CLINICAL SCIENCES. (FDP) was designed to emphasize the response characteristics of the parasol

Similar documents
STANDARD AUTOMATED PERIMETRY IS A GENERALLY

Test-retest variability in visual field testing using frequency doubling technology

Access to the published version may require journal subscription. Published with permission from: Elsevier

F requency doubling technology (FDT) perimetry was

21st Century Visual Field Testing

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

Misleading Statistical Calculations in Faradvanced Glaucomatous Visual Field Loss

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

CLINICAL SCIENCES. Glaucoma Monitoring in a Clinical Setting

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Receiver operating characteristic (ROC) curves are a wellaccepted

The improvement in perimetric results occurring over

CORRELATING OF THE VISUAL FIELD INDEX WITH MEAN DEVIATION AND PATTERN STANDARD DEVIATION IN GLAUCOMA PATIENTS

Scanning laser polarimetry (SLP) provides real-time, objective

PATTERNS OF GLAUCOMATOUS VISUAL FIELD LOSS IN SITA FIELDS AUTOMATICALLY IDENTIFIED USING INDEPENDENT COMPONENT ANALYSIS

Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation

Diagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study METHODS

Financial Disclosure. Visual Field Interpretation RELIABILITY VISUAL FIELD INTERPRETATION IN GLAUCOMA METHODS OF DATA PRESENTATION

Citation for published version (APA): Wesselink, C. (2017). Glaucoma care optimised in an ageing population [Groningen]: Rijksuniversiteit Groningen

T he retinal ganglion cells of different sizes have distinct

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography

Introduction. Paulo de Tarso Ponte Pierre-Filho, 1 Rui Barroso Schimiti, 1 Jose Paulo Cabral de Vasconcellos 1 and Vital Paulino Costa 1,2

Learning Effect and Test-Retest Variability in Healthy Subjects and Patients with Primary Open Angle Glaucoma Using Rarebit Perimetry

Science & Technologies

Research Article The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma

CLINICAL SCIENCES. Differences in Visual Function and Optic Nerve Structure Between Healthy Eyes of Blacks and Whites

Relationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma

Rarebit perimetry and frequency doubling technology in patients with ocular hypertension

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

Optical coherence tomography (OCT) is a noninvasive,

T he extent of damage to the optic nerve caused by nonarteritic

NIH Public Access Author Manuscript Arch Ophthalmol. Author manuscript; available in PMC 2013 October 01.

3/16/2018. Perimetry

Investigative Ophthalmology & Vision Sciences MSc Course. Glaucoma Module. Visual Field Reliability Indices. David Henson 2014.

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

CLINICAL SCIENCES. Steven L. Mansberger, MD; Pamela A. Sample, PhD; Linda Zangwill, PhD; Robert N. Weinreb, MD

CLINICAL SCIENCES. Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD

Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients

Correlating Structure With Function in End-Stage Glaucoma

S Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science

Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors

Diagnosing open-angle glaucoma may be particularly

A comparison of HRT II and GDx imaging for glaucoma detection in a primary care eye clinic setting

Expanding your field of vision. Visual Field Analyzers from Carl Zeiss

The determination of glaucoma progression is based on a. Refinement of Pointwise Linear Regression Criteria for Determining Glaucoma Progression

Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.

Glaucoma: Diagnostic Modalities

Citation for published version (APA): Stoutenbeek, R. (2010). Population based glaucoma screening Groningen: s.n.

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

Relationship Between Structure

Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial

CLINICAL SCIENCES. Screening for Glaucoma With Frequency-Doubling Technology and Damato Campimetry

Scanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve Fiber Layer Defects

Discrimination between normal and glaucomatous eyes with visual field and scanning laser polarimetry measurements

THE BASIC PATHOLOGIC CHANGE IN GLAUCOMA IS

Visual Fields Shawn L. Cohen, M.D. Part 2 of 4. Definitions / Tables (Part 2 of 2) Static Perimetry (Humphrey, Octopus)

Detection of Progressive Retinal Nerve Fiber Layer Loss in Glaucoma Using Scanning Laser Polarimetry with Variable Corneal Compensation

RETINAL NERVE FIBER LAYER

Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

Comparison of Visual Field Measurement with Heidelberg Edge Perimeter and Humphrey Visual Field Analyzer in Patients with Ocular Hypertension

Characteristics of Frequency-of-Seeing Curves in Normal Subjects, Patients With Suspected Glaucoma, and Patients With Glaucoma

TUMBLING E RESOLUTION PERIMETRY IN GLAUCOMA

C linical visual field tests are designed to provide. Measurement error of visual field tests in glaucoma LABORATORY SCIENCE

CLINICAL SCIENCES. optic neuropathy characterized

The Role of the RNFL in the Diagnosis of Glaucoma

Baseline Visual Field Characteristics in the Ocular Hypertension Treatment Study

Perimetric testing is used clinically to detect visual field

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

A New Model for Assessment of Change in Visual Function in Diabetes

Diagnostic Accuracy of Scanning Laser Polarimetry with Enhanced versus Variable Corneal Compensation

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

City, University of London Institutional Repository

Incorporating Risk Factors to Improve the Assessment of Rates of Glaucomatous Progression

The overall rate of decrease in visual field sensitivity in

Glaucoma Diagnosis. Definition of Glaucoma. Diagnosing Glaucoma. Vision Institute Annual Fall Conference

New Concepts in Glaucoma Ben Gaddie, OD Moderator Murray Fingeret, OD Louis Pasquale, MD

Optic disc damage has been shown to precede visual field

Clinical Study Visual Field Loss Morphology in High- and Normal-Tension Glaucoma

Relationship between GDx VCC and Stratus OCT in juvenile glaucoma

Optical Coherence Tomograpic Features in Idiopathic Retinitis, Vasculitis, Aneurysms and Neuroretinitis (IRVAN)

Correlation of Blue Chromatic Macular Sensitivity with Optic Disc Change in Early Glaucoma Patients

Early detection and control of disease progression or

VISUAL FIELD TESTING OCCUpies

Factors Associated With Visual Field Progression in Cirrus Optical Coherence Tomography-guided Progression Analysis: A Topographic Approach

The frequency-doubling illusion occurs when a low-spatialfrequency

7/25/2018. You talk about glaucoma in cup-to-disc ratios ASSESSING THE OPTIC DISC: IS PHOTOGRAPHY STILL NECESSARY IN THE OCT ERA?

THE DEMOGRAPHICS OF THE

Generally, myopia is a condition of the eye that makes it

Patterns of Subsequent Progression of Localized Retinal Nerve Fiber Layer Defects on Red-free Fundus Photographs in Normal-tension Glaucoma

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

The Evolution of Fundus Perimetry

CHAPTER 10 NON-CONVENTIONAL PERIMETRY

Retinal Nerve Fiber Layer Measurement Variability with Spectral Domain Optical Coherence Tomography

GLAUCOMA SUMMARY BENCHMARKS FOR PREFERRED PRACTICE PATTERN GUIDELINES

The evaluation of retinal nerve fiber layer in pigment dispersion syndrome and pigmentary glaucoma using scanning laser polarimetry

Correspondence should be addressed to Verena Prokosch;

Il contributo dell'angio-oct: valutazione integrata della componente nervosa e vascolare della malattia glaucomatosa

Transcription:

CLINICAL SCIENCES Detecting Visual Function Abnormalities Using the Swedish Interactive Threshold Algorithm and Matrix Perimetry in Eyes With Glaucomatous Appearance of the Optic Disc Lisandro M. Sakata, MD; Julio DeLeon-Ortega, MD, PhD; Stella N. Arthur, MD, MSPH; Blythe E. Monheit, MD; Christopher A. Girkin, MD, MSPH Objective: To compare the ability of 24-2 frequencydoubling perimetry (FDP-Matrix) with standard automated perimetry with the Swedish interactive threshold algorithm (SAP-SITA) in detection of visual function abnormalities in patients with glaucomatous-appearing optic discs (GAOD). Methods: This observational case-control study included 80 patients with GAOD and 54 control subjects diagnosed by masked assessment of optic disc stereoscopic photographs. Abnormal visual function at SAP- SITA and FDP-Matrix testing required consistent abnormalities in 2 visual field examinations, determined using the glaucoma hemifield test outside 99% normal limits, pattern standard deviation outside 95% normal limits, or 3 contiguous points in the pattern deviation probability plot outside 95% normal limits (at least 1 P 1%) within the same hemifield. Results: The FDP-Matrix and SAP-SITA detected abnormal visual function in 51% and 44%, respectively, of GAOD eyes (P=.26), and both perimetry techniques identified 11% of healthy eyes as abnormal. Agreement between FDP-Matrix and SAP-SITA was moderate ( =0.49), as only 35% of GAOD eyes and 2% of healthy eyes had both visual field test results flagged as abnormal. Conclusions: The FDP-Matrix detected abnormal visual function in more eyes with GAOD than did SAP- SITA, although this difference was not significant. Each visual field test tended to identify different subsets of eyes with GAOD as abnormal. Combination of these perimetry techniques may improve the detection of visual function abnormalities in patients with glaucoma. Arch Ophthalmol. 2007;125:340-345 Author Affiliations: Department of Ophthalmology, School of Medicine, University of Alabama at Birmingham. FREQUENCY-DOUBLING PERIMetry (FDP) was designed to emphasize the response characteristics of the parasol ganglion cells. 1 The firstgeneration instrument used 10 targets to test contrast sensitivity. 1-3 Recently, a second-generation FDP (the FDP-Matrix) has become available. The FDP-Matrix uses smaller stimuli and more test locations than those of the original FDP device, permitting a stimulus pattern equivalent to the Humphrey field analyzer 24-2 test. 4 This new perimeter can provide greater details of the spatial distribution of visual field (VF) defects. 4 Several studies have reported that the first-generation FDP had higher levels of discriminatory power for detecting glaucomatous VF loss than did standard automated perimetry (SAP) using the fullthreshold (FT) strategy. 5-7 However, to our knowledge, a comprehensive comparison of the diagnostic performance between SAP using the Swedish interactive threshold algorithm (SITA) and FDP- Matrix in an unbiased population has not been previously studied. The objective of the present study was to compare the ability of FDP-Matrix with that of SAP-SITA, as used in clinical practice, in detection of visual function abnormalities in eyes with glaucomatous-appearing optic discs (GAOD). METHODS This was an observational case-control study. All patients have undergone optic disc imaging and visual function testing as part of ongoing longitudinal glaucoma studies conducted at the Glaucoma Service, University of Alabama at Birmingham, between January 2, 2003, and February 28, 2005. Patients with glaucoma were recruited from the university s glaucoma clinics by medical record review, and control sub- 340

jects were recruited from among university employees and from the general population through advertisement. The protocol included screening, baseline, and regular follow-up visits. Informed consent was obtained from all participants. The institutional review board at the University of Alabama at Birmingham approved all protocols, and all methods adhered to the tenets of the Declaration of Helsinki. All subjects underwent a comprehensive ophthalmic examination including review of medical history, best-corrected visual acuity, slitlamp biomicroscopy, Goldmann applanation tonometry, gonioscopy, dilated fundus examination using a 78- diopter (D) lens, stereoscopic optic disc photography, and automated perimetry. To be included, subjects were required to have an open-angle, best-corrected visual acuity 20/40 or better, spherical refraction within plus or minus 5.0 D and cylinder correction within plus or minus 3.0 D. Patients were excluded if they had a history of intraocular surgery (except for uncomplicated cataract surgery or glaucoma surgery), visually significant cataracts (nuclear sclerotic cataracts with visual acuity worse than 20/40 or posterior subcapsular cataract), problems affecting color vision other than glaucoma, use of medication known to affect visual sensitivity at the time of testing, and other diseases affecting the VF. Some patients with glaucoma were receiving topical intraocular pressure lowering therapy. Similar to previous studies designed to compare VF testing in the detection of glaucoma in an unbiased manner, 5,7 glaucoma diagnosis was based on the presence of GAOD on stereoscopic photographs taken with a simultaneous stereoscopic fundus camera (Nidek 3Dx fundus camera; Nidek Corporation Ltd, Gamagori, Japan). Visual field test results were not considered for glaucoma diagnosis. Control subjects were required to have intraocular pressure less than 22 mm Hg, no history of increased intraocular pressure, normal findings at bilateral eye examination, and normal-appearing optic discs at stereophotographic evaluation. When both eyes in the same patient were eligible, 1 eye was randomly selected for inclusion in the study. All stereoscopic photographs were evaluated independently by 3 fellowship-trained glaucoma specialists ( J.D.-O., B.E.M., and C.A.G.). Each grader was masked to the subject s identity and other test results. Stereoscopic photographs with adequate quality were graded dichotomously (GAOD or normal). Criteria for classification were based on observance of typical glaucomatous optic disc characteristics including neuroretinal rim thinning, notching, nerve fiber layer defects, or optic disc hemorrhages. In cases of disagreement (17 eyes), this was resolved by consensus among the 3 graders. The SAP-SITA-standard perimetry 8,9 was conducted with the Humphrey field analyzer (Humphrey model 750; Carl Zeiss Meditec, Dublin, Calif), and FDP perimetry with an FDP-Matrix perimeter (Welch-Allyn, Skaneateles Falls, NY; and Carl Zeiss Meditec). The FDP-Matrix uses 5 square spatial frequencydoubling stimuli with exposure for 500 ms. 4,10 The psychophysical strategy used by FDP-Matrix is called zippy estimation by sequential testing. 4,10,11 In brief, this strategy determines the likely distribution of sensitivities according to the patient s responses to 4 stimuli presentations at each location. 4,11 When all sensitivities are estimated, its algorithm checks for any points that differ by more than 4 db from 4 neighboring points, then determines sensitivity again for these points. 11 The SAP-SITA and FDP-Matrix were conducted using the 24-2 program. The 2 locations nearest the blind spot and the foveal location were excluded from the analysis, leaving a total of 52 test locations for each technique. Each patient underwent both perimetry examinations at the screening and second visits, within 1 to 8 weeks. Patients with eyes with GAOD underwent third SAP and FDP examinations within 12 to 14 months after the second visit. Visual field examinations were performed in random order, with rest periods of at least 15 minutes between tests. Only reliable VF examinations ( 33% of fixation losses, or false-positive or false negative results) were considered for analysis. To compare the performance of these techniques as they are used in clinical practice, SAP-SITA and FDP-Matrix abnormalities were determined by comparing each patient s results with the manufacturer s internal normative databases. Abnormal VF results with both examination techniques were defined by any of the following criteria: glaucoma hemifield test results outside of the 99% normal limits; pattern standard deviation outside of the 95% normal limits; or presence of a cluster of 3 contiguous points or more, within the same hemifield, at the pattern deviation with P 5% or worse (at least 1 point with P 1%), within the same hemifield in 2 VF examinations. To ensure that false-positive results on either field test were not due to learning effect or threshold variability, we required consistent results on 2 VF tests with each perimetry technique. Thus, abnormal visual function status required a repeated abnormality at 2 SAP or 2 FDP examinations, and normal visual function required normal findings at 2 SAP or FDP examinations (consistent results). Patients with eyes with GAOD underwent 3 VF tests. Their visual function status with each technique was determined by the results of the first 2 VF tests with consistent results or by results of the third VF test if the first 2 VF tests with any perimetry technique yielded inconsistent results (1 VF test with normal results and the other with abnormal results). However, recruited control subjects performed only 2 VF tests, and their visual function status could only be determined in cases with consistent results for the first 2 VF tests. Control subjects who had inconsistent results in any perimetry technique were excluded from analysis. This should not have biased the results in favor of either test. For analysis purposes, we used the results of the second SAP and the second FDP examinations for control subjects and patients with eyes with GAOD with consistent results, and the results of the third SAP and third FDP examinations for patients with eyes with GAOD who had inconsistent results on the first set of VF examinations with any perimetry technique. The extension of the VF defect was compared by determining the number of abnormal points (P 5% or worse) on the pattern deviation and total deviation s for each perimetry technique. Overlapping locations (by quadrants) of VF defects were evaluated in eyes with GAOD that had at least 1 reproducible cluster with any technique. Severity of VF loss was determined using the criteria for SAP of Hodapp et al. 12 Parametric and nonparametric tests were used to compare continuous variables, according to data distribution. The 2 test was used to compare categorical data. The McNemar test was used to compare differences in distribution of a categorical variable. The statistic was used to assess agreement between categorical variables. Pearson correlations were used to correlate global indices between techniques, and correlation coefficients were compared using the method proposed by Glass and Stanley. 13 P.05 was considered statistically significant. Statistical analyses were performed using JMP5 and SAS statistical software (both by SAS Institute Inc, Cary, NC). RESULTS Data for 189 eyes in 189 subjects were obtained from the University of Alabama at Birmingham Optic Nerve Imaging Center database. A total of 94 eyes with GAOD and 95 healthy eyes based on grading of stereoscopic pho- 341

Table 1. Demographic Data for the Study Population* Variable Patients With GAOD Control Subjects P Value No. of eyes 80 54 Age, y 57.4 ± 11.9 39.3 ± 12.5.001 Female sex, % 60 67.76 Race/ethnicity, % African American 55 46.83 White 45 54 SAP-SITA MD, db 1.39 ± 3.48 0.41 ± 0.98.007 FDP-Matrix MD, db 2.75 ± 4.58 0.19 ± 2.65.003 SAP-SITA PSD, db 3.16 ± 3.24 1.41 ± 0.30.001 FDP-Matrix PSD, db 3.73 ± 2.09 2.70 ± 0.63.002 Abbreviations: FDP, frequency-doubling perimetry; GAOD, glaucomatous-appearing optic disc; MD, mean deviation; PSD, pattern standard deviation; SAP, standard automated perimetry; SITA, Swedish interactive threshold algorithm. *Data are given as mean ± SD unless otherwise indicated. t Test. 2 Test. Wilcoxon test. BSAP-SITA Duration, s A 550 FDP-Matrix Duration, s 500 450 400 350 300 250 200 20 15 10 5 0 5 SAP-SITA MD 550 500 450 400 350 300 250 200 20 15 10 5 0 5 FDP-Matrix MD Figure 1. Scatterplots show the relationship between testing time and mean deviation (MD) values at standard automated perimetry Swedish interactive threshold algorithm (SAP-SITA) (A) and frequency-doubling perimetry (FDP-Matrix) (B) examinations (r= 0.70, P.001 and r= 0.24; P=.006, respectively). A SAP-SITA 7 (9%) 28 (35%) FDP-Matrix 13 (16%) SAP-SITA 5 (9%) 1 (2%) FDP-Matrix 5 (9%) Figure 2. Venn diagrams show the agreement between standard automated perimetry Swedish interactive threshold algorithm (SAP-SITA) and frequency-doubling perimetry (FDP-Matrix) in detecting visual function abnormalities in 80 eyes with a glaucomatous-appearing optic disc (A) and 54 healthy eyes (B). tographs were initially enrolled. Visual function could be determined in 54 of 95 healthy eyes; 41 healthy eyes with inconsistent results at the first 2 FDP or SAP tests (18 at FDP, 17 at SAP, and 6 at both tests) were excluded. Twenty-four of the 41 healthy eyes with inconsistent results had abnormal results at the first FDP or SAP test (13 at FDP, 9 at SAP, and 2 at both tests) and normal results at the second VF test, suggesting a learning effect. Eighty of 94 eyes with GAOD met our study requirements to determine visual function, and 30 of these required a third VF test to determine visual function because of inconsistent results at the first 2 FDP and SAP tests (14 at FDP, 11 at SAP, and 5 at both tests). Table 1 gives the demographic data for the study population. Although patients with eyes with GAOD were older than control subjects, only age-corrected parameters from the SAP (StatPac software; StatPac Inc, Bloomington, Minn) and age-normative FDP database (Carl Zeiss Meditec Inc) were considered for VF diagnosis. Overall, the test time (mean±sd) for SAP-SITA was shorter than for FDP-Matrix (305±52 seconds vs 315±5 seconds, respectively; P=.02). In control subjects, SAP- SITA test time was shorter than for FDP-Matrix (286±31 seconds vs 314±18 seconds, respectively; P.001), but no difference was observed among patients with eyes with GAOD (311±57 seconds vs 318±14 seconds for SAP and FDP-Matrix, respectively; P=.21). Figure 1 shows that test time for both SAP-SITA and FDP-Matrix increased with VF damage (mean deviation); however, the correlation coefficients were significantly different (P.001). Based on our study criteria, 32 (40%) of 80 eyes with GAOD had normal visual function as assessed with both perimetry techniques. Abnormal visual function was detected in 41 (51%) of 80 eyes with GAOD with FDP- Matrix and in 35 (44%) of 80 eyes with GAOD with SAP- SITA (P=.27). Agreement between the 2 examinations was moderate ( ±SE, 0.49±.08; Figure 2). Figure 3 shows the FDP-Matrix results in eyes with GAOD stratified to the severity of VF loss at SAP-SITA examination. Table 2 gives the sensitivity and specificity of SAP-SITA and FDP- Matrix for each of the 3 criteria for VF abnormality used in this study. The FDP-Matrix showed a borderline higher sensitivity than the SAP-SITA when using the criteria of a cluster of 3 contiguous abnormal points or more in the pattern deviation plot; however, no differences in sensi- B 342

tivity were found between VF techniques at the same level of specificity (89%) when any of the criteria that defined an abnormal VF were used. Correlations of global indices (mean deviation and pattern standard deviation) between SAP-SITA and FDP-Matrix were strong (r=0.75 for mean deviation and r=0.83 for pattern standard deviation, respectively; P.001). The correlations of the numbers of abnormal points in total deviation and pattern deviation probability plots between the 2 techniques were also strong (r=0.80 and r=0.78, respectively; P.001). Table 3 gives the number of abnormal points on pattern deviation and total deviation s between the 2 techniques in eyes with GAOD and control eyes; 53% (42/80) of eyes with GAOD had a greater number of abnormal points on the pattern deviation plot at SAP, 36% (29/80) of eyes had a greater number of abnormal points at FDP, and 11% (9/80) of eyes had an equal number of abnormal points on both tests. In 31 eyes with GAOD, an abnormal quadrant was detected with at least 1 of the perimetry techniques. Of these 31 eyes, 20 (65%) had at least 1 defective quadrant in common at SAP-SITA and FDP-Matrix, 7 (23%) had an overlap of all abnormal quadrants, and 11 (35%) did not have any abnormal quadrant in common. COMMENT This study compared SAP-SITA and FDP-Matrix instruments as used in clinical practice to detect visual function abnormalities. While we found no significant difference in visual dysfunction between FDP-Matrix and SAP-SITA examinations, our results indicate that SAP-SITA and FDP-Matrix tended to detect abnormalities in different subsets of eyes with GAOD. Furthermore, disagreement between the techniques occurred in eyes with early and moderate VF loss at SAP-SITA. These results suggest that functional changes in early glaucoma detected at clinical perimetry may differ significantly between individuals. Sample et al 5 compared the results of 4 different VF tests (the first-generation FDP, SAP-FT, short-wave length automated perimetry, and motion automated perimetry) in the same cohort of patients and observed individual differences in which perimetric tests detected VF losses earliest. Our findings also support that visual Table 3. Number of Abnormal Points at SAP-SITA and FDP-Matrix Examinations of 80 Eyes With GAOD and 54 Healthy Control Eyes* No. of Eyes 40 30 20 10 0 32 13 4 9 Normal Early Moderate Severe 3 12 Severity of Visual Field Loss With SAP-SITA Normal FDP-Matrix Abnormal FDP-Matrix 0 7 No. of Abnormal Points SAP-SITA FDP-Matrix P Value Eyes with GAOD deviation 9.34 ± 9.04 8.07 ± 7.88 0.18 Total deviation 9.67 ± 12.31 10.75 ± 13.07 0.10 Healthy control eyes deviation 3.18 ± 2.98 2.91 ± 3.60 0.57 Total deviation 1.31 ± 2.27 2.80 ± 5.89 0.07 Figure 3. Results of frequency-doubling perimetry (FDP-Matrix) examination in eyes with a glaucomatous-appearing optic disc classified according to the severity of visual field loss observed at standard automated perimetry Swedish interactive threshold algorithm (SAP-SITA) examination, as assessed with the criteria of Hodapp et al. 12 Abbreviations: FDP, frequency-doubling perimetry; GAOD, glaucomatous-appearing optic disc; SAP, standard automated perimetry; SITA, Swedish interactive threshold algorithm. *Data are given as mean ± SD. Wilcoxon test. Table 2. Sensitivity and Specificity of Perimetry Techniques for Visual Function Abnormality Criteria Criterion SAP-SITA FDP-Matrix P Value* SITA and FDP-Matrix SITA or FDP-Matrix GHT outside normal limits, % Sensitivity 31 42.06 25 49 Specificity 98 91.22 100 89 PSD 5% Sensitivity 40 34.30 27 46 Specificity 96 89.22 98 87 Cluster on PD plot, % Sensitivity 35 47.05 27 55 Specificity 89 89.99 98 80 Any of 3 criteria, % Sensitivity 44 51.26 35 60 Specificity 89 89.99 98 80 Abbreviations: FDP, frequency-doubling perimetry; GHT, glaucoma hemifield test; PD, pattern deviation; PSD, pattern standard deviation; SAP, standard automated perimetry; SITA, Swedish interactive threshold algorithm. *McNemar test. Sensitivity and specificity when abnormalities were found in both tests. Sensitivity and specificity when abnormalities were found in either of the 2 tests. 343

A SAP-SITA Examination B FDP-Matrix Examination First Test Second Test First Test Second Test MD 0.49 db PSD + 2.37 db; P <0.5% MD 0.03 db PSD + 2.13 db MD + 0.08 db PSD + 1.58 db MD 0.34 db PSD + 1.58 db MD + 2.57 db PSD + 2.79 db MD 0.61 db PSD + 3.09 db MD 8.98 db; P <0.5% PSD + 5.22 db; P <0.5% MD 10.98 db; P <0.5% PSD + 5.78 db; P <0.5% Figure 4. deviation s of the first and second standard automated perimetry (SAP) and frequency-doubling perimetry (FDP) tests in 2 eyes with normal-appearing optic discs. A, The SAP Swedish interactive threshold algorithm (SITA) examination shows a consistent defect in the superior quadrant, and the FDP-Matrix examination shows normal findings. B, The FDP-Matrix examination shows a consistent defect, and the SAP-SITA examination shows normal findings, according to our study criteria. GHT indicates glaucoma hemifield test; MD, mean deviation; ONL, outside normal limit; PSD, pattern standard deviation; and WNL, within normal limit. dysfunction in early glaucoma may vary significantly between individuals, and a multimodal functional assessment may be more effective. Previous reports observed that the first-generation FDP was more sensitive in detecting glaucoma than the SAP using the FT strategy. 1,5,6 Boden et al 7 compared the firstgeneration FDP with the SAP-FT and SAP-SITA in 104 eyes with glaucomatous optic neuropathy, and confirmed that the first-generation FDP identified more eyes with glaucomatous optic neuropathy than did the SAP-FT. However, when the first-generation FDP was compared with the SAP-SITA, both perimetry techniques detected visual function abnormalities in a similar number of eyes with glaucomatous optic neuropathy. 7 Similar to our finding with the FDP-Matrix, the SAP-SITA and the firstgeneration FDP tended to identify different subsets of eyes as abnormal. 7 Boden et al 7 hypothesized that, although SITA had shown no clinical loss of accuracy for detecting VF defects compared with the FT strategy, 8,9 the properties of SITA (eg, tighter confidence intervals) may have improved SAP ability in identifying glaucomatous VF defects. 7 Moreover, they suggested that a major contribution of the FDP, at least for glaucoma diagnosis, would be to serve as a complement to SAP-SITA for detecting eyes missed by the latter technique. Combining both perimetry techniques in our sample increased the sensitivity (60%), with slight reduction in specificity (80%). Previous studies have addressed the diagnostic performance of FDP-Matrix. 10,14,15 Spry et al 10 observed that FDP- Matrix and SAP using SITA-Fast strategy had a similar diagnostic performance in a population of 48 individuals with suspected glaucoma. However, as mentioned by the authors, a potential source of bias in favor of SAP may have occurred because the ophthalmologist who determined the diagnosis of glaucoma had access to SAP results. 10 Considering SAP results to classify patients as having normal or glaucomatous eyes would overestimate SAP diagnosis performance. On the other hand, the requirement of normal SAP findings for diagnosis of suspected glaucoma would prevent SAP deficits from preceding those of the functionspecific tests. Brusini et al 14 compared the diagnostic capability of the original FDP with the FDP-Matrix, but the study design did not permit direct comparisons between FDP and SAP-SITA because SAP-SITA results were part of the study inclusion criteria. In addition, it was not mentioned whether the VF defects detected at FDP were required to be repeatable. 14 Medeiros et al 15 observed that FDP- Matrix had a better performance than SAP-SITA for the diagnosis of early glaucoma. However, inasmuch as the main purpose of this study was to describe a statistical approach to evaluate the effect of covariates (disease severity and age) on receiver-operating characteristic curves, only the global index pattern standard deviation was used to determine abnormal visual function. 15 Thus, this previous study did not provide a comprehensive comparison of SAP- SITA and FDP-Matrix as used in clinical practice in early glaucoma detection. We found slightly higher sensitivity with FDP-Matrix using the pattern deviation probability plot criterion, but this was of borderline significance. A larger study population will be required to verify this finding. In our study, although the mean test time of SAP and FDP-Matrix increased with VF damage (as measured by 344

mean deviation), FDP-Matrix had a shorter variability in test duration over the mean deviation range and a shorter variability in test duration between subjects with worse mean deviation (Figure 1). The shorter variability in test duration observed in FDP-Matrix examinations may be explained by the properties of its algorithm, presenting a constant number of stimuli per each VF location, and also by the smaller increase in threshold variability with increasing disease severity seen with the FDP. 11 There were no significant differences between the number of abnormal points on the pattern deviation and total deviation plots detected at SAP-SITA and FDP-Matrix in eyes with GAOD. In contrast with previous studies, 10,14,15 our results suggest that FDP-Matrix may not detect more extensive damage than SAP-SITA. We observed discrepancies between visual function status as evaluated by FDP and SAP in 10 healthy eyes. Five control subjects had a consistent defect at SAP but normal findings at FDP examination, and 5 had a consistent defect at FDP but normal SAP findings. Figure 4 shows an example of each discrepancy observed in healthy eyes. Differences between normative databases of SAP-SITA and FDP-Matrix (different populations enrolled for each normative database) might have influenced our results. 11 Ideally, a large normative database for both VF tests obtained from the same individuals should be used to provide a more accurate comparison between VF techniques. However, a customized normative database would not be generalizable and would limit the purpose of the study, which was to evaluate how these instruments performed as they are being used in clinical practice. In addition, classification of eyes according to whether they were healthy or had GAOD was based on evaluation of stereoscopic photographs. Because of the wide variability in the optic disc appearance in the nonglaucomatous population, some eyes included in the GAOD group may never develop glaucoma, explaining, in part, the low sensitivity levels observed in the present study. Also, some of the eyes classified as GAOD may be in a stage of the disease process where the detection of functional loss by these instruments is not yet possible. Although these factors might influence the sensitivity and specificity of each technique, it is unlikely they would have affected the comparisons between the 2 instruments. The exclusion of control subjects with inconsistent results on 2 VF tests by any technique may have affected our results. However, consistent results were required in an attempt to minimize the influence of testing artifacts (eg, learning effect), and a similar number of control subjects were excluded because of inconsistent results at SAP and FDP. In summary, this study shows that FDP-Matrix enabled detection of abnormal visual function in more eyes with GAOD than did SAP-SITA, although this difference was not significant. Each VF test tended to identify a different subset of patients with eyes with GAOD as abnormal. Combination of these perimetry techniques may improve the detection of visual function abnormalities in glaucoma, with slight reduction in specificity. Submitted for Publication: August 29, 2006; final revision received October 17, 2006; accepted November 4, 2006. Correspondence: Christopher A. Girkin, MD, MPSH, Department of Ophthalmology, School of Medicine, University of Alabama at Birmingham, 700 18th St S, Suite 406, Birmingham, AL 35233 (cgirkin@uab.edu). Financial Disclosure: None reported. Funding/Support: This study was supported in part by unrestricted grants from Research to Prevent Blindness Inc; the EyeSight Foundation of Alabama, Birmingham; and grants K23-EY 13959-0 and U-10 EY14267-02 from the National Eye Institute (Dr Girkin). REFERENCES 1. Johnson CA, Samuels SJ. Screening for glaucomatous visual field loss with frequency-doubling perimetry. Invest Ophthalmol Vis Sci. 1997;38:413-425. 2. Kelly DH. Frequency doubling in visual responses. J Opt Soc Am A. 1966;56:1628-1633. 3. Maddess T, Severt WL. Testing for glaucoma with frequency-doubling illusion in the whole, macular and eccentric visual fields. AustNZJOphthalmol. 1999; 27:194-196. 4. Anderson AJ, Johnson CA, Fingeret M, et al. Characteristics of the normative database for the Humphrey matrix perimeter. Invest Ophthalmol Vis Sci. 2005; 46:1540-1548. 5. Sample PA, Bosworth CF, Blumenthal EZ, Girkin CA, Weinreb RN. Visual functionspecific perimetry for indirect comparison of different ganglion cell populations in glaucoma. Invest Ophthalmol Vis Sci. 2000;41:1783-1790. 6. Cello KE, Nelson-Quigg JM, Johnson CA. Frequency doubling technology perimetry for detection of glaucomatous visual field loss. Am J Ophthalmol. 2000; 129:314-322. 7. Boden C, Pascual J, Medeiros FA, Aihara M, Weinreb RN, Sample PA. Relationship of SITA and full-threshold standard perimetry for frequency-doubling technology perimetry in glaucoma. Invest Ophthalmol Vis Sci. 2005;46:2433-2439. 8. Bengtsson B, Olsson J, Heijl A, Rootzen H. A new generation of algorithm for computerized threshold perimetry, SITA. Acta Ophthalmol Scand. 1997;75: 368-375. 9. Bengtsson B, Heijl A, Olsson J. Evaluation of a new threshold visual field strategy, SITA, in normal subjects. Acta Ophthalmol Scand. 1998;76:165-169. 10. Spry PG, Hussin HM, Sparrow JM. Clinical evaluation of frequency doubling technology perimetry using the Humphrey Matrix 24-2 threshold strategy. Br J Ophthalmol. 2005;89:1031-1035. 11. Artes PH, Hutchinson DM, Nicolela MT, LeBlanc RP, Chauhan BC. Threshold and variability properties of matrix frequency doubling technology and standard automated perimetry in glaucoma. Invest Ophthalmol Vis Sci. 2005;46:2451-2457. 12. Hodapp E, Parrish RK II, Anderson DR. Clinical Decisions in Glaucoma. St Louis, Mo: Mosby Year Book Inc; 1993:53-59. 13. Glass GVB, Stanley JC. Statistical Methods in Education and Psychology. Englewood Cliffs, NJ: Prentice-Hall International Inc; 1970. 14. Brusini P, Salvetat ML, Zeppieri M, Parisi L. Frequency doubling technology perimetry with the Humphrey Matrix 30-2 test. J Glaucoma. 2006;15:77-83. 15. Medeiros FA, Sample PA, Zangwill LM, Liebmann JM, Girkin CA, Weinreb RN. A statistical approach to the evaluation of covariate effect on the receiver operating characteristic curves of diagnostic tests in glaucoma. Invest Ophthalmol Vis Sci. 2006;47:2520-2527. 345