PRODUCT CATALOG e e HEALTH
MODEL: OC 5 HEALTH OXYGEN CONCENTRATOR ACCESSORIES FILTER AIR FILTER NASAL CANNULA BUBBLE HUMIDIFIER Oxygen concentrator is a device that generates oxygen with a purity of %90-92 ± 3 by using the enviroment air that comprehends in theratio of %21. Oxygen purification system designed appropriate to the human health. Today, many people ara living with different illnesses, such as, heart, lung and the other respiration deseases. Most of these people have found help from the oxygen treatents that they take at home or hospital. This device will help you to take adaquate oxygen treatment that you need. Using the oxygen without permission of authorized people can be dangerous. Device should be used under the supervision of a licensed physician after reading the instructions manual. SPECIFICATIONS TEKNİK ÖZELLİKLER OXYGEN FLOW RANGE 1~ 5l / min OXYGEN CONCENTRATION % 90 ~%92 ±3 MAXIMUM OUTLET PRESSURE 8 PSI ±1 NOISE LEVEL BELOW 55 dba VOLTAGE AC 230V / 50 Hz CURRENT 1,60 AMP ±%10 OPERATING TEMPERATURE RANGE 10 C ~ 40 C OPERATING HUMIDITY RANGE 10 ~90 % RH WEIGHT 17 kg ELECTRICAL SAFETY TYPE B - CLASS II
ACCESSORIES MEDICINE CUP PIEZO CYRSTAL BACTERIAL FILTER AIR TUBING EXTERNAL GLASS BOTTLE HEATER FLEXIABLE ARM AERESOL CUP NEBTIME ultrasonic nebulizers is a devices which produced to be used in the sick person s therapy by being vapourised of liquids and in solution condition madicines. During the liquid turn into the vapor, frequency uses instead of heating technique. The frequency which is made up by the microprocessor electronic system is turned into mechanical vibration. By piezo -ceramic crystal. By courtesy of vibration, the liquid into pot is vaporized without heating. Besides a fan which is in the nebulizer takes air from outside. This air by cleaning and filtering from the bacterium is pushed (provided) into the liquid pot. The vapor, which is vaporized continually, which is into liquid pot is run out by this air pressure and then the vapor reaches to sick person by tube.this vapor which is vaporized, when it wants, can be treat to sick person by turning into hot vapour. <4 1984 ISO 9001 ISO 13485
UN300A ACCESSORIES VAPOUR TUBING MEDICENE CUP NEBTIME ultrasonic nebulizers is a devices which produced to be used in the sick person s therapy by being vapourised of liquids and in solution condition madicines. During the liquid turn into the vapor, frequency uses instead of heating tecnique. The frequency which is made up by the microprocessor electronic system is turned into mechanical vibration. By piezo-ceramic crystal. By courtesy of vibration, the liquid into pot is vaporized without heating. Besides a fan which is in the nebulizer takes air from outside and pushed (provided) into the liquid pot. The vapor, which is vaporized continually, which is into liquid pot is run out by this air pressure and then the vapor reaches to sick person by tube. 300 ml <
CN01 COMPRESSOR NEBULIZER ACCESSORIES AIR CONNECTION TUBE NEBULIZING CUP ADULT MASK PEDIATRIC MASK AIR FILTER MOUTH PIECE NOSE PIECE It is a compact medical device designed to efficiently deliver physician prescribed medication to the bronchial lung passages. With proper care and use, it will provide you with many years of reliable treatment. This product is developed for the successful treatment of asthma, allergies and other respiratory disorders. It creates a stream of air that travels through clear tube to the nebulizer. When air enters the nebulizer, it will convert the prescribed medication into aerosol mist for easy inhalation. Your Compressor Nebulizer should be used under the supervision of a licensed physician and/or a respiratory therapist after reading the instructions manual. SPECIFICATIONS POWER TEKNİK ÖZELLİKLER AC 230 V / 50 Hz CURRENT 0,8 AMP MEDICATION CAPACITY 5 ml PARTICLE SIZE 0,5 ~ 10 µm MMAD 4 µm NOISE LEVEL BELOW 60 dba MAXIMUM MEDICATION CAPACITY 13 ml (cc) AVERAGE NEBULIZATION RATE MİN. 0,2 ml / min COMPRESSOR PRESSURE RANGE 30 ~ 36 PSI (max.) OPERATION PRESSURE RANGE 8 ~ 16 PSI LITER FLOW RANGE 6 ~ 8 lpm OPERATING TEMPERATURE RANGE 10 ºC ~ 40 ºC OPERATING HUMIDITY RANGE 10 ~ 90 % RH WEIGHT < 2 kg WORKING MODE CONTINUOUS ELECTRICAL SAFETY TYPE B - CLASS II 1984 ISO 9001 ISO 13485
e e CPAP ACCESSORIES CARRYING CASE FILTER TUBE HEADGEAR MASK HEATED HUMIDIFIER CASE OF HEATED HUMIDIFIER SPECIFICATIONS VOLTAGE TEKNİK ÖZELLİKLER 100 240 VAC, 50 / 60 Hz Sleep Apnea is a significant disease that causes breathing pauses and corruption of sleep patterns during sleep. Sleep pauses in sleep would cause reduce in the amount of oxygen and increase in the amount of carbon dioxide in blood. OPERATION TYPE ELECTRICAL CLASS OPERATION PRESSURE RANGE NOISE LEVEL MAX. LITER FLOW CONTINUOUS CLASS II, TYPE BF 2 ~ 20 hpa < 30 db >15 LPM SLEEPTIME CPAP is used in home and clinical environments treatment of this disease. The purpose in using this device is to keep the upper airways open during sleep by applying continues and constant air pressure. SLEEPTIME CPAP with special air pump, nasal mask, easy to carry ergonomic design, altitude compensation for accuracy in therapy, backlit LCD screen, very low noise level, easily integrated heated humidifier is designed to improve your quality of sleep and life. DIMENSION 220 x194 x112 mm WEIGHT < 2 kg OPERATION TEMPERATURE RANGE 5 ~ 40 º C OPERATION HUMIDITY RANGE 10 ~ 90 % RH non-condensing ATMOSPHERIC PRESSURE 86 ~ 106 kpa N/A STANDARD COMPLIANCE IEC 60601-1, ISO 17510 0123 ISO 9001 ISO 13485
e e AUTOCPAP ACCESSORIES CARRYING CASE FİLTER TUBE HEADGEAR MASK HEATED HUMIDIFIER CASE OF HEATED HUMIDIFIER Sleep Apnea is a significant disease that causes breathing pauses and corruption of sleep patterns during sleep. Sleep pauses in sleep would cause reduce in the amount of oxygen and increase in the amount of carbon dioxide in blood. SLEEPTIME AUTOCPAP is used in home and clinical environments treatment of this disease. The purpose in using this device is to keep the upper airways open during sleep by applying continues and constant air pressure. Using advanced sensor technology, SLEEPTIME AUTOCPAP automatically keeps the patient s respiratory conditions. By using this control system, it provides reliable Obstructive Sleep Apnea treatment to the patients. SLEEPTIME AUTOCPAP with special air pump, nasal mask, easy to carry ergonomic design, altitude compensation for accuracy in therapy, backlit LCD screen, very low noise level, easily integrated heated humidifier is designed to improve your quality of sleep and life. SPECIFICATIONS VOLTAGE TEKNİK ÖZELLİKLER 100 240 VAC, 50 / 60 Hz OPERATION TYPE CONTINUOUS ELECTRICAL CLASS CLASS II, TYPE BF OPERATION PRESSURE RANGE 2 ~ 20 hpa NOISE LEVEL < 30 db MAX. LITER FLOW >15 LPM DIMENSION 220 x194 x112 mm WEIGHT < 2 kg OPERATION TEMPERATURE RANGE 5 ~ 40 º C OPERATION HUMIDITY RANGE 10 ~ 90 % RH non-condensing ATMOSPHERIC PRESSURE 86 ~ 106 kpa N/A STANDARD COMPLIANCE IEC 60601-1, ISO 17510 0123 ISO 9001 ISO 13485
e e BPAP ACCESSORIES CARRYING CASE FILTER TUBE HEADGEAR MASK HEATED HUMIDIFIER CASE OF HEATED HUMIDIFIER Sleep Apnea is a significant disease that causes breathing pauses and corruption of sleep patterns during sleep. Sleep pauses in sleep would cause reduce in the amount of oxygen and increase in the amount of carbon dioxide in blood. SLEEPTIME BPAP is used in home and clinical environments treatment of this disease. The purpose in using this device is to keep the upper airways open during sleep by applying continues and constant air pressure. Using advanced sensor technology, SLEEPTIME BPAP automatically keeps the patient s respiratory conditions. By using this control system, it provides reliable Obstructive Sleep Apnea treatment to the patients. SLEEPTIME BPAP with special air pump, nasal mask, easy to carry ergonomic design, altitude compensation for accuracy in therapy, backlit LCD screen, very low noise level, easily integrated heated humidifier is designed to improve your quality of sleep and life. SPECIFICATIONS PRODUCT MODEL BPAP AUTOPBAP BPAP ST MODE CPAP CPAP,S CPAP,S,ST,T AUTOMATIC PRESSURE NO YES NO RESlex YES ALTITUDE COMPENSATION AUTOMATIC PRESSURE ( hpa ) 4 ~ 25 MAXIMUM FLOW 35 LPM ATMOSPHERIC PRESSURE 77 ~ 101 kpa NOISE LEVEL < 30 db DIMENSION 220 * 194 * 112 mm WEIGHT < 2 kg VOLTAGE 100 ~ 240 VAC, 50 / 60 Hz, 1.0 A OPERATION TEMPERATURE RANGE 5 ~ 35 º C OPERATION HUMIDITY RANGE 15 ~ 95 % RH non - condensing ELECTRICAL CLASS CLASS II, TYPE BF STANDARD COMPLIANCE IEC 60601-1, ISO 17510 0123 ISO 9001 ISO 13485
Elmaslar İmalat Tibbi Cihazlar İthalat İhracat A.Ş. Ağaç Metal San. Koop.1436 Sk. No: 14 Ostim Mah./ Ankara / Turkey Tel: +90 312 394 80 01 Fax: +90 312 394 80 04 info@elmaslarmedikal.com.tr elmaslarmedical@gmail.com