimetry Services in Ireland Guidelines for Applicants

Volunteers Code Of Conduct

Information about cases being considered by the Case Examiners

Translation and Interpretation Policy

Specialist List in Special Care Dentistry

Ward/Unit/Team managers to carry out an occupational skin disease risk assessment for their area

Drug and Alcohol Policy

RADIATION PROTECTION SERVICE DEPARTMENT OF WELLBEING, SAFETY AND HEALTH

Managing Noise at Work Safety Guidance Document

Health & Safety, Edinburgh Napier University

Darwin Marine Supply Base HSEQ Quality Management Plan

The Radiation Health and Safety Act, 1985

NANDTB-F012 Rev 0 Audit Checklist

CERTIFICATION OF PERSONNEL IN RADIATION SAFETY AND PROTECTION

STATE OF IDAHO BOARD OF DENTISTRY

Developed By Name Signature Date

COURSE: Dental Radiography

IONISING RADIATIONS REGULATIONS 2017 REGULATIONS 5, 6, AND 7. NOTIFICATION, REGISTRATION AND CONSENT

Essential CPD for the dental team

A Study of dose Distribution and Radiation Protection in Industrial Radiography in Ireland

Document Control Report

RADIOLOGIST JOB DESCRIPTION. Head of Radiology Department Radiology Manager

RECERTIFICATION PROGRAMME FOR CONTINUING PROFESSIONAL DEVELOPMENT OF OPTOMETRISTS

Application form for an Annual Practising Certificate 2017/2018 Application form for updating Practising Status 2017/2018 (Annual Renewal)

BMA INFORMATION BULLETIN No. 23. International Safety Management (ISM) Code

Workplace Drug and Alcohol Policy

Smoke Free Policy. Printed copies must not be considered the definitive version. Policy Group. Author Version no 3.0

The College of Dental Surgeons of Saskatchewan Radiation and Imaging Standard

Alcohol, Tobacco and Other Drugs Minimum Standard. April 2015

Requirements for the Childcare Register: childminders and home childcarers

RECERTIFICATION PROGRAMME FOR CONTINUING PROFESSIONAL DEVELOPMENT OF OPTOMETRISTS

Day care and childminding: Guidance to the National Standards

Radiation Safety Procedures for the Use of Sources of Ionising Radiation. Trinity College, Dublin.

Cutanea Life Sciences, Inc. Comprehensive Compliance Program

PATIENT GROUP DIRECTION PROCEDURE

SECTION 1 - INTRODUCTION 2 PURPOSE 2 SCOPE 2 DEFINITIONS 2 LEGISLATIVE CONTEXT 3 RESPONSIBILITIES 4

An overview of Patient Group Directions (PGDs)

Acutely Painful testes

Government Notices 2016

No Smoking Policy. No Smoking Policy

RADIATION MANAGEMENT PLAN EXPLANATORY NOTE

LOCAL EQUALITY ADVISORY FORUM (LEAF) A Staffordshire CCGs Equality & Inclusion Group. Terms of Reference

A Guide to IR(ME)R for Referrers

DTSS Practice Inspections

Qualification Specification. Gateway Qualifications Level 3 Award in Supporting Children and Young People with Autism

SAFE HANDLING OF VACCINES

Here4me Action for Children PROTOCOL FOR THE PROVISION OF ADVOCACY for West Berkshire

Application form for an Annual Practising Certificate 2018/2019 Application form for updating Practising Status 2018/2019 (Annual Renewal)

Occupational Health and Safety Act, 1993

Prohibited Carcinogens, Restricted Carcinogens and Restricted Hazardous Chemicals Procedure

SPECIALTY TRAINEE IN ORTHODONTICS GLASGOW DENTAL HOSPITAL AND SCHOOL AND INVERCLYDE ROYAL HOSPITAL, GREENOCK

Higher National Unit Specification. General information for centres. Visceral and Dynamic Imaging. Unit code: DW93 34

Online Form. Welcome to the Integrated Research Application System. IRAS Project Filter

icat Precise Policy and Procedure Manual

Smoke Free Policy. Version 2.0

HEALTH & SAFETY MANAGEMENT LICENCE SCHEDULES

BCC DENTAL HYGIENE DEPARTMENT PATIENT S RIGHTS AND CONSENT PACKET STANDARDS OF PATIENT CARE PATIENT S RIGHTS FOR DH CARE

Transcription:

Health and Safety Policy Arrangements: Radiation Protection Guidelines Author: Dr N. Sarrami Date of Approval: 12//2010 Due Review Date: 12//2012 1

Radiation Protection Guidelines CONTENTS Section Section Title Page Cover 1 Contents 2 Part 1 - Management of Exposure to Radiation 1.1 Introduction and Statement of Intent 3 1.2 Aims and Objectives of this Guidance 3 1.3 Scope and Equality Impact Assessment Statement 3 2.0 Notification of the Mangement 3 3.0 Legal Responsibility and Staff Appointments 4 4.0 Written Rules and Procedures 5 5.0 Exposure and Dose Controls 5 6.0 Equipment 6 7.0 Training and CPD 6 Part 2 - Employer's Procedures for Medical Exposures Dental X-Ray 1.0 Identification of individual to be exposed 2.0 Duty Holders 3.0 Medico-Legal Exposures 4.0 Quality Assurance Programmes 5.0 Assessment of patient dose Diagnostic 6.0 reference levels 7.0 Evaluation and recording of exposure.0 Reduction of accidental and unintended doses 9.0 Training 10.0 Incident reporting 7 7 9 9 9 2

Part 1 - Management of Exposure to Radiation 1.1 Introduction and Statement of Intent Sunny Smiles Dental Care is responsible for the implementation of the Ionising Radiations Regulations 1999 (IRR99) which relates principally to the protection of workers and the public and the Ionising Radiation (Medical Exposure) Regulations 2000 (IR(ME)R2000) which impose new requirements for patient protection. Full guidance is contained in the NRPB's Guidance for Dental Practitioners on the Safe Use of X-ray Equipment, published by the Department of Health in June 2001. It is the policy of our dental practice to take all reasonable steps to ensure that any dose of ionising radiation received by staff and members of the public whilst on premises is as low as reasonably practicable and kept below acceptable dose limits. 1.2 Aims and Objectives of this Guidance This guidance and procedures document has been developed to: a) b) 1.3 To control the risks of working with x-ray equipment; To ensure, so far as is reasonably practicable, the health, safety and welfare of staff who work with x-ray equipment and patients who are being exposed to x-rays Scope and Equality Impact Assessment Statement This procedure document has been assessed for equality impact. The procedure is applicable to every member of staff within the practice irrespective of their race, ethnic origin, nationality, gender, culture, religion or belief, sexual orientation, age or disability. This document is to be available to all employees working with x-ray equipment at all times. Managers must ensure that staff have read and are aware of the content of this policy document. All new members of staff joining the Community Dental Service who are likely to work with x-ray equipment should be asked to read this Policy as part of their basic induction. 2.0 Notification of the Management The mangers must be notified of routine use of dental x-ray equipment and of any changes in equipment or location.

3.0 Legal Responsibility and Staff Appointments The legal responsibility for ensuring that the radiation regulations are implemented lie with Sunny Smiles Dental Care. To comply with the regulations a Radiation Protection Adviser and Radiation Protection Supervisor will be appointed and used by our dental practice. Corporate and Individual Responsibility for Health and Safety is set out in the Health and Safety. As well as the duties set out in that document, the following individuals have specific duties of care relating to the safe use of radiological examination equipment Radiation Protection Adviser (RPA) The RPA will provide advice in relation to IRR99 including risk assessment, contingency plans, staff training and the Quality Assurance programme. The person or organisation that provides routine radiation surveys of the dental equipment is normally expected to act as the RPA. Radiation Protection Supervisor (RPS) The RPS will hold responsibility for supervising the work with radiation and ensuring that it is done in accordance with the local rules. In addition all dental surgeons have been suitably trained to carry out the function of the RPS and can act as Referrers, Practitioners and Operators as described in the regulations. All have undertaken the IR(ME)2000 Core of Knowledge, Dental Radiography course and will undertake updating and retraining as advised by the RPA. Operator The Operator (IR(ME)R2000) is any person who is entitled to carry out all or part of the practical aspects associated with dental x-rays. All dentists act as Operators. In addition, within the regulations, Dental Nurses can perform some of the functions of the Operator but must be adequately trained to undertake them. Within our dental practice, the duties of dental nurses as Operators will be restricted to the following under the supervision of the RPS. Patient identification Pressing the exposure button Processing films Labelling and mounting of films Storage of films

4.0 Written Rules and Procedures A Radiation Protection File will contain a copy of the local rules and written procedures for working instructions, contingency arrangements, dose investigation level, patient identification, staff appointments and accidental and/or unintended dose. Risk Assessment (IRR99) should be carried out regularly. A Quality Assurance programme will be in place to ensure consistently adequate diagnostic information. 5.0 Exposure and Dose Controls A Controlled area must be designated for each x-ray set in consultation with the RPA. staff dose levels will be regularly monitored. A level of no higher than 1mSv per year is recommended. The staff are currently not monitored as the audit in previous years has identified that too few radiographs are taken to produce a significant enough dosage and risk to require constant monitoring. A member of staff who is pregnant will be advised to reduce her involvement with dental x-rays to relieve any individual anxiety. It is recommended that the dose level should be less than 1mSv for the declared term of the pregnancy. The taking of dental x-rays must be justified at all times and doses for patients kept as low as reasonably practicable. Clinical audit will be carried out from time to time as deemed necessary. Last radiographic audit was run in 200.

6.0 Equipment An inventory of equipment will be kept up to date and available. Maintenance and associated checks of X-ray equipment will be in accordance with the advice of the manufacturer, supplier and the RPA, particularly with regard to safety and warning features. Critical examination and acceptance test reports (IRR99) These must be obtained for new or significantly modified equipment. The acceptance test should include measurements to assess representative patient doses. 7.0 Training and CPD Appropriate information, instruction and training must be provided for all persons directly associated with dental radiology. Training will be provided to ensure that all dentists and dental nurses have updated knowledge and the skills required for their practice of dental radiology. Continuing Professional Development (CPD) (IR(ME)R2000) Dentists should devote at least twelve and a half hours to radiology and radiation protection within their five yearly recertification cycle. A formal radiation courses are regularly provided locally. Dental nurses should devote at least five hours to radiology and radiation protection within their five yearly recertification cycle.

Part 2 - Employer's Procedures for Medical Exposures Dental X-Ray These procedures are intended to meet the requirements of the Ionising Radiation (Medical Exposure) Regulations 2000, usually known as IRMER. These procedures are binding on the duty holders unless it is indicated otherwise. Where appropriate, reference is made to Regulations and Schedules in IRMER. These procedures are to be followed by the Staff and as presented, relate to dental radiology only. 1.0 Identification of individual to be exposed. The identification process is the responsibility of the operator undertaking the x-ray: For Patients, the identity of the patient must be checked before exposure to ionising radiation. Children and patients with language or learning difficulties or other sensory impairment must be identified by other corroborative evidence, e.g. by asking an accompanying parent or escort. 2.0 Duty Holders Referrers are dental practitioners who are entitled to refer individuals for dental exposures to another practitioner or designated health care professional. For radiography within the practice, the referrer will usually be the dentist seeing the patient. Occasionally a dentist may refer a patient externally for a radiographic examination. In these cases the referral must - Uniquely identify the patient - Contain sufficient clinical information to enable the exposure to be justified - contain a signature identifying the referrer. Practitioners are registered dental practitioners who are entitled to take responsibility for an individual exposure. - All dentists have been adequately trained to act as practitioners. Operators are those to whom any practical aspects of the exposure have been allocated. - All dentists may act as Operators. - In addition dental nurses may perform some of the functions of the Operator as described in the Radiation Protection Policy.

3.0 Medico-Legal Exposures Referrals for medico-legal exposures will only be accepted by our practice from registered dental practitioners. 4.0 Quality Assurance Programmes Within the practice the following records will be kept and will be audited. - Lists of practitioners - List of operators - Authorisation of referrals - Records of medico-legal, screening procedures Records to enable estimation of patient dose and to demonstrate reference levels are not being consistently exceeded. - Training records for practitioners and operators - Equipment inventory - Clinical evaluation of medical exposure - Exposure protocols - Incident reports 5.0 Assessment of patient dose The following information will be recorded in the patient's record. - As the X-ray setting are preset on the X-ray machines dosage will be monitored and recorded by the type of selection chosen by the operator and these must be recorded in patient records. 6.0 Diagnostic reference levels DRLs are not applicable to exposures of patients taking place for medical research purposes. As there is no current research involving the taking of X- rays being undertaken by the practice, DRLs are applicable to all exposures. DRLs are dose levels for typical examinations for groups of standard sized patients or standard phantoms. The DRL should not be consistently exceeded for standard procedures when good and normal practice regarding diagnostic and technical performance is applied. - For Sunny Smiles, the RPA will formally assess the typical patient dose every two years and comparison made with diagnostic reference levels where they are available. 7.0 Evaluation and recording of exposure For diagnostic procedures, the practitioner is responsible for ensuring that a clinical evaluation of the outcome of the exposure, takes place.

- The dentist must record the type of x-ray taken, the quality of the radiograph and the clinical findings on the patient's record card..0 Reduction of accidental and unintended doses. All practical aspects of dental exposures shall be conducted with due regard to minimising unintended doses to patients. The following practises will be observed: - Written protocols will be available for all surgeries and type of equipment in use. - Patients, staff and escorts will be properly instructed in their roles before the x-ray is taken - The field size will be limited to that necessary for the examination and film holders will be used where appropriate. 9.0 Training All dentists and dental nurses will undergo appropriate training and will follow CPD. Training records will be kept and updated annually. 10. Incident reporting - When a member of staff has reason to believe that a person has been exposed to a greater dose of ionising radiation than was intended, an incident form must be completed and the manager informed. - The Manager will notify the RPA who together will carry out an immediate preliminary investigation. - Unless the investigation shows beyond all reasonable doubt that no overexposure took place, the DOH inspector shall be informed immediately and our managers will initiate a detailed investigation.