Managing Metallic Artifacts in MRI

Similar documents
Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

Call Medtronic at 1 (800) to verify the patient s current implanted system

MRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

Advisa MRI and Ensura MRI SureScan pacing systems

ENGINEERED TO ENABLE THE FUTURE OF CONNECTED HEALTH

Model 5392 EPG Temporary Pacer

11 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads

12 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads

PACING AT THE BUNDLE OF HIS

Pediatric pacemakers & ICDs:

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

Product Performance Report. Implantable devices. Pacing leads. Pacemakers. Defibrillators SNIA GROUP

MRI SureScan pacemakers & ICDs what you need to know

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

Revo MRI Pacing System

CONSULTA CRT-P Model C4TR01

MRI imaging for patients with cardiac implantable electronic devices (CIEDs)

Advanced ICD Concepts

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

MRI conditional devices. A luxury or a real clinical need? Sophie Mavrogeni, MD, FESC Onassis Cardiac Surgery Center, Athens, Greece

FREQUENTLY ASKED QUESTIONS MONITORING

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

Cardiovascular magnetic resonance with an MR compatible pacemaker

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

Review of Pacemakers and ICD Therapy: Overview and Patient Management

Orthopedic Hardware Imaging Part II: MRI v. Metal

HOW TO PERFORM HIS-BUNDLE PACING. Training Presentation

IMAGEREADY MR CONDITIONAL PACING SYSTEM

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

VNS Therapy System Physician s Manual

MRI for Patients with MRI-Conditional Pacing System: Radiographers Role. Lawrance Yip DM, DR, QMH

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms

ICD: Basics, Programming and Trouble-shooting

Accessing Battery Information. Status symbol. Figure 1. Summary Dialog screen. Figure 2. Battery Status screen of a TELIGEN ICD 1

Advisa MRI SureScan. PACING SYSTEMs. References 1

MRI GUIDELINES FOR INSPIRE THERAPY

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

Percepta CRT-P MRI SureScan W1TR01

DEFIBRILLATORS. Prof. Yasser Mostafa Kadah

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

ENABLE MRI CLINICAL STUDY SUMMARY

NEIL CISPER TECHNICAL FIELD ENGINEER ICD/CRTD BASICS

National Coverage Determination (NCD) for Cardiac Pacemakers (20.8)

Solara CRT-P MRI SureScan W1TR06

Implantable Cardioverter-Defibril. Defibrillators. Ratko Magjarević

Tachycardia Devices Indications and Basic Trouble Shooting

Devices and EP- Safety in MRI

Supplemental Material

Cardiac Rhythm Therapy // Advanced Features // ProMRI. ProMRI. Checklist and Quick Reference Guide

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

RN-BC, MS, CCRN, FAHA

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

Industry-Tested. Stacks Up To the Competition 2

MR Advance Techniques. Vascular Imaging. Class II

Figure 2. Normal ECG tracing. Table 1.

STANDARD OPERATING PROCEDURE (SOP)

MRI ACCESS. Evera MRI SureScan ICD Systems

High Field MR of the Spine

Presented By: Barbara Furry, RN-BC, MS, CCRN, FAHA Director The Center of Excellence in Education Director of HERO

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Azure XT DR MRI SureScan W2DR01

Preoperative Evaluation: Patients with Cardiac Disease

Active Fixation Models: 7740, 7741 and 7742 Passive Fixation Models: 7731, 7732, 7735 and 7736

GDT1000 SENSING ACUTE STUDY

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE GUIDANCE EXECUTIVE (GE)

MICRA TRANSCATHETER PACING SYSTEM (TPS) REIMBURSEMENT OVERVIEW

1Pulse sequences for non CE MRA

MRI GUIDELINES FOR INSPIRE THERAPY

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System

Temporary pacemaker 삼성서울병원 심장혈관센터심장검사실 박정왜 RN, CCDS

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

Flowchart for ICD patients undergoing Surgery or procedures involving diathermy/magnetic fields

Safety Issue of Static Magnetic Field (1)

Recent Advances in Pacing and Defibrillation Harish Doppalapudi, MD

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

AMPLIA MRI CRT-D SURESCAN DTMB1D4

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide

MRI and CIEDs. Disclosures

12 th International Winter Arrhythmia School Collingwood, Ontario February 7, Dr. Derek Yung. MD, FRCPC

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

Practice Questions.

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART II

MRI Guidelines for the Axonics Sacral Neuromodulation System

ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ

Magnetic Resonance Angiography

Pacing Lead Implant Testing. Document Identifier

BEDSIDE ECG INTERPRETATION

Assessment of Defibrillation Threshold upon Implantable Cardioverter-Defibrillator implant in Relation to patient s prognosis

Transcription:

Managing Metallic Artifacts in MRI William Faulkner, BS, RT (R) (MR) (CT), FSMRT Background Magnetism is a fundamental property of matter. As such, all substances have some type of magnetic property. Magnetic susceptibility refers to an object s or substance s ability to become magnetized. If two substances with different magnetic susceptibilities are close to one another, a small local magnetic field gradient is induced. The greater the difference in magnetic susceptibility between the two, the greater the induced gradient magnetic field will be. This induced gradient magnetic field can result in an image artifact seen as signal loss and even geometric distortion of the anatomy. The presence of metal typically induces a fairly significant local magnetic field gradient. The images in Figure 1 demonstrate the effect on the local magnetic field and the resultant image distortion due to the presence of a paper clip. Image artifacts associated with the presence of metal are a type of artifact due to magnetic susceptibility differences between substances. While they cannot be eliminated entirely they can be minimized by strategically selecting the pulse sequence (when possible) and specific sequence parameters. Pulse Sequence A spin echo sequences uses a 180-degree RF pulse prior to the formation and sampling of the echo. The main purpose of this 180-degree pulse is to correct for the effects of chemical shift and local field inhomogeneities. A gradient echo pulse sequences does not utilize such a refocusing pulse. As such, local field inhomogeneities are much more readily apparent when gradient echo sequences are utilized. Figure 2 shows two axial cervical spine images acquired on a patient with surgical wire in the posterior aspect of the cervical vertebrae. The signal loss and distortion is much more significant on the image acquired with the gradient echo sequence. The larger or more ferromagnetic the metallic object, the larger and more significant the artifactual loss of signal and distortion will be. There are several technical factors which can also affect the size of the susceptibility artifact. The parameters and recommended adjustments are shown in the table below. Parameter/Sequence Imaging Matrix TE (Gradient Echo) Spin Echo Sequence SSFP Fat Saturation Adjustment/Alternate Sequence Fast (Turbo) Spin Echo Fast Gradient Echo (FGE) STIR or Dixon-Based Technique Cardiac studies with MRI rely on the use of very rapid gradient echo sequences. Historically, the most commonly used sequence are variants of SSFP (Steady State Free Precession). When performing a cardiac MRI study on a patient with a SureScan system, the leads and certainly the device itself can contribute to susceptibility artifacts. The SSFP-based sequences are more prone to susceptibility-induced phase errors artifacts due to the underlying principles of the pulse sequence. Fast gradient echo FGE sequences are less susceptible to these errors. See examples on the following page that were acquired on a patient with an Evera MRI ICD system courtesy of Torsten Sommer, MD, PhD. 1

As is readily apparent, the use of an FGE sequence results in reduced susceptibility artifacts from the leads and the ICD device. reduced acquisition matrix, slightly larger FOV and a longer TE. The result is a significantly larger area of signal void due to the presence of the metallic clip. In a clinical study that was conducted to confirm the safety and efficacy of the Evera MRI ICD system, image quality of cardiac scans was assessed. Following implantation (9-12 weeks) 156 patients underwent a cardiac MRI exam. The study concluded that FGE produced better image quality and smaller artifacts for cardiac MRI than SSFP. For studies of the left ventricle, diagnostic image quality was obtainable in 74% of the patients. For studies of the right ventricle, 84% of the exams were of diagnostic quality. (Analysis by Evera MRI clinical study scan committee physicians). Figure 3: Image Courtesy of University of Bonn, Germany, T. Sommer When the echo is sampled in the presence of the readout gradient, a range of frequencies is collected. This range of frequencies sampled is what is referred to as the receiver bandwidth. The receiver bandwidth can be expressed several ways. One way is to simply state the range of frequencies in units of kilohertz (khz). One (1) khz is a thousand (1,000) hertz. For example, if the range of frequencies sampled during the formation of an echo was from 0 (center) to +8,000 Hz and from 0 to -8,000 Hz, this could be expressed as either 16 KHz or +/- 8 KHz. Another way to express the receiver bandwidth is in units of Hz per pixel. Given that the readout gradient is also known as the frequency encoding gradient, the pixels are those along the frequency matrix of the FOV. For example, selecting a frequency matrix of 256 pixels and a receiver bandwidth of 32 khz would result in a receiver bandwidth of 125 Hz per pixel (Figure 6). Figure 4: Image Courtesy of University of Bonn, Germany, T. Sommer Voxel Volume and TE Voxel volume is determined by the Field-of-View (FOV), acquisition matrix, and slice thickness. Figure 5 shows two images acquired on the same patient. The patient has an MR-Conditional intracranial aneurysm clip implanted in the area of the left middle cerebral artery. The image on the left is from a 3D Time-of-Flight (TOF) MRA sequence. For optimum visualization of flow in smaller vessels, 3D TOF sequences use small voxels and a short TE. The image on the right is a 2D gradient echo sequence acquired with a much thicker slice, 2 As previously mentioned, the presence of metal produces a non-uniform or gradient field around the metallic object or device. For a metallic object of a given size and susceptibility, the frequencies of the hydrogen protons will be altered a certain amount. Reducing the Hz/pixel will increase the number of pixels affected by the variance in frequencies and thus increase the size of the susceptibility artifact.

Reducing/Minimizing Susceptibility Artifact Due to Presence of Metal Pulse Sequence Selection As a general rule, images acquired with Fast or Turbo Spin Echo sequences (FSE/TSE) will result in images with fewer susceptibility artifacts than those acquired using gradient echo sequences. However, it is not always possible to replace gradient echo sequences with FSE sequences. Strategic selection of sequence parameters can be very effective. Reducing slice thickness reduces voxel volume and therefore reduces the size of susceptibility artifacts associated with metal. However, signal-to-noise ratio (SNR) is directly proportional to the slice thickness. Reducing the slice thickness by a factor of 2 will reduce SNR by a factor of 2 as well. The use of 3D techniques allows for very thin slices but with much higher SNR than thin 2D slices. Increasing the receiver bandwidth will reduce the size of susceptibility artifacts associated with metal. An example is shown in Figure 7. The patient has a significant amount of metallic dental work. Significant artifact and distortion is seen on the sagittal image (6a). The axial image (6b) was acquired using a receiver bandwidth of +/- 16 khz and also shows significant artifact. The image 6c was acquired using a receiver bandwidth of +/- 64 khz. All other parameters were identical. Although the SNR is reduced, the artifact from the metal dental work is significantly reduced, resulting in a more diagnostic image. When possible, utilize inversion recovery sequences (STIR) for fat suppression. If fat suppression is desired after the administration of a gadolinium-based contrast agent, STIR sequences should not be utilized. Recent implementations of fat suppression based on the Dixon Technique may be considered. These techniques tend to be less sensitive to inhomogeneities as compared to standard RF (or spectral) fat saturation techniques (Figure 9). Specialized Pulse Sequences Recently, several MR vendors have introduced specialized pulse sequences designed to be used when significant metal is present. An example of one type of these metal artifact reduction sequences is shown in Figure 10. The image on the left was acquired using a standard FSE sequence. The image on the right utilizes the specialized pulse sequence designed to significantly reduce metallic artifacts. Sequences Utilizing RF Fat Saturation Fat saturation sequences which suppress the signal from fat based on its spectral frequency rely on high homogeneity of the local magnetic field. The presence of metal significantly distorts the local magnetic field and will result in failed fat suppression (Figure 8). 3

What image artifact do you expect with Medtronic SureScan MR-Conditional pacemakers and ICDs? Medtronic SureScan MR-Conditional pacemakers A clinical study demonstrated that the presence of a SureScan pacemaker system did not reduce the likelihood of obtaining a cardiac MRI exam of good diagnostic quality. The study found that 98% of Left Ventricular and 95% of Right Ventricular acquisitions were of diagnostic quality. 1 Summary Image artifacts associated with the presence of metal are a type of artifact caused by magnetic susceptibility differences between substances. While they cannot be eliminated entirely they can be minimized by strategically selecting the pulse sequence (when possible) and specific sequence parameters. Parameter/Sequence Imaging Matrix TE (Gradient Echo) Spin Echo Sequence SSFP Fat Saturation Adjustment/Alternate Sequence Fast (Turbo) Spin Echo Fast Gradient Echo (FGE) STIR or Dixon-Based Technique Medtronic SureScan MR-Conditional ICDs Magnetic susceptibility artifact will be significantly greater in SureScan ICD patients compared to patients implanted with Advisa MRI SureScan pacemakers. The impact on the diagnostic quality of cardiac MRI scans is strongly related to the distance between the ICD and the region being imaged. According to Torsten Sommer, MD, PhD, Professor of Radiology, Chief of Cardiovascular Imaging, University of Bonn, the image artifact will typically overlap most of the LV for patients with a SureScan ICD implanted on the left side, but it is generally possible to image the RV with acceptable image quality. Sasaki, et al. 2 characterized cardiac MRI image artifact in patients with pacemakers and implantable cardioverterdefibrillators and concluded that: Despite the presence of some artifact in most image sequences, images were completely (18/55 scans, 32.7%) or partially (31/55 scans, 56.4%) interpretable in most patients with left-side ICD/ BiV-ICD systems. And It was possible to evaluate cardiac function using cine CMR in 86% of patients with left sided ICD. The most significant predictors of the capability to assess cardiac function were BMI and LVEDD. Both associations are probably mediated by the distance between the PM/ICD generator and the heart. Why is there greater artifact with a SureScan ICD than with a SureScan pacemaker? The difference is due to the larger battery relative to Advisa MRI SureScan pacemaker and ferromagnetic material in the high-voltage transformer of the SureScan ICD. 4

References 1 Schwitter J, Kanal E, Schmitt M, et al. Impact of the Advisa MRI pacing system on the diagnostic quality of cardiac MR images and contraction patterns of cardiac muscle during scans: Advisa MRI randomized clinical multicenter study results. Heart Rhythm. June 2013;10(6):864-872. 2 Sasaki T, Hansford R, Zviman MM, et al. Quantitative assessment of artifacts on cardiac magnetic resonance imaging of patients with pacemakers and implantable cardioverter-defibrillators. Circ Cardiovasc Imaging. November 2011;4(6):662-670. Brief Statement The SureScan systems are MR Conditional, and as such are designed to allow patients to undergo MRI under the specified conditions for use. When programmed to On, the MRI SureScan feature allows the patient to be safely scanned while the device continues to provide appropriate pacing. Indications The SureScan systems are indicated for use as a system. A complete SureScan system, which is a SureScan device with appropriate SureScan lead(s), is required for use in the MR environment. To verify that components are part of a SureScan system, visit http:// www.mrisurescan.com/. Any other combination may result in a hazard to the patient during an MRI scan. The SureScan pacing systems are indicated for Patients who may benefit from increased pacing rates concurrent with increases in activity. Accepted patient conditions warranting chronic cardiac pacing include symptomatic paroxysmal or permanent second- or third-degree AV block, bilateral bundle branch block, or paroxysmal or transient sinus node dysfunctions with or without associated AV conduction disorders; or bradycardia-tachycardia syndrome to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias. Dual chamber SureScan pacing systems are also indicated for dual chamber and atrial tracking modes in patients who may benefit from maintenance of AV synchrony or for treatment of conduction disorders that require restoration of both rate and AV synchrony, which include various degrees of AV block to maintain the atrial contribution to cardiac output, VVI intolerance (for example, pacemaker syndrome) in the presence of persistent sinus rhythm, vasovagal syndromes or hypersensitive carotid sinus syndromes, or antitachycardia pacing (ATP) indicated for termination of atrial tachyarrhythmias in bradycardia patients with one or more of the above pacing indications. SureScan defibrillation systems are indicated to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias. In addition, the dual chamber devices are indicated for use in the above patients with atrial tachyarrhythmias, or those patients who are at significant risk of developing atrial tachyarrhythmias. Contraindications The SureScan pacing systems are contraindicated for implantation with unipolar pacing leads (Revo MRI only), concomitant implantation with another bradycardia device or an implantable cardioverter defibrillator. Dual chamber sequential pacing is contraindicated in patients with chronic or persistent supraventricular tachycardias, including atrial fibrillation or flutter. SureScan defibrillation systems are contraindicated for patients experiencing tachyarrhythmias with transient or reversible causes including, but not limited to, the following: acute myocardial infarction, drug intoxication, drowning, electric shock, electrolyte imbalance, hypoxia, or sepsis. The device is contraindicated for patients who have a unipolar pacemaker implanted. The device is contraindicated for patients with incessant VT or VF. For dual chamber devices, the device is contraindicated for patients whose primary disorder is chronic atrial tachyarrhythmia with no concomitant VT or VF. For single chamber devices, the device is contraindicated for patients whose primary disorder is atrial tachyarrhythmia. Warnings and Precautions Changes in patient s disease and/or medications may alter the efficacy of the device s programmed parameters. Patients should avoid sources of magnetic and electromagnetic radiation to avoid possible underdetection, inappropriate sensing and/ or therapy delivery, tissue damage, induction of an arrhythmia, device electrical reset, or device damage. www.medtronic.com Medtronic, Inc. 710 Medtronic Parkway Minneapolis, MN 55432-5604 USA Tel: (763) 514-4000 Fax: (763) 514-4879 Medtronic USA, Inc. Toll-free: 1 (800) 328-2518 (24-hour technical support for physicians and medical professionals) Do not place transthoracic defibrillation paddles directly over the device. Patients and their implanted systems must be screened to meet the following requirements for MRI: All Systems: no lead extenders, lead adaptors or abandoned leads present; no broken leads or leads with intermittent electrical contact as confirmed by lead impedance history; and the system must be implanted in the left or right pectoral region. Patient must have pacing capture thresholds of 2.0 V at a pulse width of 0.4 ms. No diaphragmatic stimulation at a pacing output of 5.0 V and at a pulse width of 1.0 ms in patients whose device will be programmed to an asynchronous pacing mode when MRI SureScan is on. IPG specific: a SureScan pacing system that has been implanted for a minimum of 6 weeks; pace polarity parameters set to Bipolar for programming MRI SureScan to On (Advisa MRI only); or a SureScan pacing system with a lead impedance value of 200 Ω and 1,500 Ω. Patients may be scanned using a horizontal field, cylindrical bore, clinical 1.5T MRI system with operating frequency of 64 MHz, maximum spatial gradient 20 T/m, and maximum gradient slew rate performance per axis 200 T/m/s. Scanner must be operated in Normal Operating Mode (whole body averaged specific absorption rate (SAR) 2.0 W/ kg, head SAR 3.2 W/kg). For SureScan pacing systems, proper patient monitoring must be provided during the MRI scan. For SureScan defibrillation systems, continuous patient monitoring is required while MRI SureScan is programmed to On. Do not scan a patient without first programming MRI SureScan to On and do not leave the device in MRI SureScan mode after the scan is complete. While MRI SureScan is programmed to On, arrhythmia detection and therapies are suspended, leaving the patient at risk of death from untreated spontaneous tachyarrhythmia. In addition, if the device is programmed to an asynchronous pacing mode, arrhythmia risk may be increased. Potential Complications Potential complications include, but are not limited to, rejection phenomena, erosion through the skin, muscle or nerve stimulation, oversensing, failure to detect and/or terminate arrhythmia episodes, acceleration of tachycardia, and surgical complications such as hematoma, infection, inflammation, and thrombosis. Potential lead complications include, but are not limited to, valve damage, fibrillation, thrombosis, thrombotic and air embolism, cardiac perforation, heart wall rupture, cardiac tamponade, pericardial rub, infection, myocardial irritability, and pneumothorax. Other potential complications related to the lead may include lead dislodgement, lead conductor fracture, insulation failure, threshold elevation, or exit block. Potential MRI complications include, but are not limited to, lead electrode heating and tissue damage resulting in loss of sensing or capture or both, or MR-induced stimulation on leads resulting in continuous capture, VT/VF, and/or hemodynamic collapse. See the MRI SureScan Technical Manual before performing an MRI Scan and see the device manuals for detailed information regarding the implant procedure, indications, contraindications, warnings, precautions, and potential complications/adverse events. For further information, call Medtronic at 1 (800) 328-2518 and/or consult Medtronic s website at www.medtronic.com or www.mrisurescan.com. Caution: Federal law (USA) restricts these devices to sale by or on the order of a physician. 5 UC201406066 EN Medtronic, Inc. 2015. Minneapolis, MN. All Rights Reserved. Printed in USA. 07/2015