LC-LC-GC-MS System PAH PAH Workstation

Similar documents
AS Application Note 1801

AS Application Note 1602

MOSH/MOAH Analysis Online LC/GC System with Chronect -LC/GC

GC/MS Application Note

SANCO/10616/2009 rev. 7 ( )

APPLICATION NOTE Determination of Aflatoxin M1 via FREESTYLE ThermELUTE with Online HPLC-Measurement

Regulatory changes and challenges in relation to cocoa

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

MOSH/MOAH QUESTIONS AND ANSWERS

The challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample

GC & LC Application Note

Using RP-HPLC with Fluorescence Detection and SEC C for Sample Preparation and Its Application for Different Food Samples

Application Note No. 119/2013 Determination of bisphenol A in preserved food SpeedExtractor E-916: Determination of bisphenol A in preserved food

Methods and Materials

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

Allergen Analysis : Customer Solution Case Studies. ILSI Madrid 2018 Adrian Rogers

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Analysis of bisphenol A leaching from baby feeding bottles

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

CyBio Felix Your Automated Application Starts Here

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Determination of Amantadine Residues in Chicken by LCMS-8040

Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Final. Organisations and/or individuals. 1 Association of the European Self-Medication Industry (AESGP) 2 European Herb Growers Association (EUROPAM)

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

EU Priority PAH Analysis in Pumpkin Seed Oil Using Bond Elut EMR Lipid Cleanup by GC/MS/MS

Separation of 54 PAHs on an Agilent J&W Select PAH GC Column

Thierry Faye, Agilent Technologies Jef Focant, University of Liege, Belgium

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B

Measurement of Acrylamide in Potato Chips by Portable FTIR Analyzers

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF

Axel Semrau. MOSH/MOAH Recap and new developments

Findings of the EFSA Data Collection on Polycyclic Aromatic Hydrocarbons in Food

Optimizing Chiral Separations and Purification of Enantiomers Through Selective Sample Slicing and Column Switching

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

Solutions at GE Inspection Technologies

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system

Fast Separation of EU and US EPA Regulated PAHs on Agilent J&W Select PAH GC Columns

using the Agilent 7696A Sample Prep

Analysis of mineral oil and synthetic

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Application Note. Authors. Abstract. Food

Innovations for a better world. Mixing plants. For premix and ready mix formulas.

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Improved Isolation and Analysis of Mycotoxins from Cereals, Beer and Wine

Analysis of short chain organic acids in tobacco and in some flavored e-liquids

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Vitamins and Food Contaminants by UPLC/MS/MS

Innovative method for Vitamin Analysis at point of production

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Innovations in Large Volume Injection

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

DEXAMETHASONE. First draft prepared by Bruno LE BIZEC, Nantes, France

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

Jennifer P. Pascali, PhD. dtolabs, Resana (TV)

Bisphenol A in Drinking Water

Fibertec 1023 Dietary Fibre Solutions

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

QuickSplitTM Flow Splitters

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Determination of Fusarium Mycotoxins in Wheat, Maize and Animal Feed Using an Online TurboFlow and Orbitrap LC/MS Method

ISO INTERNATIONAL STANDARD. Vegetable fats and oils Determination of cocoa butter equivalents in milk chocolate

MALAYSIAN MALAYSIAN COCOA WORKSHOP ON THE SAFE USE OF PESTICIDES IN COCOA AND HARMONIZED

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

DETERMINATION OF ACRYLAMIDE IN COFFEE AND COFFEE PRODUCTS

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

EASI-EXTRACT BIOTIN Product Code: P82 / P82B

Mycotoxin Analysis in Peanut Butter Using Captiva EMR Lipid Cleanup and LC/MS/MS

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Journal of Chemical and Pharmaceutical Research

Analysis of mycotoxins in food matrices using the Agilent Ultivo Triple Quadrupole LC/MS

1 Analytical Methods 2 3 Electronic Supplementary Information Ultra-trace determination of sodium fluoroacetate (1080) as

3-MCPD esters in edible oils: analytical aspects

European monitoring of mineral oil. The European Commission s science and knowledge service Joint Research Centre

Analysis & occurrence of bound glycidol and MCPD in oil containing foods SGS Germany GmbH J. Kuhlmann

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Not authorized translation of original document

Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

EASI-EXTRACT MULTI-VIT B (LGE) Product Code: P183 / P183B

Test Results Standard. Appearance Light yellow, fine powder Matches std. Odour Characteristic Matches std. Taste Characteristic Matches std

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil

Agilent 1220 Infinity LC System Performance Specifications

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

Bruker Daltonics. autoflex III smartbeam. The Standard in MALDI-TOF Performance MALDI-TOF/TOF. think forward

Transcription:

LC-LC-GC-MS System PAH Product information

PAH analytics according to the impahct method Polycyclic aromatic hydrocarbons (PAH) are among the most frequently analyzed contaminants in diverse matrices. The reason for this is the partly very high carcinogenicity of the substance group and their broad distribution. PAH are formed during partial combustion and pyrolysis processes. They enter the environment through fumes, bound to dust particles or mineral oil residues. PAH contaminate foodstuff either from the environment (e.g. dust particles on broad-leaf vegetables) or by roasting and smoking processes. European guidelines set limiting values which vary depending on the foodstuff. For the marker substance benzo[a]pyrene the value lies between 1 6 µg/kg while the total limit value for the PAH4 (this term summarizes benzo[a]pyrene, benzo[a]anthracene, chrysene and benzo[b]fluoranthene) is 1-35 µg/kg. Due to the required sensitivity and complex matrices, PAH determination is a great challenge for analytics. As an analytical method either HPLC with fluorescence detection or GC-MS are used. Sample preparation is often extensive and time-consuming. Recent requirements to laboratories include a reduction in sample handling time (Turn- Around-Time) and an increase in the sample throughput. Still, no losses within the analytical parameters, e. g. sensitivity, precision and accuracy are desired. Consequently, highly automated analytical procedures are necessary. The LC-GC technology by Axel Semrau is established for the routine analytics of foodstuff and therefore provides an optimal basis for such an application system. Axel Semrau has developed a method for PAH analytics based on LC-GC technology, the impahct method: innovative multidimensional PAH clean-up technology. To measure PAH, a simple yet fast extraction of the sample is performed. The extract is quickly manually treated and then transferred to the LC-GC system by Axel Semrau. Here, the extract is purified in a two-step LC separation and subsequently analyzed via GC-MS. Applying this intelligent matrix management, it is possible to determine the PAH which are prescribed by EFSA fully automated. Depending on the detector, detection limits are reached which are even lower than the required European values for baby food by a factor of 100. The LC-GC solutions by Axel Semrau are pre-installed in application laboratories, tested and delivered to the customer readyto-use. Thus, the quickest possible continuation of the routine measurement is assured. Specifications LOD for all EFSA PAH between 0.01 0.02 µg/kg LOQ for all EFSA PAH < 0.06 µg/kg sensitivity values apply if using a Bruker EVOQ GC-TQ reproducibility: relative standard deviation < 15 % for entire method duration of analysis: 45 min PI Status: September 2017 Page 2 / 5

Benefits of the impahct method LOD 1/100 of the limit value for baby formula (example substance benzo[a]pyrene) fast results high degree of automation no consumables necessary (e.g. SPE cartridges) excellent reproducibility universally applicable to all foodstuff investment safety expandable to other applications Example chromatograms The LC-GC coupling supplies two chromatograms at the same time: the signal of the UV detector from the HPLC purification the signal from the GC-MS The illustrations on the following pages show examples of these chromatograms. System components The application system consists of the following components: CHRONECT Robotic consisting of: CTC PAL3 with an 85 cm axis and Software CHRONOS Agilent 1260 Infinity II HPLC pump with UV detector and degasser Bruker EVOQ GC-TQ CHRONECT LC-GC interface for the LC- GC coupling data system with control and evaluation software accessories and consumables Factory Acceptance Test instruction and commissioning Site Acceptance Test training, support PI Status: September 2017 Page 3 / 5

Pressure Product information [AU] 2,0 9,51 1,5 PAH (450 µl) 35 % CH 2 Cl 2 4,48 4,70 Fat 16,13 Absorbance 1,0 4,30 4,97 0,5 5,84 6,31 6,58 7,14 7,29 0,0 2,75 3,26 3,69 4,15 HPLC Chromatogramm erste Aufreinigung 0 5 10 15 20 Time [min.] [AU] [bar] 1.2 1.0 C:\Clarity\LC-GC_HPLC\Data\PAK\20141020\Blank_4 - VWD: Signal A 100 80 0.8 60 AU 0.6 0.4 40 0.2 20 2.8 2.9 4.5 5.3 5.5 SiO2 fraction Backflush PAH (~200 µl) 100 % CH 2 Cl 2 30.1 C:\Clarity\LC-GC_HPLC\Data\PAK\20141020\Blank_4 - LC Pressure Binary Pump 13.5 30.8 31.6 32.8 6.0 CH2Cl2 6.8 0.0 0 0 10 20 30 40 Figure 1: HPLC chromatogram of the first purification (upper chromatogram) and HPLC chromatogram of the two step HPLC purification (bottom chromatogram) Time [min.] Figure 2: LC-LC-GC-MS/MS measurement of cocoa butter which was doted to 0.04 µg/kg with PAH PI Status: September 2017 Page 4 / 5

Figure 3: Calibration curve for benzo[a]pyrene between 0.04-4 µg/kg Subject to technical changes The impahct method and the PAH Workstation are developments by Axel Semrau. Axel Semrau GmbH & Co. KG Stefansbecke 42 45549 Sprockhövel Tel.: + 49 2339 / 12090 Fax: + 49 2339 / 6030 www.axel-semrau.de info@axel-semrau.de PI Status: September 2017 Page 5 / 5