HOSPITAL PROCEDURE Collaborative Practice Committee

Similar documents
Julie Zimmerman, MSN, RN, CCRN Clinical Nurse Specialist

Capnography for Pediatric Procedural Sedation Learning Module Last revised: February 18, 2014

ASPIRUS WAUSAU HOSPITAL, INC. Passion for excellence. Compassion for people. SUBJECT: END TIDAL CARBON DIOXIDE MONITORING (CAPNOGRAPHY)

Safe Use of Opioids in Hospitals: Addressing The Joint Commission Sentinel Event Alert

MANUAL MEDICAL DIRECTOR RESPIRATORY BOB MILLER, BS, RRT, RCP RESPIRATORY SERVICES DIRECTOR APPROVED BY

Capnography Connections Guide

Capnography (ILS/ALS)

Capnography. Capnography. Oxygenation. Pulmonary Physiology 4/15/2018. non invasive monitor for ventilation. Edward C. Adlesic, DMD.

Identification of patients at risk for Opioid-Induced Respiratory Depression

3/30/12. Luke J. Gasowski BS, BSRT, NREMT-P, FP-C, CCP-C, RRT-NPS

Capnography: The Most Vital of Vital Signs. Tom Ahrens, PhD, RN, FAAN Research Scientist, Barnes-Jewish Hospital, St. Louis, MO May, 2017

Pain Module. Opioid-RelatedRespiratory Depression (ORRD)

1. When a patient fails to ventilate or oxygenate adequately, the problem is caused by pathophysiological factors such as hyperventilation.

EMS System for Metropolitan Oklahoma City and Tulsa 2017 Medical Control Board Treatment Protocols

Capnography 101. James A Temple BA, NRP, CCP

Association for Radiologic & Imaging Nursing

Capnography: Creating a Culture of Safety! An Interview With Peggy Lange, RT!

June 2011 Bill Streett-Training Section Chief

How it Works. CO 2 is the smoke from the flames of metabolism 10/21/18. -Ray Fowler, MD. Metabolism creates ETC0 2 for excretion

Subspecialty Rotation: Anesthesia

Interfacility Protocol Protocol Title:

End Tidal CO2 Not All Its Cracked Up To Be The Limitations of PETCO2 In Sedation Analgesia

Nihon Kohden America. Capnography Monitoring with the CapONE CO2 Sensor For use with the BSM 2300/4100/5100 and the BSM 6000 Series Bedside Monitors

Non-Invasive Assessment of Respiratory Function. Chapter 11

ETCO2 MONITORING NON-INTUBATED PATIENTS

I. Subject. Moderate Sedation

Capnography: The Most Vital Sign

QUICK REFERENCE GUIDE CAPNOGRAPHY DURING PROCEDURAL SEDATION

Emergency Department Guideline. Procedural Sedation and Analgesia Policy for the Registered Nurse

8/26/2011. Disclosures. Objectives. None

Monitoring Patients for Respiratory Depression: outside of the ICU. James D. Harrell, RCP San Diego Patient Safety Council November 14, 2014

Respiratory Rate. Disclosure: Research grants and honoraria from Masimo Corp

Ventilator Waveforms: Interpretation

Prepared by : Bayan Kaddourah RN,MHM. GICU Clinical Instructor

CAPNOGRAPHY. 1.1 To set forth the policy and procedure for performing continuous end-tidal waveform capnography.

Foundation in Critical Care Nursing. Airway / Respiratory / Workbook

Non-invasive Ventilation protocol For COPD

Maria Tracey, Director-Perioperative and Elaine Warren, Directory-Surgery Level. III (Three)

POLICY All patients will be assessed for risk factors associated with OSA prior to any surgical procedures.

They aren t the same thing. Daniel Dunham

NOTE: CONTENT CONTAINED IN THIS DOCUMENT IS TAKEN FROM ROSEN S EMERGENCY MEDICINE 9th Ed.

Interesting Capnography Cases

2 hospital system, tertiary care, community, referral centers

Don t let your patients turn blue! Isn t it about time you used etco 2?

A Business & Clinical Case for Continuous Surveillance

Optimize vent weaning and SBT outcomes. Identify underlying causes for SBT failures. Role SBT and weaning protocol have in respiratory care

Handling Common Problems & Pitfalls During. Oxygen desaturation in patients receiving mechanical ventilation ACUTE SEVERE RESPIRATORY FAILURE

OWN THE AIRWAY. Airway Management Bruce Barry, RN, CEN, CPEN, TCRN, NRP. Paramedic Program

Capnography: Not just for confirmation

NON INVASIVE LIFE SAVERS. Non Invasive Ventilation (NIV)

Pain Management Portfolio FAQs

Dr Alireza Yarahmadi and Dr Arvind Perathur Mercy Medical Center - Winter Retreat Des Moines February 2012

Capnography Could Make You a Rock Star!

Procedures/Risks: pulmonology, sleep, critical care

Reducing Adverse Drug Events Related to Opioids: An Interview with Thomas W. Frederickson MD, FACP, SFHM, MBA

Hypoventilation? Obstructive Sleep Apnea? Different Tests, Different Treatment

WRHA Surgery Program. Obstructive Sleep Apnea (OSA)

BiLevel Pressure Device

Ron Hosp, MS-HSA, RRT Regional Respiratory Specialist. This program has been approved for 1 hour of continuing education credit.

10/17/2016 OXYGEN DELIVERY: INDICATIONS AND USE OF EQUIPMENT COURSE OBJECTIVES COMMON CAUSES OF RESPIRATORY FAILURE

1/27/2017 RECOGNITION AND MANAGEMENT OF OBSTRUCTIVE SLEEP APNEA: STRATEGIES TO PREVENT POST-OPERATIVE RESPIRATORY FAILURE DEFINITION PATHOPHYSIOLOGY

Using an Inhaler and Nebulizer

Appendix D An unresponsive patient with shallow, gasping breaths at a rate of six per minute requires:

The goal of deep sedation is to achieve a medically controlled state of depressed consciousness from which the patient is not easily aroused.

IFT1 Interfacility Transfer of STEMI Patients. IFT2 Interfacility Transfer of Intubated Patients. IFT3 Interfacility Transfer of Stroke Patients

Stellar 100 Stellar 150

Objectives. Health care significance of ARF 9/10/15 TREATMENT OF ACUTE RESPIRATORY FAILURE OF VARIABLE CAUSES: INVASIVE VS. NON- INVASIVE VENTILATION

Test Bank Pilbeam's Mechanical Ventilation Physiological and Clinical Applications 6th Edition Cairo

Guidelines Administrative Practice X Clinical Practice Professional Practice

LVADs, Supraglottic Airways and CPAP

PHYSICIAN COMPETENCY FOR ADULT DEEP SEDATION (Ages 14 and older)

The case for capnography in patients receiving opioids

Addendum D. Procedural Sedation Test MERCY MEDICAL CENTER- SIOUX CITY. Procedural Sedation Questions

Effective peri-operative noninvasive PCO2 monitoring

Effective peri-operative noninvasive PCO2 monitoring

Complex Care Hub Manual: Continuous Positive Airway Pressure (CPAP) Ventilation

Airway Clearance Devices

Attestation for Completion of Procedural Sedation Course for Level I Moderate Procedural Sedation Privileges

KENNEDY DISEASE PULMONARY CONSIDERATIONS: SCIENCE & MANAGEMENT STRATEGIES

Chapter 26. Assisting With Oxygen Needs. Elsevier items and derived items 2014, 2010 by Mosby, an imprint of Elsevier Inc. All rights reserved.

NIV - BI-LEVEL POSITIVE AIRWAY PRESSURE (BIPAP)

Web Appendix 1: Literature search strategy. BTS Acute Hypercapnic Respiratory Failure (AHRF) write-up. Sources to be searched for the guidelines;

This interdisciplinary clinical support document provides guidelines for the safe establishment of an artificial airway.

Anaesthetic considerations for laparoscopic surgery in canines

Bi-Level Therapy: Boosting Comfort & Compliance in Apnea Patients

Overview. The Respiratory System. Chapter 18. Respiratory Emergencies 9/11/2012

Capnography- A Review and Renewed Perspective of its Uses and Limitations

Challenging Cases in Pediatric Polysomnography. Fauziya Hassan, MBBS, MS Assistant Professor Pediatric Pulmonary and Sleep

Volume Guarantee Initiation and ongoing clinical management of an infant supported by Volume Guarantee A Case Study

Respiratory Physio Protocol for Paediatric Patients on BIPAP via a tracheotomy (uncuffed tube)

Up to 50% of continuous flow oxygen therapy patients experience clinically significant nocturnal desaturation. 1

Emergency)tracheostomy)management)/)Patent)upper)airway)

ACUTE RESPIRATORY DISTRESS SYNDROME (ARDS) Rv

CENTRAL IOWA HEALTHCARE Marshalltown, Iowa

The Role of Capnography in EMS. By Bob Page, AAS, NREMT-P, CCEMT-P, I/C

Airway Management Essentials Self-Study Guide

CAPNOGRAPHY in the SLEEP CENTER Julie DeWitte, RCP, RPSGT, RST Assistant Department Administrator Kaiser Permanente Fontana Sleep Center

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE

NATIONAL COMPETENCY SKILL STANDARDS FOR PERFORMING POLYSOMNOGRAPHY/SLEEP TECHNOLOGY

Transcription:

Title: Capnography (ETC0 2 ) Monitoring Code: CPC-2012AUG-1.C.35 HOSPITAL PROCEDURE Collaborative Practice Committee Title of Responsible Party: Director of Medical-Surgical Services Origination Date: 5/2009 Effective Date: 8/2012 Review/Revision Dates: 1/2013 Scope: Capnography provides information about CO 2 production, pulmonary (lung) perfusion, alveolar ventilation, respiratory patterns, and exhaled elimination of CO 2. It offers an immediate picture of patient s ventilatory status. ETC0 2 is more sensitive than pulse oximetry, and can identify hypoventilation and apneic episodes before is is picked up by changes in heart rate and/or pulse oximetry. ETC0 2 monitoring is for patients who are determined to be at risk for complications due to pain management and/or obstructive sleep apnea. ETC0 2 monitoring should be initiated prior to start of pain management interventions and pre-procedural moderate sedation induction. ETC0 2 monitoring may be initiated by a physician s order and/or based on the discretion of the RN. Key Words: @ETC0 2, @Capnography, @Sedation, PCA, @Pain management Purpose: The purpose of this document is to outline the indications and procedure for end tidal carbon dioxide (ETC0 2 ) monitoring. ETC0 2 monitoring is used to obtain non-invasive measure of the ETC0 2 and is an early detection of the clinical indicators for respiratory depression evaluated through monitoring airway patency, CO 2 removal (ETC0 2 level) and respiratory rate. This policy is not for patients receiving epidural PCA or those who are receiving palliative care receiving intravenous medications per PCA. 1 Clinical applications: 1.1 Patients with pain management issues requiring high dosages of narcotics 1.2 Patients receiving epidural or intrathecal pain management 1.3 Patients who are difficult to arouse 1.4 Patients with a history of respiratory distress or sleep apnea 1.5 Patients who easily desaturate 1.6 Patients requiring procedural sedation 2 Equipment: 1.1 ETC0 2 monitor 1.2 Oridion Capnography monitor or Alaris brain with ETCO 2 module or Capnostream monitor Capnography (ETCO2 Monitoring CPC-2013JAN-1.C.35 Page 1 of 9

1.3 Oridion Smart CapnoLine Text: 1 Set Up 1.1 Obtain ETCO 2 monitor from central supply 1.2 Obtain Smart CapnoLine from clean supply room 1.3 Attach Smart CapnoLine into the ETCO 2 monitor port 1.4 Explain the purpose of ETC0 2 monitor and alarm feature to the patient 1.5 Apply Smart CapnoLine to patient to allow sampling from either nose or mouth 1.6 Change tubing set every twenty-four hours or more often as needed to ensure accurate measurements 1.7 Turn ETCO 2 monitor on. The machine will run a self-test. 1.8 Recommended default alarm limits for the following settings: 1.8.1 ETC0 2 High - 60 mmhg 1.8.2 ETC0 2 Low - 10 mmhg 1.8.3 Respiratory rate High 48 breaths per minute 1.8.4 Respiratory rate Low 7 breaths per minute 1.8.5 No breath delay 30 seconds 1.9 The Smart CapnoLine last for up to 72 hours and must be changed when the ETC0 2 monitor displays a Blockage or Occlusion message 2 ETCO2 Values 2.1 Normal: Adults: ETCO 2 35 to 45mmHg (in normal, healthy adults) 2.2 Abnormal ETCO 2 Values: 2.1.1 An ETCO 2 less than 35 mmhg indicates an increased respiratory rate or Hyperventilation/ Hypocapnia" 2.2.2 An ETCO 2 more than 45 mmhg indicates respiratory depression or "Hypoventilation/ Hypercapnia" 2.3 A sudden loss of ETCO 2 indicates no respiratory activity (apnea). 2.4 Medical conditions that affect reliability of ETC0 2 values include: 2.4.1 COPD (causing incomplete alveolar emptying) 2.4.2 ARDS (causing a ventilation-perfusion mismatch) 2.4.3 Pulmonary embolism and hypovolemia (causing unperfused, but ventilated alveoli) 2.5 For further information on interpreting abnormal ETCO 2 values and waveforms, see Interpreting ETCO 2 and waveforms below. 3 General Care and Monitoring 3.1 ETC0 2 monitoring should be used in conjunction with pulse oximetery. 3.2 The Smart CapnoLine samples CO2 continuously from both mouth or nose, even for low tidal volumes. The oxygen tubing portion of the Smart CapnoLine can be attached to an oxygen source if needed. Up to 5L of oxygen can be delivered via the SmartCapnoLine. For patients requiring greater than 5L of oxygen therapy, it is necessary to add an oxygen mask (the mask can be placed directly over the cannula). Note: Adding ooxygen by mask may lower the ETC0 2 reading by 10% or more, and values should not be considered reliable. 3.3 ETC0 2 monitoring may be used with PCA to provide continued assessment of physiological response to pain management by evaluating trends in ventilatory status. 3.4 ETC0 2 measurements should be evaluated over a 1 to 2 minute time frame every four (4) hours or more often as patient condition warrants. Some patients may require more frequent monitoring (for example, pain management patients requiring additional bolus Capnography (ETCO2 Monitoring CPC-2013JAN-1.C.35 Page 2 of 9

doses, continuous basal rates, or if other risk factors for respiratory depression are identified). 3.5 Monitoring ETC0 2 trends can be more important than the actual number. A steadily rising ETC0 2 (as a patient begins to hypoventilate) can help medical and nursing staff anticipate when a patient may soon develop respiratory compromise. 3.6 If the alarm limits need to be adjusted, contact MD and report modification. 3.7 Note that monitoring respiratory rate by the assessment of chest wall movement may differ from the respiratory rate displayed on the monitor. The ETCO 2 monitor measures breaths detected from actual airflow. 3.8 If an Alaris PCA is in use, the pause PCA function may be triggered by a respiratory rate < 7. The PAUSE PCA function ceases the delivery of opioids and requires the nurse to restart the Alaris PCA at the bedside. 3.9 ETC0 2 is NOT used in terminally ill patients for which PCA is utilized and /or indicated for comfort and symptom management. 4 Indications for Interventions 4.1 If ETC0 2 is 45-50 mmhg: 4.1.1 Attempt to stimulate and arouse the patient. If patient is immediately aroused and breathing normally, monitor every 15 minutes x 1 hour. 4.1.2 Assess vital signs for decompensation (0 2 sat, BP, HR, RR, and LOC) 4.1.3 Check patient for normal signs of ventilation, assessing for hypoventilation via assessment of RR, quality and depth 4.2.2 Assess pain, level of sedation, and consider decreasing narcotic dose and/or frequency 4.1.4 Reposition the Smart CapnoLine if necessary 4.1.5 If EtC0 2 remains > 45 mmhg in spite of interventions, contact physician 4.2 If ETC0 2 is >50 mmhg or greater (In addition to the above interventions in 4.1) 4.2.3 If ETC0 2 does not return to normal within 5 minutes, call Rapid Response Team and notify MD immediately to report patient condition 4.2.4 Consider obtaining ABG (RT or RRT can also be consulted during this process) 4.2.5 If the patient does not immediately arouse, evaluate the appropriateness of administering Narcan to partially or completely reverse sedation 4.2.6 Patients may be referred to an intensive care unit when nursing staff has concerns about possible respiratory compromise. 4.3 If respiratory rate falls below 7 per minute (whether ETC0 2 is normal or not) 4.3.1 Evaluate patient for sleep apnea. Sleep apnea patients are encouraged to remain non-supine. 4.3.2 Patients can potentially have a normal EtC0 2 and low respiratory rate. In these instances it is appropriate to monitor, contact respiratory therapy or RRT if there is any question regarding accuracy of EtC0 2 measurement. 5 Care and Monitoring for Procedural Patients 5.1 When using capnography during sedation, the emphasis should be placed on significant changes from the baseline waveform or numeric ETC0 2 value rather than an absolute number. When capnography is used during administration of procedural sedation, the focus should be on baseline ETC0 2 during the procedure. 5.2 When placing Smart CapnoLine on patient, use small pieces of tape bilaterally (cheekbone area) to secure cannula in nares and over mouth. This will help to prevent movement of cannula during procedure. Capnography (ETCO2 Monitoring CPC-2013JAN-1.C.35 Page 3 of 9

5.3 Document baseline ETC0 2 value and assess waveform so changes can be identified. prior to start of procedure and during and post-procedure as per moderate sedation policy 5.4 With any significant change in ETC0 2 measurement, the first action will always be to assess the patient. 5.5 Common changes from the baseline seen during sedation and that require intervention include: 5.5.1 A change in the numerical ETC0 2 of greater than 10mm 5.5.2 A waveform that suddenly becomes erratic in shape and size 5.5.3 A waveform that becomes flat 5.6 Interventions for changes in ETC0 2 include: 5.6.1 Ensure airway is open by repositioning head and neck 5.6.2 Provide gentle stimulation if patient does not respond 5.6.3 Reposition the Smart CapnoLine if necessary 5.6.4 Stop administration of sedation and re-evaluate patient as appropriate 5.6.5 If patient is immediately aroused and breathing normally, continue to monitor 5.6.6 Administer O 2 therapy as needed per moderate sedation policy 5.6.7 If the patient does not immediately respond based on degree of sedation, consider using appropriate reversal agent per moderate sedation policy. 5.6.8 Inform MD immediately to report unanticipated changes in patient condition 6 Interpreting ETCO2 and waveforms 6.1 Interpretation of waveforms/ tracings: Capnography is a graphic representation of exhaled CO2 levels in the form of a tracing called a capnogram. Just like an EKG in which electrical activity of the heart is reflected in a distinct complex, each breath results in an individual waveform. 6.2 Each waveform represents a single respiratory cycle. The waveform has several components: 6.2.1 The first segment of the waveform is the flat area before exhalation. 6.2.2 The second segment is a sharp rise (beginning of exhalation) followed by a curve that then starts to level out. The highest portion of this part of the waveform is called the ETCO 2 point and represents exhalation of alveolar CO2. 6.2.3 The third segment is a sharp drop representing inhalation. Normal Capnography (ETCO2 Monitoring CPC-2013JAN-1.C.35 Page 4 of 9

6.3 Indicators of respiratory depression or hypoventilation: 6.3.1 ETCO 2 of > 50 6.3.2 No waveform for any period of time 6.3.4 Change in ETCO 2 of 10 below or above baseline 6.3.5 Hypoventilation: Decreased RR with an elevated ETCO 2. Waveform shape will represent a taller waveform (higher CO2) ETCO 2. May have a prolonged flat area (alveolar plateau) Hypoventilation 6.4 Shallow Breathing Hypoventilation 6.4.1 RR may or may not change with a decrease in ETCO 2. 6.4.2 Waveform shape will be abnormal in shape, shorter and smaller. It may be rounded and choppy in shape. Shallow Breathing Hypoventilation 6.5 Airway obstruction: Capnography (ETCO2 Monitoring CPC-2013JAN-1.C.35 Page 5 of 9

6.5.1 RR may or may not change with a decrease in ETCO 2. 6.5.2 Waveform shape will be abnormal with elongated upstroke or down stroke. Waveform will be shorter, rounded, and choppy. Airway Obstruction 6.6 Apnea: 6.6.1 Waveform, ETCO 2 value, and RR will be absent. 6.6.2 No air exchange is taking place due to cessation of breathing or total airway obstruction. Apnea 6.7 Rebreathing: 6.7.1 Elevated baseline. 6.7.2 Waveform shape may be normal or abnormal but key is not returning to 0 baseline. Rebreathing NOTE: ALWAYS OBTAIN A BASELINE ETCO2 AND TRACING READING PRIOR TO ADMINISTRATION OF SEDATION 6.8 Interventions if above waveforms noted: Capnography (ETCO2 Monitoring CPC-2013JAN-1.C.35 Page 6 of 9

6.8.1 Immediately assess patient 6.8.2 Ensure patent and open airway 6.8.3 Check position of cannula to ensure in nares 6.8.4 Check for secretions obstructing the prongs 6.8.5 Stimulate patient if necessary. Ask patient to take a deep breath 6.8.6 Stop drug delivery 6.8.9 Inform physician. Pause procedure if necessary 6.8.10 Administer reversal agents as indicated 7 Documentation 7.1 During acute pain management, monitor and document ETC0 2 every 1 hour until satisfactory pain control is achieved. 7.2 Once patient comfort is achieved, monitor and document ETC0 2 (and displayed respiratory rate) every four (4) hours, and more frequently as patient condition warrants. 7.3 Some conditions may suggest a need for increased monitoring and documentation. Examples of conditions that require increased monitoring are: 7.3.1 Additional boluses 7.3.2 Continuous IV or PCA basal rate 7.3.3 Risk factors for complications associated with narcotic administration such as advanced age or obesity 7.3.4 Pre-existing conditions including allergies or sleep apnea 7.3.5 Current medication use 7.4 Document all interventions performed as a result of changes in ETC0 2 and respiratory rate. 7.5 ETCO 2 values should be trended and monitored for changes and monitored and documented more frequently if values fall outside the normal range of 35 to 45mmHg. 7.6 All reports to physicians, respiratory therapy or RRT must be documented in the EMR. 8 Alarm Interpretation 7.1 Disposable disconnected: Disposable cable is removed from module during monitoring activity. 7.2 Clearing disposable: Disposable is blocked preventing adequate gas monitoring. Monitoring data is not available. 7.3 Disconnect occluded disposable: Clearing of blockage failed. Disconnect and then reconnect the disposable. 7.4 AutoZero in process: EtC0 2 module AutoZero feature is active and monitoring will be available momentarily. 7.5 Low ETC0 2 : Patient has a low carbon dioxide content in the blood. 7.5.1 Causes: 7.5.1.1 Disposable not correctly attached to patient 7.5.1.2 Disposable not securely attached to monitoring module 7.5.1.3 Low alarm limit may not be optimal for this patient 7.6 High ETC0 2 : Patient has a high carbon dioxide content in the blood. 7.6.1 Causes: 7.6.1.1 Respiratory depression 7.6.1.2 Fever 7.6.1.3 Hypermetabolic state 7.6.1.4 Disposable is not properly attached to patient 9 Changing ETC0 2 Options 9.1 Waveform Height: entire waveform of respiratory cycle should be viewable. Capnography (ETCO2 Monitoring CPC-2013JAN-1.C.35 Page 7 of 9

9.1.1 Press Channel Select on EtC0 2 module 9.1.2 Press Options (hard key) on the PC unit 9.1.3 Select Waveform Height and scale to appropriate size 9.2 Waveform Time Scale: Options are 5 or 10 seconds. If RR is rapid, the 5 second option will provide better waveform detail for viewer. If RR is normal or slow, 10 second waveform may provide better detail. 9.2.1 Press Channel Select on EtC0 2 module 9.2.2 Press Options (hard key) on the PC unit 9.2.3 Select Waveform Time Scale and select desired time scale 9.3 To view the Trended Data: 9.3.1 Press Channel Select on EtC0 2 module 9.3.2 Press Trend on main display. View will contain maximums and minimums and averages of EtC0 2 values and respiratory rates 9.3.3 To view more values, press Page Up or Page Down. 9.3.4 To change time period for data collection, select Zoom in bar above prompt display for the desired time period. Press Zoom to cycle through the choices 9.4 To view PCA and EtC0 2 Trend Data: 9.4.1 Press Channel Select on EtC0 2 module 9.4.2 Press Options (hard key) on the PC unit 9.4.3 Select PCA/ETC0 2 Trend Data 9.4.4 The Total Dose column includes all infusion data being monitored by the PCA module during that specific time frame. This includes all PCA doses, bolus doses, loading doses and continuous infusion. 9.5 Silencing Alarms: Alarms can be silenced for 2 minutes 9.5.1 Press Silence on the PC unit 9.5.2 To cancel silencing prior to the 2-minutes lock-out,, press Cancel Silence on the PC unit 10 Definitions 10.1 Capnography: Graphic display of CO 2 concentration (FCO 2 ) or expired volume during a respiratory cycle 10.2 End Tidal CO 2 Monitoring: Continuous measurement of exhaled and inhaled carbon dioxide 10.3 EtC0 2 Waveform (Capnogram): Monitor depiction of breathing pattern 10.4 Respiratory Rate: Breaths per minute 10.5 Trend Data: data is stored and trended for 24 hours and is available in a table format 11 Discontinuation 11.1 ETC0 2 monitoring may be discontinued when: 11.1.1 PCA pump is discontinued 11.1.2 6 hours after continuous epidural infusion is discontinued 11.1.3.IV narcotics discontinued 11.1.4 Per moderate sedation monitoring policy 11.2 Once ETC0 2 monitoring is discontinued, remove ETC0 2 monitor from the room and take to the soiled utility room to be picked up for cleaning. The cannula FilterLine is discarded in the same manner as regular medical waste. 12 Patient and Family Education: Patients should be informed that they are connected to a special nasal cannula that monitors breathing more accurately than a visual assessment. It measures carbon dioxide (C0 2 ) with each exhalation and monitors the respiratory rate. Some pain medications can Capnography (ETCO2 Monitoring CPC-2013JAN-1.C.35 Page 8 of 9

affect the breathing rate, possibly slowing it down. From time to time, patients should expect to hear an alarm and wake up. Instruct patients to think of the monitor as an alarm clock reminding them to breathe deeply. Committee Review: Surgical Executive committee, Medical Executive committee, Anesthesia Executive Committee, Collaborative Practice Committee References: 1 American Society of Anesthesiologists Task Force on Sedation and Analgesia by Non- Anesthesiologists. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology 2002 Apr, 96(4): 1004-17. 2 American Society of Anesthesiologists (ASA). Basic Standards for Interoperative Monitoring; 1999, and Joint Commission on Accreditation of Healthcare Organizations (JCAHO) 2001. 3 Practice guidelines for sedation and analgesia by non-anesthesiologists, an updated report by the American Society of Anesthesiologists Task Force on Sedation and Analgesia by Non- Anesthesiologists. 4 www. Capnography.com 5 www.oridion.com Capnography (ETCO2 Monitoring CPC-2013JAN-1.C.35 Page 9 of 9