Ritu Raj Upreti, S. Dayananda, R. L. Bhalawat*, Girish N. Bedre*, D. D. Deshpande

Similar documents
Assessment of dose homogeneity in conformal interstitial breast brachytherapy with special respect to ICRU recommendations

Evaluation of three APBI techniques under NSABP B-39 guidelines

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 6, NUMBER 2, SPRING 2005

Abstract Purpose: Material and methods: Results: Conclusions: Key words: Purpose Address for correspondence:

Quality management for Breast Brachytherapy.

Real-time brachytherapy for prostate cancer implant analysis

Dosimetric Analysis Report

3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER

DOSIMETRICAL EVALUATION AND CLINICAL IMPLEMENTATION OF A STRUT-ADJUSTED-VOLUME-IMPLANT SAVI DEVICE USED FOR ACCELERATED PARTIAL BREAST IRRADIATION

Physics Contributions

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Radiation Planning Index for dose distribution evaluation in stereotactic radiotherapy

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

VIJAY R. KINI, M.D Edinger Ave Tustin, CA

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

NSABP PROTOCOL B-39B RTOG PROTOCOL 0413

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Original articles. Abstract. Purpose

Bladder and rectum dose estimations on digitized radiographs for vaginal brachytherapy after hysterectomy

Leila E. A. Nichol Royal Surrey County Hospital

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

Clinical outcomes of patients treated with accelerated partial breast irradiation with high-dose rate brachytherapy: Scripps Clinic experience

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Comparison of two techniques of interstitial pulsed dose rate boost brachytherapy in conservative treatment of breast cancer

A new homogeneity index based on statistical analysis of the dose volume histogram

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

REVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction

The Impact of Image Guided Radiotherapy in Breast Boost Radiotherapy

Breast Brachytherapy: How to Allay Fears of Patients and Colleagues, and What Are Our Expectations for the Future?

Verification of Balloon Integrity by Ultrasound Imaging in Accelerated Partial Breast Irradiation

Acknowledgements. QA Concerns in MR Brachytherapy. Learning Objectives. Traditional T&O. Traditional Summary. Dose calculation 3/7/2015

3D CONFORMATIONAL INTERSTITIAL BRACHYTHERAPY PLANNING FOR SOFT TISSUE SARCOMA

A B S T R A C T. 1. Introduction

Changing Paradigms in Radiotherapy

A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation

Accurate Accurate boost or Simply Accuboost

Image based Brachytherapy- HDR applications in Gynecological Tumors

Basic Concepts in Image Based Brachytherapy (GEC-ESTRO Target Concept & Contouring)

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Automatic Definition of Planning Target Volume in Computer-Assisted Radiotherapy

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

Non-Invasive Brachytherapy of the Breast

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast

Dosimetric performance of Strut-Adjusted Volume Implant: A new single-entry multicatheter breast brachytherapy applicator

Defining Target Volumes and Organs at Risk: a common language

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Application of asi-kvcbct for Volume Assessment and Dose Estimation: An Offline Adaptive Study for Prostate Radiotherapy

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies

8/2/2017. Improving Dose Prescriptions for Safety, Reporting, and Clinical Guideline Consistency. Part III

Chapter 2. Level II lymph nodes and radiation-induced xerostomia

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

Commissioning of brachytherapy Treatment Planning Systems

DOSIMETRIC OPTIONS AND POSSIBILITIES OF PROSTATE LDR BRACHYTHERAPY WITH PERMANENT I-125 IMPLANTS

I. Equipments for external beam radiotherapy

Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

Recent proceedings in Brachytherapy Physics

Johannes C. Athanasios Dimopoulos

Address for Correspondence: Department of Medical Physics, Khwaja Yunus Ali University, Enayetpur, Sirajgonj ,

Comparing Study between Conventional and Conformal Planning Radiotherapy

Brachytherapy Planning and Quality Assurance w Classical implant systems and modern computerized dosimetry w Most common clinical applications w

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

OPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING

Institute of Oncology & Radiobiology. Havana, Cuba. INOR

Evaluation of Normal Tissue Complication Probability and Risk of Second Primary Cancer in Prostate Radiotherapy

Brachytherapy Planning and Quality Assurance

Knowledge-Based IMRT Treatment Planning for Prostate Cancer: Experience with 101. Cases from Duke Clinic. Deon Martina Dick

Measurement of craniocaudal catheter displacement between fractions in computed tomography based high dose rate brachytherapy of prostate cancer

Chapters from Clinical Oncology

Online in vivo dosimetry in conformal radiotherapies with MOSkin detectors

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Dosimetric evaluation of multilumen intracavitary balloon applicator rotation in high-dose-rate brachytherapy for breast cancer

HDR Brachytherapy: Results and Future Studies in Monotherapy

To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence

Radiation Damage Comparison between Intensity Modulated Radiotherapy (IMRT) and Field-in-field (FIF) Technique In Breast Cancer Treatments

INFLUENCE OF CT SLICE THICKNESS ON VOLUME AND DOSE UNCERTAINTY FOR DIFFERENT ORGANS DURING TREATMENT PLANNING FOR EARLY PROSTATE CANCER

The Accuracy of 3-D Inhomogeneity Photon Algorithms in Commercial Treatment Planning Systems using a Heterogeneous Lung Phantom

IROC Prostate Phantom. Guidelines for Planning and Treating the IROC IMRT Prostate Phantom. Revised March 2014

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist

ADVANCED TECHNOLOGY CONSORTIUM (ATC) CREDENTIALING PROCEDURES FOR LUNG BRACHYTHERAPY IMPLANT PROTOCOLS

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

A commissioning procedure for breast intracavitary electronic brachytherapy systems

Corporate Medical Policy

Transcription:

60 Original Article Evaluation of radiograph-based interstitial implant dosimetry on computed tomography images using dose volume indices for head and neck cancer Ritu Raj Upreti, S. Dayananda, R. L. Bhalawat*, Girish N. Bedre*, D. D. Deshpande Departments of Medical Physics and *Radiation Oncology, Tata Memorial Hospital, Mumbai, India Received on: 09-02-07 Accepted on: 20-03-07 ABSTRACT Conventional radiograph-based implant dosimetry fails to correlate the spatial dose distribution on patient anatomy with lack in dosimetry quality. Though these limitations are overcome in computed tomography (CT)-based dosimetry, it requires an algorithm which can reconstruct catheters on the multi-planner CT images. In the absence of such algorithm, we proposed a technique in which the implanted geometry and dose distribution generated from orthogonal radiograph were mapped onto the CT data using coordinate transformation method. Radiograph-based implant dosimetry was generated for five head and neck cancer patients on Plato Sunrise treatment planning system. Dosimetry was geometrically optimized on volume, and dose was prescribed according to the natural prescription dose. The final dose distribution was retrospectively mapped onto the CT data set of the same patients using coordinate transformation method, which was verified in a phantom prior to patient study. Dosimetric outcomes were evaluated qualitatively by visualizing isodose distribution on CT images and quantitatively using the dose volume indices, which includes coverage index (CI), external volume index (EI), relative dose homogeneity index (HI), overdose volume index (OI) and conformal index (COIN). The accuracy of coordinate transformation was within ±1 mm in phantom and ±2 mm in patients. Qualitative evaluation of dosimetry on the CT images shows reasonably good coverage of target at the expense of excessive normal tissue irradiation. The mean (SD) values of CI, EI and HI were estimated to be 0.81 (0.039), 0.55 (0.174) and 0.65 (0.074) respectively. The maximum OI estimated was 0.06 (mean 0.04, SD = 0.015). Finally, the COIN computed for each patient ranged from 0.4 to 0.61 (mean 0.52, SD = 0.078). The proposed technique is feasible and accurate to implement even for the most complicated implant geometry. It allows the physicist and physician to evaluate the plan both qualitatively and quantitatively. Dose volume indices derived from CT data set are useful for evaluating the implant and comparing different brachytherapy plans. COIN index is an important tool to assess the target coverage and sparing of normal tissues in brachytherapy. Key words: Dose volume indices, head and neck cancer, interstitial implant dosimetry Interstitial implant dosimetry has been conventionally carried out using a set of radiographs which represent the spatial distribution of the implanted catheters within the patient. The correlation of the dose distribution thus obtained with the patient anatomy is relatively subjective and lacks quantitative measure with respect to the target volume coverage. Limited work on three-dimensional computed tomography (3D-CT) based interstitial implant dosimetry demonstrated its potential in providing spatial dose distribution on patient anatomy and quantitative evaluation based on the dose-volume relationship of different anatomical structures. [1-4] However, this method is not always feasible in the absence of a catheter reconstruction algorithm which supports reconstruction on the multi-planar reconstructed CT images. This algorithm is particularly important for complex implants such as head and neck or extremities where the implanted plane is oblique or parallel to the imaging plane and loops are in use. However, this algorithm may not be available in all the commercial treatment planning systems (TPS s) or it comes with an extra cost. To evaluate implant quality based on the dosevolume relation of patient anatomy in the absence of such reconstruction algorithm, we proposed a technique wherein implant geometry was reconstructed from the orthogonal radiograph and the final dose distribution was mapped onto the CT data of the same patient using the coordinate transformation method. Address for correspondence: Ritu Raj Upreti, Department of Medical Physics, Tata Memorial Hospital, Dr. Ernest Borges Marg, Parel, Mumbai - 400 012, India. E-mail: rituraaj123@yahoo.com

Upreti RR, et al.: Evaluation of radiograph based implant dosimetry on CT images 61 Materials and Methods Five patients of various head and neck cancers (tongue, valleculla and epiglottis) were selected for this study. These cases represent complex geometry wherein implanted catheters were oblique and parallel to the imaging plane. The use of loop catheters further complicated the implant geometry and posed difficulties in reconstruction from CT images. All patients had three-plane implant with number of catheters ranging from 9 to 16 (average 11). Catheters in a plane were arranged more or less parallel and equidistant to each other, and loop technique was employed in the posterior-most catheters. Post-implant orthogonal radiographs were taken for each patient on simulator (Ximatron, Varian Medical System, USA) with radio-opaque dummy markers in the implanted catheters [Figure 1]. Reference points were also marked on the patients skin at different axial levels, and radioopaque markers were placed prior to acquiring radiographs. Soon after, axial CT images were acquired with 3 mm slice thickness on Somatom Emotion CT scanner (Siemens Medical Systems, Germany) with radio-opaque reference markers in place and dummies removed from the catheters. The target and critical organs were contoured on the axial CT images. Figure 2 represents one of the axial CT images containing the contours and radio-opaque reference markers. The geometry of the implanted catheters was reconstructed from orthogonal radiographs, and dosimetry was carried out on Plato Sunrise brachytherapy (BT) TPS (Nucletron, Holland) as is usually done for conventional planning. All the reference markers were digitized both in x-ray and CT images. Besides external reference markers, radio-opaque buttons on both ends of the implanted catheters were taken as internal reference markers for the subsequent mapping of x-rays and CT data sets. All catheters were loaded with alternate dwell positions of step size 2.5 mm, leaving 5 to 10 mm from the open end of the tube to minimize skin dose. The treatment plan was geometrically optimized and prescribed on the natural prescription dose (NPD) derived from the Anderson natural dose volume histogram (DVH). [5] The final plan was then superimposed retrospectively onto the CT data set by co-registering the reference radio-opaque markers of the radiograph with the corresponding reference markers on the CT data sets using coordinate transformation method available with Plato Sunrise BT TPS. The accuracy of the coordinate transformation was investigated prior to patient study on a customized phantom. The phantom simulated single-plane implant of predefined geometry consisting of eight flexible catheters and known reference markers. Qualitative evaluation of the dosimetric outcome was carried out by visualizing the mapped isodose distribution in each slice of CT. Quantitative evaluation of the implant dosimetry was carried out using various indices derived from the dose volume relationship of the patient s CT images. The indices included the coverage index (CI), external volume index (EI), relative dose homogeneity index (HI) and overdose volume index (OI). [6] For quantitative evaluation of conformality, the conformal index (COIN) was used. [7] CI is the fraction of PTV receiving a dose equal to or greater than the reference dose: CI = PTV 100 EI is the ratio of the normal tissue volume outside the PTV receiving a dose equal to or greater than the reference dose, to the PTV: EI = (V 100 - PTV 100 ) HI is the fraction of PTV receiving a dose between 100 Figure 1: Orthogonal radiographs with X-ray dummy s and radio opaque reference markers Figure 2: CT image containing the contours and radio-opaque reference markers

62 Upreti RR, et al.: Evaluation of radiograph based implant dosimetry on CT images and 150% of the reference dose: EI = (PTV - PTV ) 100 150 PTV 100 OI is the fraction of PTV receiving a dose equal to or greater than two times the reference dose: OI = PTV 200 PTV 100 0-0.97 mm). Figure 3 represents the two-dimensional (2D) and three-dimensional (3D) dose distribution resulted from radiograph-based plan. The 3D distribution of reconstructed implant geometry transformed onto the CT data sets is shown in Figure 4, whereas Figures 5A, 5B and 5C represent the mapped dose distribution on the axial, sagittal and coronal planes respectively. The radiograph-based dosimetry was evaluated qualitatively by observing mapped isodoses on each and every CT slice to ensure adequate coverage of the target volume with the reference isodose value. The quantitative evaluation of the dosimetric outcome was The COIN takes into consideration the coverage of PTV derived from the cumulative DVH of the defined structures by the reference dose and also the unwanted irradiation of on the CT data set and is shown in Figure 6. Median volume normal tissue outside the PTV: of CTV measured from CT data set was 42.9 cc (range 38.6- PT 58.3 cc). Table 2 represents the different indices derived COIN = 200 100 x from the DVH of each patient. The mean CI was found to V 100 be 0.81 (range 0.77-0.87, SD = 0.039). Only in one patient, the estimated EI was less (0.3); while in the remaining In the above equations, PTV 100 is the volume of target patients, EI was more than 0.5. The mean EI for all patients receiving a dose equal to or greater than the reference dose, was estimated to be 0.55 (range 0.3-0.76, SD = 0.174). The PTV is the volume of PTV receiving 1.5 times of the HI was found to be in range of 0.55-0.74 (mean 0.65, SD = 150 reference dose, PTV 200 is the volume of PTV receiving equal 0.074). The maximum OI estimated was 0.06 (mean 0.04, to or greater than two times the reference dose, V 100 is the SD = 0.015). Finally the COIN computed for each patient volume of tissue that received reference dose and is was in the range of 0.4-0.61 (mean 0.52, SD = 0.078). the total volume of PTV. Discussion Results Unlike other clinical sites, head and neck implant still The accuracy of coordinate transformation found in remains one of the most complicated procedures because of the phantom study was within ±1 mm. Table 1 shows the complex relationship of anatomical structure with disease. the variation in the coordinate transformation between Since the inception of interstitial implants at our center in orthogonal radiograph and corresponding CT data of the five the year 1980, dosimetry had been carried out using a set patients. The goodness of the fit was estimated from chi- of orthogonal radiographs. The dosimetric outcome of the square test of transformation matrix. The maximum of the implant was evaluated qualitatively by observing the isodose mean variation observed in all patients was 0.97 mm (range distribution in three orthogonal planes of the implanted geometry. However, this dosimetric system did not provide Table 1: Variation in the coordinate a three-dimensional relationship between the implanted transformation between orthogonal radiograph volume and the anatomic boundaries of the target volume. and corresponding CT data of different patients As a result, implant quality estimated using Anderson DVH Reference Patients might not necessarily correlate with tumor coverage. Hence, markers P1 P2 P3 P4 P5 M1 0.9 0.8 0 1.3 0.3 to enable a more clinically realistic evaluation of the implant M2 0.8 0.5 0 1.5 0 dosimetry, anatomy (CT) based dosimetry need to be adopted. M3 0.4 0 0-0.1-0.3 Mean 0.7 0.43 0 0.97 0.2 Chi square 0.7 0.8 0.8 1.2 0.9 Table 2: Indices calculated from the dose volume histogram of target and normal tissue of different patients Indices Patients Mean SD P1 P2 P3 P4 P5 CI a 0.83 0.87 0.79 0.77 0.8 0.81 0.039 EI b 0.51 0.66 0.76 0.3 0.52 0.55 0.174 HI c 0.61 0.74 0.68 0.55 0.69 0.65 0.074 OI d 0.04 0.04 0.02 0.06 0.03 0.04 0.015 COIN e 0.51 0.61 0.4 0.55 0.55 0.52 0.078 a CI-Coverage index, b EI External volume index, c HI Relative dose homogeneity index, d OI-Overdose volume index, e COIN Conformal index A very limited number of articles on CT-based dosimetry of interstitial implants have been reported; mostly, these have been for breast cancer. [1-4] At the time when 3D CT-based TPS was not available for BT, Vicini et al. [1] retrospectively translated the source positions and dwell times planed on 2D BT TPS (Nucletron) using radiographs onto the CT data set of the same patient on a different 3D TPS (ADAC Pinnacle) for quantitative evaluation. In their study, standard needle template implant was used in breast cancer, and the transformation was carried out using in-house developed software. In our proposed technique, more complicated implant geometry was tested using a single TPS and coordinate transformation method. Moreover, in most of the reported studies, only few dosimetric quality parameters

Upreti RR, et al.: Evaluation of radiograph based implant dosimetry on CT images 63 Figure 3: 2D and 3D dose distribution resulted from radiograph generated plan Figure 4: The 3D distribution of reconstructed implant geometry transformed on to the CT dataset Figure 5B: Mapped dose distribution on the sagittal plane Figure 5C: Mapped dose distribution on the coronal plane Figure 5A: Mapped dose distribution on the axial plane Figure 6: Cumulative dose volume histogram (DVH) of the defined structures on the CT dataset

64 Upreti RR, et al.: Evaluation of radiograph based implant dosimetry on CT images related to coverage and homogeneity were addressed. Though modern TPS s support reconstruction of catheter in multiple CT reconstructed plane, our Plato TPS did not have this option at the time of this study. The maximum variation between the corresponding reference markers during the coordinate transformation was observed to be 1.5 mm. While performing coordinate transformation, out of many reference internal and external markers, those which resulted in least variation were selected for the final mapping. The projection of the catheters represented by a train of active sources was verified on the CT images. A maximum dosimetric inaccuracy of 1.6% was reported by Vicini et al. [1] as a result of ±2 mm mismatch in the implant template when transformed from x-ray to CT data set. system (CDS) developed by Baltas et al. [7] aimed to achieve a COIN value above 0.64. However, COIN values reported by several authors ranged from 0.48 to 0.76. [4,7] Conclusion The proposed technique of CT image -based evaluation of a radiograph-generated plan for complex interstitial implant is a promising approach in the absence of multiplane catheter reconstruction software. This technique is feasible and accurate even for the most complicated implant geometry. It also allows the physicist and physician to evaluate the plan both qualitatively and quantitatively to achieve desired conformity as well as homogeneity without compromising on reconstruction accuracy. Dose volume indices derived from CT data set are useful for evaluating the implant as well as comparing different brachytherapy plans. COIN index is an important tool to assess the target coverage and sparing of The mean CI (0.81) estimated in our study was less than 0.95, as reported by Major et al. [8] for ideal implant geometry. normal tissues in brachytherapy. However, our mean CI is in agreement with the value suggested by Baltas et al. [7] Das et al. [2] also reported a CI References value of 0.96 in a series of early-stage breast cancer patients treated with image-guided interstitial implant technique for 1. Vicini FA, Kestin LL, Edmundson GK, Jaffray DA, Wong JW, Kini accelerated partial breast irradiation. In their study, graphical VR, et al. Dose volume analysis for quality assurance of interstitial brachytherapy for breast cancer. Int J Radiat Oncol Biol Phys optimization was used interactively to achieve higher dose 1999;45:803-10. conformality to the target volume. However, the interactive 2. Das RK, Patel R, Shah H, Odau H, Kuske RR. 3D CT based high-doseoptimization may perturb the homogeneity and lead to an rate breast brachytherapy implants: Treatment planning and quality increase in OI. The data from our dosimetry may not be assurance. Int J Radiat Oncol Biol Phys 2004;59:1224-8. 3. Cuttino LW, Todor D, Arthur DW. CT-guided multi-catheter insertion comparable directly with other s data as most of the studies technique for partial breast brachytherapy: Reliable target coverage were reported for breast cancers. Higher values of EI in our and dose homogeneity. Brachytherapy 2005;4:10-7. study indicate larger volumes of normal tissues irradiated 4. Kolotas C, Baltas D, Zamboglou N. CT-based interstitial HDR by the reference dose. This prescription dose volume to brachytherapy. Strahlenther Onkol 1999;175:419-27. 5. Anderson LL. A natural volume-dose histogram for brachytherapy. surrounding normal tissue could be avoided if the active Med Phys 1986;13:898-903. source-loading is performed based on the target volume 6. Meertens H, Borger J, Steggerda M, et al. Evaluation and optimization delineated from CT rather than deciding the active length of interstial brachytherapy dose distributions. In: Mould RF, from the radiograph. The value of EI reported by Major Battermann JJ, Martinez AA, Speiser BL, editors. Brachytherapy from [8] radium to optimization. Nucletron International: Veenendaal, The et al. for idealized implants ranged from 0.17 to 0.44 for Netherlands; 1994. p. 300-6. various dosimetry systems. 7. Baltas D, Kolotas C, Geramani K, Mould RF, Ioannidis G, Kekchidi M, et al. A Conformal Index (COIN) to evaluate implant quality Our mean value of HI (0.65) is in good agreement with the and dose specification in brachytherapy. Int J Radiat Oncol Biol Phys finding of Major et al. [8] 1998;40:515-24. They reported mean HI of 0.68 for 8. Major T, Polgar C, Fodor J, Somogyi A, Nemeth G. Conformality and an ideal implant geometry using stepping source dosimetry homogeneity of dose distributions in interstitial implants at idealized system. The maximum estimated value of OI is 0.06, and target volumes: A comparison between the Paris and dose-point it is well below the reported value (0.11-0.13). [8] The lower optimized systems. Radiother Oncol 2002;62:103-11. value of COIN in this study is due to larger normal tissue Source of Support: Nil, Conflict of Interest: None declared. irradiated by the prescription dose. Conformal dosimetry