Correction System. Surgical Technique

Similar documents
Bunion Correction System

Correction System. Surgical Technique

MSP TM Metatarsal Shortening System. Surgical Technique

Correction System. Surgical Technique

Axi+LineTM Proximal Bunion CorrectionSystem. Surgical Technique

MSP TM Metatarsal Shortening System. Surgical Technique

Correction System. Surgical Technique

Accu-Cut Osteotomy Guide System

InCoreTM Lapidus System

Merete BLP. Surgical Technique. - Bunion Locking Plate - Low Profile Locking Bone Plate System

Flower Opening Wedge Plate

Re+Line Bunion Correction System for Correction of Hallux Abducto Valgus Deformity

Contents. Chapter 1 4 Chapter Chapter Chapter Chapter 5 15

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

The Flower Straight Fibula Plate

DARCO. Bow 2 Plate SURGIC AL TECHNIQUE

Humeral SuturePlate. Surgical Technique

Surgical Technique. Olecranon Locking Plate

Merete PlantarMAX Lapidus Plate Surgical Technique. Description of Plate

LCP Anterior Ankle Arthrodesis Plates. Part of the Synthes Locking Compression Plate (LCP) System.

3.0 mm Cannulated Screw System. Surgical Technique

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Technique Guide. Locking Attachment Plate. For treatment of periprosthetic fractures.

Osteotomy System. The reference lines on the plate help facilitate the creation of the osteotomy, when a free hand cut is preferred.

INnate. Surgical Technique Guide. Anatomic Fixation in Your Hands. The INnate Implant

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

MetaFix Ludloff Plate

Biomet Large Cannulated Screw System

Instrument and Implant for wrist fracture

lower extremity fixation system

Surgical Technique. Distal Humerus Locking Plate

The Flower Forefoot PROCEDURE GUIDE.

System. Humeral Nail. Surgical Technique

LCP Distal Humerus Plates

Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion Spacer

Surgical Technique. Forearm Fracture Solutions

MPJ Implant System. Patents Pending Worldwide

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

The Flower Medial Column Fusion Plate

Integra. ADVANSYS Plating System SURGICAL TECHNIQUE

HammerFUZE HAMMERTOE COMPRESSION SYSTEM SURGICAL TECHNIQUE

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

Acu-Loc Wrist Spanning Plate System. Surgical Technique

The Flower Proximal Humerus Plate

Olecranon Osteotomy Nail. For simple fractures and osteotomies of the olecranon.

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Surgical Technique. Proximal Humerus Locking Plate

3.5 mm LCP Extra-articular Distal Humerus Plate

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

DYNAMIC, TRANSVERSE COMPRESSION. Low Profile, Anatomic Design, Type II Anodized. Mechanical Compression Designed to Stimulate the Fusion Process

Lapidus Arthrodesis System Instructions for Use

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

Arthrex Open Wedge Osteotomy Technique Designed in conjunction with:

Cannulated Angled Blade Plate 3.5 and 4.5, 90.

The Flower Four Corner Fusion Plate

Surgical Technique. Customer Service:

Surgical Technique. Clavicle Locking Plate

CHARLOTTE. 3.0 and 4.3 Multi-Use Compression Screws SURGIC A L T ECHNIQUE

3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments

MICA. Minimally Invasive Foot Surgery CHEVRON OSTEOTOMY SURGIC AL TECHNIQUE

OptiLock Periarticular Plating System For Distal Tibial Fractures. Surgical Technique

CANNULINK. Intraossous Fixation System SURGICAL TECHNIQUE

Surgical Technique Carpal Fusion

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Conventus CAGE PH Surgical Techniques

Technique Guide Hammertoe Correction System

Anchorage. Foot & Ankle. Plating System. Operative Technique

Tension Band Pin System 2. Surgical Technique

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide Small Bone Fusion System

Surgical Technique 4.5/8.5MM BEAMING SYSTEM. Customer Service:

CHARLOTTE Lisfranc. Recontruction System SURGICAL TECHNIQUE

Surgical Technique. Tension Band Pin System

CHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE

AcUMEDr. FoREARM ROD SYSTEM

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

Technique Guide Lapidus Arthrodesis System

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

ANATOMIC LOCKED PLATING SYSTEM

Forearm Fracture Solutions. Surgical Technique

ORTHOLOC 3Di. Foot Reconstruction System SURGIC AL TECHNIQUE

3.5 mm Locking Attachment Plate

Surgical Technique. Lower Extremity Plates and Straight Plates

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

SMV Scientific Bone Plate and Screw System Surgical Technique

Surgical Technique International Version. Clavicle Locking Plate

Zimmer Small Fragment Universal Locking System. Surgical Technique

AcUMEDr. Olecranon Threaded Compression Rod

3.5 mm LCP Olecranon Plates

MIS Cemented Tibial Component

PediLoc 3.5mm and 4.5mm Bowed Femur Plate Surgical Technique

upper extremity fixation system

Surgical Technique. Calcaneal Locking Plate

CHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

WINSTA-C. Clavicle Plating System

Transcription:

Re+Line Bunion Correction System Surgical Technique

Bunion Correction System Easy insertion and medial placement accuracy using Landmark Guide technology Greater and repeatable uniform compression across osteotomy site Stable Fixation of the Metatarsal Head Reduces Soft Tissue Disruption Greater Fusion Surface Area Landmark Positioning Drill Guide 6.0mm Re+Line Bunion Correction Plate 1 mm Compression Slot Two-Screw Fixation Low Profile, 1 mm Skeletonized for Blood Vessel Development Alternating Side Teeth on Tines for Anchoring and Even Load Distribution Conventional Chevron Osteotomy Compatible - Eliminates Retraining 1

15mm Bunion Correction System Re+Line Bunion Correction System Sterile Procedure Kit Sterile, OR-ready instrument and implant systems Designed for repeatable outcomes Single use, optimized for OR efficiency Each kit contains one two-screw Re+Line Bunion Correction Plate The Re+Line Bunion Correction System is manufactured using 316 Stainless Steel. 10mm 15.0mm x 6.0mm 6mm 20mm 15mm 25.0mm x 8.0mm 25mm 8mm 15mm T7 Driver 20.0mm x 6.0mm 6mm Screw (available separately in 6 sizes) Temporary Pin Landmark Positioning Drill Guide 6.0mm 1.4mm AO Drill 2.0mm AO Drill 2

Surgical Technique - Chevron 1. Sizing the Implant Prior to surgery, assess pre-op x-ray to determine implant size. The size of the Re+Line implant is determined by the width of the resected metatarsal head and the length of the flattened metatarsal shaft. The Re+Line implant works most effectively when placed on a flat medial surface after correction and secondary trimming. The length of the medial flat surface will vary case-by-case, but generally the greater the correction of the capital fragment, the greater the need for a longer Re+Line implant. As long as the metatarsal head medial lateral width is wider than 15 mm, a 20 or 25 mm implant should be used. The length of the resected metatarsal shaft determines between the 20 and 25 mm implant. The 20 and 25 mm Re+Line Bunion Correction Plates are more commonly used. 2. Prepare osteotomy site. Resect medial eminence mass as required. Note: To reconfirm implant length, use a surgical metric from center of metatarsal head to desired proximal fixation point. 3. After assessing the size of the metatarsal head and deformity, open the appropriate size Re+Line Kit. Center the Landmark Positioning Guide on the medial side of the metatarsal head using the apex Landmark (laser ring) as a guide. 4. Pin the Landmark Positioning Guide to the metatarsal, proximal to the osteotomy cuts. Drill the pin to stabilize the Landmark Positioning Guide against the metatarsal. Note: Fluoroscopy may be used to ensure placement. The Landmark Positioning Guide functions as a template for the implant. 3

5. Using the 1.4 mm AO drill the three remaining holes on the Landmark Positioning Guide bushings. Note: When drilling for the tines, drill to the laser marking depth line on the AO drill. When drilling the apex hole, drill through the medial surface. Tine hole depth is 15mm when the groove is at the top of the Landmark Positioning Guide bushing. 6. (Optional) Mark the cutting landmark points on the metatarsal. Angle is 60 degrees between pen notches and apex hole. 60 7. Remove the pin used to stabilize the Landmark Positioning Guide. Cut the Chevron osteotomy and translate. Translate the head in a lateral direction to the desired position. 8. Resect medial prominence off the metatarsal. The medial surface of the resected medial metatarsal head and metatarsal shaft should be level for proper seating of the Re+Line Bunion Correction Plate. In order to prevent the head from moving, a distal to proximal K-Wire, inserted dorsally, may be used at this point to stabilize while cutting the redundant medial bone on the shaft. 4

9. Insert the Re+Line Bunion Correction Plate as far as possible into the pre-drilled holes on the medial surface of the metatarsal head. In hard bone, over-drilling the tines may be necessary. 10. While ensuring full reduction of the metatarsal head, maintain compression of the head at the osteotomy site on the metatarsal shaft. The Re+Line Bunion Correction Plate should rest as flush against the metatarsal as possible. Note: Fluoroscopy may be used prior to releasing plate to ensure proper placement. 11. Using the 2 mm AO drill, drill through the proximal end of the compression slot. Ensure the 2 mm pilot hole is made as proximal as possible to the center of the slot. This will ensure proper linear compression and thus reduction of the two bone fragments. With the drill tip crossing the lateral cortex, read the length marking that corresponds to the medial surface of the Re+Line Bunion Correction Plate to select the appropriate screw length. Once accurate screw sizing is chosen, place the screw and tighten, reducing bone fragments. Note: Ensure screws achieve bicortical bone purchase. 12. Using the 2 mm AO drill, drill the second hole in the center of the plate; this is not for compression. After this drill hole is made and the proximal compression hole has been screwed and tightened, then insert second screw and tighten. Verify reduction, close in the usual manner. 5

Alternative Surgical Technique - Other Osteotomies With planning, the Re+Line Bunion Correction Plate can be used with other osteotomies, including Long Arm Chevrons, Reverdin Laird, Large Correction Chevron (i.e. greater than 5 mm) to allow sufficient bone in the proximal fragment for each screw. 1. Create your osteotomy site and resect medial eminence. 2. Mark and create your osteotomy and translate. Resect medial prominence off the metatarsal. The medial surface of the resected medial metatarsal head and metatarsal shaft should be level for proper seating of the Re+Line Bunion Correction Plate. In order to prevent the head from moving, a distal to proximal K-Wire, inserted dorsally, may be used at this point to stabilize while cutting the redundant medial bone on the shaft. After assessing the size of the metatarsal head and deformity, open the appropriate size Re+Line Kit. Center the Landmark Positioning Guide on the medial side of the metatarsal head using the apex Landmark (laser ring) as a guide. Long Arm Chevron Reverdin Laird 3. Pin the Landmark Positioning Guide to the metatarsal, proximal to the osteotomy cuts. Drill the pin to stabilize the Landmark Positioning Guide against the metatarsal. Using the AO 1.4 mm, only drill the two Landmark Positioning Guide bushings. Note: When performing angular correction osteotomies, the medial surface should be made planar prior to drilling the tine holes. When drilling for the tines, drill to the laser marking depth line on the AO drill. When drilling the apex hole, drill through the medial surface. Tine hole depth is 15mm when the groove is at the top of the Landmark Positioning Guide bushing. 4. To place Re+Line Bunion Correction Plate, refer to steps 9-12 in Chevron technique. 6

Bunion Correction System Re+Line Bunion Correction System Sterile Procedure Kit Re+Line Bunion Correction Plate T7 Driver Landmark Positioning Drill Guide 6.0mm Re+Line Screw (available separately in 6 sizes) Temporary Pin 1.4mm AO Drill 2.0mm AO Drill Part No. RS-15610K RS-20615K RS-25815K RS-2710 RS-2712 RS-2714 RS-2716 RS-2718 RS-2720 ORDERING INFORMATION Description Re+Line Bunion Correction System Sterile Procedure Kit Re+Line Bunion Correction Plate (15mm x 6mm compression plate, two screw), Landmark Positioning Drill Guide 6mm, 1.4mm / 2mm AO Drill, Temporary Pin, Driver Re+Line Bunion Correction System Sterile Procedure Kit Re+Line Bunion Correction Plate (20mm x 6mm compression plate, two screw), Landmark Positioning Drill Guide 6mm, 1.4mm / 2mm AO Drill, Temporary Pin, Driver Re+Line Bunion Correction System Sterile Procedure Kit Re+Line Bunion Correction Plate (25mm x 8mm compression plate, two screw), Landmark Positioning Drill Guide 8mm, 1.4mm / 2mm AO Drill, Temporary Pin, Driver Re+Line 2.7mm x 10mm Compression Screw Re+Line 2.7mm x 12mm Compression Screw Re+Line 2.7mm x 14mm Compression Screw Re+Line 2.7mm x 16mm Compression Screw Re+Line 2.7mm x 18mm Compression Screw Re+Line 2.7mm x 20mm Compression Screw This surgical technique guide provides a recommended procedure for using Re+Line Bunion Correction System. The content provided puts forth technique guidance, however, the surgeon must consider the individual needs of the patient making appropriate adjustments when and as required. Nextremity Solutions, Re+Line and Landmark are trademarks of Nextremity Solutions, Inc. Zimmer Biomet is the exclusive distributor of the Re+Line Bunion Correction System. The Re+Line Bunion Correction System is manufactured using 316 Stainless Steel. Patented. 2017 Nextremity Solutions LIT-1495 Rev.10 Manufactured by: 210 N. Buffalo St. Warsaw, IN 46580 U.S.A. (732) 383-7901 nextremitysolutions.com Distributed by: 1800 West Center St. Warsaw, Indiana 46580 USA (800) 613-6131 contactus@zimmerbiomet.com