ST-513-S ST-514-S 15ST-515-S

Similar documents
Products. Airway Management

Boston. Medical Products. laryngeal and esophageal products

complete product catalog

Novatech Products for Interventional Pulmonology

The use of metallic expandable tracheal stents in the management of inoperable malignant tracheal obstruction

External trauma (MVA, surf board, assault, etc.) Internal trauma (Endotracheal intubation, tracheostomy) Other

Complex Airway problems - Paediatric Perspective

Neonatal Airway Disorders, Treatments, and Outcomes. Steven Goudy, MD Pediatric Otolaryngology Emory University Medical Center

Use of the Silicone T-tube to Treat Tracheal Stenosis or Tracheal Injury

TRACHEOSTOMY. Tracheostomy means creation an artificial opening in the trachea with tracheostomy tube insertion

DUMON-NOVATECH Y-STENTS: A FOUR-YEAR EXPERIENCE WITH 50 TRACHEOBRONCHIAL TUMORS INVOLVING THE CARINA

Double Y-stenting for tracheobronchial stenosis

4/24/2017. Tracheal Stenosis. Tracheal Stenosis. Tracheal Stenosis. Tracheal Stenosis. Tracheal Stenosis Endoscopic & Surgical Management

Therapeutic Bronchoscopy Etiology - Benign Stenosis Post - intubation Trauma Post - operative Inflammatory Idiopathic

Since central airway stenosis is often a lifethreatening. Double Y-stenting for tracheobronchial stenosis. Masahide Oki and Hideo Saka

CHAPTER 7 Procedures on Respiratory System

Proceedings of the World Small Animal Veterinary Association Mexico City, Mexico 2005

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL

Advanced Bronchoscopy

Merete BLP. Surgical Technique. - Bunion Locking Plate - Low Profile Locking Bone Plate System

MEDPOR. Oral maxillofacial surgery

Tracheal Trauma: Management and Treatment. Kosmas Iliadis, MD, PhD, FECTS

How to use the Control-Cric to perform a surgical cricothyrotomy

High Acceptance. Maximum Mobility. Maximum Cost-Effectiveness. twist. a b c

Contents. Part A Clinical Evaluation of Laryngeal Disorders. 3 Videostroboscopy and Dynamic Voice Evaluation with Flexible Laryngoscopy...

Montgomery T-tube placement in the treatment of benign tracheal lesions

Technique Guide. SynPOR Porous Polyethylene Implants. For craniofacial and orbital augmentation and reconstruction.

Temporary and permanent restoration of airway continuity with the tracheal T-tube

AERO DV Tracheobronchial Direct Visualization Stent System

SYNPOR POROUS POLYETHYLENE IMPLANTS. For craniofacial and orbital augmentation and reconstruction

Clearing the air.. How to assist and rescue neck breathing patients. Presented by: Don Hall MCD, CCC/SLP Sarah Markel RRT, MHA

Rota-Trach Double Lumen Tracheostomy Tube VITALTEC

Pediatric partial cricotracheal resection: A new technique for the posterior cricoid anastomosis

Full Range of Tracheostomy Solutions

Rhinology Products. Rhinology Products. Superior solutions for superior patient care.

Flexible Fragment Fixation. Surgical Technique

Talent Abdominal Stent Graft

Subglottic stenosis, with involvement of the lower larynx

THE RESPIRATORY SYSTEM

TRUSTED SOLUTIONS FOR SIMPLIFIED PATIENT CARE. Shiley Tracheostomy Product Guide GettyImages

DYNAMIC, TRANSVERSE COMPRESSION. Low Profile, Anatomic Design, Type II Anodized. Mechanical Compression Designed to Stimulate the Fusion Process

Disclosures. Learning Objectives. Coeditor/author. Associate Science Editor, American Heart Association

RECOVERY. P r o t r u s i o

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Idiopathic laryngotracheal stenosis

Colonic Metal Stents MAKING A DIFFERENCE TO HEALTH

Day 2 Pulmonary Breakout Interventional Pulmonology

Basic Science Review Wound Healing

Tracheal stenosis in infants and children is typically characterized

DESIGNED FOR DIFFICULT TRACHEAL OR ESOPHAGEAL INTUBATION

Case Report. Management of recurrent distal tracheal stenosis using an endoprosthesis: a case report* Abstract. Introduction.

Adult Patients Going Home with a Tracheostomy

30+ MEDPOR biomaterial. years of proven clinical history

MEDPOR. Oculoplastic surgery

TRACHEOSTOMY CARE. Tracheostomy- Surgically created hole that extends from the neck skin into the windpipe or trachea.

Anatomy of the Airway

Full Line Catalogue. Tracheostomy Products. Laryngectomy Products. Cuff Pressure Management. Accessories. Information

Microdebrider. Microdebrider. Mohamed Hesham,MD. The Management of Different Laryngeal Lesions. Dr. Ahmad Yassin 4/11/2013

LARYNGOSCOPES/TRACHEASCOPES

Locking Radial Head Plates

LEVITAN S FIBREOPTIC STYLET: BEYOND BARRIERS. - Our Perspective.

OPEN ACCESS ATLAS OF OTOLARYNGOLOGY, HEAD & NECK OPERATIVE SURGERY

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Translaryngeal tracheostomy

Tracheostomy/ Laryngectomy PRODUCT CATALOG

ACDF. Anterior Cervical Discectomy and Fusion. An introduction to

Section 4.1 Paediatric Tracheostomy Introduction


Gastric / EUS Metal Stents

creating stability a bess group company Stents for Gastroenterology

Стенты «Ella-cs» Уважаемые коллеги! Высылаем очередной выпуск «Issue of ELLA Abstracts»

Geoffrey Axiak M.Sc. Nursing (Manch.), B.Sc. Nursing, P.G. Dip. Nutrition & Dietetics Clinical Nutrition Practice Nurse

Swallowing after a Total Laryngectomy

FROM THE EVERYDAY TO THE EXTRAORDINARY

Surgical Technique. Proximal Humerus Locking Plate

Implant Preparation. Page 1

SHOULDER EXTRACTION INSTRUMENTS

CROSS CODER. Sample page. Anesthesia. codes to ICD-10-CM and HCPCS. Essential links from CPT. Power up your coding optum360coding.

Technique Guide. ARCH Laminoplasty System. Dedicated System for Open-door Laminoplasty.

AcUMEDr. Locking Proximal Humeral Plate. PoLARUSr PHPt

Tracheal Stenosis Following Cuffed Tube Tracheostomy

Cytoflex Barrier Membrane Clinical Evaluation

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH

MARKING RING VEIN GRAFT VALVE INSTRUMENTS. Hook, Valve. TFX SURGICAL SPECIALTIES Phone Toll Free: Fax:

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

3. Urinary Catheters. Indications. Methods of Bladder Catheterization. Hashim Hashim

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

28 Surgical Technique

ORIGINAL ARTICLE. Posterior Cricoidotomy Lumen Augmentation for Treatment of Subglottic Stenosis in Children

versatile SOLUTION for COMPLEX fractures

versatile SOLUTION for COMPLEX fractures

Integra. ADVANSYS Plating System SURGICAL TECHNIQUE

Ears. Mouth. Jowls 6 Major Bones of the Face Nasal bone Two

UNITE Foot Plating System

Respiratory distress in patients with central airway obstruction

PRODUCTS FOR THE DIFFICULT AIRWAY. Courtesy of Cook Critical Care

A New EVAR Device for Infrarenal AAAs

MITROFLOW VALSALVA CONDUIT TM

Transcription:

Urmee Healthcare G-1, sho Plalav, (Jwala Estate), Opp. Flyover ridge, S. V. Road, orivali (W), Mumbai - 0 02. INDI +1 22 2 1, 4 5 Telefax : +1 22 2053 Email : deena@vsnl.com LRYNGOLOGY Hood Tracheal T-Tube Ultra-smooth Plus Standard Tracheal T-Tubes Hood Tracheal T-Tubes are designed with the stopper plug attached to the extraluminal limb to ensure the most secure placement, and to offer convenience in daily cleaning, maintenance and training. The single-piece construction eliminates misplacement of plugs while medical personnel are developing routine breathing and maintenance. The Ring Flanged Plug can be detached and threaded over the extraluminal limb to fit snugly against the patient's tracheostoma, adding security by reducing excessive movement of the T-Tube. The smooth extraluminal stem provides comfort for a wide range of patients, thin and obese, and eliminates complications in cases of edema. * Safety : placement of T-Tube secured with Ring Flange ensures a no slip fit * Comfort : Ring Flange easily adjusts to neck size * Widest range of T-Tube sizes available Pediatric and Standard Tracheal T-Tubes O.D (mm) ST--S ST-7-S 7 ST--S ST--S ST-5-S ST-5-S ST-5-S ST-513-S 13 ST-5-S 15ST-515-S ST-5-S = 13 1 27 31 31 32 34 31 = 15 21 22 24 C= 3 44 55 4 4 3 D= 5 Hood Thoracic T-Tube Ultra-smooth Plus Hood Tracheal and Thoracic T-Tubes enable short-term surgical management of tracheal and subglottic stenosis and the reconstruction of cervical and thoracic trachea. These patented devices are designed to maintain patency of the tracheal airway and to provide respiration through the larynx. The T-Tubes, made of medical-grade silicone material, will not harden and are nonreactive and nonirritating to ensure patient comfort. Tracheal T-Tubes with standard and long limbs serve as both a tracheotomy tube and a tracheal stent. Thoracic T-Tubes are designed with extra-long limbs to bypass and stent a tracheal stenosis between the thoracic inlet and the carina. The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion and removal technique, sterilization, and postoperative care.

ELT-0-S Long Tracheal T-Tubes = = C= D= LT--S LT-7-S LT--S LT--S LT-5-S LT-5-S 7 13 34 7 5 5 3.5 3 43 O.D. size corresponds to outside diameter of intratracheal limb in millimeters. patents pplied. 3 2 55 LT-5-S 72 5 LT-513-S 72 LT-5-S 72 LT-5-S 1 24 LT-5-S 1 24 55 O.D (mm) = = C= D= shaded area indicate pediatric sizes. Extra Long Thoracic T-Tubes (extra-long tubes with free standing plug) 5 ELT-07-S 7 ELT-0-S 4.5 ELT--S ELT--S These tubes are designed to be cut to desired lengths but care must be taken to trim and smooth the cut edges. Custom-cut lengths are available upon request. 41 3 4 ELT--S 7 74 Tracheal Stent With Posts Ultra-smooth Plus Injury of the upper airway commonly results in stenotic lesions of the larynx, subglottis, and adjacent trachea. The Hood Tracheal Stent with Posts offers physicians an excellent alternative to the traditional approach of surgical correction and YG laser resection. The device is placed in the trachea at the point of stenosis as a palliative technique for tumors causing extrinsic compression of the large airway. It may also be used for patients with benign tracheostenosis. The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion and removal technique, sterilization, and postoperative care. * ids in short-term management of airway obstructions after lung transplants, tuberculosis, malignancies * ids in normal breathing and speech * Permits healing and prevents desiccation * iocompatible medical-grade silicone * Posts aid in preventing migration Tracheal Stent with Posts vailable with Ultra-smooth" surface treatment. The proprietary technology modifies the surface properties of silicone. Ultras m o o t h" t r e a t e d s i l i co n e i s thromboresistant, resistant to biofilm germination and bacterial and fungal growth, and has less surface friction. TSP - - S TSP - - S TSP - 13 - S TSP - - S TSP - - S TSP - 15 - S TSP - - S TSP - - S TSP - - S TSP - - S TSP - 0 - S TSP - - S TSP - - S TSP - - S TSP - 0 - S TSP - 0 - S O.D. (mm) 13 15 Length (mm) 0 0 0

Harrell Y Stent with Posts Ultra-smooth Plus The Harrell Y Stent*, designed with James H. Harrell II, M.D., allows physicians to address airway complications such as anastomosis and stenosis. The stent may also be used to minimize chronic bronchial strictures due to tuberculosis and malignancies. The posts help prevent migration of the stent after placement. Inserted endoscopically, the specially designed bifurcated tracheobronchial tube fits snugly into the distal trachea, the carina and the proximal bronchi. Fabricated of flexible, biocompatible, implant-grade silicone, the Harrell Y Stent allows humidification and phonation. The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion and removal technique, sterilization, and postoperative care. * Designed with assistance from James H. Harrell II, M.D. University of California at San Diego ids in short-term management of airway obstructions after lung transplants, tuberculosis, malignancies ids in normal breathing and speech Permits healing and helps prevent desiccation iocompatible implant-grade silicone Y-ngle anatomically designed Posts aid in preventing migration O.D.1 size corresponds to outside diameter of intratracheal limb in millimeters. Harrell Y Stent with Posts O.D. 1 O.D. 2 C HYP S.5 HYPS S.5 35 HYP S 25 35 HYPS S 45 25 HYP S These products have been treated with Ultra-smooth Plus surface treatment. This proprietary technology modifies the surface properties of silicone. Ultra-smooth Plus treated silicone is thromboresistant, resistant to biofilm germination and bacterial and fungal growth, and has less surface friction. See Ultra-smooth Plus ronchial Stent With Posts Ultra-smooth Plus The Hood ronchial Stent is designed to relieve airway complications such as anastomosis and stenosis following lung transplant. The stent may also be used to minimize chronic bronchial strictures due to tuberculosis and malignancies. Inserted endoscopically, both ends of the tube are flanged to prevent movement after surgical placement in the bronchus. Fabricated of flexible, biocompatible, implant-grade silicone, the bronchial stent allows normal humidification and phonation. ronchial Stent with Posts (anchoring studs) are also available for physicians who prefer the anchoring studs over the rings on the original design. The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion and removal technique, sterilization, and postoperative care. ids in short-term management of airway obstructions after lung transplants, tuberculosis, malignancies. Enables normal breathing and speech Permits healing and prevents desiccation iocompatible implant-grade silicone dditional lengths and diameters are available upon request ronchial Stent with Posts (anchoring studs) SP S SP S SP S SP S SP S SP S SP S SP S SP S SP S O.D. (mm) Length (mm)

Stents are available with Ultra-smooth Plus surface treatment.this proprietary technology modifies the surface properties of silicone. dvantages include : + iocompatibility Thromboresistant, resistant to biofilm formation, resistant to bacterial and fungal growth + Slippery surface Smooth, reduction of friction, no need for lubricants + Extended product life Improves hydrophilicity, wear resistant, abrasion resistant, improves fatigue strength + Reduces rates of infection and thrombosis Laryngeal Stent Hood Laryngeal Stents provide soft, solid, conforming support for use in laryngeal fracture, laryngeal stenosis and subglottic stenosis. Laryngeal stents are molded to a precise hardness to provide support, but not injure surrounding tissue. They bend easily, are compressible and conform to the inner contour of the larynx. Skin or mucosal grafts may be sutured directly to the stent which is then inserted and held in place by silicone surface buttons. The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion and removal technique, sterilization, and postoperative care. Prevent and treat laryngeal stenosis Silicone material prevents tissue reaction Designed to conform to normal endolaryngeal surface Four sizes are available for precise patient fitting Surface buttons provided with suture holes Laryngeal Stents Millimeters C Child LSC - 33 dolescent LS - 15 37 Female (dult) LSF - 25 Male (dult) LSM - 47 15 dditional uttons LS - - - -

Laryngeal Umbrella Keel Hood Laryngeal White Umbrella Keels are designed for use following repair of anterior laryngeal stenosis, subsequent to removal of a laryngeal stent, to insure reformation of a sharp anterior commissure and to prevent formation of an anterior web. Clear umbrella keels are also available. oth are indicated for use after hemilaryngectomy to prevent stenosis. The soft, solid conforming structure consists of an umbrella-like extralaryngeal cover and a thin intralaryngeal insert. The extralaryngeal surface is secured to the thyroid laminae to protect the thyrotomy repair. It is designed so that, with a figure-of-eight suture, the keel can be held tightly enough to inhibit synchronous motion between the intralaryngeal keel insert and the vocal cords, thus preventing granulation formation and preserving phonation. The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion and removal technique, sterilization, and postoperative care. * Precisely molded medical-grade silicone provides for a flexible, thin and non-irritating keel. * Readily conforms to anatomy of the anterior commissure * White umbrella keel enables easy visualization for removal Three sizes are available Laryngeal Umbrella Keels LK- LK- LK- RLK- RLK- RLK- Type Clear Clear Clear White White White (mm) (mm) Salivary ypass Tubes Hood Salivary ypass Tubes are designed to control salivary leakage from the pharyngocutaneous fistula after total laryngectomy, and to stent the cervical esophagus following dilation of a stricture. ypass tubes are frequently used in patients with poor wound healing due to systemic problems (e.g., poor nutritional status, metabolic disorders) or regional factors (e.g., postirradiation changes, recurrent or persistent neoplasm, chronic infection). ecause of these host factors, placement of the tubes may be associated with pressure necrosis of local tissues. Therefore, patients with these tubes in place should be monitored carefully by x-ray and direct inspection if localized pressure necrosis of regional soft tissue is suspected. The tubes are designed to fit securely in the superior esophagus and hypopharynx. However, it is possible for a loose-fitting tube to be displaced distally into the esophagus. This may be prevented by securing the tube to an indwelling gastric tube. The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion and removal technique, sterilization and postoperative care. Cost-effective alternative to laser therapy with equal palliation of esophageal carcinoma Funnel shaped superior end conforms to hypopharynx Flexible with a large I.D./O.D. ratio allowing maximum nutritional intake Enables spontaneous closure of a fistula Soft implant grade silicone

Salivary ypass Tubes Diameter C (mm) (mm) ST 0 mm (O.D.) for use with nasogastric feeding tube ST mm (O.D.) for use with nasogastric feeding tube 24 ST mm (O.D.) for use with nasogastric feeding tube 24 ST mm (O.D.) for use with nasogastric feeding tube 27 ST mm (O.D.) for use with nasogastric feeding tube 5 ST mm (O.D.) for use with nasogastric feeding tube 32 ST mm (O.D.) for use with nasogastric feeding tube 34 5 Silicon lock Description : Implantable silicone block for use in augmentation of bone or cartilaginous features as well as designing the prosthesis in ENT / Head-Neck Surgery. Special advantages : May be carved with a knife or scissor. Will not attach to underlying or surrounding tissues. Can be repeatedly autoclaved. Indications : For use in designing Mandibular as well as nasal prosthesis and also for Thyroplasty.