Increased Identification Coverage and Throughput for Complex Lipidomes

Similar documents
High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Thermo Scientific LipidSearch Software for Lipidomics Workflows. Automated Identification and Relative. Quantitation of Lipids by LC/MS

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Integrated Targeted Quantitation Method for Insulin and its Therapeutic Analogs

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

LC-MS/MS Method for the Determination of Tenofovir from Plasma

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D

Identification and Quantitation of Microcystins by Targeted Full-Scan LC-MS/MS

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

Impurity Profiling of Carbamazepine by HPLC/UV

Essential Lipidomics Experiments using the LTQ Orbitrap Hybrid Mass Spectrometer

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Thermo Fisher Scientific, Sunnyvale, CA, USA; 2 Thermo Fisher Scientific, San Jose, CA, USA

Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase

Supporting information

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

PIF: Precursor Ion Fingerprinting Searching for a Structurally Diagnostic Fragment Using Combined Targeted and Data Dependent MS n

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Glycerolipid Analysis. LC/MS/MS Analytical Services

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer

Supporting Information

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

New Mass Spectrometry Tools to Transform Metabolomics and Lipidomics

Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

Using Multiple Mass Defect Filters and Higher Energy Collisional Dissociation on an LTQ Orbitrap XL for Fast, Sensitive and Accurate Metabolite ID

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

A Rapid UHPLC Method for the Analysis of Biogenic Amines and Metabolites in Microdialysis Samples

A Fully Integrated Workflow for LC-MS/MS Analysis of Labeled and Native N-Linked Glycans Released From Proteins

Enhancing Sequence Coverage in Proteomics Studies by Using a Combination of Proteolytic Enzymes

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

SYNAPT G2-S High Definition MS (HDMS) System

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

New Instruments and Services

Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Dynamic Analysis of HIV-Human Protein-Protein Interactions During Infection

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

LC/MS Method for Comprehensive Analysis of Plasma Lipids

The use of mass spectrometry in lipidomics. Outlines

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection

FT-Raman Surface Mapping of Remineralized Artificial Dental Caries

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Don t miss a thing on your peptide mapping journey How to get full coverage peptide maps using high resolution accurate mass spectrometry

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Mass Spectrometry based metabolomics

Robust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS

Analysis of Phospholipids in Natural Samples by Normal Phase HPLC and Corona Charged Aerosol Detection

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

PosterReprint OVERVIEW

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Edgar Naegele. Abstract

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin

Supporting information

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

LC-MS/MS Method for the Determination of Raloxifene and its Glucuronide Metabolites from Human Plasma Using SPE Micro Elution

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Characterization of an Unknown Compound Using the LTQ Orbitrap

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform

Join the mass movement towards mass spectrometry

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Chemical Analysis Business Operations Waters Corporation Milford MA

Amadeo R. Fernández-Alba

Mercury Speciation Determinations in Asian Dietary Supplements

More structural information with MS n

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

Carl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA

Determination of Amantadine Residues in Chicken by LCMS-8040

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Choosing the metabolomics platform

Nitrogen/Protein Determination in Starch by Flash Combustion using Large Sample Weight as an Alternative to the Kjeldahl Method

Sample Concentration and Analysis of Human Hormones in Drinking Water

Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution

Internal Calibration System of Thermo Scientific Varioskan Flash with Improved Sensitivity, Accuracy and Dynamic Range

Ultra High Definition Optimizing all Analytical Dimensions

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

Transcription:

Increased Identification Coverage and Throughput for Complex Lipidomes Reiko Kiyonami, David Peake, Yingying Huang, Thermo Fisher Scientific, San Jose, CA USA Application Note 607 Key Words Q Exactive HF, high resolution, accurate mass, lipids, LipidSearch, parallel reaction monitoring, untargeted lipidomics, targeted lipidomics Goal To achieve improved lipid identification, quantification, and throughput from complex biological samples by employing a hybrid quadrupole-orbitrap mass spectrometer with greater mass resolution and scan speed. Introduction Lipidomics as a branch of metabolomics is a systemsbased study of all lipid molecules within a biological system, tissue, or cell. Lipids are the main structural components of biological membranes, a major form of energy storage in cells, but are also well-known mediators of cell signaling. In order to understand cellular physiology and pathophysiology, comprehensive identification and precise quantification of lipids is crucial in lipidomics research. 1 Recent advances in high-performance liquid chromatography-mass spectrometry (HPLC-MS) platforms allow the rapid and sensitive detection of a variety of lipid species with minimal sample preparation. However, two main challenges remain. First, the lipidome is highly complex. It includes eight major categories, over 80 major classes, 300 sub-classes, and thousands of lipid species 2 spanning a wide range of concentrations. HPLC cannot separate all of the isomeric and isobaric molecular ions in a typical biological sample. In order to obviate interference from the co-eluting species, an ultra-highresolution, accurate-mass mass spectrometer is required for accurate lipid molecular ion determination. Second, molecular weight information alone is not always sufficient to identify each isomer of an individual lipid species. MS/MS (or sometimes even MS n ) information is often required for unambiguous identification of each individual lipid species in biological samples. The Thermo Scientific Q Exactive HF hybrid quadrupole-orbitrap mass spectrometer features an ultra-high-field Orbitrap analyzer, which doubles data acquisition speed and mass resolution compared to the first generation of Orbitrap analyzer (Figure 1). The ultrahigh resolution (up to 240,000, FWHM at m/z 200) of the Q Exactive HF MS allows simultaneous accuratemass measurement with better than 3 ppm accuracy with external calibration. The faster scan speed (up to 18 Hz) of the Q Exactive HF MS results in a higher number of precursor ions triggered for MS/MS. As a result, more lipid identifications in a single HPLC-MS/MS run can be achieved with improved sensitivity, accuracy, and productivity. The Q Exactive HF MS also allows multiple high-resolution, accurate-mass approaches, including full MS, selected-ion monitoring (SIM), and parallel-reaction monitoring (PRM), for highly sensitive and selective quantification of individual lipid species of interest. In this study, a Q Exactive HF MS was used to: (i) identify lipids from multiple complex biological lipid extracts (ii) identify large number of lipids and provide simultaneous qualitative and quantitative information in a complex lipidome and (iii) determine linear dynamic range, limit of detection (LOD), and limit of quantitation (LOQ) for specific lipid species of interest.

2 HPLC Method A Thermo Scientific Dionex UltiMate 3000 Rapid Separation LC (RSLC) system was used for separations with the gradient conditions shown in Table 1. 3 Mobile phase A was 60:40 acetonitrile/water and mobile phase B was 90:10 isopropyl alcohol/acetonitrile; both A and B contained 10 mm ammonium formate and 0.1% formic acid. The column was an Ascentis Express C18 (Sigma-Aldrich, 2.1 x 100 mm, 2.7 µm) operated at 55 C and a flow rate of 260 µl/min. The injection volume was 2 µl. Table 1. LC separation conditions Mass Range 50 < m/z < 6,000 Resolution @ m/z 200 Mass Accuracy Polarity Switching 15,000 at 18 Hz 30,000 at 12 Hz 60,000 at 7 Hz 120,000 at 3 Hz 240,000 at 1.5 Hz < 1 ppm RMS, Internal Calibration < 3 ppm RMS, External Calibration One full cycle in < 1 sec (one full positive mode scan and one full negative mode scan at a resolution setting of 60,000) Figure 1. Q Exactive HF MS and its performance specifications Experimental Sample Preparation Sample Series 1 untargeted lipid identification experiments: Bovine heart total lipid extracts (2.5 mg/ml in chloroform) were purchased from Avanti Polar Lipids. A dilution series of the bovine lipid extract was prepared by diluting the stock solutions sequentially into 1.25 μg/μl, 250 ng/μl, and 50 ng/μl in 50:50 methanol and isopropyl alcohol. Sample Series 2 targeted lipid quantification experiments: Three LIPID MAPS mass spectrometry internal standards (LM-1601, 17:1 LPC; LM-1004, 17:0-14:1 PC; LM-1104, 17:0-14:1 PE) and bovine total lipid extract (2.5 mg/ml in chloroform) were purchased from Avanti Polar Lipids. The stock bovine heart lipid extract was diluted into 500 ng/µl and 250 ng/µl using 50:50 methanol and isopropyl alcohol (Fisher Chemical brand), respectively. Three internal standards were spiked into bovine lipid extract at six different concentrations (0.01 pg/µl, 0.1 pg/µl, 1 pg/µl, 10 pg/µl, 100 pg/µl, and 1000 pg/µl). The final concentration of bovine heart lipid extract for each sample in the dilution series was adjusted to 250 ng/µl. Time % A % B 0 68 32 1.5 68 32 4 55 45 5 48 52 8 42 58 11 34 66 14 30 70 18 25 75 21 3 97 25 3 97 25.01 68 32 33 68 32 Mass Spectrometer Method For untargeted lipid identification experiments (sample series 1), a Q Exactive HF MS and a Thermo Scientific Q Exactive Plus MS with HESI-II probes were employed using the instrument operating conditions shown in Table 2. Each instrument was operated under optimized condition (2.4 s cycle time), providing sufficient scans across the chromatographic peak profile for accurate relative quantification using the high-resolution, accuratemass (HRAM) precursor ion while simultaneously acquiring data dependant-ms spectra for lipid identification. For targeted lipid quantification experiments, the Q Exactive HF MS system with HESI-II probe was operated using four scan events (one full MS scan followed by three targeted MS/MS scans) with the instrument operating conditions shown in Table 2. An inclusion list containing precursor ion masses of the spiked lipid standards (17:1 LPC, m/z 508.3398; 17:0-14:1 PE, m/z 676.4912 and 17:0-14:1 PC, m/z 718.5381) was used for the targeted MS/MS scans.

Table 2. Q Exactive HF MS instrument setup 3 Lipid Identification Experiment Targeted Lipid Quantification Experiment HESI Source Q Exactive Plus MS Q Exactive HF MS Q Exactive HF MS Sheath gas = 35 Positive ion Positive ion or Pos/Neg scan-to scan switching Positive ion Aux gas = 3 Spray voltage = 4.2 kv MS resolution R = 70K Top15 dd-ms2 R = 35K MS resolution R = 120K Top20 dd-ms 2 for Pos; Top10 dd-ms 2 for Pos/Neg polarity switching R = 35K MS resolution R = 120K Targeted MS/MS (PRM) R = 35K S-Lens = 50 MS 2 Isolation width 1 Da MS 2 Isolation width 1 Da MS 2 Isolation width 1 Da Stepped NCE Pos. 25, 30 Stepped NCE Pos. 25, 30 NCE Pos. 30 Capillary temp. = 320 C Neg. 20, 24, 28 Neg. 20, 24, 28 Heater temp. = 300 C AGC target 1E+6 MS 1E+5 MS 2 AGC target 1E+6 MS 1E+5 MS 2 AGC target 1E+6 MS 1E+5 MS 2 Data Processing Thermo Scientific LipidSearch software version 4.0 4 was used for lipid identification. Key processing parameters are shown in Table 3. Table 3. LipidSearch software processing parameters for product ion search. Product Ion Search Precursor tolerance 5 ppm Product tolerance 5 ppm Product ion threshold 5% m-score threshold 5% Quan m/z tolerence ±5 ppm Quan RT range ±1.0 min Main isomer filter On ID quality A,B,C,D Lipid classes LPA,PA,LPC,PC,LPE,PE,LPG,PG,LPI,PI,LPS, PS,SM,MG,DG,TG,FA,CL,So,Cer,GMSGM1, GM2,CerG1,CerG2,CERG3,ChE,Co Adduct ions Positive: +H, +NH 4 ; Negative: -H, +HCOO, -2H Results Lipid Identification Coverage and Throughput In order to benchmark the increased lipid identification coverage on the new Q Exactive HF MS system, a dilution series of bovine heart total lipid extract (1.25 μg/μl, 250 ng/μl, and 50 ng/μl, 2 μl injection) was analyzed by a data-dependent LC MS/MS method in positive mode on the Q Exactive Plus MS system (top 15 MS 2 ) and the new Q Exactive HF MS system (top 20 MS 2 ). The cycle time on both systems was 2.4 seconds. The Q Exactive HF MS system delivers 120K (vs. 70K on the Q Exactive Plus system) resolution in full scan and 30K resolution in MS/MS with very fast data acquisition speed, giving significantly more lipid identifications with high confidence. Under the same LC gradient conditions, the Q Exactive HF MS system identified 20% to 27% more individual lipid species than the Q Exactive Plus MS system, with more significant increase in lipid identifications when the amount of total lipid on column is less (Figure 2). Figure 2. Identification of more lipid species at varying concentrations

4 In addition, the faster scan speed on the Q Exactive HF MS also allowed a shorter and steeper gradient that was half the original run time, while maintaining approximately the same number of lipid species identified by the Q Exactive Plus MS system (Figure 3). Q Exactive Plus MS, 30 min Q Exactive HF MS, 15 min Figure 3. Lipid ID comparison between a 15 min LC-MS run (Q Exactive HF MS system) and a 30 min LC-MS run (Q Exactive Plus MS system). The ID numbers are the average of duplicate HPLC-MS/MS runs. Bovine heart total lipid extract (2500 ng on column). The faster scan speed of the Q Exactive HF MS system can be combined with the online scan-to-scan polarity switching to trigger MS/MS for a higher number of lipids in both positive and negative modes during the same LC-MS run. It allows broader coverage of lipids and further increases the number of identified lipid species. Figure 4 shows the extracted positive and negative ion chromatograms of the bovine heart lipid extract analyzed using the scan-to-scan polarity switching method. While some lipid precursor ions can be observed in both polarities, many only ionized efficiently in one of the two modes. Under the same HPLC conditions, the online scan-to-scan polarity switching method identified one hundred more lipid species compared to the positive ion mode only method (Figure 5). Figure 5. Lipid ID comparison between the positive ion mode only method and scan-to-scan polarity switching method. The ID numbers are the average of duplicate 30 min HPLC-MS/MS runs. Bovine heart total lipid extract (2500 ng on column). The increased resolving power of Q Exactive HF MS system further enhances the lipid ID coverage of the lipidome by increasing the capability to differentiate lipid species from co-eluting isobaric molecular ions in the biological sample. The effect of MS resolution for identification of lipid species at the same retention time is illustrated for two lysophospholipid species, 18:1 LPE and 16:0p LPC. These two lipids overlap during analysis at 2.2 minutes at m/z 480.3 in the positive ion mode. The mass resolution required to separate these two lipids is illustrated in Figure 6. The 60K setting is the minimum resolution required for unequivocal identification of both [M+H] + ions. Thus, ultra-high resolving power ( 60K) is crucial to differentiate overlapping lipid species and achieve accurate identification and quantification. Figure 6. Increased resolution improves identification/quantitation. Identification of minor lipid species is challenging without sufficient mass resolution, leading to fewer identifications. To baseline-separate these two lipid species, a minimum of 60,000 resolving power is required, easily achievable using highresolution Orbitrap technology. Figure 4. Extracted base peak chromatograms of positive and negative ions from the polarity switching experiment. Bovine heart total lipid extract (2500 ng on column).

The advanced quadrupole technology of the Q Exactive HF MS system enables narrow precursor ion isolation width with minimum transmission losses (Figure 7). This is particularly important for lipidomics analysis in which accurate lipid ID can only be obtained via the interpretation of MS/MS. Figure 8 shows two versions of the MS/MS spectra from two co-eluting isomers (LPC(16:0p) and LPE(18:1), whose precursor ions have been shown in Figure 6) collected with 4 amu isolation width (top) and 1 amu isolation width (bottom), respectively. The MS/MS from 4 amu isolation width is dominated with background interference ions from chemical noises, which could make the spectral interpretation very challenging and sometimes even virtually impossible. The MS/MS from 1 amu isolation width is much cleaner and shows much higher selectivity, which enables accurate identification. 5 Figure 7. Narrow isolation width with minimum loss of signal. Duplicate 30 min LC-MS/MS runs. Bovine heart total lipid extract (1000 ng on column).

6 Quantitative data were extracted from both HRAM MS scan data and the PRM scan data. Full-scan HRAM MS data can be used to quantify any detected precursor ions of interest, which enables high-throughput large scale targeted quantification. However, it remains challenging to quantify co-eluting isomers using an HRAM MS approach because it may not be possible to differentiate isomeric lipid species at the precursor ion level. In contrast to the HRAM MS approach, the PRM approach collects all fragment ions of each lipid species and uses one or multiple significant fragment ions for quantification (Figure 9). The MS/MS level selectivity of PRM is capable of separating isomeric lipid species containing different combinations of fatty acid. In general, the LC-PRM method provides lower LOD and LOQ by removing interference from other co-eluting lipids. There are several additional benefits of using the PRM approach for targeted quantification: The identity of the targeted lipid is simultaneously confirmed with high confidence by using the MS/MS spectrum. Figure 8. Higher quality MS/MS with enhanced specificity with 1 amu isolation width, 30 min LC-MS/MS run. Bovine heart total lipid extract (1000 ng on column). Increased Selectivity and Sensitivity for Targeted Lipid Quantification It is important to monitor changes in the lipidome over time in response to perturbation, because such knowledge increases our understanding of how lipids function in a biological system. Lipidomic studies may then be employed for elucidating the mechanism of lipid-based diseases, performing biomarker screening, and quantitative lipid monitoring in pharmacology studies. The Q Exactive HF system allows simultaneous lipid identification and global lipid profiling using LipidSearch software.4 The Q Exactive HF MS system also offers several HRAM approaches, including full MS, SIM, and PRM for targeted lipid quantification. In order to evaluate the performance of the Q Exactive HF MS system for the targeted lipid quantification, a dilution series of three lipid standards were spiked into 500 ng bovine heart total lipid extract at six different concentration ranges (0.01 pg/µl, 0.1 pg/µl, 1 pg/µl, 10 pg/µl, 100 pg/µl, and 1000 pg/µl) and analyzed using the targeted lipid quantification method described in the experimental section. Each spiked lipid sample (2 µl injection) was run in triplicate. Higher selectivity is achieved by using specific fragment ions, which can significantly decrease the isomer/isobar contaminants observed at the MS level. Higher sensitivity is achieved by enriching in the C-Trap only the fragment ions from the targeted lipid precursor. Figure 10 shows the comparison of the full MS data and the PRM data for 17:1 Lyso PC at 20 fg on column. By using only the MS/MS fragment (104.1072 m/z) specific to 17:1 LPC, the PRM result eliminates the two false positive peaks at r.t. 1.02 min and 1.48 min found in the full MS result. In addition, it also eliminates the isomeric contamination peak at r.t. 2.27min, also found in the full MS result. Not only does the targeted PRM approach give higher specificity, it also gives high sensitivity and linear dynamic range. For example, five orders of linear dynamic range (R2 = 0.9961) were observed for 17:0 14:1 PE (Figure 11), demonstrating the excellent analytical precision of the PRM method on the Q Exactive HF MS. For all three lipid standards, a coefficient of variance (CV%) less than 7% was achieved over five orders of magnitude in concentration (Table 4). Figure 9. Targeted quantification using parallel reaction monitoring (PRM) on the Q Exactive HF MS

7 Full MS XIC of 17:1 LPC m/z 508.3398 PRM XIC of 17:1 LPC m/z 508.3398 g 104.1072 Figure 10. Comparison of the full MS data versus the PRM data for 17:1 Lyso PC at 20 fg on column. PRM was able to precisely detect and quantitate the 17:1 Lyso PC at the lowest concentration level of the dilution series. 17:0 14:1 PC spiked into 500 ng Bovine Heart Lipid Extracts (0.02 pg 2000 pg on column) Figure 11. Calibration curve for 17:0 14:1 PE generated using the LC-PRM method. Five orders of linear dynamic range were observed. Table 4. Coefficients of variation (%CV) for the three lipid standards spiked into a bovine heart total lipid extracts over five orders of magnitude in concentration. Spiked Internal Lipid Standard Precursor Ion (m/z) CV% (n=3) 0.01 pg/μl 0.1 pg/μl 1 pg/μl 10 pg/μl 100 pg/μl 1000 pg/μl 17:0-14:1 PE (LM-1104) 676.4912 6.9 6.5 1.8 0.8 1.9 1.1 17:0-14:1 PC (LM-1004) 718.5381 3.2 1.7 0.5 3.3 0 7 17:1 LPC (LM-1601) 508.3398 5.9 3.9 2.8 0.6 0.8 0.6

Conclusions The Q Exactive HF MS is well suited for the analysis of complex lipid extracts. The faster scan speed and higher resolution enabled increased lipid identification coverage and throughput. Up to 27% more lipid species were identified on the Q Exactive HF MS compared to the Q Exactive Plus MS run under similar conditions. Approximately the same number of lipid species were identified on the Q Exactive HF MS in half the analysis time compared to the Q Exactive Plus MS. Scan-to-scan polarity switching can be utilized to further increase the lipid coverage on the Q Exactive HF MS. Over 700 lipids were confidently identified with supporting MS/MS from a 30 minute LC run of bovine heart total lipid extract (2500 ng on column). The higher resolving power of the Q Exactive HF MS provided more confident identification and better relative quantification of a lipidome. Even with LC separation, resolving power at a minimum of 60K is required to resolve lipid isomers. Advanced quadrupole technology enables use of narrow isolation windows for MS/MS acquisition without losing signal. This is particular important for lipidomics analysis in which accurate lipid ID can only be obtained via the interpretation of MS/MS. Narrower precursor ion isolation window provides cleaner MS/MS spectra and shows much higher selectivity, which enables accurate identification of individual lipid species. For targeted lipid quantification, the HRAM PRM approach provided increased selectivity and sensitivity by using MS 2 fragment ion(s) specific to each associated precursor ion, while simultaneously confirming the lipid identity using the full MS/MS spectrum. Compared to the full MS result, the PRM result showed fewer false positives and higher precision. Down to 20 fg LOD and up to five orders of linear dynamic range were observed for the spiked lipid internal standards. Excellent analytical precision was observed using the PRM method. References 1 Watson, A.D. Lipidomics: a global approach to lipid analysis in biological systems. J. Lipid Res. 2006, 47, 2101. 2 Fahy, E. et al. LIPID MAPS comprehensive classification system for lipids. J. Lipid Res. 2009, 50, S9-S14. doi: 10.1194/jlr.R800095-JLR200. 3 Bird, S. et al., Lipidomics profiling by high-resolution LC-MS and high-energy collisional dissociation fragmentation: focus on characterization of mitochondrial cardiolipins and monolysocardiolipins. Anal. Chem. 2011, 83, 940 949. dx.doi.org/10.1021/ ac102598u. 4 Peake, D. et al. Higher resolution LC-MS and MS-MS analysis of lipid extracts using benchtop Orbitrap-based mass spectrometers and LipidSearch software. ASMS poster. 2014, WP287. Application Note 607 www.thermofisher.com 2016 Thermo Fisher Scientific Inc. All rights reserved. Ascentis and Sigma-Aldrich are registered trademarks of Sigma-Aldrich Co. Avanti is a registered trademark of Avanti Polar Lipids, Inc. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa +43 1 333 50 34 0 Australia +61 3 9757 4300 Austria +43 810 282 206 Belgium +32 53 73 42 41 Canada +1 800 530 8447 China 800 810 5118 (free call domestic) 400 650 5118 AN64215-EN 0916S Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland +358 9 3291 0200 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9494 Italy +39 02 950 591 Japan +81 45 453 9100 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Norway +46 8 556 468 00 Russia/CIS +43 1 333 50 34 0 Singapore +65 6289 1190 Spain +34 914 845 965 Sweden +46 8 556 468 00 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752