Association of Body Mass Index with Bone acceleration on Impulse response in Men and Women of South Indian Population

Similar documents
Development and Implementation of Instrumentation System for Diagnosing Bone Quality using Vibration Technique

Top: Healthy Vertebrae Above: Osteoporotic bone

AVR Based Gesture Vocalizer Using Speech Synthesizer IC

Biodynamic Response To Random Whole Body Vibration In Standing Posture

Test Procedure for Piezoelectric Accelerometer Ice Thickness Measurement

Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer

Prevalence of Osteoporosis p. 262 Consequences of Osteoporosis p. 263 Risk Factors for Osteoporosis p. 264 Attainment of Peak Bone Density p.

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Identification of Early Osteoporosis Using Intensity Slicing method

Design & manufacturing a computerized Multi-Channel Isometric Dynamometer

Risk factors associated with low bone mineral density in Ajman, UAE

Thickness Computation Under In-Vivo Trabecular Bone CT Imaging

Sign Language Interpretation Using Pseudo Glove

An Ingenious accelerator card System for the Visually Lessen

Dynamic Hollow Cylinder System Proposal

Omnisense: At Least As Good As DXA

Detection of Foot Ulcer using Pressure Kit M. Prem Anand 1, J. Sri Arunaa 2 1 Assistant Professor 2 M.E Student

LION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:

A Review on Gesture Vocalizer

A bioimpedance-based cardiovascular measurement system

BLOOD GLUCOSE LEVEL MONITORING BY NONINVASIVE METHOD USING NEAR INFRA RED SENSOR

Measuring Bone Mineral Density

Android based Monitoring Human Knee Joint Movement Using Wearable Computing

Detection of Diabetic disorders in the lower extremities: A cost effective screening device.

New Dual-energy X-ray Absorptiometry Machines (idxa) and Vertebral Fracture Assessment

BONE MINERAL DENSITY OF BANGLADESHI PEOPLE

CT Imaging of skeleton in small animals. Massimo Marenzana

Bone Mineral Densitometry with Dual Energy X-Ray Absorptiometry

JMSCR Vol 04 Issue 12 Page December 2016

AN AUTOMATED ATHLETE PERFORMANCE EVALUATION SYSTEM From theory to practice

PC BASED AUDIOMETER GENERATING AUDIOGRAM TO ASSESS ACOUSTIC THRESHOLD

Transducer/Receiver Function Test Procedure

Development of an Electronic Glove with Voice Output for Finger Posture Recognition

Norland Densitometry A Tradition of Excellence

MEDILINK PEGASUS Smart. The New Portable ultrasound Bone densitometer

The Evolution and Benefits of Phased Array Technology for the Every Day Inspector

Ultrasound Measurements and Non-destructive Testing Educational Laboratory

Embedded Based Hand Talk Assisting System for Dumb Peoples on Android Platform

CHAPTER 11 UNIVERSITY OF DENVER

Bone Densitometry. What is a Bone Density Scan (DXA)? What are some common uses of the procedure?

Orthopantomogram as an effective tool for the diagnosis of osteoporosis-a study

DESIGN AND IMPLEMENTATION OF A MECHATRONIC SYSTEM FOR LOWER LIMB MEDICAL REHABILITATION

LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps

Development of Indigenous Ultrasonic Data Acquisition and Recording System for ISI of Pressure Tubes of PHWR

Design of Context-Aware Exercise Measurement SoC Based on Electromyogram and Electrocardiogram

Estimation of Haemoglobin Using Non-Invasive Technique

Mechanical Vibration Causes, Effect, Analysis & Prevention Techniques

Modal Analysis of Hip Joint Implant Used In the Human Body

Bone density scanning and osteoporosis

Hollowed. Bone. 1. Definition of Term. Normal Bone. Osteoporosis 골다공증

Osteoporosis. By Amanda Neilson

Current Usage Reduction Through Stiffness Control in Humanoid Robot

Living with Newton's Laws

A Wearable Rehabilitation Activity Monitoring Device for Paralyzed Patients Finger

BIOLOGY and BIOMECHANICS OF NORMAL & OSTEOPOROTIC BONE

Design of the HRV Analysis System Based on AD8232

International Journal of Health Sciences and Research ISSN:

Interpreting DEXA Scan and. the New Fracture Risk. Assessment. Algorithm

Augmentation of the In Vivo Elastic Properties Measurement System to include Bulk Properties

DEVICE FOR MUSCLE COORDINATION IMPROVEMENT

Development and application of a hand force measurement system

DESIGN OF AUTOMATIC INSULIN DOSAGE INDICATOR FOR DIABETIC PATIENTS USING BMI

Test the Mechanical Properties of Articular Cartilage using Digital Image Correlation Technology

Optical sensor for Indian Siddha Diagnosis System

COMPUTER PLAY IN EDUCATIONAL THERAPY FOR CHILDREN WITH STUTTERING PROBLEM: HARDWARE SETUP AND INTERVENTION

WHAT KEEPS OUR BONES STRONG?

Information Processing of Medical Images for the Detection of Osteoporosis in Hip Region of Interest

Comparison of in Vitro Young and Old Lumbar Vertebrae of Ewes Related to Bone Density and Compression Strength

Nutritional Aspects of Osteoporosis Care and Treatment Cynthia Smith, FNP-BC, RN, MSN, CCD Pars Osteoporosis Clinic, Belpre, Ohio

Diagnosis of Diabetes Based on Nadi Pariksha Using Tridosha Analysis and ANN

A STUDY OF ULTRASOUND MEASUREMENT UTILIZED FOR THE LIVER TESTING

Bone Stimulators and Their Use in Horses and People

Osteoporosis. Current Trend in Osteoporosis Management for Elderly in HK- Medical Perspective. Old Definition of Osteoporosis

Linear Ultrasonic Wave Propagation in Biological Tissues

EMG-Driven Human Model for Orthosis Control

ACOUSTORAPHY Acousto-Optical (AO) Ultrasonics & Its Applications

DESIGN OF SMART HEARING AID

Correspondence should be addressed to Jayadevan Sreedharan,

Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound

LATEST TRENDS on SYSTEMS (Volume I) New Seismocardiographic Measuring System with Separate QRS Detection. M. Stork 1, Z. Trefny 2

DXA When to order? How to interpret? Dr Nikhil Tandon Department of Endocrinology and Metabolism All India Institute of Medical Sciences New Delhi

Biceps Activity EMG Pattern Recognition Using Neural Networks

a. Magnitude, direction, point of application, line of action a. Weight is a force and mass is the quantity of matter in the body

Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011

Vertical and Fore-Aft Seat-to-Head Transmissibility Response to Vertical Whole Body Vibration: Gender and Anthropometric Effects

Microcontroller and Sensors Based Gesture Vocalizer

Terminology Tissue Appearance

ME/BioE C176 Final Exam, Fall 2001

Preliminary technical data

OPTION I TEST REVIEW

WHOLE BODY VIBRATION THERAPY

Bone Mineral Density and Its Associated Factors in Naresuan University Staff

AT89C51 Microcontroller Based Control Model for Hybrid Assistive Limb (Knee )

DCNV RESEARCH TOOL: INVESTIGATION OF ANTICIPATORY BRAIN POTENTIALS

Foot Rehabilitation Monitoring Device

Descriptions of NDT Projects Fall 2004 October 31, 2004

Effect of the femoral stem size on femur bone quality towards THR

GUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement.

HiFFUT A New Class of Transducer

Transcription:

Biomedical Research 2014; 25 (4): 471-475 ISSN 0970-938X http://www.biomedres.info Association of Body Mass Index with Bone acceleration on Impulse response in Men and Women of South Indian Population S. Mythili 1 and G. Athisha 2 1&2 Department of Electronics and Communication Engineering 1&2 PSNA College of Engineering & Technology, Dindigul, Tamilnadu, India Abstract Bone quality diagnosis is recognized as an important health issue particularly in women. Bone mineral density (BMD) is the major measurable determinant of the risk of bone disease such as Osteoporosis. Several studies showed that the Body Mass Index (BMI) and Body weight are associated with BMD. The aim of present study is to find out the effect of body mass index on bone mineral density through acceleration parameter by Impulse response. The present study was performed on human volunteers (30 men and 30 women in each group) under 20 to 25 years and 45-55(Premenopausal women) and 56-65(Post menopausal women) age groups. The experiment was carried out by using the developed Instrumentation setup which utilizes the vibration technique for its operation and MEMS accelerometer sensors are used to pick up the vibration signal propagation response through leg bone as acceleration. BMI information of the subjects who were participated in this experiment was determined by measuring the height and weight of them using standard scales. Observation showed a significant relationship between the BMI and BMD in terms of acceleration of normal and overweight subjects of men and women under different age groups. High BMI or body weight is correlated positively with Bone acceleration in both men and women (p < 0.05) while lower body weight is associated with lower BMD. Keywords: Bone Mineral Density, Body Mass Index, Peak Acceleration June 01 2014 Introduction Bone disease is characterized by low bone mass and micro architectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture 1-2. The bone related problem is ever increasing and studies in both advanced and developing nations indicate high risk of osteoporosis. Number of hip fractures worldwide due to weak Bone Mineral Density (BMD) is increasing day to day in all countries. So it is an urgent need for early detection, diagnosis and preventive strategies for Bone health problems. The diagnosis and clinical management of this health relies mainly on the measurement of bone density, because low bone density is associated with it..several techniques have been developed for the measurement of bone density and most of these techniques used some form of ionizing radiation like X-rays which is harmful to the human subjects.the measurement obtained is based on the attenuation of a beam of energy as it passes through bone and soft tissues. Although bone density shows a high correlation with bone strength, as much as 25-30% of the observed variation in bone strength may be due to the cumulative and synergistic effects of other factors, such as bone microstructure, architecture, and state of remodelling 5-6. Bone density measurements are incapable of measuring directly the effects of any of these factors on bone. In particular a measure of the biomechanical competence of the skeleton cannot be obtained using bone densitometer technique The use of impulsive force in the form of sound wave propagation through bone has been suggested as possible choice for the assessment of bone integrity and to determine bone s response to mechanical force predicts the risk of BMD reduction. The vibration as a result of low force applied on bone may have the ability to inform on several properties of bone since interacts with bone in a fundamentally different way compared with ionizing electromagnetic radiation. This, combined with the fact that sounds involves no radiation and is relatively simple to implement and process. Ionizing radiation attenuates at the atomic level whereas impulse attenuates at the macroscopic structural level. Moreover, this vibration Biomed Res- India 2014 Volume 25 Issue 4 471

Mythili/Athisha technique does not measure the density or content of bone mineral directly; it has frequently been described as a measure of bone quality in terms of acceleration. In this bone quality assessment method, a force is applied on the leg bone; the impulsive response is collected by two vibration sensor attached at different location on the shaft of leg bone. Several showed that the relationship between vibration response (acceleration) and the BMD. That is, the magnitude of acceleration is low if the BMD is good for a particular bone and vice versa. In this approach, the vibration properties of the tissue can be obtained by comparing the received signal and this requires two accelerometer sensors. The ability of an impulsive sound wave to provide information about the medium or tissue through which it is being propagated depends on the way by which the wave is altered by the medium and it also depends on the micro structural nature. Material and Methods A new setup is proposed in order to improve the performance of the existing system by incorporating automatic hammer which can produce a constant magnitude of force or impulse (4-Newton).A force sensor is attached at the hammer tip. The hammer movement is controlled by a microcontroller by programming and the two vibration sensors are used to acquire the vibration (in terms of acceleration) responses and are analyzed using DAQ (Data Acquisition card) by interfacing with a PC. The automated hammer is operated by switches that runs by the DC motor hits the Medial Condyle region in the leg with uniform magnitude and the impulse response that travels through the shaft portion of the leg bone. The accelerometer-i is placed on the facies medialis tibia at a distance of 8 cm from medial condyle and accelerometer-2 is placed at a distance of 20 cm from the accelerometer- 1 and the two sensors are fixed firmly on a belt like weightless strap without imposing extra loading on bone. In this configuration of mounting, among the three axes (X,Y and Z) of the accelerometers, Y axis response is only considered for further analysis since it is sensitive and dominating whereas other axis responses are very minute and hence ignored. The accelerometer used in this setup is capacitive type MEMS accelerometer (ADXL335-NSK Electronics Co.). It is small, thin, low power, 3-axis accelerometer with signal conditioned voltage outputs. The product measures acceleration with a minimum full-scale range of ±3 g. It can measure the dynamic acceleration resulting from motion, shock, or vibration. Figure 1. The Block diagram of the Instrumentation setup For interfacing the hardware with PC, DAQ card USB- 1208FS Data Acquisition Card (Measurement Computing Co.) is used.tracer DAQ software is included for acquiring and displaying data and generating signals. The Hardware part consists of a microcontroller AT89552 is used for controlling the knock as desired. The microprocessor is running under the core of 8051 principle. Flash programming which is used, so that it can be made rewritable in order to increase or decrease the speed of the motor setup. It has 4 ports namely PORT0, PORT 1,PORT 2 and PORT 3..PORT 0 is used for controlling the switches. PORT 1 is used for controlling the Digital to Analog converter. From the microcontroller, PORT 1 is connected tothedac0808 combined with an Integrated circuit(ic) operational amplifier 74, for the amplification purpose of the signals generated. DC motors are part of the electrical section using DC power as energy source. The ADXL335 is a small, thin, low power, complete 3- axis accelerometer with signal conditioned voltage outputs. The product measures acceleration with a minimum full-scale range of ±3 g. It can measure the dynamic acceleration resulting from motion, shock, or vibration.. The USB-1208LS offers two, 10-bit analog output channels with DAC rates up to 100 S/s. TheUSB- 472 Biomed Res- India 2014 Volume 25 Issue 4

1208FS/1408FS both offer two, 12-bit analog output channels with DAC rates up to 10 ks/s.using our set up, the data were collected from men and women with various age groups. Subject Recruitment and Data collection The experimental arrangement was such that the subject was asked to sit comfortably on a chair by keeping the legs vertically on a vibration free wooden platform. The preselected points for the hammer strike and for the accelerometers mounting were marked on the leg bone and the sensors are attached. Before commencing the experiment the subject was asked to give the feedback for the questionnaire which consists mainly about the age, sex, height, weight, medical history, Menopause state for women etc in order to segregate them in to various groups. Data are collected from 30 subjects of men and women(from each case) under 20-25 years age group and 30 subjects of men and women(from each) under 45-55 and 56-65 age groups. Body Mass Index (BMI) (Kg/cm²) Weight calculated by weighing machine and height by standard scale. BMI was calculated by using following formulae: BMI (kg/cm 2 ) = Weight (kg)/ Height (cm 2 ) acceleration value from acceleration sensor-1 is higher than sensor-2 because of the propagation delay of the impulse. Men have good BMD than women so their acceleration value is less compared to women with same 2.4 1.6 0.8 BMI Vs. Peak Acceleration of subjects under 20-25 age group Women 0.0 22.0 22.5 23.0 23.5 Body Mass Index in kg/sq.m BMI Vs. Peak Acceleration of Subjects under 20-25 age group Men Women Men Accelerometer -I Table 1. BMI range Interpretation according to WHO BMI (kg/sq.cm) Classification Principal cut-off points Underweight < 18.50 Normal range 18.50-24.99 Overweight 25.00 Obese 30.00 1.2 0.6 0.0 26.4 27.2 28.0 Results and Discussion From the acceleration peak and the estimated BMI values it is found that there is a relationship between both the parameters for various groups. The value of acceleration is less for men under the age group of 20-25 years when compared to their age matched cohorts. This is because of their good BMD during this stage and also according to the hypothesis that women have less BMD than their age matched cohorts and so their bone gets more accelerated. This was proved also by statistical tests and significant difference is seen in both the Accelerometer outputs based on the obtained p values. The above graphs shows the comparison between men and women subjects under 20-25 age groups with normal and overweight ranges. This shows that the peak Graph 1. Comparison of BMI (normal range) and (overweight) with Peak acceleration of subjects under 20-25 age group age group. It is also observed that when the BMI is increased the acceleration is decreased in both the cases.the above two graphs shows the relationship between acceleration values with BMI for women (pre and postmenopausal cases) under 45-65 age groups. In the case of Post menopausal women (Age 56-65 years), the acceleration is more compared to premenopausal women (Age 45-55 years). Moreover, there exists significant differences with BMI ranges (p<0.05). Biomed Res- India 2014 Volume 25 Issue 4 473

Mythili/Athisha 3 BMI Vs. Peak Acceleration of Premenopausal Women (45-55 age group) from Osteoporotic and Osteopenia patients in order to strongly prove the usage of the setup to assess the quality of bone. Frequency domain analysis can also be done and several parameters will be analysed. Acknowledgement 2 1 The authors would like to thank Dr. Muralidharan, Chief Doctor, DCC (Hospital), Dindigul for extending his valuable support in data collection from human subjects and all the volunteers who had participated in this study and the faculties of PSNA College of Engineering & Technology, Dindigul for their moral support to complete this study. References 3 2 1 0 0 24 27 BMI Vs. Peak Acceleration of Post Menopausal Women(56-65 age group) 24 26 28 Graph 2. Comparison of BMI (overweight) with Peak acceleration of subjects under 45-56 and 56-65 age group Conclusion In this paper analysis of data for different human subjects with different age groups were done. With the experimental result with the measured BMI of subjects, we observed that there exists a relationship between BMI and BMD among subjects. By using Statistical test we proved the hypothesis. From the results, using our developed instrumentation set up, the quality of bone may be diagnosed and this can be used as simple equipment for this purpose. As a future work, data will be collected 1. Currey JD. 1988, The effect of porosity and mineral content on the Young s modulus of elasticity of compact bone, Journal of Biomechanics 1988; l.21: 131-139. 2. Mc Gowan. JA. Osteoporosis: assessment of bone loss and remodelling, Aging, Clinical and Experimental Research 1993; 5: 81-93. 3. Pelke RR, Saha S. Stress wave propagation in bone. Journal of Biomechanics 1983; 18: 745-753. 4. Bekir Bediz & Nevzat Ozguven. H. 2010, Vibration measurements predict the mechanical properties of human tibia, Clinical Biomechanics, vol. No.25, pp.365 37. 5. Man-Ying Wang & George J. Salem.2004, The relations among upper-extremity loading characteristics and bone mineral density changes in young women Bone, vol.no.34, pp.1053-1063. 6. Melton LJ, Achenbach. Quantification and Assessment of Osteoporosis using DEXA-Dual Energy X-ray Absorptiometry Technique, Osteoporosis International 2000; 21: 1161-1169. 7. Gandhi A & Shukla A. 2005, Evaluation of BMD of women above 40 years of age, Journal of Obstetrics & Gynaecology 2005; 55: 265-267. 8. Hafeez F, Zulfiqur S, Hasan KR. An assessment of osteoporosis and low bone density in postmenopausal women Pakistan Journal of Physiology 2009; 5: 41-44. 9. Stein, G.J., Chmúrny, R., Rosík, V. 2007, Measurement and analysis of low frequency vibration, Measurement Science Review, vol. No.7, pp.47-50. 10. Holi. MS, Radhakrishnan.S, Swarnamani.S, Jeyavelan. NA. Quantitative ultrasound technique for the assessment of osteoporosis and prediction of fracture risk. Journal of Pure and Applied Ultrasonics 2005; 27: 55-60. 11. Alhussein Albarbar, Samir Mekid, Andrew Starr & Robert Pietruszkiewicz.2008, Suitability of MEMS Accelerometers for Condition Monitoring: An experimental study, Sensors 2008; 8: 784-799. 12. Stein GJ, Chmúrny R, Rosík. V. Measurement and analysis of low frequency Vibration. Measurement Science Review 2007; 7: 47-50. 474 Biomed Res- India 2014 Volume 25 Issue 4

13. Kataria SK, Pareek P, Dadhich A, Kataria KR, Bhati M. The Effect of Body Mass Index on Bone Mineral Density in pre and post menopausal women of Western Population, International Journal of Biological Medical Research 2002; 3: 1899-1901. 14. Holi.MS, Radhakrishnan S. In Vivo assessment of Osteoporosis in women by impulse response technique, in IEEE Region 10 Technical Conference on Convergent Technologies for The Asia-Pacific: Proceedings of the IEEE TENCON International Conference: Bangalore, 2003; pp. 14-17. Correspondence to: S. Mythili Department of Electronics and Communication Engineering PSNA College of Engineering & Technology Dindigul 624622 Tamilnadu, India Biomed Res- India 2014 Volume 25 Issue 4 475