Fracture Fixation The following languages are included in this packet:

Similar documents
DARCO MIS FOREFOOT SCREW

CLAW II POLYAXIAL COMPRESSION PLATING SYSTEM

The following languages are included in this packet:

EVOLVE TRIAD SYSTEM

MICA SCREWS For additional information and translations please contact the manufacturer or local distributor.

ORTHOLOC 3Di PLANTAR LAPIDUS PLATE

BIOFOAM BONE WEDGE

Metallic Internal Fixation Devices The following languages are included in this packet:

EXTERNAL FIXATION SYSTEMS The following languages are included in this packet:

STABILIZATION AND FRACTURE FIXATION

EVOLVE TRIAD BONE SCREWS

SIDEKICK EZ FRAME EXTERNAL FIXATION SYSTEM The following languages are included in this packet:

DARCO HEADED CANNULATED SCREWS

METATARSAL DECOMPRESSION IMPLANT (MDI) SYSTEM

ENDO-FUSE INTRA-OSSEOUS FUSION SYSTEM The following languages are included in this packet:

METAL HEMI SYSTEM

ORTHOLOC 3Di ANKLE FUSION PLATING SYSTEM

SALVATION EXTERNAL FIXATION SYSTEM

SALVATION EXTERNAL FIXATION SYSTEM

The following languages are included in this packet:

CANNULATED SCREW SYSTEM The following languages are included in this packet:

PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

CELLPLEX TCP SYNTHETIC CANCELLOUS BONE

CHARLOTTE. 3.0 and 4.3 Multi-Use Compression Screws SURGIC A L T ECHNIQUE

CHARLOTTE. Compression Staple SURGIC A L T ECHNIQUE

PRO-DENSE BONE GRAFT SUBSTITUTE

Lapidus Arthrodesis System Instructions for Use

BIOARCH SUBTALAR IMPLANT SYSTEM

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

CHARLOTTE Lisfranc. Recontruction System SURGICAL TECHNIQUE

INVISION TOTAL ANKLE REVISION SYSTEM The following languages are included in this packet:

BIOFOAM ANKLE SPACER BLOCK

TOTAL ELBOW SYSTEM The following languages are included in this packet:

Technique Guide Small Bone Fusion System

SJO SILICONE IMPLANTS The following languages are included in this packet:

TOTAL ANKLE SYSTEMS

Technique Guide Lapidus Arthrodesis System

Technique Guide KISSloc Suture System

MICA. Minimally Invasive Foot Surgery CHEVRON OSTEOTOMY SURGIC AL TECHNIQUE

SpeedTip CCS 2.2, 3.0

Integra. ADVANSYS Plating System SURGICAL TECHNIQUE

FUSEFORCE. Hand Fixation System SURGICAL TECHNIQUE

MICROPORT KNEE SYSTEMS The following languages are included in this packet:

ORTHOLOC 3Di. Foot Reconstruction System SURGIC AL TECHNIQUE

Implantable K-wire SURGIC A L T ECHNIQUE

ORTHOLOC CROSSCHECK TECHNOLOGY OVERVIEW FOR HOSPITAL VALUE ANALYSIS COMMITTEE

Variable Angle LCP Forefoot/Midfoot System 2.4/2.7. Procedure specific plates for osteotomies, arthrodeses and fractures of the foot.

Integra Total Foot System 2

SWANSON. Hammertoe Implant SURGICAL TECHNIQUE

Precautionary Statement ( )

For use by an Accredited Orthopaedic Surgeon only

Ratcheting Compression Plating System. Surgical Technique

Telya. Varisation staple. Surgical Technique. Irish Distributer: O'Mara Medical Tel

Page 1 of 7 Doc. No.: IU/15 Rev. No.: 05 Rev. Date:03MAY2018. Instructions for use for ATLAS Tibial Fracture(TF) Nail

Integra. surgical technique. Advansys Midfoot Plating System. eng. D.L.P. Dorsal Lisfranc Plate. M.L.P. Medial Lisfranc Plate

Revision A Date:

Technique Guide Hammertoe Correction System

LBL-014. Rev

DRACO FOOT & ANKLE SYSTEM PRODUCT INFORMATION

Use of the 20 Memory Staple in Osteotomies of Fusions of the Forefoot

LOWER EXTREMITIES SINGLE-USE INSTRUMENTATION SURGICAL IMPLANTATION TECHNIQUE. First Metatarsal Phalangeal Joint FOOT THE DIFFERENCE IS MOVING.

Important Information on ATLAS Hip Fracture Nail For use by an Accredited Orthopaedic Surgeon only

PL ATING SYSTEM. Pre-contoured implants Versatile fixation system Hexalobe screw recess design Locked fixation

Compression Screw 3.2 Bioabsorbable. Product information

WristMotion Wrist Hemiarthroplasty System Instructions for Use

SALVATION 3Di. Plating System SURGICAL TECHNIQUE

Technique Guide. 6.5 mm Midfoot Fusion Bolt. For intramedullary fixation of the medial column of the foot.

Talar Dome System Surgical Technique

ORTHOLOC 3Di. Foot Reconstruction System Midfoot Fusion Plate SURGICAL TECHNIQUE

SURGICAL TECHNIQUE. Compression screw FOREFOOT SOLUTIONS

SURGICAL TECHNIQUE GUIDE

Technique Guide Wrist Hemiarthroplasty System

Knee spanning solutions

The Flower Medial Column Fusion Plate

MetaFix Ludloff Plate

SWANSON. Flexible Hinge Toe Implant SURGIC AL TECHNIQUE

ALLOPURE. Bicortical Allograft Wedges Specific for Evans and Cotton Osteotomies SURGICAL TECHNIQUE

AcUMEDr. AcUTRAKr. Headless Compression Screw

DARCO. Bow 2 Plate SURGIC AL TECHNIQUE

ADVANSYS Midfoot plating system

IMPORTANT MEDICAL INFORMATION Advanced Orthopaedic Solutions INTRAMEDULLARY NAILS Warnings and Precautions (SINGLE USE ONLY)

Flower Medium Headless & Cannulated Screws

RibLoc U Plus CHEST WALL PLATING SYSTEM FOR THE PERSONAL ATTENTION OF THE OPERATING SURGEON

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

DYNAMIC, TRANSVERSE COMPRESSION. Low Profile, Anatomic Design, Type II Anodized. Mechanical Compression Designed to Stimulate the Fusion Process

Hallux Valgus Deformity OPERATIVE TECHNIQUE

CHARLOTTE. Snap-Off Screws SURGICAL TECHNIQUE

DISTAL RADIUS. Instructions for Use

TTA Wedge System INSTRUCTIONS FOR USE

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

Flower Opening Wedge Plate

Zimmer Small Fragment Universal Locking System. Surgical Technique

Indications: ATLAS HF Nail is indicated for fractures of the femur including: Contraindications:

The Flower Forefoot PROCEDURE GUIDE.

CHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE

Integra. Silicone PIP Implant SURGICAL TECHNIQUE

DISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY

Instructions for use for Bone Plates, Bone Screws, Intramedullary Nails, Pins and Wires

6.5 mm midfoot fusion bolt

Transcription:

Fracture Fixation 150846-0 The following languages are included in this packet: English (en) Deutsch (de) Nederlands (nl) Français (fr) Español (es) Italiano (it) Português (pt) 中文 - Chinese (sch) Türkçe (tk) For additional languages, visit our website www.wmt.com. Then click on the Prescribing Information option. For additional information and translations please contact the manufacturer or local distributor. M C 0086* P Wright Medical Technology, Inc. Wright Medical UK Ltd 1023 Cherry Road 3rd Avenue Memphis, TN 38117 Letchworth U.S.A. Herts, SG6 2JF. UK * the CE-Marking of Conformity is applied per catalog number and appears on the outer label, if applicable. October 2013 Printed in U.S.A 1508460.indd 1

2 1508460.indd 2

Attention Operating Surgeon IMPORTANT MEDICAL INFORMATION WRIGHT MEDICAL Fracture Fixation (150846-0) EN Outline: I. General PRODUCT Information A. PATIENT SELECTION B. CONTRAINDICATIONS C. POTENTIAL COMPLICATIONS AND ADVERSE REACTIONS D. PRECAUTIONS E. HANDLING AND STERILIZATION F. STORAGE CONDITIONS II. Specific PRODUCT Information A. LOCON-T Distal Radius Plating System B. LOCON VLS Distal Radius Plating System C. EVOLVE Radial Head Plate System D. EVOLVE EPS System E. MICRONAIL Intramedullary Distal Radius System F. CHARLOTTE MTP Bone Fusion Plate 3 1508460.indd 3

G. CHARLOTTE Multi-Use Compression Screw H. CHARLOTTE Compression Staple I. CHARLOTTE Quick Staple J. CHARLOTTE Snap-Off Screw K. CHARLOTTE Claw Plate L. CHARLOTTE 7.0 Multi-Use Compression Screw M. CHARLOTTE Carolina Jones Fracture System N. CHARLOTTE LisFranc Bone Screw O. CHARLOTTE LisFranc Plate DEFINITIONS Symbols and abbreviations may be used on the package label. The following table provides the definition of these symbols and abbreviations. Table 1. Definitions of Symbols and Abbreviations 4 Symbol g h D Definition Batch code Catalog number Do not re-use 1508460.indd 4

Y i H l p N M P[]\ I K STERILE GAS J Caution, consult accompanying documents Consult operating instructions Use by Temperature limitation Keep dry Keep away from sunlight Date of manufacture Manufacturer Authorized EC Representative in the European Community Sterilized using ethylene oxide Sterilized using radiation Sterilized using gas plasma Sterilized using aseptic processing techniques For prescription use only 5 1508460.indd 5

Abbreviation Ti Ti6Al4V CoCr SS UHMWPE Material Titanium Titanium Alloy Cobalt Chrome Alloy Stainless Steel Ultra High Molecular Weight Polyethylene 6 I. General PRODUCT Information Through the advancement of surgical fusion hardware, the surgeon has been provided a means of correcting deformity and reducing pain for many patients. While the implants used are largely successful in attaining these goals, it must be recognized that they are manufactured from metal, and that no implant can be expected to withstand the activity levels and loads as would normal, healthy bone after fusion occurs. Each patient must be evaluated by the surgeon to determine the risk/benefit relationship. In using fusion implants, the surgeon should be aware of the following: The correct selection and sizing of the implant is extremely important. Selection of the proper size, shape, and design of the implant increases the potential for success. The implants require careful seating and adequate bone support. In selecting patients for surgery, the following factors can be critical to the eventual success of the procedure: 1508460.indd 6

1. Patient s occupation or activity. If the patient is involved in an occupation or activity which includes substantial lifting or muscle strain, the resultant forces can cause failure of the fixation, the device, or both. The implant will not restore function to the level expected with normal healthy bone, and the patient should not have unrealistic functional expectations. 2. Condition of senility, mental illness, or alcoholism. These conditions, among others, may cause the patient to ignore certain necessary limitations and precautions in the use of the implant, leading to failure or other complications. 3. Foreign body sensitivity. Where material sensitivity is suspected, appropriate tests should be made prior to material selection or implantation. A. PATIENT SELECTION Use of surgical fusion hardware requires consideration of the following general indications: Good condition of the patient Good neurovascular status Adequate skin coverage Possibility of a functional musculotendinous system Adequate bone stock to receive implant Availability of post-operative therapy Cooperative patient See Section II for specific product information. 7 1508460.indd 7

8 B. CONTRAINDICATIONS Infection Physiologically or psychologically inadequate patient Inadequate skin, bone, or neurovascular status Irreparable tendon system Possibility for conservative treatment Growing patients with open epiphyses Patients with high levels of activity C. POTENTIAL COMPLICATIONS AND ADVERSE REACTIONS In any surgical procedure, the potential for complications exists. The risks and complications with these implants include: Infection or painful, swollen or inflamed implant site Fracture of the implant Loosening or dislocation of the implant requiring revision surgery Bone resorption or over-production Allergic reaction(s) to implant material(s) Untoward histological responses possibly involving macrophages and/or fibroblasts Migration of particle wear debris possibly resulting in a bodily response Embolism See Section II for specific product information. 1508460.indd 8

D. PRECAUTIONS Following the instructions for use provided in product literature can minimize the potential for complications or adverse reactions with any implant. It is the responsibility of each surgeon using implants to consider the clinical and medical status of each patient and to be knowledgeable about all aspects of implant procedure and the potential complications that may occur. The benefits derived from implant surgery may not meet the patient s expectations or may deteriorate with time, necessitating revision surgery to replace the implant or to carry out alternative procedures. Revision surgeries with implants are common. The patient s mental status must also be considered. Willingness and/or ability to follow post-operative instructions may also impact the surgical outcome. Surgeons must balance many considerations to achieve the best result in individual patients. IF EXCESSIVE LOADING CANNOT BE PREVENTED, AN IMPLANT SHOULD NOT BE USED. The main goal of surgery with this implant is to establish bony fusion. Abnormal or excessive forces could lead to delayed union, non-union, or failure of the implant. Abnormal force loading and subsequent wear may be caused by: Uncorrected instability Improperly sized implant Inadequate soft tissue support Implant malposition Excessive motion 9 1508460.indd 9

10 Uncorrected or recurrent deformity Patient misuse or overactivity Proper fixation at the time of surgery is critical to the success of the procedure. Bone stock must be adequate to support the device. Some preventative measures to consider to minimize the potential for complications: Follow guidelines for indications and contraindications provided above Identify prior pathology Stabilize collapse deformities Bone graft pre-existing cysts Use a properly sized implant Avoid K-wires and sutures through the implant Avoid flawing implant surfaces to minimize the potential for early fatigue failure. If complications develop, possible corrective procedures include: Implant removal Synovectomy Bone grafting of cysts Replacement of the implant Removal of the implant with fusion of the joint Over time, metallic implants may loosen, fracture, or cause pain after the bone fracture or osteotomy is healed. Removal of metallic implants is at the surgeon s discretion, and 1508460.indd 10

the appropriateness of the selected procedure will be based on the surgeon s personal medical training and experience. It is imperative that adequate post-operative care and protection be provided by the surgeon. Recommendations Regarding Device Fragments 1. Use medical devices in accordance with their labeled indications and the manufacturer s instructions for use, especially during insertion and removal. 2. Inspect devices prior to use for damage during shipment or storage or any out-of-box defects that might increase the likelihood of fragmentation during a procedure. 3. Inspect devices immediately upon removal from the patient for any signs of breakage or fragmentation. 4. If the device is damaged, retain it to assist with the manufacturer s analysis of the event. 5. Carefully consider and discuss with the patient (if possible) the risks and benefits of retrieving vs. leaving the fragment in the patient. 6. Advise the patient of the nature and safety of unretrieved device fragments including the following information: a. The material composition of the fragment (if known); b. The size of the fragment (if known); c. The location of the fragment; d. The potential mechanisms for injury, e.g., migration, infection; e. Procedures or treatments that should be avoided such as MRI exams in the case of metallic fragments. This may help to reduce the possibility of a serious injury from the fragment. 11 1508460.indd 11

Clinical results depend on surgeon and technique, pre-operative and post-operative care, the implant, patient pathology and daily activity. It is important that surgeons obtain appropriate informed consent and discuss the potential for complications with each patient prior to surgery. This may include a review of alternative, non-implant procedures such as soft tissue reconstruction or arthrodesis. Concerning Magnetic Resonance Environments The devices described in this package insert have not been evaluated for safety and compatibility in the MR environment. The devices described in this package insert have not been tested for heating or migration in the MR environment. See Section II for specific product information. E. HANDLING AND STERILIZATION IMPLANTS The implants in this system are either provided sterile or non-sterile; the individual product s labeling will determine whether or not it is packaged sterile. Implants that are presented in instrument trays are provided non-sterile. Implants in sterile packaging should be inspected to ensure that the packaging has not been damaged or previously opened. The implants should be opened using aseptic OR technique; they should only be opened after the correct size has been determined. Implants provided non-sterile should be processed according to the recommended parameters for instruments (below). An implant should never be re-sterilized after contact with body tissues or fluids. 12 1508460.indd 12

Devices labeled for single-use only should never be reused. Reuse of these devices may potentially result in serious patient harm. Examples of hazards related to the reuse of these devices include, but are not limited to: significant degradation in device performance, cross-infection, and contamination INSTRUMENTS Surgical instruments (and non-sterile implants) should be cleaned and sterilized according to the following parameters: Cleaning & Disinfection Clean to remove gross contamination and disinfect to reduce the number of viable microorganisms. 1. Disassemble as per manufacturer instructions (if appropriate). 2. Rinse with cold tap water to remove gross contamination. 3. Bathe in an enzymatic detergent solution prepared per manufacturer directions for 5 minutes. 4. Scrub thoroughly with a soft brush and/or pipe cleaner; repeatedly flush any very narrow lumens with enzymatic detergent solution using a syringe. 5. Rinse with cold tap water for a minimum of one minute; use a syringe to repeatedly flush any very narrow lumens. 6. Bathe in a detergent solution prepared per manufacturer directions for 5 minutes. 7. Scrub thoroughly with a soft brush and/or pipe cleaner; repeatedly flush any very narrow lumens with detergent solution using a syringe. 13 1508460.indd 13

8. Rinse thoroughly / flush with deionized / reverse osmosis (RO/DI) water. 9. Sonicate for a minimum of 10 minutes in an enzymatic detergent solution prepared per manufacturer directions. 10. Rinse thoroughly / flush with RO/DI water. 11. Dry with a clean, soft, absorbent, disposable cloth. 12. Visually inspect for cleanliness. All visible surfaces, internal and external, should be visually inspected. If necessary re-clean until it is visibly clean. Note: Brushes (i.e. pipe cleaners) could be used for cleaning most lumens, however, the use of a syringe to flush narrow lumens with diameters less than or equal to 0.041 inches is recommended. Sterilization 1. Double wrap the component in CSR wrap or a similar type non-woven medical grade wrapping material. 2. Autoclave according to the following parameters: 14 Steam Sterilization Cycle Type Parameter Minimum Set Point Exposure Temperature 270 F (132 C) Prevacuum 270 F (132 C) Exposure Time 4 minutes Dry Time 20 minutes 1508460.indd 14

3. After sterilization, remove the component from its wrapping using accepted sterile technique with powder-free gloves. Ensure that implants are at room temperature prior to implantation. Avoid contact with hard objects that may cause damage. These recommendations are consistent with AAMI ST79 Table 5 guidelines and have been developed and tested using specific equipment. Due to variations in environment and equipment, it must be demonstrated that these recommendations produce sterility in your environment. If processing conditions, wrapping materials, or equipment changes occur, the effectiveness of the sterilization process must be demonstrated. For additional information see Wright s Cleaning and Handling of Wright Medical Instruments. F. STORAGE CONDITIONS All implants must be stored in a clean, dry environment and be protected from sunlight and extremes in temperature. II. Specific PRODUCT Information A. Locon-T Distal Radius Plating System The LOCON-T Distal Radial Plating System consists of right and left dorsal bone plates, volar T-plates, cancellous screws, cortical screws, buttress pins, and a dorsal plate extender. All components are manufactured from stainless steel. 15 1508460.indd 15

INDICATIONS Use of the LOCON-T Distal Radial Plating System is intended to be used for fixation of unstable distal radial fractures in which closed reduction is not suitable: Joint destruction and/or subluxation visible on x-ray; Failed fracture fixation with or without bone graft; Osteotomy and repair of distal radius malunion with or without bone graft; Displaced or non-displaced fracture which may or may not involve angulation or fragmentation of bone; Dorsal plates are indicated for use with comminuted articular fractures, shearing fractures of the articular surface, severely comminuted extra-articular fractures, and fractures in which reduction has been lost following fixation with percutaneous pins with or without an external fixator; T-plates are indicated for use with volar articular shearing fractures. CONTRAINDICATIONS The LOCON-T Distal Radial Plating System is contraindicated for the following: In patients with probable history of infection or current infection Overt infection Skeletally immature patients 16 1508460.indd 16

B. LOCON VLS Distal Radius Plating System The Locon VLS Distal Radius Plating System consists of right and left volar bone plates, cancellous screws, and cortical screws. All components are manufactured from stainless steel. INDICATIONS Use of the Locon VLS Distal Radius Plating System is intended to be used for fixation of unstable distal radial fractures in which closed reduction is not suitable: Joint destruction and/or subluxation visible on x-ray; Failed fracture fixation with or without bone graft; Osteotomy and repair of distal radius malunion with or without bone graft; Displaced or non-displaced fracture which may or may not involve angulation or fragmentation of bone; Volar plates are indicated for use with comminuted articular fractures, shearing fractures of the articular surface, severely comminuted extra-articular fractures, and fractures in which reduction has been lost following fixation with percutaneous pins with or without an external fixator; Locking Volar plates are indicated for use with volar articular shearing fractures. 17 1508460.indd 17

CONTRAINDICATIONS The Locon VLS Distal Radius Plating System is contraindicated for the following: In patients with probable history of infection or current infection Overt infection Skeletally immature patients C. EVOLVE Radial Head Plate System The EVOLVE Radial Head Plate System consists of plates, cancellous screws, and locking screws. All components are manufactured from stainless steel. INDICATIONS Use of the EVOLVE Radial Head Plate System is intended to be used for fixation of unstable radial fractures in which closed reduction is not suitable. CONTRAINDICATIONS The EVOLVE Radial Plate System is contraindicated for the following: In patients with probable history of infection or current infection Overt infection Skeletally immature patients 18 1508460.indd 18

D. EVOLVE EPS System The EVOLVE EPS System consists of a variety of pre-contoured plate geometries. The plates feature compression slots and locking screw holes. The associated screws are available in a range of lengths. All components are manufactured from stainless steel. INDICATIONS The EVOLVE EPS System is intended for fixation of fractures, osteotomies and nonunions of the olecranon, humerus, radius and ulna. CONTRAINDICATIONS The EVOLVE EPS System is contraindicated for the following: In patients with probable history of infection or current infection Overt infection Skeletally immature patients E. MICRONAIL Intramedullary Distal Radius System The MICRONAIL Intramedullary Distal Radius System consists of Distal Radius Implants, Cortical Bone Screws, and Buttress Screws. All components are manufactured from Titanium. 19 1508460.indd 19

INDICATIONS The MICRONAIL Intramedullary Distal Radius System is intended to be used for the fixation of unstable distal radius fractures in which closed reduction is not suitable: Joint destruction and/or subluxation visible on x-ray; Failed fracture fixation with or without bone graft; Osteotomy and repair of distal radius malunion with or without bone graft; Displaced or non-displaced fracture which may or may not involve angulation or fragmentation of bone; Comminuted articular fractures, shearing fractures of the articular surface, severely comminuted extra-articular fractures, and fractures in which reduction has been lost following fixation with percutaneous pins with or without an external fixator. CONTRAINDICATIONS The MICRONAIL Intramedullary Distal Radius System is contraindicated for the following: In patients with probable history of infection or current infection Overt infection Skeletally immature patients 20 1508460.indd 20

F. CHARLOTTE MTP Bone Fusion Plate The CHARLOTTE MTP Bone Fusion Plate System consists of plates in left and right configurations and screws. All screws and plates are manufactured from stainless steel. INDICATIONS The CHARLOTTE MTP Bone Fusion Plate System is intended to help increase the rate of bony union, and to maintain the position of the toe during fusion. Once the joint has fused, the plate is secondary in the transmission of gait forces. Indications for Use: Fractures, osteotomies or arthrodesis of the first metatarsal-phalangeal joint Deformity due to hallux valgus Deformity due to arthritis in the first metatarsal-phalangeal joint Loss of motion- hallux rigidus Pain associated with osteoarthritis or rheumatoid arthritis in the first metatarsalphalangeal joint Revision procedures where other treatments or devices have failed; and Chronic instability in the first metatarsal-phalangeal joint 21 1508460.indd 21

G. CHARLOTTE Multi-Use Compression Screw The CHARLOTTE Multi-Use Compression Screw is offered in various diameters and lengths. It is offered in short and long thread lengths and has self drilling and self tapping features on both distal and proximal threads. All screws are manufactured from stainless steel. INDICATIONS The CHARLOTTE Multi-Use Compression Screw is indicated for fixation of bone fractures or for bone reconstruction. Examples include: Mono or Bi-Cortical osteotomies in the foot or hand Distal or Proximal metatarsal or metacarpal osteotomies Weil osteotomy Fusion of the first metatarsophalangeal joint and interphalangeal joint Fixation of osteotomies for Hallux Valgus treatment (such as Scarf, Chevron, etc.) Akin type osteotomy Arthrodesis base first metatarsal cuneiform joint to reposition and stabilize metatarsus varus primus Calcaneus/ cuboid arthrodesis Talar/ navicular arthrodesis 22 1508460.indd 22

H. CHARLOTTE Compression Staple The CHARLOTTE Compression Staple is offered in several sizes with barbs to prevent back out and a diamond shape slot compression feature. All staples are manufactured from stainless steel. INDICATIONS The CHARLOTTE Compression Staple is intended to be used for fixation such as: LisFranc arthrodesis, mono or bi-cortical osteotomies in the forefoot, first metatarsophalangeal arthrodesis, Akin osteotomy, midfoot and hindfoot arthrodeses or osteotomies, fixation of osteotomies for hallux valgus treatment (Scarf and Chevron), and arthrodesis of the metatarsocuneiform joint to reposition and stabilize metatarsus primus varus. I. charlotte Quick Staple The CHARLOTTE Quick Staple features barbs to prevent back out. All staples are manufactured from stainless steel. INDICATIONS The CHARLOTTE Quick Staple is intended to be used for wedge osteotomy of the first phalanx (Akin osteotomy), in the treatment of hallux-valgus in order to correct a remaining valgus or pronation of the first ray, and external rotation, and wind-swept toes. 23 1508460.indd 23

J. CHARLOTTE Snap-Off Screw The CHARLOTTE Snap-Off Screw is offered in various diameters and lengths. All screws are manufactured from titanium. INDICATIONS The CHARLOTTE Snap-Off Screw is indicated for fixation of bone fractures or for bone reconstruction. Examples include: Fixation of Small Bone Fragments Weil osteotomy Mono-cortical fixation Osteotomies and fractures fixation in the foot and hand 24 K. charlotte Claw Plate The CHARLOTTE CLAW Plate consists of plates and locking-screws in various lengths. All plates and screws are manufactured from stainless steel. INDICATIONS The CHARLOTTE CLAW Plate is intended to be used for fixation such as: LisFranc arthrodesis, mono or bi-cortical osteotomies in the forefoot, first metatarsophalangeal arthrodesis, Akin osteotomy, midfoot and hindfoot arthrodeses or osteotomies, fixation 1508460.indd 24

of osteotomies for hallux valgus treatment (Scarf and Chevron), and arthrodesis of the metatarsocuneiform joint to reposition and stabilize metatarsus primus varus. L. charlotte 7.0 mm Multi-Use Compression Screw The CHARLOTTE 7.0 mm Multi-Use Compression Screw is a self drilling screw offered in various lengths and distal thread lengths. Washers are offered for oblique and straight screw placement. All screws and washers are manufactured from stainless steel. INDICATIONS The CHARLOTTE 7.0 mm Multi-Use Compression Screw is indicated for fixation of bone fractures or for bone reconstruction. Examples include: Fixation of bone fragments, in long bones or small bones fractures Fracture management in the foot or hand Arthrodesis in hand, foot or ankle surgery Mono- or Bi-cortical osteotomies in the foot or hand or in long bones Hindfoot arthrodesis M. charlotte Carolina Jones Fracture System The CHARLOTTE Carolina Jones Fracture Screw is offered in various diameters and lengths. All screws are manufactured from stainless steel. 25 1508460.indd 25

INDICATIONS The CHARLOTTE Carolina Jones Fracture System is indicated for fixation of bone fractures or for bone reconstruction of the 5th Metatarsal. Examples include: Fixation of malunions and nonunions Acute fractures Avulsion fractures Repetitive stress fractures Jones Fractures Malleolar Fractures Talus Fractures Greater Tuberosity Fractures N. charlotte LisFranc Bone Screw The CHARLOTTE LisFranc Bone Screw is offered in various diameters and lengths. All screws are manufactured from stainless steel. INDICATIONS The CHARLOTTE LisFranc Bone Screw is intended to be used for fixation such as: LisFranc arthrodesis, first metatarsophalangeal arthrodesis, midfoot and hindfoot arthrodeses or osteotomies, fixation of osteotomies for hallux valgus treatment (Scarf 26 1508460.indd 26

and Chevron), and arthrodesis of the metatarsocuneiform joint to reposition and stabilize metatarsus primus varus. O. charlotte LisFranc Plate The CHARLOTTE LisFranc Plate consists of plates, non-locking screws, and locking screws. All components are manufactured from stainless steel. INDICATIONS The CHARLOTTE LisFranc Plate is intended to be used for fixation such as: LisFranc arthrodesis, mono or bi-cortical osteotomies in the forefoot, first metatarsophalangeal arthrodesis, Akin osteotomy, midfoot and hindfoot arthrodeses or osteotomies, fixation of osteotomies for hallux valgus treatment (Scarf and Chevron), and arthrodesis of the metatarsocuneiform joint to reposition and stabilize metatarsus primus varus. This implant should only be used with a CHARLOTTE plate and screw system. Combination with other implants or instruments is not permissible. Trademarks and Registered Trademarks are owned by Wright Medical Technology, Inc. 27 1508460.indd 27