Contributors to this Talk

Similar documents
Page 1. Helical (Spiral) Tomotherapy. UW Helical Tomotherapy Unit. Helical (Spiral) Tomotherapy. MVCT of an Anesthetized Dog with a Sinus Tumor

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

Financial Disclosure. The Future of Radiotherapy. Somatic Mutations and Cancer

biij Initial experience in treating lung cancer with helical tomotherapy

Helical Tomotherapy Experience. TomoTherapy Whole Brain Head & Neck Prostate Lung Summary. HI-ART TomoTherapy System. HI-ART TomoTherapy System

Helical Tomotherapy: An Innovative Technology and Approach to Radiation Therapy

Quality Assurance of Helical Tomotherapy Machines

Advances in Radiotherapy

Implementation of advanced RT Techniques

EORTC Member Facility Questionnaire

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

Helical tomotherapy radiation leakage and shielding considerations

Introduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy

I. Equipments for external beam radiotherapy

Applications of Modern Radiotherapy Systems

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Overview of Advanced Techniques in Radiation Therapy

Helical Tomotherapy Research in London, Ontario. A Cancer Care Ontario Partner

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Intensity Modulated RadioTherapy

SRS Uncertainty: Linac and CyberKnife Uncertainties

Intensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Accuray Radixact at University of WI: The next chapter in TomoTherapy innovation

TomoTherapy. Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA. May 2016

Additional Questions for Review 2D & 3D

Dose prescription, reporting and recording in intensity-modulated radiation therapy: a digest of the ICRU Report 83

Independent Dose Verification for IMRT Using Monte Carlo. C-M M Charlie Ma, Ph.D. Department of Radiation Oncology FCCC, Philadelphia, PA 19111, USA

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

The Radixact System Experience at Miami Cancer Institute. Tino Romaguera, D.Sc. Senior Physicist

Chapters from Clinical Oncology

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Limits of Precision and Accuracy of Radiation Delivery Systems

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

Managing the imaging dose during image-guided radiation therapy

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

Pre-treatment and in-vivo dosimetry of Helical Tomotherapy treatment plans using the Dosimetry Check system

Credentialing for the Use of IGRT in Clinical Trials

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

Image Guided in Radiation Therapy (IGRT) Chumpot Kakanaporn Med Phys Radiation Oncology Siriraj Hospital

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

In-Room Radiographic Imaging for Localization

Unrivaled, End-to-End

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Flattening Filter Free beam

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

In-Room Radiographic Imaging for Localization

ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 10, NUMBER 3, Summer 2009

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Work partially supported by VisionRT

Tomotherapy as a tool in image-guided radiation therapy (IGRT): theoretical and technological aspects

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

Many vendors are beginning to allow couch motion during radiation delivery.

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies

Elekta - a partner and world-leading supplier

IMRT for Prostate Cancer

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Small field diode dosimetry

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

Image Guided Stereotactic Radiotherapy of the Lung

Eric E. Klein, Ph.D. Chair of TG-142

Potential benefits of intensity-modulated proton therapy in head and neck cancer van de Water, Tara Arpana

First, how does radiation work?

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Managing the imaging dose during Image-guided Radiotherapy. Martin J Murphy PhD Department of Radiation Oncology Virginia Commonwealth University

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer

Monte Carlo Dose Calculation for Radiotherapy Treatment Planning

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Image Registration for Radiation Therapy Applications: Part 2: In-room Volumetric Imaging

Leila E. A. Nichol Royal Surrey County Hospital

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

Planning Optimization of Conformal Radiotherapy Techniques for Meningioma Brain Tumors

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

Head and Neck Treatment Planning: A Comparative Review of Static Field IMRT RapidArc TomoTherapy HD. Barbara Agrimson, BS RT(T)(R), CMD

8/3/2016. Outline. Site Specific IGRT Considerations for Clinical Imaging Protocols. Krishni Wijesooriya, PhD University of Virginia

Comparison of TLD dose and reconstructed dose for post-mastectomy radiation therapy with TomoTherapy

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

IMAGE-GUIDED RADIATION THERAPY

Transcription:

Tomotherapy Thomas Rockwell Mackie Tomotherapy Research Group Depts. Of Medical Physics, Human Oncology and Biomedical Engineering University of Wisconsin Madison WI 53706 Phone: (608) 262-7358 Email: trmackie@facstaff.wisc.edu Web: www.madrad.radiology.wisc.edu

Contributors to this Talk Gustavo Olivera Paul Reckwerdt Jeff Kapatoes Ken Ruchala John Balog Richard Schmidt Ed Fitchard Dave Pearson Eric Schloesser Ray MacDonald Robert Jeraj Minesh Mehta Mark Ritter Jack Fowler Harry Keller Weiguo Lu Jeni Smilowitz Wolfgang Tomé Rufus Scrimger Lisa Forrest

Financial Disclosure In addition to a University of Wisconsin Professor, I am a co-founder of TomoTherapy Inc. (Middleton WI) which is participating in the commercial development of helical tomotherapy. TomoTherapy s 1,400 m 2 Middleton facility. www.tomotherapy.com

Outline Optimization Æ IMRT Æ Conformal Dose Distributions Sequential (or Serial) Tomotherapy (NOMOS Peacock ) Clinical Helical Tomotherapy Unit Dosimetry of Helical Tomotherapy Examples of Tomotherapy Dose Distributions Megavoltage Computed Tomography (MVCT) Adaptive Radiotherapy Clinical Implications

Optimization Æ IMRT Æ Conformal Dose Distributions Anders Brahme first showed that intensity modulated fields of radiation would lead to more conformal dose distributions that would spare normal tissue.

IMRT Using Conventional MLC s Siemens Varian Elekta

Sequential Tomotherapy The First Form of IMRT NOMOS Peacock System X-Ray Beam Binary MLC Leaves Binary Multileaf Collimator Courtesy: NOMOS Corporation Simulated Annealing Optimization

MIMiC Individual leaf controls opening Multileaf Intensity Modulating Collimator From Bruce Curran, NOMOS

68 Gy 60 Gy 50 Gy 30 Gy Bi-Lateral 3D-CRT From Bruce Curran, NOMOS

85Gy 70Gy 60Gy 50Gy 30Gy 7-Field IMRT (Planned with Corvus) Sequential Tomotherapy (Nomos Peacock) From Bruce Curran, NOMOS

120 GTV Dose Volume Histogram 100 80 Volume (%) 60 40 GTV_Corvus GTV_Peacock GTV_3DCRT GTV_Bilateral 20 0 0 20 40 60 80 100 Dose (Gy) From Bruce Curran, NOMOS

120 100 80 Chiasm Dose Volume Histogram Chiasm_Corvus Chiasm_Peacock Chiasm_3DCRT Chiasm_Bilateral Volume (%) 60 40 20 0 0 20 40 60 80 100 120 Dose (Gy) From Bruce Curran, NOMOS

120 100 80 Brain stem Dose Volume Histogram Stem_Corvus Stem_Peacock Stem_3DCRT Stem_Bilateral Volume (%) 60 40 20 0 0 20 40 60 80 100 Dose (Gy) From Bruce Curran, NOMOS

120 100 80 Parotid Dose Volume Histogram Parotid_Corvus Parotid_Peacock Parotid _3DCRT Parotid_Bilateral Volume (%) 60 40 20 0 0 20 40 60 80 100 Dose (Gy) From Bruce Curran, NOMOS

Role of Beam Configuration All results for 7 beam directions except where otherwise noted. Detailed dependency upo the number of beam directions shown in the nex table.

Dependency Upon Number of Beam Directions Number of Beam Directions Objective Function Value Standard Deviation in the Target Dose Minimum Dose Covering 90% of the Target (1.0=max) Mean Dose to the Region at Risk Total Integral Dose 3 0.665 0.124 0.747 0.488 2733 5 0.318 0.090 0.814 0.215 2564 7 0.242 0.064 0.867 0.206 2597 9 0.222 0.064 0.855 0.192 2599 11 0.202 0.058 0.879 0.186 2570 15 0.187 0.053 0.908 0.180 2542 21 0.176 0.049 0.912 0.171 2545 33 0.151 0.038 0.933 0.155 2544

Nasopharyngeal Example In this case the primary goal was to avoid the parotid and spinal cord. With the same amount of avoidance, the 45 angle delivery (tomotherapy) provided a more homogeneous delivery.

Re-Engineering Radiotherapy Equipment and processes re-engineered for IMRT Integration of planning, delivery and verification Better leaf resolution Simple MLC s More beam directions Single energy photon beam Better primary shielding Tomographic verification Helical tomotherapy was the result

Linac Ring Gantry Helical (Spiral) Tomotherapy CT Detector CT Couch Helical Fan Beam Helical Scanning

Animation of Helical Delivery

64 Leaf Binary MLC Close-Up

Movie Clips of the MLC Being Tested Close-Up

UW Clinical Helical Tomotherapy Unit Siemens Linac Siemens RF System GE CT Detector GE Gantry May 2000 at UW Physical Sciences Laboratory, Stoughton WI

Siemens 6 MV Linac System Linac and Gun Control RF System

Clinical Installation Finished January 16, 2001 at UW Radiotherapy Clinic

Major Specifications 6 MV Siemens linac Up to 8 Gy/min @ axis 85 cm diameter gantry bore 64 leaves with 6.25 mm resolution @ axis 4 cm x 40 cm maximum field @ axis Slice field width from 5 mm to 40 mm @ axis Minimum beamlet size 5 mm x 6.25 mm @ axis Xenon CT detectors with per pulse acquisition 0.25 mm precision CT couch Leaves 10 cm thick, 95% tungsten alloy Primary collimator 22 cm thick 95% tungsten alloy

Fan Beam Characteristics The fan field width along the longitudinal direction is continuous from 5 mm to 50 mm. There is no field flattening filter in the beam and so the beam has a higher intensity along the center as compared to either end. The beam without filtration is like the output from a CT Bowtie Filter. Image Digitized from Kodak XV Film 1 cm 40 cm

Profile Along Length of a 1 cm Wide Fan Beam Transverse Profile 120 100 Dose (%) 80 60 40 20 0-240 -180-120 -60 0 60 120 180 240 Distance (mm)

Monte Carlo Model of the Treatment Head Electron Beam from the Accelerator Target Electron Stopper Beam Hardener Monitor Chamber Primary Collimator and Jaws

Photon Spectrum 1.0 0.8 Tomotherapy (6MV) 2100 Clinac (6MV, Stanford) Spectrum [%] 0.6 0.4 0.2 0.0 0 1 2 3 4 5 6 Energy [MeV] Clinac 2100 Monte Carlo data courtesy o Dr. Charlie Ma For the same incident energy, tomotherapy has a harder spectrum due to its beam hardener and absence of a field flattening filter.

Off-Axis Energy Dependence Photon spectrum 0.040 0.035 0.030 0.025 0.020 0.015 0.010 0-5 cm 5-10 cm 10-15 cm 15-20 cm Photon spectrum 0.01 1E-3 0-5 cm 5-10 cm 10-15 cm 15-20 cm 0.005 0.000 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 Energy [MeV] Energy [MeV] Tomotherapy has no off axis hardening because of no flattening filte

Simplicity of Tomotherapy Tomotherapy Designed for Image-Guided IMRT Single Photon Energy Simple MLC No Collimator Rotation No Couch Rotation Simple CT Detector System Integration Conventional RT Designed for Conventional RT Processes Dual Mode Multiple Energy Complex MLC Collimator Rotation One or Two Axes of Couch Rotation 2D Electronic Portal Imager Multi-Component Integration

Conventional Plan to Treat Lung Cancer 98 % 70 % 50 % 40 % 20 % Tumor Spinal Cord

Tomotherapy Plan to Treat Lung Cancer 80 % 70 % 50 % 40 % 20 % Tumor Spinal Cord

Tomotherapy Decreases Mean Dose to Spinal Cord 5 0 25 20 3D plans Conventional 3D Tomotherapy Tomotherapy 5Dose (Gy) 15 10 5 0 0 P1 P2 P3 P4 P5 1 2 3 4 5 Mean Patient Case

Prostate Carcinoma Dose Rate Cumulative Dose 0 to 30% 30 to 90% 90 to 100%

Percentage of Rectal Volume Receiving High Doses 25 % of volume exceeding stated dose 20 15 10 >60 G >70 G 5 0 Conventional 3D Conventional 3D Tomotherapy Tomotherapy

Breast Carcinoma Case: Tomotherapy Movie Dose Rate Cumulative Dose Contr. breast Right lung IMC nodes Spine Tumor Heart Left lung ROI slice 47 0 to 30% 30 to 90% 90% or higher

Tomotherapy for GBM Treatments Isodose Lines 100% 90% 80% 50% Targets GTV Hypoxic Proliferative

Tomotherapy for GBM Treatments Dose Rate Cumulative Dose 0 to 50 % 50 to 75% 75 to 85 % 95 to 100% 85 to 95 %

Mesothelioma ROI slice 27 Dose Rate Cumulative Dose

Tomotherapy Dose Distributions Slice 27 Slice 31 Slice 36 50 % 80 % 90 % 50 % 80 % 90 % 50 % 80 % 90 %

3-D Imaging Adaptive Radiotherapy Optimized Planning Deformable Dose Registration Dose Reconstruction Treatment With Delivery Verification MV CT + Image Fusion Delivery Modification

Why CT Before Delivery is Necessary CT Images Acquired Daily The slices were rotated and translated to align the bony anatomy as best as possible. Original CTV Courtesy Di Yan and Marcel Van Herk

Interfraction Movement of the Breast Electronic portal image of the breast treated using a compensator. Each frame is a different day. From Dr. Jason Sohn Mallinckrodt Institute

MVCT of CIRS Phantom 0.2% 4.3% -2.4% -54.1% 5.2% 11.7% -4.8% -81.0% 51.2% 7 cgy 3.5 cgy 1.75 cgy

MVCT of RMI Phantom 1.50 mm 1.25 mm 1.00 mm 0.8 mm 1.50 mm 1.25 mm 1.00 mm 0.8 mm

MVCT Calibration Curve Image Density Electron density (red), physical density (violet)

Rando Phantom Megavoltage CT (MVCT) Head Pelvis

Rando Phantom MVCT Slice-by-Slice Traversal Through Volume Dose for Scan = 3 cgy Dose for Scan = 5 cgy

Automated Fusion of kv and MV CT Sets

Fusing Prostate CT s Acquired on Two Different Days X-offset= 4.20 cm Y-offset= 4.20 cm Z-offset= 2.60 cm Roll-offset= 32.50 deg Pitch- offset= 8.90 deg Yaw- offset= 14.70 deg

3-D Imaging Adaptive Radiotherapy Optimized Planning Deformable Dose Registration Dose Reconstruction Helical Tomotherapy MV CT + Image Fusion Delivery Modification

Delivery Modification There are two potential ways to adjust the patient setup: Adjust the patient. Adjust the beams. It may be easier and more reliable to move the beams to the patient. It may be possible in tomotherapy to alter the leaf delivery pattern.

Optimized 50 % 80 % 95 % Delivery Modified 50 % 80 % 95 % 1.42 cm offset 1cm x-offset 1cm y-offset

3-D Imaging Adaptive Radiotherapy Optimized Planning Deformable Dose Registration Dose Reconstruction Helical Tomotherapy MV CT + Image Fusion Delivery Modification

Dose Reconstruction Dose reconstruction uses transmission data acquired during treatment and the megavoltage CT to determine the dose distribution delivered that day. Dose reconstruction provides a way to directly compare the plan with the result.

Example of Dose Reconstruction ROI s (slice 29) MV CT (slice 29) L. eye Target R. eye Brain 8.5 deg. Shift

Dose Reconstructed Using MV CT The reconstructed dose reveals that the dose distribution is rotated toward the left eye and underdosing the target volume. Optimized Reconstructed

3-D Imaging Adaptive Radiotherapy Optimized Planning Deformable Dose Registration Dose Reconstruction Helical Tomotherapy MV CT + Image Fusion Delivery Modification

Deformable Dose Registration Deformable dose registration uses a mechanical deformation model along with matched contours and points from two image sets to register them. Deformable dose registration allows the dose from each fraction to be added up properly.

3-D Imaging Adaptive Radiotherapy Optimized Planning Deformable Dose Registration Dose Reconstruction Helical Tomotherapy MV CT + Image Fusion Delivery Modification

Image of Regret Adapted Dose Distribution 0 to 3 mm(%) 6 to 9 mm(%) 3 to 6 mm(%) 9 to 12 mm(%) Dose to deliver to correct regret.

Incorrect +Perfect Non - Adapted Incorrect +Corrected Adapted 0 to 3 mm(%) 6 to 9 mm(%) 3 to 6 mm(%) 9 to 12 mm(%) 0 to 3 mm(%) 6 to 9 mm(%) 3 to 6 mm(%) 9 to 12 mm(%)

Clinical Implications More complex target volumes can be delivered and still spare critical volumes. Complex prescriptions or dose painting. Higher dose/fraction can be delivered to the tumor and still have low dose and dose/fraction to critical tissues. Conformal avoidance. More accurate setup of the patient. Better verification that delivery is correct. Have a basis to repair dose distributions. Adaptive radiotherapy.

Other Innovative Treatments Tomotherapy Will Enable Stereotactic radiotherapy (and radiosurgery) to the body. Irradiate entire nodal chains with conformal avoidance. Repairing the dose distributions from other modalities, e.g., poor seed implants. Combined brachytherapy and IMRT. Bone marrow ablation while sparing visceral organs. Whole-skin irradiation using IMRT. Probability-based prophylactic radiotherapy. Swiss-cheese-like dose distributions in normal tissue (3-D grid therapy). Great change in breast radiotherapy.

Increased Throughput Possible Integration of planning, delivery and verification. Potentially easier to commission and calibrate. Dose reconstruction eliminates need for on-going patient-specific dosimetry measurements. Fewer planning decisions and optimization may be automated. High dose rate (8 Gy/min). Higher dose/fraction more feasible because normal tissue can be more easily avoided. Easier patient setup. No couch rotation reducing possibility of collision. Tomographic verification images are more easy to interpret than planar portal images. Impact of delivery errors can be reduced. Increased primary collimation so less staff irradiation per patient.

Conclusions Helical tomotherapy is the marriage of a linac with a CT scanner. Helical tomotherapy can deliver highly conformal dose distributions. Megavoltage CT is sufficient for verification of the setup. Dose reconstruction and deformable registration determines the dose actually delivered. Adaptive radiotherapy ensures that the whole course of therapy is delivered correctly. Tomotherapy provides image-guidance for the whole chain of radiotherapy processes.