ATHLET VBR. The real winner. VBR in PEEK-OPTIMA PRODUCT INFORMATION

Similar documents
ATHLET VBR. The real winner. VBR in PEEK-OPTIMA PRODUCT INFORMATION

The Implant. (Klappen außen sind nur 192 mm breit!) Ordering information. You start we help with our clearly arranged Starter Kit:

HawkeyeTM Peek. surgical technique

Endoscopic Technology. Operating Manual. Cannula system

Preparation Instructions for the CAMLOG /CONELOG Implant System

Manufacturer s information

LBL-014. Rev

ECD EXPANDABLE CORPECTOMY DEVICE Continuously Expandable Vertebral Body Replacement for Tumour Cases

M6-C Artificial Cervical Disc Surgical Instruments

nvt Transforaminal Lumbar Interbody Fusion System

nvp Posterior Lumbar Interbody Fusion System

OPERATIVE TECHNIQUE. CONSTRUX Mini PTC. Mini PTC Spacer System

nva Anterior Lumbar Interbody Fusion System

XRL A modular expandable radiolucent vertebral body replacement system

Technique Guide. ECD Expandable Corpectomy Device. Continuously Expandable Vertebral Body Replacement for Tumour Cases.

C-THRU Anterior Spinal System

SYNEX The vertebral body replacement with ratchet mechanism

Alamo C. Cervical Interbody System Surgical Technique. An Alliance Partners Company

The A-Space SIBD Spinal System is a stand-alone device intended to be used with the four supplied bone screws if no supplemental fixation is used.

Aesculap CeSpace TM PEEK and CeSpace TM XP Spinal Implant System Instructions for Use

SURGICAL TECHNIQUE GUIDE BRECKENRIDGE. Intervertebral Body/VBR Fusion System. ACDF Anterior Cervical Discectomy and Fusion

Apache Cervical Interbody Fusion Device. Surgical Technique. Page of 13. LC-005 Rev F

SI-BONE ifuse Implant System Instruments Hospital Cleaning and Sterilization Instructions 0344

Reprocessing Guide. Autoclavable Arthroscope and Hardware Sterilization Tray

Replacement Device A modular expandable radiolucent vertebral body replacement system

X-spine Systems, Inc. Calix PC Spinal Implant System

Velocity Orthopedics Instrument Cleaning and Sterilization

Zavation Z-Link Cervical

Cervical Spacer System surgical technique

GIZA Surgical Technique

SURGICAL TECHNIQUE GUIDE BRECKENRIDGE. Intervertebral Body/VBR Fusion System. Oblique Lumbar Interbody Fusion

Surgical technique. synex. The vertebral body replacement with ratchet mechanism.

TABLE OF CONTENTS. ShurFit Anterior Cervical Interbody Fusion (ACIF) System Overview 2. Implant Specifications 3. Instrument Features 4

BAK/C Cervical Anterior Interbody Fusion System

Aesculap Implant Systems

Zimmer Anterior Buttress Plate System. Surgical Technique

Solitaire Anterior Spinal System

Headless Compession Screw 2.5 / 3.0

100 Interpace Parkway Parsippany, NJ

Aesculap Spine Instructions for use

Luminary ALIF. Disc preparation and implant insertion instruments.

PILLAR AL. Anterior Lumbar Interbody Fusion (ALIF) and Partial Vertebral Body Replacement (pvbr) PEEK Spacer System OPERATIVE TECHNIQUE

Gallery Laminoplasty Spine System

TONTARRA Medizintechnik GmbH. Surgical Instruments in Demand. Laminectomy Punches and Rongeurs

Headless Compession Screw 4.5 / 6.5 SURGICAL TECHNIQUE. Titanium or Stainless Steel. Cannulated Headless Design. Multiple Thread Options.

X-spine Systems, Inc. Axle Interspinous Fusion System

The vertebral body replacement with ratchet mechanism. Synex. Surgical Technique

Synex System TECHNIQUE GUIDE. An expandable vertebral body replacement device

VLIFT System Overview. Vertebral Body Replacement System

TSLP Thoracolumbar Spine Locking Plate

Recommendations for cleaning, disinfection and sterilization of orthopaedic instruments and devices from Swemac.

Surgical Technique Guide

VECTRA-T SURGICAL TECHNIQUE. The Translational Anterior Cervical Palate System. This publication is not intended for distribution in the USA.

product overview Implant heights range from 8mm-20mm in 2mm increments, with two lordocic angle options of 6 and 12.

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

Surgical Technique. Apache Anterior Lumbar Interbody Fusion

EFSPINE CERVICAL COMBINED SET DISC PROTHESIS ORGANIZER BOX

Technique Guide Small Bone Fusion System

Veyron -C Anterior Cervical System Surgical Technique

Customized Cranial and Craniofacial Implants. Instructions For Use. 7000revD_Instructions_For_Use. Page 1 of 8

EXACTECH SPINE. Operative Technique. Cervical Spacer System. Surgeon focused. Patient driven. TM

UNICLIP DIRECTIONS FOR USE REF C226U - 0,8 MM / 1 MM FOR DENTAL USE ONLY. FISDR / F EN / 11 / updated 06/2016 1/7

INSTRUCTIONS FOR USE AND CARE

Lapidus Arthrodesis System Instructions for Use

Royal Oak IBFD System Surgical Technique Posterior Lumbar Interbody Fusion (PLIF)

The Implant. (Klappen außen sind nur 192 mm breit!)

Handling Technique. Collinear Reduction Clamp. For minimally invasive fracture reduction.

ProUltra ULTRASONIC SURGICAL TIPS

Surgical Technique & Product Catalogue. Guide for Open & MIS Procedures

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

Table of Contents.

Altus Product description / Instructions for Use IFU 6 Rev. 1

DISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY

Straumann ProClean Cassette. Basic Information on the

Alamo T Transforaminal Lumbar Interbody System Surgical Technique

a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care

Hygienic Reprocessing

Advantage ALIF. Keith Shevlin Managing Director

X-spine Systems, Inc. Irix-A Lumbar Integrated Fusion System

EVOLVE TRIAD SYSTEM

X-spine Systems, Inc. Silex Sacroiliac Joint Fusion System

ACP. Anterior Cervical Plate System SURGICAL TECHNIQUE

SAMSON. Expandable Vertebral Body Replacement

Surgical Technique Guide

SYNCAGE EVOLUTION. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

For use by an Accredited Orthopaedic Surgeon only

DISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY

TABLE OF CONTENTS. Vault C Anterior Cervical Discectomy 2 and Fusion (ACDF) System Overview. Implants 3. Instruments 5. Surgical Technique 10

OPERATIVE TECHNIQUE. anterior cervical plating system

Thoracolumbar Solutions. Zyston Curve. Interbody Spacer System. Surgical Technique Guide

SynCage-C short. Surgical Technique. This publication is not intended for distribution in the USA.

Transforaminal Lumbar Interbody Fusion Cage (TLIF)

X-spine Aranax Anterior Cervical Plating System Instructions for Use / Package Insert

RibLoc U Plus CHEST WALL PLATING SYSTEM FOR THE PERSONAL ATTENTION OF THE OPERATING SURGEON

Amendia Interbody Fusion Devices PACKAGE INSERT

The Omega LIF System devices are made from Titanium alloy Ti6Al4V ELI, ASTM F136.

The AperFix II System

Posterior Lumbar Interbody Fusion System

Transcription:

ATHLET VBR in PEEK-OPTIMA The real winner PRODUCT INFORMATION VBR

PRODUCT INFORMATION The Concept A vertebral body replacement requires top performance Simple intra- and postoperative control Anatomic adaptation Economic product concept and simple handling ATHLET (athlitis = Greek for the contestant ) meets this challenge! Its unique concept combines all required characteristics in one product making it a real winner. Heights from 16 50 mm (in 2 mm increments) Manufactured from PEEK-OPTIMA Easy positioning and postoperative control Lordotic angulation Natural reconstruction of the spine Generous implant fenestration Optimal provision for bony in-growth Large contact area, toothed endplates High primary and secondary stability Heights from 16 50 mm Applicable for a broad range of indications and patient anatomies Clearly arranged instrumentation Easy handling reduces the risk of complications 15 mm 14 mm 13 mm 2

ATHLET The Implant 1 construct = 1 main body + 1 end body Latch mechanism for secure connection of the implant components 9 implant components: 6 main bodies and 3 end bodies Ordering information ATHLET end body Art. No. Height (mm) 1 AT0104 4 2 AT0206 6 3 AT0308 8 ATHLET main body Art. No. Height (mm) 4 AT0412 12 5 AT0518 18 6 AT0624 24 7 AT0730 30 8 AT0836 36 9 AT0942 42 Special sizes (available on request) Art. No. Height (mm) 12 AT1212 12 one-piece implant 13 AT1314 14 one-piece implant 14 AT1448 48 main body 15 AT1554 54 main body 16 AT1660 60 main body Single, sterile packed, ready to use. This device has labeling restrictions as indicated in the IFU. You start we help with our clearly arranged Starter Kit: Your mobile warehouse with all implant components 3

PRODUCT INFORMATION Instruments Art. No. Description 1 AT0004 Template 2 AT0003 Disconnector 3 AT0001 Inserter A AT0005 Inserter Plate small (for main body 4 and 5) B AT0006 Inserter Plate medium (for main body 6 and 7) C AT0007 Inserter Plate large (for main body 8 and 9) 4 AT001AY Instrument tray 5 AT002AY Tray for Trials 6 AT1100 Inserter for Trials 7 AT1016 - AT1050 Trial 16-50 mm (2 mm increments) 1 C 2 B A 4 3 5 6 7 When special ATHLET sizes are used, the appropriate instruments are included in the tray. 4

ATHLET Short description of the implantation Preoperative planning The extent of the resection and therewith the height of the vertebral body replacement can be estimated as usual with the preoperative radiographs and CT /MRI scans. Optionally, SIGNUS offers templates for various imaging modalities that can assist with planning. 50 46 42 38 34 30 26 22 18 mm 16 mm Performing the corpectomy and preparing the endplates After preparation the corpectomy is performed. To achieve an optimal fusion result the exposed vertebral body endplates are cleaned carefully. Attention Avoid excessive cleaning or complete removal of the cortical bone. This may weaken the endplates which leads to an increased risk of implant subsidence into the adjacent vertebral bodies. 5

PRODUCT INFORMATION Short description of the implantation Determining the implant height To determine the height, use the Trials 7. Attach the Trial to the Inserter 6 and carefully insert it into the defect under lateral fluoroscopy. The Trial must be seated firmly in the intervertebral space. To verify this try to pull the Trial out after release of the distraction. If the Trial is seated loosely or can even be withdrawn, then the next greater height must be selected. Assembly of the implant components For simple identification all implant components are provided with a number from 1 9 (according to the height). On the Template 1 you will find an overview of all the heights that can be bridged with ATHLET and the implant combinations to achieve these heights. Assemble the main body and end body required for the construct. The implant components are connected together by a latch mechanism that engages with an audible click. Disassembly of the implant components The connected implant components can only be disassembled with the Disconnector 2. Hold the instrument with the labeling upwards. Place the implant between the jaws of the instrument so that the protrusion fits into the window below the latch mechanism. By pressing the release button, the implant components are separated from each other. Attention Ensure the implant is correctly oriented during the disassembly process otherwise the implant can be damaged. 6

ATHLET Distraction and implantation 1a Distract the spinal segment to the desired height with a suitable spreader. 1b Select the appropriate Inserter Plate A B C for the implant and slide this onto the tip of the Inserter 3. The implant heights and the corresponding Inserter Plates are listed in the instrument description. Assembly 2 1a Place the tip of the Inserter into the wide portion of the opening in the Inserter Plate 1b Make sure that the slot in the tip of the Inserter is aligned as shown 2 Push the tip of the Inserter into the narrower opening of the Inserter Plate The assembled implant is threaded onto the Inserter by rotating the blue thumb wheel. The vertebral body replacement ATHLET can now be introduced into the situs of the patient. The final position of ATHLET has been reached when the Implant is flush with the ventral edge of the vertebral body and does not protrude into the spinal canal. The insertion of the implant is performed under imaging control. Note To improve the fusion result it is recommended to place bone graft and/ or a bone substitute into and around the implant. Additional fixation As with all vertebral body replacements, ATHLET requires supplemental fixation. This device has labeling restrictions as indicated in the IFU. 7

PRODUCT INFORMATION The ATHLET VBR System Instructions for Use Device description: The ATHLET VBR System is a lordotic, modular vertebral body replacement system. One cranial and one caudal component are assembled to create a device construct. These components are available in a variety of sizes. This enables the surgeon to choose the size suited to the individual pathology and anatomical condition. The assemble device comprises a central cannula for bone graft and lateral fenestrations for bony in-growth. The ATHLET VBR components are manufactured from polyetheretherketone (PEEK-OPTIMA LT1, Invibio ) as described by ASTM F2026. Integral marker pins are manufactured from titanium alloy (Ti-6Al-4V) as described by ASTM F136 / ISO 5832-3. Additionally, on special request there are two single component implants in heights of 12 and 14 mm available. Indications for use: The ATHLET VBR System is indicated for use to replace a vertebral body that has been resected or excised due to tumor or trauma/fracture. The device is intended for use as a vertebral body replacement in the thoracolumbar spine (from T1 to L5). The ATHLET VBR System is intended for use with supplemental fixation and should be implanted in pairs. Caution: These implants are intended for single use only and should not be re-implanted. Federal law restricts this device to sale by or on the order of a physician. Contraindications: Advanced osteoporosis Specific metal allergy (Titanium Only) Infection Complications: The patient should be informed of the following possible complications: Haematoma Pain Implant impaction Local or systemic infection Paraplegia Damage to local structures Precautions: 1. These implants are supplied sterile. Do not use if sterile packaging is opened or damaged. These devices are intended for single use only. Do not re-implant, re-sterilize, reprocess or reuse. 2. The physician/surgeon should consider the levels of implantation, patient weight, patient activity level and other patient conditions which may impact the performance of the system. 3. Throughout the entire procedure particular care must be exercised to protect nerve roots. 4. Carefully check and remove any bone splinters following resection. 5. Prior to implantation, check the required implant size. 6. Do not use excessive force to introduce the implants. 7. The selection of size and implantation of the implant remain the exclusive responsibility of the user surgeon who must be experienced in spinal surgery. 8. It is imperative that dissimilar metals do not come into contact in vivo. Accelerated corrosion may occur when two dissimilar metals are in contact within the body environment. 9. The ATHLET VBR System has not been evaluated for safety and compatibility in the MR environment. The ATHLET VBR System has not been tested for heating or migration in the MR environment. How supplied: The ATHLET VBR System is provided sterile. All sterile products are labelled STERILE. Do not use sterile products if the packaging has been damaged or previously opened. Do not re-sterilize or autoclave sterile implants. The associated instruments are provided clean but not sterile. Instruments are provided in an autoclavable tray. All instruments must be disassembled (if applicable) and cleaned before sterilization and introduction into a sterile surgical field. Cleaning: During use, keep instruments moist and do not allow blood and/or bodily fluids to dry on the instruments. Thoroughly clean all instruments as soon as possible after use. Implant inserters must be disassembled prior to cleaning. This is accomplished by pulling on the knob end of the threaded inserter to withdraw the component from the cannulated outer shaft. Pre-Cleaning: Manual pre-cleaning is performed to remove gross contaminants. Immerse the instrument without any bubbles at minimum of 5 min, in cold regular tap water. All movable components must be repeatedly mobilized under running water, until no visible contamination remains. Brush all exposed surfaces with a nylon bristle brush. Instruments with cavities as well as jointings, threads, hinges and springs have to be soaked in an ultrasonic bath for 10 min. at 40 C with 0,5% solution of alkanine cleaner (neodisher FA) and then rinsed from the inside and outside with a water spray gun at 58 psi (4 bar) static power for minim 20 s with cold regular tap water. 8

ATHLET Automated cleaning: Automated cleaning is the preferred cleaning method. Manual cleaning (above) should be performed prior to using automated cleaning equipment. Instruments have to be placed in the instrument tray of the purifier / disinfector (e.g Miele G7735). Instruments with cannula must be placed in the tray for micro-invasive surgery (MIS) instruments and must be connected to the spray nozzle system. Clean the instruments by using a program with analogue parameters (e.g. Vario TD): Minimum 2 min pre-washing with cold regular tap water Drain Dosing of e.g. neodisher FA (Dr. Weigert, Hamburg) at 40 C At 55 C, for 5 min cleaning with Neodisher FA forte, 0.5% (Miele, Princeton NJ) or alternative cleaning with an adequate purifier drain 3 min neutralization with warm water (> 40 C) drain 2 min rinsing with warm water (> 40 C) Drain with demineralised water Disinfection: Manual disinfection: Disinfect the instruments by using an FDA cleared disinfectant (VAH-list of the Association of applied Hygiene). Cavities as well as joints, threads, hinges and springs must be water-rinsed inside and outside. Automated operation: Automated thermal disinfection, at a maximum temperature of 93 C in the purifier / disinfector (part of the above mentioned Vario TD program) is performed under consideration of national requirements regarding the thermal disinfection performance of the equipment in use (e.g. A0=Value according standard EN ISO 15883-1). Drying: Manual drying: Dry the instrument with a fluff-free fabric. Cavities as well as joints, threads, hinges and springs have to be dried by compressed air. Also, the application of a vapor-permeable lubricant, suitable for steam sterilization based on paraffin/white-oil basis, should be used on moving parts. Automated operation: Drying of the instrument in the purifier / disinfector (one drying cycle, part of the Vario TD program) if applicable, the instrument can be dried by a fluff-free fabric. Cavities as well as joints, threads, hinges and springs have to be dried by compressed air. The application of a vapor-permeable lubricant, suitable for steam sterilization based on paraffin/white-oil basis, should be considered at these parts, too. After cleaning/disinfecting, the disassembled instruments should be re-examined for visible soil. If visible soil is found, repeat the cleaning process. Following re-examination, the instruments should be dried using a soft cloth and placed in their proper locations in the instrument cases. The disassembled inserter components are reassembled by introducing the threaded inserter shaft into the cannulated outer shaft until the two pieces are engaged. Inspection: Unless marked otherwise, instruments may be reused after reprocessing and sterilization. Before each reuse, inspect instruments including inaccessible areas, joints and moving parts for possible damage, wear or non-functioning parts. Carefully inspect the critical, inaccessible areas, joints and all movable parts. Damaged or defective instruments should not be used or processed. Contact your local sales representative for repair or replacement. Sterilization: Sterilization validation studies have shown the following recommendations for instrument sterilization are effective to an SAL of 10-6. The use of an FDA approved sterilization wrap is recommended. Method: Steam sterilisation Cycle: 4 times pre-vacuum Temperature: minimum 270 F (132 C) maximum 280 F (137 C) Exposure Time: 4 minutes Drying Time: 20 minutes Storage: Store the sterilised instruments in a dry, clean and non-fuzzing environment at room ambient temperature. Further Information: Recommended directions for the use of these systems (surgical operative techniques) are available at no charge upon request. For additional information please contact: SIGNUS MEDICAL LLC 18888 Lake Drive East Chanhassen, MN 55317, USA Phone: 1-952-294-8700 Fax: 1-952-975-0465 E-mail: info@signusmedical.com Product Guarantee: SIGNUS Medizintechnik GmbH guarantees that each individual spinal implant is manufactured with the greatest of care and from selected material. The entire process, from manufacture to final packaging, is under constant quality control. However, given that SIGNUS Medizintechnik GmbH has no influence over the selection or use of the implant, the diagnosis of the patient or the surgical technique used, or the handling of the implant following dispatch from our company, no guarantees can be given regarding a successful surgical result or the lack of complications. 9

10 PRODUCT INFORMATION

ATHLET Notes 11

NOTICE: This document was written by SIGNUS technical staff and is intended only to introduce the product. Information contained within this brochure should not be construed as surgical advice or medical opinion expressed or implied by SIGNUS. Signus Medical LLC 18888 Lake Drive East Chanhassen, MN 55318 Tel: 952-294-8700 Fax: 952-975-0465 info@signusmedical.com www.signusmedical.com Distributed by: 3451 Plano Parkway Lewisville, TX 75056 Tel: 1-888-288-5700 orthofix.com Rev. 2013-02 / 03