IMPROVING THE PATIENT EXPERIENCE IN NOISE: FAST-ACTING SINGLE-MICROPHONE NOISE REDUCTION

Similar documents
ReSound NoiseTracker II

Evidence base for hearing aid features:

Can you hear me now? Amanda Wolfe, Au.D. Examining speech intelligibility differences between bilateral and unilateral telephone listening conditions

UvA-DARE (Digital Academic Repository) Perceptual evaluation of noise reduction in hearing aids Brons, I. Link to publication

Sonic Spotlight. SmartCompress. Advancing compression technology into the future

X Series Digital Hearing Products

2/16/2012. Fitting Current Amplification Technology on Infants and Children. Preselection Issues & Procedures

X SERIES DIGITAL HEARING PRODUCTS

Abstract.

Course Syllabus. Office: J210 Phone: Cell: Office hours: by appointment

Wi Series Wireless Hearing Products

Binaural Processing for Understanding Speech in Background Noise

3 SERIES WIRELESS HEARING PRODUCTS

Should digital noise reduction be activated in pediatric hearing-aid fittings?

Anthem XT Digital Hearing Products

Best Practice Protocols

Sound Check: Essentials of a Hearing Screener

NuEar SDS - Wireless Hearing Products

Proceedings of Meetings on Acoustics

Better hearing is right here, right now.

Muse Wireless CROS System

Wireless Hearing Products

Wireless Hearing Products

Wireless Hearing Products

SoundRecover2 the first adaptive frequency compression algorithm More audibility of high frequency sounds

Putting the focus on conversations

Environmentally Aware Feature-Packed DSP Hearing Aid Amplifier ACOUSTIC SCENE ANALYSIS AUDIOLOGY BACKGROUND

The Role of Aided Signal-to-Noise Ratio in Aided Speech Perception in Noise

Juan Carlos Tejero-Calado 1, Janet C. Rutledge 2, and Peggy B. Nelson 3

Audiology Today MarApr2011

Anna KARCZEWSKA NABELEK

Sonic Spotlight. Binaural Coordination: Making the Connection

Make the world louder!

ReSound LiNX 3D The future is here a new dimension in hearing care

Andres, A. M.Cl.Sc (AUD.) Candidate The University of Western Ontario: School of Communication Sciences and Disorders

For hearing aid noise reduction, babble is not just babble

Using QuickSIN Speech Material to Measure Acceptable Noise Level for Adults with Hearing Loss

WIDEXPRESS. no.30. Background

Clinical Tips for Matching Real-Ear Prescriptive Targets

Open up to the world. A new paradigm in hearing care

Curriculum Vitae for Benjamin W.Y. Hornsby

Jing Shen CURRICULUM VITAE Contact Information Education Academic and Research Experience

Oticon Product portfolio 2010

TOPICS IN AMPLIFICATION

Supplementary Online Content

New Technology for Effortless Hearing: A Unique Perspective

Guidelines for determining hearing aid output, hearing aid features, and fitting parameters for children. Jace Wolfe, PhD


Editorial Hearing Aids and the Brain

Annoyance and Hearing Aids Donald J. Schum, Ph.D. Vice President of Audiology & Professional Relations for Oticon, Inc

Baker, A., M.Cl.Sc (AUD) Candidate University of Western Ontario: School of Communication Sciences and Disorders

CROS SYSTEM. Hearing solutions for single-sided hearing loss

ABSTRACT INTRODUCTION

FREQUENCY COMPOSITION : A NEW APPROACH TO FREQUENCY- LOWERING

Topics in Amplification DYNAMIC NOISE MANAGEMENT TM A WINNING TEAM

WHEREVER SOUND IS A PROBLEM, SOUNDGEAR CAN HELP

Research Article The Acoustic and Peceptual Effects of Series and Parallel Processing

Slow compression for people with severe to profound hearing loss

The Oticon Alta Fitting Approach

IMPROVE YOUR NEXT HEARING AID EXPERIENCE WITH HEARING TRACKER. Abram Bailey, AuD Hearing Tracker, Inc President

CROS SYSTEM. Hearing solutions for single-sided hearing loss

Hearing Aids and Assistive Listening Devices

CROS System. Hearing solutions for single-sided hearing loss

Hearing solutions for single-sided hearing loss

SpeechZone 2. Author Tina Howard, Au.D., CCC-A, FAAA Senior Validation Specialist Unitron Favorite sound: wind chimes

C H A N N E L S A N D B A N D S A C T I V E N O I S E C O N T R O L 2

HearIntelligence by HANSATON. Intelligent hearing means natural hearing.

Starkey Laboratories, Inc Washington Avenue South Eden Prairie, MN

Best practices in A few favorite resources: Clear areas of agreement: How about these features? The bottom line:

Speech perception in individuals with dementia of the Alzheimer s type (DAT) Mitchell S. Sommers Department of Psychology Washington University

Industry Emphasis. Hearing Aids. Basic Design and Function. Hearing Aid Types. Hearing Aid Types. Hearing Aid Types.

Topics in Amplification CONNECTIVITY COMMUNICATION WITHOUT LIMITS

Thrive Hearing Control App User Guide for Apple. Congratulations on your journey to better hearing

Chapter 7 CONCLUSION AND RECOMMENDATIONS

Group Delay or Processing Delay

Computational Perception /785. Auditory Scene Analysis

CHAPTER 1 INTRODUCTION

Complimentary Author PDF: Not for Broad Dissemination AJA. Research Article

Early Adjustment to Amplification Results in Better Outcome Later On Steven L. Benton, Au.D.

Initial-Fit Algorithm vs. Probe- Microphone Verification: Comparing Self-Perceived Benefit

Oticon Agil success 2011 An International Survey

THE SMARTEST RECHARGEABLE

WIDEXPRESS THE WIDEX FITTING RATIONALE FOR EVOKE MARCH 2018 ISSUE NO. 38

HI-FIDELITY BROUGHT TO YOU BY TUNZ

Hearing Control App User Guide

Audiologic management of adult hearing impairment

Fabricating Reality Through Language

HCS 7367 Speech Perception

personalization meets innov ation

Amplitude Compression: Timing is Everything

C HAPTER T WENTY-TWO

Insio: A new standard in custom instruments

NHS HDL(2004) 24 abcdefghijklm

HCS 7367 Speech Perception

Evidence-based Design Leads to Remote Microphone Hearing Instrument Technology

Hearing Solutions Catalog Winter Supplement January 2009

Product Portfolio Supplement

2010 Spring Webinar Series

Digital. hearing instruments have burst on the

Transcription:

IMPROVING THE PATIENT EXPERIENCE IN NOISE: FAST-ACTING SINGLE-MICROPHONE NOISE REDUCTION Jason A. Galster, Ph.D. & Justyn Pisa, Au.D. Background Hearing impaired listeners experience their greatest auditory challenges when listening in noise (Plomp, 1994; Kochkin, 22). For this reason, developers of hearing instruments have made improving patient satisfaction when listening in noise an important goal. This paper introduces Voice iq, a new Digital Noise Reduction (DNR) algorithm available in the Starkey S Series iq family of hearing instruments. Originally developed at the Starkey Hearing Research Center, Voice iq has undergone numerous research and clinical trial evaluations. These studies quantified two outcomes: first, ensuring that the aggressive noise suppressing nature of Voice iq does not degrade speech quality or understanding, and second, demonstrating improved ease of listening in noise. A review of the research literature shows that DNR algorithms may improve comfort and sound quality when listening in noise (Bentler & Chiou, 26; Mueller, Weber, & Hornsby, 26; Ricketts & Hornsby, 25). Listeners may also experience a decrease in listening effort as a result of DNR when listening in noise (Sarampalis, Kalluri, Edwards, Hafter, 29). Sarampalis and colleagues suggest that reducing listening effort through the use of a DNR algorithm may improve a patient s ability to focus on a secondary task. This hypothesis originates from the theory that attention is drawn from a single, finite, cognitive resource (Baddeley, 1998). In other words, if a DNR algorithm can reduce the effort required to understand speech in noise, the hearing impaired listener will be able to allocate more cognitive resources to a secondary task. Additionally, an idealized goal of any DNR algorithm would be the improvement of speech recognition in noise; however, research in this area suggests that patients may experience improved, decreased, or unchanged speech understanding, depending upon the test conditions (Galster & Ricketts, 24; Mueller et al., 26). The apparent lack of consistency throughout the literature reinforces the fact that improved speech understanding remains an elusive goal for DNR. However, because modern DNR algorithms reduce output in order to manage undesirable noise, it follows that a poorly designed algorithm risks degrading speech cues and compromising the audibility of speech. Improving the Patient Experience in Noise: Fast-Acting Single-Microphone Noise Reduction 1

Digital Noise Reduction Behavior Traditional DNR algorithms have worked in a binary manner when processing speech and noise. If noise is the dominant signal in a hearing aid channel, a traditional DNR algorithm reduces gain in that channel by a specified amount; when speech is the dominant signal, the prescribed gain is unaffected. If the DNR algorithm responds slowly, the result is DNR that is inactive in the presence of speech and only active in high levels of noise. Voice iq benefits from voice-finding technology that allows for near-instantaneous classification of desired speech or unwanted noise. The fast and accurate identification of speech allows Voice iq to analyze and adapt at speeds fast enough to reduce segments of noise within sentences and speech. Figure 1 is an illustration of overlapping noise (red) and speech (black). Voice iq uses a number of cues, such as signal-to-noise ratio, overall level and signal modulation to classify acoustic environments. Speech is highly modulated whereas noise is typically more steady-state in nature. The modulations of speech allow Voice iq to identify noise as it becomes the dominant signal during the gaps in speech. When noise is identified in any channel, the gain in that channel is quickly reduced and reapplied as soon as the speech signal returns this behavior is illustrated in Figure 2. In the case of fast-acting DNR algorithms such as Voice iq, special consideration must be made to avoid the reduction of speech cues. Time Figure 1. Illustration of a noise waveform in red, overlapping a speech waveform in black. Time Figure 2. Illustration of noise in red, overlapping a speech waveform in black. This illustration demonstrates the behavior of Voice iq to suppress noise between gaps in running speech Evaluation of Digital Noise Reduction Algorithms Developed at the Starkey Hearing Research Center, Voice iq underwent a battery of sound quality studies throughout research and development. Individual parameters of the algorithm were adjusted to accommodate the listening preferences of patients and to ensure that the algorithm was appropriately targeting noise in the gaps of speech. These early studies were completed prior to the implementation of the Voice iq in a hearing aid. By focusing early development outside of the hearing aid platform, appropriate adjustments were easily made. After establishing algorithm parameters that ensured patient success in a laboratory setting, the next step was clinical validation of Voice iq in the S Series iq hearing aid. The successful transfer of Voice iq to the Starkey S Series iq hearing aids was validated through systematic clinical research. Forty-four hearing impaired adults participated in a comprehensive clinical trial. Detailed results of this clinical trial are presented and discussed by Pisa, Burk, and Galster (In Press). In their study, the authors found that the S Series iq hearing aids significantly improved patient s ability to tolerate noisy environments. Participants also reported reduced listening effort, as measured by the Device-Oriented Subjective Outcome Scale (DOSO) (Cox, Alexander & Xu, 29), with the test devices when compared to their own hearing aids. Preservation of Speech in Noise A system that is designed to reduce noise between gaps in speech must also retain the integrity of the valuable speech signal. Because speech modulations occur over a period of milliseconds, this can be a challenging task. If hearing aid output is reduced during gaps in speech, appropriately prescribed gain must be reapplied to the speech signal when it returns. A poorly designed noise reduction algorithm may not accurately track speech modulations, thereby compromising the integrity of the speech signal. A major design focus of Voice iq was to ensure the preservation of these speech cues while aggressively reducing noise. An electroacoustic benchmarking evaluation developed by Hagerman and Olofsson (24) was used to illustrate the speech-preserving capability of Voice iq. This evaluation method allows for the extraction of speech from a background of noise after processing through a digital noise reduction algorithm. For the purpose of this paper, the extracted waveforms are used to provide a qualitative visual example of how digital noise reduction algorithms implemented in today s hearing aids may distort or reduce speech when presented in background noise. The test method developed by Hagerman and Olofsson (24) is described in an excerpt from their publication: Our approach is to present speech and noise simultaneously and make two measurements, one of them with the noise phase reversed. Taking the sum of the corresponding two output signals, or the difference, the output speech or the output noise can be extracted. Thus, the gain can be calculated for each of them, although they are present at the same time and influence the signal processing of the hearing aid in a normal way. (p. 356) 2 Improving the Patient Experience in Noise: Fast-Acting Single-Microphone Noise Reduction Improving the Patient Experience in Noise: Fast-Acting Single-Microphone Noise Reduction 3

Figures 3 and 4 show speech waveforms extracted from a background of noise using the Hagerman and Olofsson benchmarking evaluation. In Figure 3, a fast-acting noise reduction algorithm, currently available from a leading hearing instrument manufacturer, was used to process the speech and noise signals. In figure 3, it is readily apparent that the speech peaks have been compromised by the noise-reduction algorithm. Figure 4, shows the effect of Voice iq on the same speech and noise samples. The lack of difference between the dark blue and light blue wave forms highlights the success of Voice iq in maintaining the integrity of the speech signal, even while effectively reducing noise levels. It was important to reinforce the electroacoustic evaluation of Voice iq with perceptual measures of speech understanding. Forty-four hearing impaired adults completed the Nonsense Syllable Test (NST) (Resnick,Dubno, Hoffnung & Levitt, 1975) after being fit with S Series iq hearing aids, the results of which are shown in Figure 5. The mean group performance without Voice iq was 54.1 percent correct, with Voice iq activated the mean performance of the same group was 55.4 percent correct, a difference of 1.3 percentile points. A one-way repeated-measures analysis of variance with a Bonferroni correction for multiple comparisons showed this difference to be insignificant (p>.5); the absence of a significant difference indicates that even when evaluating easily degraded high-frequency speech components, Voice iq retains the integrity of that speech signal..3.2.1 -.1 -.2 -.3 A On.5 1 1.5 2 Time (Sec.) A Off Figure 3. Two speech waveforms are shown, the dark blue is speech processed through a hearing aid with no noise reduction, the light blue waveform is speech processed through a commercially available digital noise reduction algorithm. Both examples are extracted from a background of noise using the Hagerman and Olofson (24) evaluation technique. The lightblue waveform shows the effect of a competitive digital noise reduction algorithm on the speech waveform..8.6.4.2 -.2 -.4 -.6 -.8 Voice iq On.5 1 1.5 2 Time (Sec.) Voice iq Off Figure 4. Two speech waveforms are shown, the dark blue is speech processed through the S Series iq with no noise reduction, the light blue waveform is speech processed through the same S Series iq with Voice iq active. Both examples are extracted from a background of noise using the Hagerman and Olofson (24) evaluation technique. The lightblue waveform shows the minimal effect of Voice iq on the speech waveform. Percent Correct 1 9 8 7 6 5 4 3 2 1 Without IQ With Voice IQ Figure 5. Percent correct on the nonsense syllable test (NST) with and without Voice iq digital noise reduction processing. Summary Data collected from over 4 hearing-impaired research participants have demonstrated the benefits of Voice iq and the S Series iq hearing aids. Based on these findings, professionals fitting an S Series iq instrument, can expect patients to experience improved comfort and ease of listening in noise without sacrificing valuable speech cues. Documenting and understanding the benefits of digital noise reduction has challenged the hearing aid industry for years. This new body of data surrounding Voice iq and the S Series iq family of hearing aids helps to establish clinical expectations for modern digital noise reduction. By ensuring the integrity of speech, while documenting patient preferences and benefits, Voice iq represents the paradigm of an evidence-based design. Acknowledgements We would like to thank Matthew Burk, Elizabeth Galster, Laurel Gregory, Ivo Merks, and Tao Zhang for developing the studies and completing the collection of data that support the information provided in this document. 4 Improving the Patient Experience in Noise: Fast-Acting Single-Microphone Noise Reduction Improving the Patient Experience in Noise: Fast-Acting Single-Microphone Noise Reduction 5

References Baddeley, A. D. (1998). The central executive: A concept and some misconceptions. Journal of the Neuropsychological Society, 4, 523 526. Bentler, R., & Chiou, L.K. (26). Digital noise reduction: An overview. Trends in Amplification, 1(2), 67-82. Cox, RM, Alexander, GC, & Xu, J. (29). Development of the Device Oriented Subjective Outcome Scale (DOSO). Refereed poster presented at the Annual Meeting of the American Auditory Society, Scottsdale, AZ, March, 29. Galster, J.A., & Ricketts, T.A., (24). The effects of digital noise reduction time constants on speech recognition in noise. Poster presented at the International Hearing Aid Convention. Lake Tahoe, CA, September, 24. Hagerman, B., & Olofson, A. (24). A method to measure the effect of noise reduction algorithms using simultaneuous speech and noise. Acta Acustica, 9, 356-361. Kochkin, S. (22). 1-Year Customer Satisfaction Trends in the US Hearing Instrument Market. Hearing Review, 9(1), 14-25, 46. Mueller, G.H., Weber, J., & Hornsby, B.W.Y. (26). The effects of digital noise reduction on the acceptance of background noise. Trends in Amplification, 1(83), 83-93. Pisa, J., Burk, M., & Galster, E. (In Press). Evidence based design of a noise management algorithm. The Hearing Journal Plomp, R. (1994). Noise, amplification, and compression: Considerations of 3 main issues in hearing-aid design. Ear and Hearing, 15, 2 12. Resnick, S.B., Dubno, J.R., Hoffnung, S., & Levitt, H. (1975). Phoneme errors on a nonsense syllable test. Journal of the Acoustical Society of America, 58, 114. Ricketts, T.A., & Hornsby, B.W.Y. (25). Sound quality measures for speech in noise through a commercial hearing aid implementing digital noise reduction. Journal of the American Academy of Audiology, 16(5), 27-277. Sarampalis, A., Kalluri, S., Edwards, B., & Hafter, E. (29). Objective measures of listening effort: Effects of background noise and noise reduction. Journal of Speech Language and Hearing Research, 52, 123-124. 6 Improving the Patient Experience in Noise: Fast-Acting Single-Microphone Noise Reduction Improving the Patient Experience in Noise: Fast-Acting Single-Microphone Noise Reduction 7

A global hearing technology company headquartered in Eden Prairie, Minnesota, U.S.A. Starkey Laboratories, Inc. 67 Washington Avenue South Eden Prairie, MN 55344-3476 8.328.862 StarkeyPro.com 21 Starkey Laboratories, Inc. All Rights Reserved. 84458-3/1 WTPR6--EE-ST