M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

Similar documents
3D Dosimetry with Polymer Gel

Unrivaled, End-to-End

An anthropomorphic head phantom with a BANG polymer gel insert for dosimetric evaluation of IMRT treatment delivery

Dosimetric characteristics of intensity-modulated radiation therapy and RapidArc therapy using a 3D N-isopropylacrylamide gel dosimeter

Y FILMS DOSIMETR Nederland België / Belgique

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

EORTC Member Facility Questionnaire

Comparison of Energy Dependence of PAGAT Polymer Gel Dosimeter with Electron and Photon Beams using Magnetic Resonance Imaging

The use of the BANG-3 polymer gel to quantify the three-dimensional dose distribution of IMRT

A feasibility study of multislice X-ray CT imaging of gel dosimeters using the zero scan method

The Development of Normoxic Polymer Gel Dosimetry using High Resolution MRI

ph fax

Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry J. Phys.: Conf. Ser.

Optimization of the T2 parametric image map calculation in MRI polymer gel dosimetry

Verification of micro-beam irradiation

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Radiochromic 3D Detectors

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

X-ray computed tomography imaging of polymer gel dosimeters

3-D dose verification by cone-beam optical CT scanning of PRESAGE dosimeter

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Clinical Applications of Gel Dosimeters

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

Comparison of Percentage Depth Dose (PDD) and Post Time Dependence of PAGAT Polymer Gel Dosimeter with Electron and Photon Beams Using MRI Technique

Three Dimensional Dosimetry. Session Program: Therapy Education Session Organizer: L. John Schreiner

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

Evaluation of the basic properties of the BANGkit gel dosimeter

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by:

Dosimetric Analysis Report

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

3D DOSIMETRY IN END-TO-END DOSIMETRY QA

Radiosurgery by Leksell gamma knife. Josef Novotny, Na Homolce Hospital, Prague

ROPES eye plaque dosimetry: commissioning and verification of an ophthalmic brachytherapy treatment planning system

GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3

Specific Aspects of Radiochromic Film Dosimetry AAPM Task Group 235 An Update to Task Group 55 (1998)

Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

RadioTherapy. 80 wt% 90 wt% 3wt% 5wt% 3 wt% 10 wt% 1

The Accuracy of 3-D Inhomogeneity Photon Algorithms in Commercial Treatment Planning Systems using a Heterogeneous Lung Phantom

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

A practical three-dimensional dosimetry system for radiation therapy

Radiochromic film dosimetry in water phantoms

Advanced Applications of 3D Dosimetry and 3D Printing in Radiation Therapy. Devin Miles 2016 DUKE Master Thesis

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

True 3D chemical dosimetry (gels, plastics): Development and clinical role

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

A. DeWerd. Michael Kissick. Larry. Editors. The Phantoms of Medical. and Health Physics. Devices for Research and Development.

X-Ray Guided Robotic Radiosurgery for Solid Tumors

Limits of Precision and Accuracy of Radiation Delivery Systems

Out-of-field dosimetry in radiotherapy for input to epidemiological studies. Roger Harrison

Learning objectives. What kind of motions? 3D Dosimetry in the Clinic: Motion Interplay Effects in Dynamic Radiotherapy

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

Evaluation of PRESAGE dosimeters for brachytherapy sources and the 3D dosimetry and characterization of the new AgX I seed model

Measurement Guided Dose Reconstruction (MGDR) Transitioning VMAT QA from phantom to patient geometry

Advanced film dosimetry for a UK brachytherapy audit

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Online in vivo dosimetry in conformal radiotherapies with MOSkin detectors

How to scan polymer gels with MRI?

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

A spiral phantom for IMRT and tomotherapy treatment delivery verification

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

IROC Prostate Phantom. Guidelines for Planning and Treating the IROC IMRT Prostate Phantom. Revised March 2014

Introduction. Measurement of Secondary Radiation for Electron and Proton Accelerators. Introduction - Photons. Introduction - Neutrons.

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

Future upcoming technologies and what audit needs to address

Activity report from JCOG physics group

Quality assurance in external radiotherapy

Dosisverifikation mit Delta 4 Discover während der Behandlung

8/3/2016. The EPID Strikes Back! - EPID In-Vivo Dosimetry. EPID Research Number of Publications. Why EPID in-vivo? Detectable errors: patient

A preliminary clinic dosimetry study for synchrotron radiation therapy at SSRF

Radiotherapy Standards Users Meeting, 1 Dec 2008 Abstracts. New calorimeters Simon Duane, NPL

Understanding Radiation Therapy. For Patients and the Public

Small field diode dosimetry

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Assessment of X-ray Computed Tomography Dose in Normoxic Polyacrylamide Gel Dosimetry. Patricia Lynn Baxter. Masters of Science

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Acrylonitrile Butadiene Styrene (ABS) plastic-based low cost tissue equivalent phantom for verification dosimetry in IMRT


Small Field Dosimetry & Radiochromic film

IMRT QA: Point Dose Measurements or 2D Array?

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Diode calibration for dose determination in total body irradiation

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

Quality Assurance in Stereotactic. Radiotherapy. Swedish Cancer Institute Seattle, WA

What Can Go Wrong in Radiation Treatment: Data from the RPC. Geoffrey S. Ibbott, Ph.D. and RPC Staff

Applications in brachytherapy

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

Computed tomography Acceptance testing and dose measurements

Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance

Learning objective. Outline. Acknowledgements. KV CBCT Imaging Part I. R Hammoud AAPM 2008 CE-Therapy (SAM) 1

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Transcription:

Three Dimensional BANG Polymer Gel Dosimeters Marek J. Maryanski MGS Research, Inc. Guilford, CT Educational objectives: Describe the need for high-resolution 3D dosimetry in 3D CRT. Explain the physics and chemistry of gel dosimeters in general, and BANG polymer gels in particular. List the radiological properties of polymer gel dosimeters. Explain how to use gel dosimeters. Review the clinical applications (3D CRT; SRS; IMRT; Brachytherapy, including intravascular). The need for high-resolution 3D dosimetry and QA in CRT Rapid progress in 3D CRT techniques has created an urgent need for 3D methods of dosimetry and quality assurance. Requirements: fast and accurate measurement of dose distributions integrated over time and throughout the entire volume of a phantom, with at least millimeter resolution. Existing conventional dosimetry techniques can be classified as 1D (ion chambers, diodes, TLD's) or 2D (radiochromic film or detector arrays) and therefore do not meet that need. 1

The physics and chemistry of gel dosimeters in general Composition: 1) Gelling agent; 2) Solvent; 3) Active compound; 4) Radiation response modifiers Mechanism: 1) Radiolysis of solvents and solutes; 2) Free radicals, ions, unstable and reactive molecules; 3) Chemical reaction; 4) Quantitative readout (e.g. optical, NMR, ph etc.) Examples: Gels with radiochromic dyes(day and Stein, Nature 166, 146, 19); Fricke (Ferrous Sulfate) gels (Gore et al, Phys. Med. Biol. 29, 1189, 1984) The physics and chemistry of BANG polymer gels Composition: 1) Gelatin; 2) Water; 3) Acrylic monomers; 4) Response modifiers; ) Oxygen removed Mechanism: 1) Radiolysis of water, gelatin and the monomers; 2) Free radicals, in amounts proportional to dose; 3) Free radical chain polymerization, crosslinking and grafting to gelatin; 4) Formation of polymer microparticles, attached to gelatin; ) Number of microparticles proportional to dose; 6) Permanent 3D image of dose distribution forms in the gel. Advantage: no diffusion of polymer in the gel The physics and chemistry of BANG polymer gels Readout: Both the water proton NMR relaxation rates (R1=1/T1 and R2=1/T2) in the gel and the light attenuation coefficient (due to Rayleigh scattering) increase in proportion to the local concentration of polymer particles in the gel. Digitization of the 3D dose distribution cloud in BANG gel is done by MRI or optical CT (OCT) scanning. 2

Optical Computed Tomography (OCT) Our in-house built OCT scanner Radiological properties of BANG gels Muscle tissue equivalent elemental composition and density Adjustable sensitivity and dose range Energy independent dose response Dose rate independence, up to 4cGy/min, for photons and electrons Certain formulations are suitable for HE protons or higher dose rates. Accuracy better than 3% R2 dose response of BANG gels 14 R2 = 3.9 + 2.66 D R^2 =.999 2 12 2 R2 = 4.13 +.7 D R^2 =.999 1 1 8 1 6 1 GY/MIN 4 GY/MIN 6 GY/MIN 14 kvp xrays, cgy/min 662 kev photons, 42cGy/min 4.. 1. 1. 2. DOSE (Gy), 6MV X RAYS 2. 3. 1 1 Dose (Gy) 2 2 BANG-3-3Gy BANG-3-2Gy 3

How to use BANG gels Obtain x-ray CT and/or MRI scans of the BANG gel phantom as required by the RTP system. Generate radiation treatment plan for the phantom. Mount the BANG gel phantom for irradiation and deliver the planned radiation treatment. Irradiate calibration gels to known doses. Obtain MRI or OCT scans of the irradiated BANG gels. Calculate R2 or optical density per cm (OD/cm) maps. Calculate dose maps in the gel. Compare gel data with treatment plan Main advantages of BANG over conventional techniques Measurement of the entire 3D dose distribution with high spatial resolution (.1mm - 2mm pixel) Time saving for the physicist and for the radiation treatment facility Visible image of the dose distribution cloud in addition to quantitative information Clinical Applications: Stereotactic Radiosurgery BANG gel mounted in Leksell frame. Dose distribution cloud is visible in the gel. 4

SRS: single isocenter. MRI-derived axial and sagittal dose maps Axial map. Sagittal map SRS: single isocenter. MRI data. Lateral dose profile across the isocenter. Comparison of BANG gel data with treatment plan. (from Marya nski et al, Med. Phys. 23(), 19 96, pp.699-7) 12 1 8 6 4 2 planned gel data 1 2 3 4 6 Lateral distance (cm) 7 8 SRS: multiple isocenters BANG gel CT/MRI fusion. Fr om Me eks e t al, Int. J. Rad. Onc ol. Biol. Phys. Vol. 43, No., pp.113-1141,1999.

SRS: multiple isocenters Comparison of treatment plan with BANG gel data. Fr om Me eks e t al,int. J. R ad. Oncol. Biol. Phys. Vol. 43, No., pp.113-1141,1999. SRS: Optical CT imaging Five axial dose maps from multi-planar OCT scan From Knisely et al., in: Kondziolka D. (ed): Radiosurgery 1997, Vol. 2. pp.21-26. Rad io surgery. Ba sel-ka rger, 199 8. SRS: Optical CT imaging plan Plan vs. OCT Plan vs. MRI From Knisely et al., in: Kondziolka D. (ed): Radiosurgery 1997, Vol. 2. pp.21-26. Radiosurgery. Basel-Karger, 1998. 6

Brachytherapy 2 planned 1 gel data 1 1 2 3 4 6 7 8 9 1 11 12 Distance (cm) Sagittal dose map: multiple-dwell protocol Transverse dose profile: plan vs. gel comparison (from Maryanski et al, Med. Phys. 23(), 1996, pp.699-7) Intravascular Brachytherapy: Dosimetry requirements Steep dose gradients High spatial resolution (.1mm) required The need for full 3D characterization Routine QA measurement should be fast Intravascular Brachytherapy Using OCT Microimaging OCT reconstructed transverse dose map: Ir-192 seed. From Maryanski et al, Med. Phys. 2(7), A17, 1998 7

Intravascular Brachytherapy Using OCT Microimaging Dose falloff: Ir-192 seed. From Maryanski et al, Med. Phys. 2(7), A17, 1998 Relative Dose (A.U.) 8 7 6 4 3 2 1 Cal cul ate d BANG G el TLD Film 2 4 6 8 1 Distance (mm) IMRT Oldham et al, Phys. Med. Biol. 43() pp. 1113-1132, 1998 Low et al, Med. Phys.26(8),August 1999, in press Summary 3D gel dosimeters are needed for QA of 3D CRT Using BANG gels the entire treatment plan verification can be performed using a single phantom, with high spatial resolution, after minimum irradiation time. Phantoms of various shapes can be made for specific applications BANG gels can be imaged using MRI or OCT 8