Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness

Similar documents
Effective Health Care Program

Comparative Effectiveness and Safety of Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus

Insulin Delivery and Glucose Monitoring Methods: Future Research Needs. Future Research Needs Paper Number 32

Evidence-based Practice Center Systematic Review Protocol

Clinical Value and Evidence of Continuous Glucose Monitoring

Comparative Effectiveness, Safety, and Indications of Insulin Analogues in Premixed Formulations for Adults With Type 2 Diabetes Executive Summary

Diabetes Technology Continuous Subcutaneous Insulin Infusion Therapy And Continuous Glucose Monitoring In Adults: An Endocrine Society Clinical

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Continuous Glucose Monitoring (CGM)

CONTINUOUS GLUCOSE MONITORING AND INSULIN DELIVERY FOR MANAGING DIABETES

Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim

CONTINUOUS GLUCOSE MONITORING AND INSULIN DELIVERY FOR MANAGING DIABETES

Continuous Glucose Monitoring (CGM)

Diabetes Management with Continuous Glucose Monitoring & Multiple Daily Injections. Aaron Michels MD

Standards of Care in Diabetes What's New? Veronica Brady, FNP-BC, PhD, BC-ADM,CDE Karmella Thomas, RD, LD,CDE

Continuous or Intermittent Glucose Monitoring in Interstitial Fluid

Advances in Diabetes Care Technologies

Insulin Pump Therapy for Type 2

Continuous Glucose Monitoring

CONTINUOUS GLUCOSE MONITORING AND INSULIN DELIVERY FOR MANAGING DIABETES

Medical Policy. MP Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid. Related Policies None

Initiation and Titration of Insulin in Diabetes Mellitus Type 2

Corporate Medical Policy

New Hires Program Canadian Diabetes Educator Certification Board Competencies Addressed

Abstract CLINICAL APPLICATIONS. Objectives: Methods: Results: Conclusion: Journal of Diabetes Science and Technology

Advances in Diabetes Care Technologies

Update on Continuous Glucose Monitoring (CGM) Technology in Diabetes. Elena Toschi, MD November 12, 2016

This certificate-level program is non-sponsored.

Continuous Glucose Monitoring System

Continuous Glucose Monitoring System

Continuous Glucose Monitoring System

DEMYSTIFYING INSULIN THERAPY

Name of Policy: Continuous or Intermittent Monitoring of Glucose in the Interstitial Fluid

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Advances in Diabetes Care Technologies

CONTINUOUS GLUCOSE MONITORING AND INSULIN DELIVERY FOR MANAGING DIABETES

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Supplementary Appendix

CONTINUOUS GLUCOSE MONITORING AND INSULIN DELIVERY FOR MANAGING DIABETES

Diabetes: Definition Pathophysiology Treatment Goals. By Scott Magee, MD, FACE

Clinical Policy Title: Continuous interstitial glucose monitoring (CGM)

Insulin Pump Therapy in children. Prof. Abdulmoein Al-Agha, FRCPCH(UK)

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University

Basics of Continuous Subcutaneous Insulin Infusion Therapy. Lubna Mirza, MD Norman Endocrinology Associates 2018

Clinical Policy Title: Continuous interstitial glucose monitoring (CGM)

MANAGEMENT OF TYPE 1 DIABETES MELLITUS

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes. pump. pump

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes Individuals: With type 1 diabetes

CONTINUOUS GLUCOSE MONITORING AND INSULIN DELIVERY FOR MANAGING DIABETES

PREVENTION OF NOCTURNAL HYPOGLYCEMIA USING PREDICTIVE LOW GLUCOSE SUSPEND (PLGS)

Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid. Original Policy Date

Paolo Di Bartolo U.O di Diabetologia Dip. Malattie Digestive & Metaboliche AULS Prov. di Ravenna. Ipoglicemie e Monitoraggio Glicemico

In general: Hypoglycemia is common in insulin treated diabetes, but may also occur in people on oral medications, especially sulfonylureas/glinides.

The Diamond Study: Continuous Glucose Monitoring In Patients on Mulitple Daily Insulin Injections

DIAGNOSIS OF DIABETES NOW WHAT?

Type 1 Diabetes Update Robin Goland, MD

Complete Comprehensive Diabetes Educator modules available at CCCEP File #: I-P (Expires: Mar.

Continuous Glucose Monitoring in Women With Type 1 Diabetes in Pregnancy Trial

Chapter 37: Exercise Prescription in Patients with Diabetes

Diabetes Care 34: , 2011

Comparative Effectiveness and Safety of Diabetes Medications for Adults with Type 2 Diabetes

Continuous Glucose Monitoring Devices Pharmacy Policy

1. Continuous Glucose Monitoring

QUESTION 4. WHAT CLINICAL DATA ARE CURRENTLY AVAILABLE TO SUPPORT EXPANDED CGM COVERAGE BY PAYERS AS PERTAINS TO QUESTIONS 1 AND 3?

Presented by Dr. Bruce Perkins, MD MPH Dr. Michael Riddell, PhD

Janice Lazear, DNP, FNP-C, CDE DIAGNOSIS AND CLASSIFICATION OF DIABETES

The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes

Appendix A Tabular Summary of Pivotal Glucose Monitoring Trials

Policy for the Provision of Insulin Pumps for Patients with Diabetes Mellitus

Policy and Procedure DEPARTMENT: Medical Management

Protocol. Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid

Hypoglycemia a barrier to normoglycemia Are long acting analogues and pumps the answer to the barrier??

Peer Review Report. [long acting insulin analogues glargine and detemir]

Insulin Pumps and Glucose Sensors in Diabetes Management

Gestational Diabetes Mellitus Dr. Fawaz Amin Saad

Long-Term Care Updates

Limitations of Conventional Methods of Self-Monitoring of Blood Glucose

Physical Activity/Exercise Prescription with Diabetes

Vishwanath Pattan Endocrinology Wyoming Medical Center

Role of Academia In Achieving Targets in Diabetes Care

CLINICAL MEDICAL POLICY

Sponsor / Company: Sanofi Drug substance(s): insulin glargine (HOE901) According to template: QSD VERSION N 4.0 (07-JUN-2012) Page 1

Insulin Pumps - External

Treatment guideline for adult patients with type 1 diabetes?

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE GUIDANCE EXECUTIVE (GE)

Description. Section: Durable Medical Equipment Effective Date: July 15, 2014 Subsection: Original Policy Date: December 7, 2011 Subject:

Glycemic Control and Type 1 Diabetes Mellitus: Current Standard Treatment vs. Closed-Loop Insulin Pumps

Medical Policy. MP Artificial Pancreas Device Systems

Clinical Policy Title: Artificial pancreas device system

Home Blood Glucose Monitors

DIABETES ADVOCATES TAKE ACTION!

Artificial Pancreas Device System (APDS)

Management of Pregestational and Gestational Diabetes Mellitus

1. What s the point of a network the case for research? 2. How to use CSII effectively

Standards of Medical Care In Diabetes

Subject Index. Breastfeeding, self-monitoring of blood glucose 56

Abbreviations DPP-IV dipeptidyl peptidase IV DREAM Diabetes REduction Assessment with ramipril and rosiglitazone

Transcription:

Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness Prepared for: Agency for Healthcare Research and Quality (AHRQ) www.ahrq.gov

Outline of Material Introduction to insulin delivery and glucose monitoring methods for managing diabetes Systematic review methods The clinical questions addressed by the comparative effectiveness review Results of studies and evidence-based conclusions about the comparative effectiveness and safety of insulin delivery and glucose monitoring methods Gaps in knowledge and future research needs What to discuss with patients and their caregivers

Background: Definition of Diabetes Mellitus and Its Prevalence Diabetes mellitus is a group of metabolic diseases resulting from defects in insulin secretion from the pancreatic beta-cells, resistance to insulin action at the tissue level, or both. The prevalence of diagnosed diabetes in the United States is currently 7.7 percent and is expected to increase to nearly 10 percent by 2050. Type 1 diabetes accounts for 5 to 10 percent of diabetes cases in the United States; it results from the inability to produce insulin due to autoimmune destruction of pancreatic islet cells. Type 2 diabetes accounts for 90 to 95 percent of diabetes cases; it results from a combination of insulin resistance and impaired insulin secretion by pancreatic beta-cells. American Diabetes Association. Diabetes Care 2010;33 Suppl 1:S62-9. PMID: 20042775.

Background: Disease Burden of Diabetes Mellitus The hyperglycemia of diabetes, if untreated, can lead to long-term microvascular and macrovascular complications including: Retinopathy Nephropathy Neuropathy Coronary heart disease Cerebrovascular disease In pregnant women with pre-existing diabetes, poor glycemic control is associated with poorer pregnancy outcomes including: Fetal anomalies Macrosomia Stillbirth Neonatal hypoglycemia Increased referral for C-section American Diabetes Association. Diabetes Care 2010;33 Suppl 1:S62-9. PMID: 20042775.

Background: Managing Diabetes With Insulin Therapy and Glycemic Control Management of diabetes depends on the type of diabetes: For patients with type 1 diabetes, daily insulin therapy is vital. For patients with type 2 diabetes, treatment is with lifestyle modifications and/or oral medications and, if necessary, insulin. For patients requiring insulin therapy, glycemic control with intensive insulin therapy has been shown to reduce the risk of the microvascular and macrovascular complications of diabetes. For tight glycemic control, insulin is administered according to the basalbolus strategy, either via multiple daily injections (MDI) or as continuous subcutaneous insulin infusion (CSII) via an insulin pump. However, tight glycemic control can increase the risk of hypoglycemia and compromise the quality of life. Additionally, intensive insulin therapy can lead to weight gain. American Diabetes Association. Diabetes Care 2010;33 Suppl 1:S62-9. PMID: 20042775.

Background: Managing Diabetes With Glucose Monitoring and Glycemic Control (1 of 2) Long-term glycemic control (over 2 3 months) in individuals with type 1 or type 2 diabetes is assessed by measuring hemoglobin A 1c (HbA 1c ) in the blood. Strategies for monitoring blood glucose regularly and achieving glycemic control, particularly in patients using MDI or CSII, include: Self-monitoring of blood glucose (SMBG) Real-time continuous glucose monitoring (rt-cgm) The most widely used SMBG technique is the fingerstick method. rt-cgm systems provide continuous monitoring and real-time feedback to patients on their blood glucose levels. Sensor-augmented pumps that combine rt-cgm systems with CSII are also available. American Diabetes Association. Diabetes Care 2010;33 Suppl 1:S62-9. PMID: 20042775. Blevins TC, Bode BW, Garg SK, et al. Endocr Pract 2010;16(5):730-45. PMID: 21356637. Tamborlane WV, Beck RW, Bode BW, et al. N Engl J Med 2008;359(14):1464-76. PMID: 18779236.

Background: Managing Diabetes With Glucose Monitoring and Glycemic Control (2 of 2) SMBG allows timely feedback on hyperglycemia and has been shown to be a component of successful diabetes management. The American Diabetes Association (ADA) recommends that SMBG should be carried out three or more times a day in patients using MDI or CSII. Pain associated with the SMBG approach affects adherence to this technique. rt-cgm can be useful in detecting fluctuating blood glucose levels in some patient populations. According to the ADA, rt-cgm may be a supplemental tool to SMBG in patients with hypoglycemia awareness or frequent hypoglycemic episodes. Similarly, the success of rt-cgm depends on adherence to the continuous use of this device. American Diabetes Association. Diabetes Care 2010;33 Suppl 1:S62-9. PMID: 20042775. American Diabetes Association. Diabetes Care 2012;35 Suppl 1:S11-63. PMID: 22187469. Blevins TC, Bode BW, Garg SK, et al. Endocr Pract 2010;16(5):730-45. PMID: 21356637. Tamborlane WV, Beck RW, Bode BW, et al. N Engl J Med 2008;359(14):1464-76. PMID: 18779236.

Background: Uncertainties Associated With Insulin Delivery and Glucose Monitoring Methods in Managing Diabetes Mellitus The benefits and harms of insulin delivery with CSII versus MDI in patients with type 1 or type 2 diabetes and in pregnant women with pre-existing diabetes are not completely known. Additionally, the relative benefits of glucose monitoring with SMBG versus rt-cgm in these populations have not been thoroughly evaluated. Given the new technologies in insulin delivery and glucose monitoring, clinicians are faced with challenges in determining which modalities are most beneficial to their patients. Therefore, the comparative effectiveness and/or adverse effects of the modes of insulin delivery (CSII vs. MDI) and glucose monitoring (rt-cgm vs. SMBG) requires systematic review.

Agency for Healthcare Research and Quality (AHRQ) Comparative Effectiveness Review (CER) Development Topics are nominated through a public process, which includes submissions from health care professionals, professional organizations, the private sector, policymakers, lay persons, and others. A systematic review of all relevant clinical studies is conducted by independent researchers, funded by AHRQ, to synthesize the evidence in a report summarizing what is known and not known about the select clinical issue. The research questions and the results of the report are subject to expert input, peer review, and public comment. The results of these reviews are summarized into Clinician Research Summaries and Consumer Research Summaries for use in decisionmaking and in discussions with patients. The Research Summaries and the full report, with references for included and excluded studies, are available at

Clinical Questions Addressed by the Comparative Effectiveness Review (1 of 2) Key Question 1: In patients receiving intensive insulin therapy, does mode of delivery (CSII vs. MDI) have a differential effect on process measures, intermediate outcomes, and clinical outcomes in patients with diabetes mellitus? Do these effects differ by: a. Type 1 or type 2 diabetes status? b. Age: very young children, adolescents, and adults, including older adults (age >65 years)? c. Pregnancy status: pre-existing type 1 or type 2 diabetes?

Clinical Questions Addressed by the Comparative Effectiveness Review (2 of 2) Key Question 2: In patients using intensive insulin therapy (MDI or CSII), does the type of glucose monitoring (rt-cgm vs. SMBG) have a differential effect on process measures, intermediate outcomes, and clinical outcomes in patients with diabetes mellitus (i.e., what is the incremental benefit of rt-cgm in patients already using intensive insulin therapy)? Do these effects differ by: a. Type 1 or type 2 diabetes status? b. Age: very young children, adolescents, and adults, including older adults (age >65 years)? c. Pregnancy status: pre-existing type 1 or type 2 diabetes? d. Intensive insulin delivery: MDI or CSII?

Rating the Strength of Evidence From the Comparative Effectiveness Review The strength of evidence was classified into four broad categories: Strength of evidence High Moderate Low Insufficient Meaning High confidence that the evidence reflects the true effect. Further research is very unlikely to change the confidence in the estimate of effect. Moderate confidence that the evidence reflects the true effect. Further research may change the confidence in the estimate of effect and may change the estimate. Low confidence that the evidence reflects the true effect. Further research is likely to change the confidence in the estimate of effect and is likely to change the estimate. Evidence either is unavailable or does not permit estimation of an effect.

Insulin Delivery With MDI Versus CSII in Children and Adolescents With Type 1 Diabetes HbA 1c lowering did not differ significantly between CSII and MDI (mean difference from baseline, -0.14%; 95% confidence interval [CI], -0.48 to 0.20; p = 0.41). Strength of Evidence: Moderate Frequency of daytime hypoglycemia, frequency of nocturnal hypoglycemia, rate of severe hypoglycemia, weight gain, and quality of life did not differ significantly between CSII and MDI. Strength of Evidence: Low CSII was associated with a significant improvement in diabetes treatment satisfaction versus MDI (mean difference, 5.7; 95% CI, 5.0 to 6.4; p < 0.001). Strength of Evidence: Low

Insulin Delivery With MDI Versus CSII in Adults With Type 1 Diabetes CSII resulted in a significant HbA 1c -lowering effect when compared with MDI (mean difference from baseline, -0.30%; 95% CI, -0.58 to -0.02), although results were heavily influenced by one study. Strength of Evidence: Low Frequency of nocturnal hypoglycemia, severe hypoglycemia, other nonsevere hypoglycemia, hyperglycemia, and weight gain did not differ significantly between CSII and MDI. Strength of Evidence: Low CSII resulted in a small decrease in postprandial glucose and an increase in symptomatic hypoglycemia when compared with MDI. Strength of Evidence: Low CSII was associated with a significant improvement in diabetes-specific quality of life when compared with MDI (mean difference, 2.99; 95% CI, 0.006 to 5.97; p = 0.05). Strength of Evidence: Low

Insulin Delivery With MDI Versus CSII in Adults With Type 2 Diabetes HbA 1c lowering did not differ significantly between MDI and CSII (mean difference from baseline, -0.16%; 95% CI, -0.42 to 0.09; p = 0.21). Strength of Evidence: Moderate The risk of mild hypoglycemia was lower with CSII versus MDI; however, there was no significant difference between the two groups (combined relative risk, 0.90; 95% CI, 0.78 to 1.03). Strength of Evidence: Moderate No significant between-group differences in frequency of severe hypoglycemia or in weight gain were observed in this population. Strength of Evidence: Low

Insulin Delivery With MDI Versus CSII in Pregnant Women With Pre-existing Diabetes HbA 1c improved in both the CSII and MDI arms in all three trimesters, with no significant differences between the two arms. Strength of Evidence: Low The strength of evidence for all other findings related to pregnant women with pre-existing diabetes (including maternal hypoglycemia, maternal weight gain, rate of cesarean sections, and neonatal outcomes) were rated as insufficient.

Glucose Monitoring With rt-cgm Versus SMBG in Children and Adults With Type 1 Diabetes rt-cgm was associated with a significant HbA 1c -lowering effect when compared with SMBG (mean difference from baseline, -0.30%; 95% CI,-0.37 to -0.22%; p < 0.001). Strength of Evidence: High Time spent in the hypoglycemic range was similar in the rt-cgm and SMBG groups (mean difference, 2.11 minutes/day; 95% CI, -5.66 to 1.44 minutes/day). Strength of Evidence: Moderate A significant reduction in the time spent in the hyperglycemic range occurred with rt- CGM when compared with SMBG (-68.56 minutes/day; 95% CI, -101.17 to -35.96). Strength of Evidence: Moderate The evidence was inconsistent for the effect of rt-cgm versus SMBG on the ratio of basal to bolus insulin in a daily insulin dose. Strength of Evidence: Low The rt-cgm and SMBG groups exhibited similar rates of severe hypoglycemia, general quality of life and diabetes-specific quality of life. Strength of Evidence: Low

Glucose Monitoring With rt-cgm Plus CSII (Sensor-Augmented Pump) Versus MDI Plus SMBG in Children and Adults With Type 1 Diabetes (1 of 2) Using a sensor-augmented pump is associated with a significant HbA 1c -lowering effect when compared with SMBG in children and adults with type 1 diabetes (mean difference from baseline, -0.68%; 95% CI, -0.81 to -0.54%; p < 0.001). Strength of Evidence: Moderate Time spent with nonsevere hypoglycemia and incidence of severe hypoglycemia were similar between the sensor-augmented pump and the MDI/SMBG groups. Strength of Evidence: Moderate

Glucose Monitoring With rt-cgm Plus CSII (Sensor-Augmented Pump) Versus MDI Plus SMBG in Children and Adults With Type 1 Diabetes (2 of 2) Overall diabetes treatment satisfaction was greater among participants in the sensor-augmented pump arm when compared with the MDI/SMBG arm; there is no significant difference in weight gain between the two arms. Strength of Evidence: Low Evidence from two randomized controlled trials suggests that time spent with hyperglycemia is significantly lower in the sensoraugmented pump group versus the MDI/SMBG group (p < 0.001). Strength of Evidence: Moderate

Conclusions Both CSII and MDI had similar effects on glycemic control and rates of severe hypoglycemia in children and adolescents with type 1 diabetes and adults with type 2 diabetes. In contrast, some studies suggested that CSII was superior to MDI for glycemic control in adults with type 1 diabetes with no difference in hypoglycemia and weight gain. Limited evidence suggested that measures of quality of life or treatment satisfaction improved in patients with type 1 diabetes. The approach to intensive insulin therapy can, therefore, be individualized to patient preference to maximize quality of life. rt-cgm was superior to SMBG in lowering HbA 1c, without affecting the risk of severe hypoglycemia, in nonpregnant individuals with type 1 diabetes. This effect was greater when compliance with rt-cgm was high. Sensor-augmented pumps were superior to MDI/SMBG in lowering HbA 1c in the research studies analyzed in this review. However, other combinations of these insulin delivery and glucose monitoring modalities were not evaluated.

Knowledge Gaps and Future Research Needs (1 of 3) Most randomized controlled trials identified in the literature for inclusion in this review were small. Most studies were fair to poor in quality and did not report most outcomes of interest. Most studies did not report the racial and ethnic composition of the study populations; for those that did, most participants were white. Few studies focused on, or included, children 12 years of age or younger or adults 65 years of age or older. The studies included in this review varied widely in their definitions of nonsevere hypoglycemia, hyperglycemia, and weight gain, thus preventing definitive conclusions about the effects of insulin delivery and glucose monitoring strategies on these outcomes.

Knowledge Gaps and Future Research Needs (2 of 3) None of the studies included data on the long-term microvascular and macrovascular complications of diabetes. The studies in pregnant women with pre-existing type 1 diabetes did not examine the effect of rt-cgm on maternal and fetal outcomes. Most of the included studies, particularly those comparing MDI with CSII, did not report on the extent of treatment adherence, which may have biased the results. The studies were not uniform in assessing and reporting quality-oflife outcomes, thus precluding quantification of the effects of insulin delivery and glucose monitoring devices on quality of life.

Knowledge Gaps and Future Research Needs (3 of 3) Several studies excluded individuals with comorbidities, thereby limiting the applicability of the results to the entire population. The identified gaps in this review highlight the need for future welldesigned studies with: Large study populations including all age-groups and diverse ethnicities Long followup periods Standard outcome measures, including measures of vascular complications and quality of life Studies of pregnant women with pre-existing type 1 and type 2 diabetes

What To Discuss With Your Patients and Their Caregivers (1 of 2) The type of his/her diabetes and the potential role of insulin therapy in its treatment The role of other lifestyle changes in managing the patient s diabetes The importance of glycemic control in managing the patient s diabetes The role of routine blood glucose monitoring in maintaining appropriate glycemic control and in managing the patient s diabetes The importance of having a sick-day regimen in order to avoid extreme hypoglycemic or hyperglycemic episodes in times of illness or inability to eat The available strategies for insulin delivery and blood glucose monitoring

What To Discuss With Your Patients and Their Caregivers (2 of 2) The available evidence for the effectiveness of MDI versus CSII for insulin delivery The available evidence for the effectiveness of SMBG versus rt-cgm for glucose monitoring The patient s preferences with regard to the mode of insulin delivery and glucose monitoring The available evidence for the effectiveness of rt-cgm plus CSII (sensor-augmented pump) versus MDI/SMBG The potential risks associated with intensive insulin therapy such as hypoglycemic events and weight gain, their impact on quality of life, and strategies for their management The potential out-of-pocket costs that the patient might incur based on his/her insurance coverage with each option.