SYNCHRONIZED MEASUREMENTS OF MAXIMUM BLOOD FLOW VELOCITIES IN CAROTID, BRACHIAL AND FEMORAL ARTERIES, AND ECG IN HUMAN POSTURE CHANGES

Similar documents
MRI MEASUREMENTS OF CRANIOSPINAL AND INTRACRANIAL VOLUME CHANGE IN HEALTHY AND HEAD TRAUMA CASES

THERMAL RHYTHMOGRAPHY - TOPOGRAMS OF THE SPECTRAL ANALYSIS OF FLUCTUATIONS IN SKIN TEMPERATURE

Suzuka medical university of Science and technology, 2 Ehime University medical department,

Proceedings 23rd Annual Conference IEEE/EMBS Oct.25-28, 2001, Istanbul, TURKEY

AUTOCORRELATION AND CROSS-CORRELARION ANALYSES OF ALPHA WAVES IN RELATION TO SUBJECTIVE PREFERENCE OF A FLICKERING LIGHT

ANALYSIS OF PHOTOPLETHYSMOGRAPHIC SIGNALS OF CARDIOVASCULAR PATIENTS

A new algorithm applied to the analysis of the electrocardiogram of an isolated rat heart. Mostefa Ghassoul MIEEE

A NONINVASIVE METHOD FOR CHARACTERIZING VENTRICULAR DIASTOLIC FILLING DYNAMICS

INFLUENCE OF GENDER, TRAINING AND CIRCADIAN TIME OF TESTING IN THE CARDIOVASCULAR RESPONSE TO STRESS TESTS

FACTORS ASSOCIATED WITH THE PREDICTION OF ATTENDANCE TO THE UK BREAST SCREENING PROGRAMME

DETERMINATION OF MEAN TEMPERATURES OF NORMAL WHOLE BREAST AND BREAST QUADRANTS BY INFRARED IMAGING AND IMAGE ANALYSIS

EFFECTS OF MECHANICAL PUMPING ON THE ARTERIAL PULSE WAVE VELOCITY : PERIPHERAL ARTERY AND MICRO-VESSELS

A MODEL OF GAP JUNCTION CONDUCTANCE AND VENTRICULAR TACHYARRHYTHMIA

Estimation of arterial pulse wave velocity with a new improved Tissue Doppler method

CONFOCAL MICROWAVE IMAGING FOR BREAST TUMOR DETECTION: A STUDY OF RESOLUTION AND DETECTION ABILITY

HOLOGRAPHIC DEFORMATION ANALYSIS OF THE HUMAN FEMUR

TEMPERATURE DISTRIBUTION PATTERN IN NORMAL AND CANCER TISSUES: THE EFFECT OF ELECTROMAGNETIC WAVE

NON-INVASIVE MEASUREMENT OF DIAPHRAGMATIC CONTRACTION TIMING IN DOGS

VASCULAR ADAPTATIONS TO TRANSVERSE AORTIC BANDING IN MICE

AN INSTRUMENT FOR THE BEDSIDE QUANTIFICATION OF SPASTICITY: A PILOT STUDY

Feature Parameter Optimization for Seizure Detection/Prediction

SITES OF FAILURE IN MUSCLE FATIGUE

PHASE RESPONSE OF MODEL SINOATRIAL NODE CELLS - AN INVESTIGATION OF THE INFLUENCE OF STIMULUS PARAMETERS

JAMES R. KNIGHT

EYE POSITION FEEDBACK IN A MODEL OF THE VESTIBULO-OCULAR REFLEX FOR SPINO-CEREBELLAR ATAXIA 6

ASSISTANCE TO SURGERY BY MEANS OF INFRARED FUNCTIONAL IMAGING: PRELIMINARY RESULTS

Influence of Inter-electrode Distance on EMG

Juan Carlos Tejero-Calado 1, Janet C. Rutledge 2, and Peggy B. Nelson 3

FEASIBILITY OF EMG-BASED CONTROL OF SHOULDER MUSCLE FNS VIA ARTIFICIAL NEURAL NETWORK

Study of high-frequency electrocardiogram *

DYNAMIC SEGMENTATION OF BREAST TISSUE IN DIGITIZED MAMMOGRAMS

Reflex and Non-Reflex Torque Responses to Stretch of the Human Knee Extensors

BARORECEPTOR-SENSITIVE FLUCTUATIONS OF HEART RATE AND PUPIL DIAMETER

A Simulation for Estimation of the Blood Pressure using Arterial Pressure-volume Model

INCLUSION OF ECG AND EEG ANALYSIS IN NEURAL NETWORK MODELS

FURTHER STUDY OF SPECTRUM FROM STOMACH CANCER SERUM EMISSION

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

T.J. Meitzler US Army, TARDEC Warren, MI J. S. Steckenrider Illinois College Jacksonville, IL. L. P. Franks US Army, TARDEC Warren, MI

Change in Elasticity Caused by Flow-Mediated Dilation Measured Only for Intima Media Region of Brachial Artery

A MULTI-STAGE NEURAL NETWORK CLASSIFIER FOR ECG EVENTS

VFI Technology to Change the Way You Work

AN ANALYTICAL MODEL OF A SPINAL ROOT STIMULATED NEUROMUSCULAR SYSTEM

A RECOGNITION OF ECG ARRHYTHMIAS USING ARTIFICIAL NEURAL NETWORKS

I. INTRODUCTION. environment of cell and tissues [2].

DEVELOPMENT OF ULTRASONIC TESTING TECHNIQUE TO INSPECT CONTAINMENT LINERS EMBEDDED IN CONCRETE ON NUCLEAR POWER PLANTS

Carotid Abnormalities Coils, Kinks and Tortuosity David Lorelli M.D., RVT, FACS Michigan Vascular Association Conference Saturday, October 20, 2012

COMPARISON OF LINEAR AND NON-LINEAR ANALYSIS OF HEART RATE VARIABILITY IN SEDATED CARDIAC SURGERY PATIENTS

Long-term Sleep Monitoring System and Long-term Sleep Parameters using Unconstrained Method

AN INTRODUCTION TO DOPPLER. Sarah Gardner, Clinical lead, Tissue viability service. Oxford Health NHS Foundation Trust.

: Biomedical Signal Processing

NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment

D. G. Kamper 1,2, W. Z. Rymer 1,2

ACTION POTENTIAL TRANSFER AT THE PURKINJE - VENTRICULAR JUNCTION: ROLE OF TRANSITIONAL CELLS

CLASSIFICATION OF SLEEP STAGES IN INFANTS: A NEURO FUZZY APPROACH

Underwater Acoustic Measurements in Megahertz Frequency Range.

Dual channel photoplethysmography studies of cardio-vascular response to the body position changes

Ultrasound in Medicine

Automated Detection of Epileptic Seizures in the EEG

Human Cardiovascular Physiology: Blood Pressure and Pulse Determinations

HEART RATE VARIABILITY MEASUREMENTS DURING EXERCISE TEST MAY IMPROVE THE DIAGNOSIS OF ISCHEMIC HEART DISEASE

ESTIMATION OF COHERENCE BETWEEN THE PULSATILE AORTIC BLOOD PRESSURE AND THE RENAL CORTICAL FLUX IN DODS

(received 23 September 2004; accepted 18 October 2004)

Goals. Access flow and renal artery stenosis evaluation by Doppler ultrasound. Reimbursement. WHY use of Doppler Ultrasound

Blood Pressure Determination Using Analysis of Biosignals

Descriptions of NDT Projects Fall 2004 October 31, 2004

A SYSTEM FOR MONITORING POSTURE AND PHYSICAL ACTIVITY USING ACCELEROMETERS

EFFECT OF ROBOT-ASSISTED AND UNASSISTED EXERCISE ON FUNCTIONAL REACHING IN CHRONIC HEMIPARESIS

Spectral broadening of ophthalmic arterial Doppler signals using STFT and wavelet transform

HUMAN ANATOMY AND PHYSIOLOGY

ANALYSIS OF HIV PROTEINS USING DSP TECHNIQUES

Development of Non-Restraint Blood Pressure Measurement Method Utilizing PWV

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

A GENETIC APPROACH TO SELECTING THE OPTIMAL FEATURE FOR EPILEPTIC SEIZURE PREDICTION

Vascular Sonography Examination

Optimising your Doppler settings for an accurate PI. Alison McGuinness Mid Yorks Hospitals

#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure

Problems of Carotid Doppler Scanning Which Can Be Overcome by Using Frequency Analysis

PHONOCARDIOGRAPHY (PCG)

Ultrasound 10/1/2014. Basic Echocardiography for the Internist. Mechanical (sector) transducer Piezoelectric crystal moved through a sector sweep

Non-invasive examination

A STUDY OF ULTRASOUND MEASUREMENT UTILIZED FOR THE LIVER TESTING

A STUDY ON THE SYSTEM FOR TREATMENT OF ADHD USING VIRTUAL REALITY

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Estimation of Systolic and Diastolic Pressure using the Pulse Transit Time

Chapter 15: Measuring Height, Weight, and Vital Signs. Copyright 2012 Wolters Kluwer Health Lippincott Williams & Wilkins

Vascular Modeling & Hemodynamics Research OUTLINE. CLINICAL MOTIVATION: Stroke. BACKGROUND: Diagnosis

DIAGNOSTIC TECHNIQUE OF ABNORMALITIES IN BALL BEARINGS WITH AN ULTRASONIC METHOD

Page 1 of 4 I. INTRODUCTION

VISUALIZATION OF TRANSDUCER-PRODUCED SOUND FIELDS IN SOLIDS

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

Guide to Small Animal Vascular Imaging using the Vevo 770 Micro-Ultrasound System

Image Formation (10) 2 Evaluation and Selection of Representative Images (10)

Lab #3: Electrocardiogram (ECG / EKG)

NCVH. Ultrasongraphy: State of the Art Vein Forum 2015 A Multidisciplinary Approach to Otptimizing Venous Circulation From Wounds to WOW

Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer

iworx Sample Lab Experiment HC-5: Body Position, Exercise, and Cardiac Output

The Fetus: Five Top Do Not Miss Diagnoses. Doppler Ultrasound

Mechanical Vibration Causes, Effect, Analysis & Prevention Techniques

Blood Pressure Monitor PASESA

Continuous Monitoring of Blood Pressure Based on Heart Pulse Analysis

Transcription:

SYNCHRONIZED MEASUREMENTS OF MAXIMUM BLOOD FLOW VELOCITIES IN CAROTID, BRACHIAL AND FEMORAL ARTERIES, AND ECG IN HUMAN POSTURE CHANGES Y.Hirao*, **, T.Kuroda*, D.Zhang*, Y.Kinouchi*, H.Yamaguchi*** and K.Yoshizaki*** *Dept.of Electrical and Electronic Eng., Univ. of Tokushima, Tokushima, 77-856 Japan **Electronic and Mechanical Sec., Tokushima Pref.I.T.C., Tokushima, 77-821 Japan ***Dept. of Physiology, Univ. of Tokushima, Tokushima, 77-853 Japan Abstract-In this research, the system has been developed to measure the maximum blood flow velocity simultaneously by an ultrasonic Doppler technique in three arteries during posture changes. As a peculiarity of this system, two semicircular transducers of 15.mm in diameter were used as a transmitter to irradiate a wide ultrasonic beam and a receiver. Because, the position relation between an and transducers change rapidly during exercise. This system could be applied to a human body changing from a sitting position to an erect position with voluntary muscle constriction. As a result of measurements, the maximum blood flow velocity in femoral has been increased significantly in posture changes like the above. Keyword-ultrasonic Doppler method, blood flow measurement, maximum blood flow velocity, blood position shift 1. INTRODUCTION It is expected that the dynamics of blood flows in exercising include a lot of useful information as to medical diagnoses and functional analyses of blood circular systems [1-5]. There are two kinds of non-invasive blood flow measurement technique, one is to utilize ultrasonic methods, another to use optical ones. The ultrasonic Doppler technique can measure dynamics of blood flows in the that exists in the deep place of the human body [1-5]. Since the position of the and the transducers change rapidly during exercise, conventional ultrasonic systems using narrow directional transducers are difficult to measure a dynamics of blood flows during exercise. The purpose of this research is to measure blood flow velocities in the human during exercise [5]. For this purpose, wide ultrasonic beam is realized by using semicircular transducer of 15.mm in diameter. Measurement sys- Hemodynamometer tem using an ultrasonic Doppler technique has been developed, which is able to measure the maximum blood flow velocities during posture changes. 2. MATERIALS AND METHODS A. Systems As shown in Figure 1, a system consists of six parts: an ultrasonic probe, a Doppler signal discriminator, an electrocardiogram (ECG) circuit, a hemodynamometer, an A/D converter and a personal computer. A continuous wave ultrasonic signal of 2.MHz is irradiated to the human three arteries (carotid, brachial and femoral) in the human, and the ultrasonic probe receives the signal reflected from the arteries. Frequencies of the reflected signal from blood flows are shifted by Doppler effect. After shifting the Doppler signal to an audio band in a frequency region, a 4-order low-pass filter of 4.2kHz and a 4- order high-pass filter of 1Hz are used to remove high frequency noise and low frequency noise due to slow moving of the blood s in the tissues. The Doppler signal is digitized and saved to a personal computer. Carotid Brachial Femoral Electrocardiogram(ECG) Ultrasonic plobe Doppler signal discriminator Analog-digital converter Fig.1.Constitution of a measurement system Personal computer

Report Documentation Page Report Date 25OCT21 Report Type N/A Dates Covered (from... to) - Title and Subtitle Synchronized Measurements of Maximum Blood Flow Velocities in Carotid, Brachial and Femoral Arteries, and ECG in Human Posture Changes Author(s) Contract Number Grant Number Program Element Number Project Number Task Number Work Unit Number Performing Organization Name(s) and Address(es) Dept.of Electrical and Electronic Eng., Univ. of Tokushima, Tokushima, 77-856 Japan Sponsoring/Monitoring Agency Name(s) and Address(es) US Army Research Development & Standardization Group (UK) PSC 82 Box 15 FPO AE 9499-15 Performing Organization Report Number Sponsor/Monitor s Acronym(s) Sponsor/Monitor s Report Number(s) Distribution/Availability Statement Approved for public release, distribution unlimited Supplementary Notes Papers from the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, October 25-28, 21, held in Istanbul, Turkey. See also ADM1351 for entire conference on CD-ROM., The original document contains color images. Abstract Subject Terms Report Classification Classification of Abstract Classification of this page Limitation of Abstract UU Number of Pages 4

The Doppler signal is analyzed by 256 points (25.6ms) fast Fourier transform (FFT) with a Hanning window. FFT is repeated by using successive 256 data, which are given by shifting 128 data in turn. The relation of a blood flow velocity (Vd) and a Doppler shift frequency (fd) is given by Vd = C fd 2f O cosθ where, C=154(m/s) is the sound speed in a human body, f is an irradiated ultrasound frequency and θ=45deg is the angle of the transducers and the blood (Figure 2). Pseudo-three-dimensions (3-D) graph, as a result of these analyses, and an enlarged pseudo 3-D graph are shown in Figure 3. The triangle in enlarged pseudo 3-D graph is a pulsation. We pay attention to the point of maximum blood flows velocity in pulsation. Skin Ultrasonic plobe Blood θ Flow Fig.2.Angle of transducers and a blood 1..5 B. Problems and Solutions There are two problems for measuring blood flow velocities by ultrasonic Doppler effects from a human body during exercise. The first problem is that the probe itself may shift on the skin. As a result, noise mixes in the Doppler signal. In this research, probes have been fitted to in the human body using an elastic belt so as not to shift during exercise (Figure 4). The second problem is that the position relation between an and a probe change rapidly by exercise. As a result, blood s are moved out from ultrasonic irradiation field. The maximum blood position shift was measured at the carotid, the brachial and the femoral arteries by using an ultrasonic diagnostic equipment. For five subjects, the position was shifted to its maximum with curvature movement of a foot, an arm and a neck and so on. The carotid position moved 14.3mm with maximum from the erect position. Similarly, the maximum position shift was 11.9mm and 2.3mm for the brachial and femoral arteries respectively. In this research, the transmitter and receiver are changed into semicircular transducers of 15.mm from that of 7.mm in diameter to extend the ultrasonic irradiation range. The system can therefore work for a certain amount of blood position shift. C. Experiments The blood flow velocity, blood pressure and ECG of five normal subjects have been measured for the carotid, brachial and femoral arteries. These are major peripheral arteries in human body. Besides, when converting a Doppler frequency into a blood flow velocity, resultant errors may be small because the arteries are parallel to the skin (Figure 5). 2 4 Power Spectrum 1 5 Maximum Blood Flow Velocity 1.2 1..8.6.4.2.1.2.3.4.5.6.7.8.9 1. 1.1 1.2 1.3 1.4 Fig.3. Pseudo-three-dimensions graph of blood flow velocity distributions Fig.4.Photograph of the probe installation

1..5 2 4 6 8 1 Carotid 1..5 2 4 6 8 1 Brachial 1..5 2 4 6 8 1 Femoral Fig.6.Pseudo-three-dimension (3-D) graph of blood flow velocity in the carotid, the brachial and the femoral arteries from a subject at thirty five ages during posture changes Table.1.The Blood pressure and the heart rate during change from the erect position to the sitting position Systolic pressure 14 134 141 Diastolic pressure 112 97 98 Heart rate 86 83 79 We have measured continuously dynamics of blood flows during the posture changes. The subjects have changed the posture from the erect position to the sitting position. Each posture change is performed in five seconds, and subject has been stood still for thirty seconds with each posture. Dynamics of blood flows and ECG has been measured for a hundred seconds in total, and on the other hand the blood pressure has been measured once with each posture. As for

skin skin blood { brachial crotid skin blood { blood { Fig.5. Position relation of a skin and a blood this experiment, the blood may shift significantly with posture changes. 3. RESULTS AND DISCUSSION The pseudo 3-D graphs of blood flow velocities in the carotid, the brachial and the femoral arteries and blood pressure shown in Figure 6 and Table 1. The position of the blood moves significantly by posture changes. When the subject changes from the sitting position to the erect position, Doppler signal includes spontaneous velocity components in the brachial and the femoral arteries. This components is considered to be a noise that occurs with movements of the muscle during exercise because signal exists in the whole velocity component uniformly. However, the change of the maximum blood flow velocities is observed obviously in the pseudo 3-D graph. The maximum blood flow velocity in all arteries increases with the change of postures. It increases significantly at the femoral because of intense contraction of the muscle around the. 4. CONCLUSION femoral We measured the maximum blood position shift in the carotid, the brachial and the femoral arteries and changed into semicircular transducer of 7.mm in diameter to that of 15.mm in diameter. As a result, the blood position shifted during posture changes but this system had been measured to a blood flow velocities by using an ultrasonic beam widely. The noise which, occurs with probe shift on the skin was removed because the ultrasonic probe has been fitted in the body using an elastic belt. As for experiment that subject change from the erect position to the sitting position, the change of maximum blood flow velocity was observed obviously in the pseudo 3-D graph. The maximum blood flow velocity increases in these arteries with posture changes. In three arteries, the femoral shows the largest velocity change because of a strong muscle contraction. In this way, this system is effective for the simultaneous measurements of the maximum blood flow velocities at several points during the posture changes like stand up from chair and sit down. REFERENCES [1] A.-M. Salmasi, S.N. Salmasi, C.Dore and A.N.Nicolaides, Non-invasive assessment of changes in aortic blood velocity and its derivatives with exercise in normal subjects by Doppler ultrasound, J. Cardiovasc. Surg., vol.28, no2, pp.321-327, 1987. [2] B. E. van Leeuwen, G. J. Barendsen, J.Lubbers and L. de Pater, Calf blood flow and posture: Doppler ultrasound measurement during and after exercise, J. Appl. Physiol., vol.72, no5, pp.1675-168, 1992. [3] J. He, Y. Kinouchi, T. Iritani, H. Yamaguchi and H. Miyamoto, Telemetering blood flow velocity and ECG during exercise, Innovation and Technology in Biology and Medicine, vol.13, no5, pp.567-577, 1992. [4] J. He, Z. -L. Jiang, H. Tanaka, T. Ikehara, A. takahashi, H. Yamaguchi, H. Miyamoto, T. Iritani, and Y. Kinouchi, Changes in carotid blood flow and ECG in humans during and after walking on a treadmill, European J. Applied Physiology and Occupational Pysiology, vol.67, no.6, pp.486-491, 1993. [5] Y.Hirao, K.Tamukai, Y.Kinouchi, and H.Yamaguchi, Synchronized measurements of blood flow velocity distributions in carotid, brachial and femoral arteries, and ECG in human during exercise, 21st Annual Int. Conf. of the EMBS, Atlanta, GA. USA Oct. 13-16, 1999