ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability

Similar documents
ACE C18-AR Use the Power!

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE Excel UHPLC Columns

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

ACE. Intelligent Solutions for Method Development. Method Development Kits. ACE UHPLC and HPLC Columns. a a

Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design

Agilent Technologies Prep LC Columns

Thermo Scientific Hypersil BDS Columns

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available

Dikma Technologies Inc.

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

UHPLC / HPLC Columns Developed for Mass Spectrometry

Hyper-fast & Super-rugged

ACE ACE. HPLC and UHPLC Columns. Product Catalogue

Analytical and Preparative SFC Columns

Restek Ultra II HPLC Columns

ACE ACE. HPLC and UHPLC Columns. Product Catalog

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Am I getting the very best value from my UHPLC analyses?

Dikma Technologies Inc.

Ultra Columns. also available. ordering note

Gerry Hendrickx Regional Sales Manager Central Europe. Developments in Waters Column Chemistries : BEH Technology

Sepax Technologies, Inc.

Ultra Columns HPLC COLUMNS

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

SeQuant ZIC -HILIC For all who expect more...

Fortis Method Development Options

Comparison of a UPLC Method across Multiple UHPLC Systems

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

SeQuant ZIC -HILIC For all who expect more...

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Roc On with These Dependable LC Columns

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

C30 ISOMERS HAVE MET THEIR MATCH

HICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited

YMC-Triart C18. Multi-layer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology

High-Throughput Separations for QA/QC, LC/MS, LC/MS/MS, Combinatorial Chemistry and Rapid Method Development

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

USP Method Transfer of Ziprasidone HCl from HPLC to UPLC

2012 Waters Corporation 1

Preparative Chromatography Meets UHPLC

Chapter 22: Gas and Liquid Chromatography. Liquid Chromatography: Stationary Phases and Mobile Phases: Normal Phase: Reversed Phase:

11:00 a.m. EST Telephone Number: Chair Person: Tim Spaeder

Core-Shell Technology for Proteins and Peptides

Ultimate Core Performance to Maximize Your Investment

The LC Column Playbook

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

Choosing Preparative Columns

InertSustainBio C18. Rapid Separations of Proteins and Peptides

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

HPLC. Varian Dynamax Preparative HPLC Columns

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

A New Era in SFC Column Technology

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

HPLC Columns. HPLC Accessories HPLC Column Test Mixes Reference Books... HPLC Applications...

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

LC Columns with Liquid Separation Cell Technology

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Reversed-Phase Columns (Other than ODS)

HPLC Products. New 1.9μm Pinnacle DB Small Particle HPLC Columns. 2007/08 Edition. Chromatography Products. hplc columns.

Impurity Profiling of Carbamazepine by HPLC/UV

2D-LC as an Automated Desalting Tool for MSD Analysis

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Prep Columns. and Bulk Media. and Bulk Media

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Purification - Flash Chromatography

The Raptor HILIC-Si Column

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Unequalled durability against water elution. % tr

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

Hypersil BDS and Hypersil Classical HPLC Columns

Normal Phase HPLC Column COSMOSIL SL-II

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

GlycanPac AXR-1 Columns

SUMMARY, CONCLUSION & RECOMMENDATIONS

YMC HILIC Columns for Polar Analytes

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 1290 Infinity II LC

New HPLC Column Options for UHPLC

GlycanPac AXH-1 Columns

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Column Stability and Performance under High Temperature HPLC Conditions

Fat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C18 Bonded Column

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance

Raptor HILIC-Si: Simplify the Switch to HILIC

176 YMC Chiral Columns

Transcription:

ACE C8-AR A C8 bonded phase with unique selectivity Guaranteed reproducibility Exceptional bonded phase stability Hydrophobic and aromatic mixed mode interaction High efficiency µm, µm, µm and 0µm particles for UHPLC and HPLC UHPLC and HPLC Columns

ACE C8-AR a C8 phase with unique selectivity Explore the Advantages of ACE C8-AR Provides alternative selectivity to standard C8 columns additionally recommended for compounds with aromatic functionality Ultra inert, ultra high purity silica, for excellent peak shape and reproducibility Compatible with highly aqueous mobile phases to enable the retention and separation of polar compounds Exceptional bonded phase stability for elevated temperature applications Ultra low bleed phase ensures UV and LC/MS compatibility Available in high throughput column dimensions High efficiency µm, µm, µm and 0µm particles for UHPLC and HPLC Contents Page Alternative Selectivity to Standard C8 Columns........................... Comparison with Leading C8 Columns Water Soluble Vitamins........................................ Aromatic Nitrobenzenes....................................... Sulphur Compounds........................................... Analgesics.................................................... Comparison of Column Inertness...........................................6 High Aqueous Compatibility................................................ Temperature and ph Stability..............................................8 Reproducibility and Scalability..............................................9 Low Bleed for UV and LC/MS Compatibility................................0 ACE Excel UHPLC Columns................................................ Material Characteristics................................................... Ordering Information ACE Excel UHPLC Columns and Accessories..................... ACE HPLC Columns and Accessories............................ ACE Capillary and Nano Columns.............................. ACE Method Development Kits................................ ACE Ultra Inert Base Deactivated HPLC Columns

ACE C8-AR a C8 phase with unique selectivity Why do I need another new C8 phase? The use of an ultra pure, ultra inert silica has many recognised benefits, including improved reproducibility, lifetime and chromatographic performance (particularly with basic molecules). However, since the ultra inert silica surface effectively no longer contributes to the separation, C8 columns manufactured with high purity silicas show near identical selectivity. It is therefore highly likely that a problem separation on one leading brand will not be significantly improved by changing to an alternative manufacturer s equivalent product. For many years, experienced chromatographers have been seeking phases with the proven performance and reproducibility benefits shown by such leading C8 column brands, but which additionally provide the alternative selectivity required for their challenging applications. How is ACE C8-AR different? C8 bonded phases currently dominate the HPLC market, with recent surveys indicating that they are still responsible for 0-60% of all HPLC columns sold. However, in recent years the use of Phenyl bonded phases has grown significantly, due to the alternative selectivity they provide. It is estimated that Phenyl phases now account for 0-% of HPLC column sales, making them the largest sub-category after C8 phases. ACE C8-AR shows alternative selectivity to C8 bonded columns ACE C8,, The ACE C8-AR phase utilises a specially developed ligand combining a C8 chain with integral phenyl functionality, thus combining the benefits of both C8 and Phenyl characteristics into a single phase. Based upon the same ultra inert, ultra pure, ultra reproducible silica platform as ACE C8, the unique ACE C8-AR phase provides an alternative selectivity to C8 columns. ACE C8-AR 0 6 We required a C8 phase that provided different chromatography and improved resolution ACE C8-AR delivered Senior Analyst, Leading Pharmaceutical Company Compounds:) -acetamidophenol ) -aminobenzoic acid ) -hydroxybenzoic acid ) caffeine Column: 0 x.6mm, µm Flow Rate:.00ml/min Temperature: 0 C Detection: UV, 0nm Mobile Phase: A. 0.% v/v formic acid in H O B. 0.% v/v formic acid in MeCN Gradient: T(mins) %B 0 9 When should I use ACE C8-AR? Due to their similar hydrophobic characteristics, ACE C8-AR columns may be used for applications in which standard C8 columns would normally be considered. However, due to its integral phenyl functionality, ACE C8-AR is additionally recommended for separations that involve compounds containing aromatic functionality. As the applications contained within this booklet demonstrate, ACE C8-AR can be used to improve separations that are proving problematic on C8 columns. The unique ACE C8-AR phase provides an alternative selectivity to C8 columns, but remains a valid selection for methods in which C8 bonded columns are specified. In many instances, the same evaluation conditions that prove unsuitable for the C8 column prove suitable for the C8-AR column, avoiding the need for lengthy method redevelopment. ACE Ultra Inert Base Deactivated HPLC Columns

ACE C8-AR a C8 phase with unique selectivity Application # - Water Soluble Vitamins ACE C8 6, Zorbax Eclipse XDB. C8 6 Luna C8() 6, Waters Sunfire. C8 6 Enhanced resolution ACE C8-AR 6 0 6 8 0 6 8 Sample: ) pyridoxine ) p-aminobenzoic acid ) pantothenic acid ) folic acid ) cyanocobalamin 6) d-biotin ) riboflavin Column Dimensions: 0 x.6mm Flow Rate:.0ml/min Mobile Phase: A) 0mM KH PO (ph.8) B) 0mM KH PO (ph.8) in 0:0 v/v MeOH/H O Linear Gradient 0% to 0% B over minutes Temperature: 0 C Detection: UV, 0nm Comparative data may not be representative of all applications. Please see page for acknowledgement of trademarks. This test containing water soluble vitamins illustrates that leading C8 column brands provide similar selectivity. After optimisation of temperature and gradient, an acceptable separation is achieved on the ACE C8, with critical pair, just baseline resolved. To improve method robustness it may be preferable to try and further improve resolution. Since the evaluation conditions are already optimal, we now investigate whether changing to an alternative C8 column brand will improve the separation of our critical pairs (peaks, and,6). This approach is representative of a method development strategy currently performed in many laboratories. As the above results demonstrate, both the Zorbax XDB C8 and Sunfire C8 columns no longer resolve critical pair,, whereas the Luna C8() column shows slightly improved resolution of critical pair, but now critical pair,6 is only partially resolved. However, the unique ACE C8-AR phase provides a completely different retention profile to those obtained with the leading C8 column brands. Resolution of both critical pairs is significantly improved and method robustness is no longer an issue. Indeed, further optimisation of both column dimensions and evaluation conditions (to reduce analysis time) is now possible. ACE Ultra Inert Base Deactivated HPLC Columns

ACE C8-AR a C8 phase with unique selectivity Application # - Aromatic Nitrobenzenes Hydrophobic reference ACE C8 Zorbax Eclipse XDB. C8 Luna C8() Waters Sunfire. C8 ACE C8-AR 0 0 0 0 Sample: ),,-trinitrobenzene ),-dinitrobenzene ) nitrobenzene ) neutral molecule (reference) Mobile Phase: 0:0 v/v MeOH/H O Column Dimensions: 0 x.6mm Flow Rate:.00ml/min Temperature: 0 C Detection: UV, 0nm Comparative data may not be representative of all applications. Please see page for acknowledgement of trademarks. This test containing aromatic nitrobenzene compounds performed under simple isocratic conditions again shows that the leading C8 column brands provide near identical selectivity. The differences in absolute retention (as illustrated by the neutral reference marker) are due to purely hydrophobic effects and related to parent silica characteristics (eg: surface area). As the ACE C8-AR illustrates above, hydrophobic retention with a neutral marker is matched to its C8 equivalent, but selectivity towards aromatic nitrobenzene compounds is significantly enhanced - with increased retention and a complete reversal of elution order. This retention profile is completely different to that obtained with a standard C8 phase, and results from the integral phenyl functionality contained within the ACE C8-AR ligand. ACE Ultra Inert Base Deactivated HPLC Columns

ACE C8-AR a C8 phase with unique selectivity Application # - Sulphur Compounds,, ACE C8,, Zorbax Eclipse XDB. C8, Luna C8(),, Waters Sunfire. C8, Enhanced resolution ACE C8-AR 0 6 8 9 Sample: ) methyl phenyl sulphoxide ) methyl phenyl sulphone ) toluene ) thioanisole Mobile Phase: A) H O B) MeOH T = 0 mins; 0% B; T =.0 mins, 0% B; T = 9.0 mins, 9% B Column Dimensions: 0 x.mm Flow Rate: 0.0ml/min Temperature: C Detection: UV, nm Comparative data may not be representative of all applications. Please see page for acknowledgement of trademarks. This difficult separation of sulphur compounds again shows that the leading C8 column brands provide essentially the same separation, with two pairs of co-eluting peaks obtained. However, the C8-AR column again provides a completely different separation to the leading C8 column brands. The additional aromatic (π-π) interaction provided by the ACE C8-AR column enables both critical pairs, and, to be fully resolved. ACE Ultra Inert Base Deactivated HPLC Columns

ACE C8-AR a C8 phase with unique selectivity Application # - Analgesics Separation,, 8 ACE C8,, 6 0 9 0 6 8 0 8 ACE C8-AR 6 0 9 0 6 8 0 Compounds:) -acetamidophenol ) -aminobenzoic acid ) -hydroxybenzoic acid ) caffeine ) -acetamidophenol 6) - hydroxybenzoic acid ) salicylamide 8) acetanilide 9) phenol 0) acetylsalicylic acid ) benzoic acid ) sorbic acid ) salicylic acid ) phenylacetin ) salicylaldehyde Column Dimensions: 0 x.6mm Flow Rate:.00ml/min Temperature: 0 C Detection: UV, 0nm Mobile Phase: A. 0.% v/v formic acid in H O B. 0.% v/v formic acid in MeCN Gradient: T(mins) %B 0 9 The above application shows the separation of analgesics on an ACE C8 column, with pairs of co-eluting peaks observed. This separation is also consistent with those that can be expected with other leading C8 column brands, which exhibit very similar selectivity due to the same (predominantly hydrophobic) interaction. Based upon the same ultra inert, ultra high purity silica platform as ACE C8, the unique ACE C8-AR phase provides an alternative selectivity which enables resolution of all components, including the critical pairs previously identified. The same evaluation conditions that proved unsuitable for the ACE C8 were found to be suitable for the ACE C8-AR column, avoiding the need for lengthy method redevelopment. ACE Ultra Inert Base Deactivated HPLC Columns

HPLC COLUMNS Comparison Data on Commonly Used C8 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Comparison of Column Efficiency for a Neutral Compound Phases Compared According to Metal Activity Phases Grouped According to Silanol Activity Comparison of Column Efficiency for Basic Compounds Categorization of Phases According to Silanol Activity and Inertness ACE C8-AR a C8 phase with unique selectivity Comparison of Column Inertness Leading µm, small pore C8 column brands 0 x.mm i.d. LC/MS compatible dimensions Basic molecule inertness test Peak efficiency and asymmetry investigation Peak Efficiency Comparison ACE C8-AR ACE C8 Sunfire. C8 HyPurity C8 Zorbax XDB. C8 Zorbax SB. C8 Luna C8() XBridge. C8 Inertsil ODS- XTerra MS. C8 Ascentis Express. C8 Hypersil BDS C8 Spherisorb ODS Symmetry. C8 Hypersil ODS 00,600,00,900 0 6,000,000 8,000,000 0,000 N 0. (pyridine) (plates/m),600,00 0,00 9,00 8,00,00 0,00,00 6,00,00,00 Lower Tailing Higher Tailing ACE C8-AR N 0. (pyr) =,00pl/m Waters XTerra MS. C8 N 0. (pyr) = 8,00pl/m Waters Symmetry. C8 N 0. (pyr) =,600pl/m Column Dimensions: 0 x.mm Sample: ) uracil ) pyridine ) phenol Mobile Phase: 0:60 v/v MeOH/H O Flow Rate: 0.0ml/min Temperature: C Wavelength: nm Comparative data may not be representative of all applications. Please see page for acknowledgement of trademarks. Conclusion: Significant differences in efficiency, peak shape and selectivity are seen when analysing pyridine a small highly basic molecule. Increased tailing and retention are indicative of undesirable secondary interactions between pyridine and silanol groups on the stationary phase surface. These interactions can also result in poor column reproducibility. ACE C8 columns have been previously independently tested and found to be exceptionally efficient and extremely inert. The ACE C8-AR maintains this excellent performance. Si-OH ACE Stationary Phases Virtually Eliminate the Negative Effects of Silanols on UHPLC and HPLC Separations Comparison Guide Guide TO C8 REVERSED P HASE Further inertness test data is contained within the ACE HPLC column catalogue and other ACE literature. Additionally, a Comparison Guide to C8 Columns is also available, detailing material characteristics for over 0 HPLC column brands and comparing performance with a number of test probes. Please contact your local distributor to request your copies. 6 ACE Ultra Inert Base Deactivated HPLC Columns

ACE C8-AR a C8 phase with unique selectivity Compatible with Highly Aqueous Mobile Phases Whilst primarily designed to show alternative selectivity to standard C8 columns, ACE C8-AR is also resistant to retention loss in 00% aqueous mobile phases, and may be used with fast gradients where the requirement for rapid re-equilibration and resistance to retention loss are essential. Maximum Reproducibility under High Aqueous Conditions When separating very polar, water soluble compounds, highly aqueous (>9%) mobile phases are often required to achieve sufficient retention. However, operating a conventional C8 column under such conditions can lead to poor chromatographic reproducibility. Over time, peaks will elute with shorter and shorter retention times and resolution between peaks will deteriorate. This retention loss was originally believed to be due to Phase Collapse, whereby the bonded phase ligands become matted down and thus offer a reduced interaction with the sample. However, more recent studies suggest that Pore De-Wetting is actually occurring. The mobile phase is excluded from the pores under highly aqueous conditions and the retention loss is due to a loss of accessible surface area. The integral phenyl functionality of the ACE C8-AR protects against pore de-wetting and subsequent retention loss, resulting in highly reproducible chromatography even under highly aqueous conditions. Reproducible Chromatography with 00% Aqueous Mobile Phase Relative Retention Factor % 00 80 60 0 0 0 0 8 8 Time (hours) ACE C8-AR Conventional C8 Comparative data may not be representative of all applications. Ultra Inert Silica for Excellent Chromatography Many columns designed for use under high aqueous conditions are compromised by the low purity silica employed and exhibit poor peak shape with polar basic molecules. This results in poor chromatography and ultimately leads to poor column reproducibility. ACE C8-AR columns are manufactured from the same ultra inert, high purity silica as all ACE phases ensuring excellent chromatography and excellent reproducibility are obtained. Leading Competitor Comparison Hydrophilic Bases ACE C8-AR ZORBAX SB-Aq Sample: ) nicotine ) benzylamine ) procainamide ) salbutamol ) phenol Mobile Phase:.:96. MeOH/0mM KH PO (ph.) Dimensions: 0 x.6mm i.d. Flow Rate:.0ml/min, Temperature: 60 C, Wavelength: 0nm Comparative data may not be representative of all applications. Please see page for acknowledgement of trademarks. The Zorbax SB-Aq column shows a dramatic loss of performance for peaks and, whereas the ultra inert ACE C8-AR column maintains excellent peak shape with hydrophilic bases. ACE Ultra Inert Base Deactivated HPLC Columns

ACE C8-AR a C8 phase with unique selectivity Temperature and ph Stability At low ph, column deterioration is caused by hydrolysis of the bonded phase, with a decrease in retention observed. The nature of the bonded phase, the purity of the silica surface and bonding density are all critical parameters. The use of a lower purity silica, a shorter ligand and a lower bonding density are all factors that will contribute to accelerated ligand cleavage and reduced column lifetime. Accelerated Column Stability Study - 80 C at ph.9 00 80 ACE C8 (high purity silica) ACE C8-AR (high purity silica) 60 Zorbax SB-C8 (moderate purity silica) % Initial k' 0 Waters Spherisorb ODS (low purity silica) 0 Conventioanl Phenyl (high purity silica, propyl spacer),000 column volumes 0 0 0 00 0 00 0 Time (hours) Acidic Exposure Conditions: Mobile Phase: :9 MeOH/0.% TFA in H O (ph.9) Flow Rate: 0.0ml/min Temperature: 80 C Column Dimensions: 0 x.mm Comparative data may not be representative of all applications. Please see page for acknowledgement of trademarks. Using conditions designed to accelerate column degradation, the ACE C8-AR phase shows little retention loss, with lifetime equivalent to the highly robust ACE C8 phase. Both phases are manufactured from the same ultra pure silica, and out-last the Zorbax SB C8, a phase previously recognised to provide excellent stability for high temperature and low ph applications. As expected, a C8 bonded column based upon a low purity silica (Waters Spherisorb ODS) shows a greatly reduced lifetime under these accelerated conditions. Of particular note is the result comparing the lifetime of a conventional phenyl column to the ACE C8-AR. Despite the use of an ultra pure silica, the lifetime of the phenyl column is diminished compared with the ACE C8-AR, suggesting that the ACE C8-AR may be suitable for applications in which conventional phenyl columns are seen to exhibit reduced lifetime. 8 ACE Ultra Inert Base Deactivated HPLC Columns

ACE C8-AR a C8 phase with unique selectivity Guaranteed Reproducibility and Fully Scalable Of equal importance to alternative selectivity is excellent reproducibility. Variations between different batches of stationary phase are the most common cause of customer concern. ACE stationary phases virtually eliminate the unpredictable negative effects of silanols on HPLC and UHPLC separations by maintaining a rigid control of the complete manufacturing process and establishing tight specifications for purity, selectivity, retention, efficiency and asymmetry. Therefore, as demonstrated in the figure below absolute batch-to-batch and column-to-column reproducibility are guaranteed for all ACE C8-AR columns. Parent Silica Batch Silane Batch Silica Batch # Silane Batch # Silica Batch # Silane Batch # Silica Batch # Silane Batch # Particle Size Column Diameter ACE C8-AR LC/MS 0 x.mm 0.ml/min ACE C8-AR Analytical 0 x.6mm.00ml/min ACE 0 C8-AR Preparative 0 x.mm.ml/min Column: ACE C8-AR, 0 x.6mm (unless specified otherwise) Sample: ) uracil ) -hydroxybenzoic acid ) acetylsalicylic acid ) benzoic acid ) -hydroxybenzoic acid 6) ethyl paraben Mobile Phase: :6 MeCN/0.%TFA in H O Temperature: C Wavelength: nm Flow.00ml/min (unless specified otherwise) The availability of µm, µm, µm and 0µm particle sizes combined with a range of column dimensions from capillary through to preparative scale ensures that methods can be reproducibly scaled up or down. The chromatograms above demonstrate the excellent reproducibility achieved when silica batch and silane batch are changed, and the reproducible scalability obtained when changing particle size and column diameter. ACE Ultra Inert Base Deactivated HPLC Columns 9

ACE C8-AR a C8 phase with unique selectivity Low Bleed for UV and LC/MS Compatibility Many phases exhibit bleed of the bonded phase, which can be most clearly seen under gradient conditions when baseline stability is affected. Whilst most ultra pure C8 phases would be expected to give low column bleed, careful selection of an alternative selectivity bonded phase is required, to ensure that column bleed does not cause unforeseen problems when analysing at low UV wavelengths or by LC/MS. ACE C8-AR Exhibits Low Column Bleed for UV 60 0 0 mau 80 0 0 ACE C8 6 8 9 <0 mau 60 0 mau 80 0 0 Conventional Phenyl Column 6 8 9 0 0 mau 60 0 ACE C8-AR 0 mau 80 0 0 0 6 8 0 0 9 <0 mau Column Dimensions: 0 x.6mm Flow Rate:.00ml/min Temperature: 60 C Detection: UV, nm Compounds: ) nicotine ) benzylamine ) procainamide ) terbutaline ) salbutamol 6) phenol ) internal standard A 8) internal standard B 9) diphenhydramine 0) nortriptyline Mobile Phase: A. 0mM KH PO in H O (ph.) B. :6 (v/v) 0mM KH PO in H O (ph.) / MeOH Gradient: T(mins) %B 0 0 9 9 6 Comparative data may not be representative of all applications. This example compares the low bleed characteristics of an ultra pure ACE C8 column (top) with the moderate bleed typical of a conventional phenyl column (middle). The ACE C8-AR column (bottom) shows improved bleed levels compared to the phenyl column and offers bleed levels comparable to the ACE C8 column, despite containing an integral phenyl functionality which provides the alternative selectivity. For MS detection, the use of non-c8 phases has traditionally presented additional challenges and in extreme instances, column bleed can swamp the detector signal and mask the analyte of interest. TIC trace and MS spectra comparisons also show that ACE C8-AR columns provide extremely low levels of bleed, comparable to levels from a blank column run (with no column attached) and to bleed levels from leading C8 columns. Other typical bonded phases that might be considered to provide alternative selectivity to C8 columns (i.e. conventional phenyl, polar embedded, PFP and AQ type surface chemistries) would all be expected to show higher levels of bleed. Conclusion: The ACE C8-AR phase combines a low bleed level (typical of leading C8 column brands) with an alternative selectivity, thus providing the analyst with a valuable method development tool. 0 ACE Ultra Inert Base Deactivated HPLC Columns

ACE C8-AR a C8 phase with unique selectivity ACE Excel UHPLC columns ACE Excel UHPLC C8-AR Column Advantages High efficiency µm, µm and µm particles Compatible with all UHPLC and HPLC systems Exceptional reproducibility and column lifetime Fully scalable with other ACE particle sizes Rugged and reliable day-to-day performance Robust up to,000 bar (,000psi) ACE Excel delivers excellent resolution and peak shape Application #0 Pharmaceuticals and Related Compounds by UHPLC ACE C8-AR is available as Excel UHPLC high efficiency µm, µm and µm particle size columns, for demanding UHPLC applications. Selectivity is unchanged from the µm, µm and 0µm ACE HPLC C8-AR columns, making scale-up from UHPLC to HPLC, or vice versa, simple and reproducible. ACE Excel UHPLC C8-AR columns are fully compatible with all commercial UHPLC systems and are stable up to,000 bar (,000psi). The low dead volume dual compatible UHPLC/HPLC Excel column hardware has been optimised to take full advantage of the low dispersion of modern UHPLC instruments. Additionally, all ACE Excel UHPLC columns are manufactured using a proprietary HSC TM (High Stability Column) manufacturing process that results in ultra robust UHPLC columns. To further extend ACE C8-AR column lifetimes at UHPLC column pressures, ACE UHPLC pre-column filters are recommended (see page ). Mobile Phase: A = mm formic acid in H O and B = mm formic acid in MeOH Gradient: to 00% B in minutes. paracetamol. hydrochlorothiazide. methylphenylsulphoxide Flow Rate: 0.6 ml/min. methylphenylsulphone Temperature: 0 C Detection: UV, nm Column Dimensions: 0 x.mm. aspirin 6. phenacetin.,-dinitrobenzene ACE Excel C8 Zorbax Eclipse.8 XDB C8 Waters ACQUITY. BEH C8 8.,,-trimethoxybenzene 9. ethylbenzoate 0. nimesulidee. ibuprofen. indomethacin. mefenamic acid P max = bar P max = 0 bar P max = 8 bar ACE columns have led the way in offering C8 bonded phases with the advantage of extra selectivity. The ACE C8-AR and other ACE extra selectivity phases, such as the C8-PFP, C8-Amide, CN-ES and SuperC8 have proved to be extremely valuable tools for achieving separations that may not be possible with standard C8 bonded phases. These extra selectivity phases are not meant to replace standard C8 bonded phases, but rather complement them and so provide chromatographers with powerful, additional mechanisms of separation that can be used to achieve better overall chromatographic results. The availability of ACE Excel UHPLC columns means that chromatographers can combine the power of bonded phase selectivity with the efficiency and speed of UHPLC, providing chromatographers with more choices to achieve better results. Phenomenex Kinetex. C8 ACE Excel C8-AR P max = 0 bar P max = 6 bar Comparative ative data may not be representative of all applications. Please see p. for acknowledgement of trademarks. The above example highlights that these leading C8 brands provide similar selectivity and fail to fully resolve the components under these conditions, with or more critical pairs non baseline resolved ed in each case. The unique selectivity of the ACE Excel C8-AR phase enables improved separation. ACE Ultra Inert Base Deactivated HPLC Columns

ACE C8-AR a C8 phase with unique selectivity Material Characteristics PHASE FUNCTIONAL GROUP ENDCAPPED PARTICLE PORE SIZE (µm) SIZE (Å) SURFACE AREA (m /g) CARBON LOAD (%) RECOMMENDED ph RANGE USP LISTING ACE C8-AR Proprietary octadecyl with Yes,,, 0 00 00..0-8.0 a L embedded phenyl functionality a For optimum column lifetime, a ph range of -8 is recommended. To increase column lifetime at high ph, organic buffers, low buffer concentrations, high % organic solvent and low temperatures must be considered. Further information is contained within A Guide to HPLC and LC-MS Buffer Selection by John Dolan - please contact your distributor to request your FREE copy or visit. UHPLC and HPLC Column Options ACE C8-AR columns are offered in different hardware formats. ACE Excel UHPLC columns are recommended for more demanding UHPLC applications where high pressures and/or flow rates are typically used. ACE HPLC columns are available in a wider range of dimensions from capillary to preparative scale. Identical column selectivity is achieved with both hardwares. ACE Excel C8-AR UHPLC Columns ACE Excel C8-AR UHPLC columns are available with µm, µm and µm particles, using unique Excel hardware specially optimised to take full advantage of low dispersion modern UHPLC instruments. All ACE Excel UHPLC columns are manufactured using a proprietary HSC (High Stability Column) manufacturing process that results in ultra robust UHPLC columns rated for use at pressures up to,000bar/,000psi. ACE Excel µm C8-AR UHPLC/HPLC Columns (supplied in dual compatible UHPLC/HPLC hardware format with 000bar/000psi pressure limit) COLUMN DIAMETER COLUMN LENGTH 0 mm 0 mm mm 0 mm mm 00 mm mm 0 mm PRE-COLUMN FILTER.mm EXL-09-00U EXL-09-00U EXL-09-0U EXL-09-00U EXL-09-0U EXL-09-00U EXL-09-0U EXL-09-0U EXL-PCF0.0mm EXL-09-00U EXL-09-00U EXL-09-0U EXL-09-00U EXL-09-0U EXL-09-00U EXL-09-0U EXL-09-0U EXL-PCF0.6mm EXL-09-06U EXL-09-06U EXL-09-6U EXL-09-06U EXL-09-6U EXL-09-06U EXL-09-6U EXL-09-6U EXL-PCF0 ACE Excel µm C8-AR UHPLC/HPLC Columns (supplied in dual compatible UHPLC/HPLC hardware format with 000bar/000psi pressure limit) COLUMN DIAMETER COLUMN LENGTH 0 mm 0 mm mm 0 mm mm 00 mm mm 0 mm 0 mm PRE-COLUMN FILTER.mm EXL-9-00U EXL-9-00U EXL-9-0U EXL-9-00U EXL-9-0U EXL-9-00U EXL-9-0U EXL-9-0U EXL-9-0U EXL-PCF0.0mm EXL-9-00U EXL-9-00U EXL-9-0U EXL-9-00U EXL-9-0U EXL-9-00U EXL-9-0U EXL-9-0U EXL-9-0U EXL-PCF0.6mm EXL-9-06U EXL-9-06U EXL-9-6U EXL-9-06U EXL-9-6U EXL-9-06U EXL-9-6U EXL-9-6U EXL-9-6U EXL-PCF0 ACE Excel µm C8-AR UHPLC/HPLC Columns (supplied in dual compatible UHPLC/HPLC hardware format with 000bar/000psi pressure limit) COLUMN DIAMETER COLUMN LENGTH 0 mm 0 mm mm 0 mm mm 00 mm mm 0 mm 0 mm PRE-COLUMN FILTER.mm EXL-9-00U EXL-9-00U EXL-9-0U EXL-9-00U EXL-9-0U EXL-9-00U EXL-9-0U EXL-9-0U EXL-9-0U EXL-PCF0.0mm EXL-9-00U EXL-9-00U EXL-9-0U EXL-9-00U EXL-9-0U EXL-9-00U EXL-9-0U EXL-9-0U EXL-9-0U EXL-PCF0.6mm EXL-9-06U EXL-9-06U EXL-9-6U EXL-9-06U EXL-9-6U EXL-9-06U EXL-9-6U EXL-9-6U EXL-9-6U EXL-PCF0 0/pk. Compatible with all UHPLC column brands and all UHPLC instruments. For inlet connections onto a Waters Acquity system a pre-column filter incorporating the unique Waters Acquity column port profile (p/n EXL-PCF0/ACQ) is alternatively recommended. ACE Pre-column Filters for UHPLC To further extend column lifetimes under UHPLC conditions the use of ACE UHPLC Pre-column filters is recommended. ACE UHPLC Pre-column filters are pressure rated to,000bar (,000psi), can be installed simply in seconds and are compatible with all manufacturers UHPLC instruments and all brands of UHPLC columns. Please contact us for further information. ACE UHPLC Column Connectors ACE UHPLC column connectors are ultra low dispersion and compatible with all brands of UHPLC columns and all manufacturers instruments. They are pressure rated to,00 bar (,000 psi). These connectors are simple to install and are reusable. Please contact us for further information. ACE UHPLC Pre-column Filters (p/n EXL-PCF0, 0 pack and p/n EXL-PCF0/ACQ, 0 pack) ACE UHPLC Column Connector (p/n EXL-CC0, 0 pack) ACE Ultra Inert Base Deactivated HPLC Columns

ACE C8-AR a C8 phase with unique selectivity ACE C8-AR HPLC Columns ACE C8-AR HPLC columns are available with µm, µm and 0µm particles, in a wider range of dimensions than available in the ACE Excel UHPLC column format. For optimum column lifetime, a maximum operating pressure of bar/,000psi is recommended. ACE µm C8-AR HPLC Columns (supplied in HPLC hardware format with bar/000psi pressure limit) COLUMN DIAMETER COLUMN LENGTH 0 mm 0 mm mm 0 mm mm 00 mm mm 0 mm 0 mm GUARD CARTRIDGE.0mm - ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 b ACE-9-00GD.mm ACE-9-00 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 b ACE-9-00GD.0mm ACE-9-00 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 b ACE-9-00GD.0mm - - ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 b ACE-9-00GD.6mm ACE-9-06 ACE-9-06 ACE-9-6 ACE-9-06 ACE-9-6 ACE-9-06 ACE-9-6 ACE-9-6 ACE-9-6 b ACE-9-00GD ACE µm C8-AR HPLC Columns (supplied in HPLC hardware format with bar/000psi pressure limit) COLUMN DIAMETER COLUMN LENGTH 0 mm 0 mm mm 0 mm mm 00 mm mm b Consider operating pressure limitations for maximum column lifetime 0 mm 0 mm GUARD CARTRIDGE.0mm - ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 ACE-9-00GD.mm ACE-9-00 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 ACE-9-00GD.0mm ACE-9-00 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 ACE-9-00GD.0mm - - ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 ACE-9-00GD.6mm ACE-9-06 ACE-9-06 ACE-9-6 ACE-9-06 ACE-9-6 ACE-9-06 ACE-9-6 ACE-9-6 ACE-9-6 ACE-9-00GD.mm - - - ACE-9-008 ACE-9-08 ACE-9-008 ACE-9-08 ACE-9-08 ACE-9-08 ACE-9-00GD 0mm - - - ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 ACE-9-00GD.mm - - - ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 ACE-9-00GD 0mm - - - ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 ACE-9-00GD 6 ACE 0µm C8-AR HPLC Columns (supplied in HPLC hardware format with bar/000psi pressure limit) COLUMN DIAMETER COLUMN LENGTH 0 mm 0 mm mm 0 mm mm 00 mm mm 0 mm 0 mm GUARD CARTRIDGE.6mm ACE-9-06 ACE-9-06 ACE-9-6 ACE-9-06 ACE-9-6 ACE-9-06 ACE-9-6 ACE-9-6 ACE-9-6 ACE-9-00GD.mm - - - ACE-9-008 ACE-9-08 ACE-9-008 ACE-9-08 ACE-9-08 ACE-9-08 ACE-9-00GD 0mm - - - ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 ACE-9-00GD.mm - - - ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 ACE-9-00GD 0mm - - - ACE-9-00 ACE-9-0 ACE-9-00 ACE-9-0 ACE-9-0 ACE-9-0 ACE-9-00GD 6 pack, use with cartridge holder H000 and column coupler C000 When using guards, cartridge holder H000 and column coupler C000 required pack, use with integral microbore cartridge holder H000 (not 0mm column length) pack use with semi-prep cartridge holder H000 and column coupler C000 pack, use with integral analytical cartridge holder H000 (not 0mm column length) 6 pack use with prep cartridge holder H0009 and column coupler C000 ACE C8-AR Capillary and Nano HPLC Columns ACE C8-AR capillary and nano columns are available in 0.mm (00µm), 00µm, 00µm and µm internal diameters with µm and µm particle sizes. Please enquire for further information. ACE Pre-column Filters for HPLC To further extend column lifetimes under HPLC conditions the use of ACE HPLC Pre-column filters is recommended. ACE HPLC Pre-column filters are simple to install and replace, are compatible with all HPLC column brands and systems and offer effective low cost column protection. Contact us for further details. ACE HPLC Column Connectors ACE HPLC column connectors are compatible with all brands of HPLC columns and all manufacturers instruments. Please contact us for further information. ACE UHPLC and HPLC Method Development Kits Method Development kits enable the optimum bonded phase for an application to be identified. ACE columns are available with a range of unique, highly selective phases in µm, µm, µm and 0µm particle sizes. Please enquire for further information. ACE Analytical and Microbore Pre-column Filters (p/n ACE-CS0, 0 pack and p/n ACE-HP0, 0 pack) ACE Fingertight HPLC Column Connector (p/n ACE-CC0, 0 pack) ACE and ACE Excel are trademarks of Advanced Chromatography Technologies Limited. Advanced Chromatography Technologies Limited acknowledges the registered and unregistered trademarks of Sigma-Aldrich Co., Thermo Scientific, Phenomenex Inc., GL Sciences, Waters Corporation, Agilent Technologies and has no affiliation with any of these companies. ACE Ultra Inert Base Deactivated HPLC Columns

Free HPLC Technical Guides and Slide Chart Comparison Guide T O C 8 R E V E R S E D P H A S E H P L C C O L U M N S Comparison Data on Commonly Used C8 Phases Stationary Phase Specifications Phases Compared According to Relative Hydrophobicity Comparison of Column Efficiency for a Neutral Compound Phases Compared According to Metal Activity Phases Grouped According to Silanol Activity Comparison of Column Efficiency for Basic Compounds Categorization of Phases According to Silanol Activity and Inertness To receive your FREE copies of these guides or the HPLC Column slide chart contact your local distributor or email: info@ace-hplc.com ACE products are available through our international network of distributors For further information please contact Authorised Distributor: Hichrom Limited The Markham Centre, Station Road Theale, Reading, Berks, RG PE Tel: 08 90 660 Fax: 08 9 8 Email: sales@hichrom.co.uk www.hichrom.co.uk Advanced Chromatography Technologies, Berry Street, Aberdeen, AB HF, Scotland Tel: + (0) 0 Fax: + (0) 80 info@ace-hplc.com P06-0-09-00-000