MS310 (a) An Indicator Strip-Based Colorimetric Test for Nitrate Ions (NO 3 - ) in Water and Soil

Similar documents
METHOD 9079 SCREENING TEST METHOD FOR POLYCHLORINATED BIPHENYLS IN TRANSFORMER OIL

Instruction Manual Updated 8/27/2013 Ver. 1.1

Nitrate and Nitrite Key Words: 1. Introduction 1.1. Nature, Mechanism of Action, and Biological Effects (Fig. 1)

ESS Method 310.2: Phosphorus, Total, Low Level (Persulfate Digestion)

Instruction Number: 5681

The Guardian Euro Poll CATI Fieldwork: 24th Februuary - 8th March 2011

STANDARD PER CROMATOGRAFIA IONICA

Ceric Acid Titration Method Method mg/l as NaNO 2 Digital Titrator

Matrix Reference Materials - SCP SCIENCE

DROP TEST SODIUM NITRITE (1 drop = 40 ppm)

Hydroponics TEST KIT MODEL AM-41 CODE 5406

Mouse C-Peptide ELISA Kit

Ascorbic Acid Assay Kit

Standard Operating Procedure for Chloride and Silica in Lake Water (Lachat Method)

PRECIPITATON TITRATION

Model STH Series. Combination Soil Outfit. Instruction Manual

Sulfite. Iodate-Iodide Method 1 Method mg/l as SO 3. (or 0 to more than 500 mg/l) Buret Titration. Test preparation.

DROP TEST P/M & P/T ALKALINITY (1 drop = 10 ppm)

Procedure for Blood Analysis. 1.0 Purpose - This procedure specifies the methods for performing blood analysis in forensic casework.

Titrimetric Determination of Hypo Index, Thiosulfate, and Sulfite in EASTMAN Color Films, Process ECN-2 Fixer

Determination of Inorganic Ions and Organic Acids in Non-Alcoholic Carbonated Beverages

Rapid determination of phosphate and citrate in carbonated soft drinks using ion chromatography

3a. The acid and base react to form a salt solution of ammonium propionate. CaCO s + 2 HC H O aq CO g + H O l + Ca ( aq ) + 2 C H O ( aq)

ESS Method 230.1: Total Phosphorus and Total Kjeldahl Nitrogen, Semi-Automated Method

Reflectometry Reflectoquant

SECTIOn 3. Multi-Element ClP Standards for ICP & ICP-MS

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Feedstuffs Analysis G-22-1 PROTEIN

Method (6 to 1000 µg/l Chlorine as Cl 2 ) Digital Titrator

Glycosyltransferase Activity Kit

E55A GELATIN, GELLING GRADE Gelatina

TOTAL KJELDAHL NITROGEN DETERMINATION

Total Bilirubin Assay Kit Manual Catalog #:

Opiates Rapid Test. Cat. No.:DTS137 Pkg.Size:50T. Intended use. General Description. Principle Of The Test. Reagents And Materials Provided

TNF-alpha ELISA. For Research Use Only. Not For Use In Diagnostic Procedures.

(Writing model for laboratory note book)

WAGENINGEN EVALUATING PROGRAMS FOR ANALYTICAL LABORATORIES. Certificate of Analysis. International Soil-Analytical Exchange REFERENCE MATERIAL

Standard Operating Procedure for Total and Dissolved Phosphorous (Lachat Method)

Experiment: Iodometric Titration Analysis of Ascorbic Acid Chem251 modified 09/2018

Procedure for Blood Analysis. 1.0 Purpose - This procedure specifies the methods for performing blood analysis in forensic casework.

Table of Contents. LaMOTTE COMPANY

HBeAg and HBeAg Ab ELISA Kit

Lab 3: Inorganic Plant Nutrients: Nitrogen, Phosphorus, Silicate

USP <232> and <233> Understanding Your Path to Compliance with the New Elemental Impurity Chapters. Steve Wall Agilent Technologies

DROP TEST TOTAL HARDNESS (1 drop = 10 ppm)

DROP TEST P/M & P/T ALKALINITY (1 drop = 10 ppm)

Mouse Cathepsin B ELISA Kit

Properties of Alcohols and Phenols Experiment #3

Engineering of Ministry of Education, Institute of Molecular Science, Shanxi University, Taiyuan , China.

WAGENINGEN EVALUATING PROGRAMS FOR ANALYTICAL LABORATORIES. Certificate of Analysis. International Plant-Analytical Exchange REFERENCE MATERIAL

6.02 Uniformity of Dosage Units

ESS Method 310.1: Ortho-Phosphorus, Dissolved Automated, Ascorbic Acid

Qualitative test of protein-lab2

Properties of Alcohols and Phenols Experiment #3

Analysis of Milk for Major and Trace Elements by ICP-MS

Zeolite Clinoptilolite Powder

Controls (positive and negative) for quality assessment-located in central laboratory Note: See central lab UA procedure for QC. Read strips visually.

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

Superoxide Dismutase Kit

US EPA SW-846 Method 6010D using the Thermo Scientific icap 7400 ICP-OES Duo

European Pharmacopoeia solutions

Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection

Leaching Behavior of Coal Combustion Products and the Environmental Implication in Road Construction. Project Progress Report. Jianmin Wang NUTC R201

EXPERIMENT 13 QUALITATIVE ANALYSIS

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Rapid-VIDITEST. Strep A Blister. One step Strep A Blister for the detection of Group A Streptococcal antigen from throat swabs or culture.

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB

Physicochemical Characterization of Airborne. Particulate Matter at a Mainline Underground

Cranberry Nutrition: An A Z Guide. Joan R. Davenport Soil Scientist Washington State University

Determination of Copper in Green Olives using ICP-OES

Mercury Speciation Determinations in Asian Dietary Supplements

Mike Hinds, Royal Canadian Mint

Procine sphingomyelin ELISA Kit

CHEM104 Exp. 9 Phytochemical Antioxidants with Potential Benefits in Foods Part I. 1

EXOTESTTM. ELISA assay for exosome capture, quantification and characterization from cell culture supernatants and biological fluids

GSJ Geochemical Reference Samples. Igneous Rock. Sedimentary Rock. For Instrumental analysis. Reference value for environmental analysis -1

What Is the Relationship Between the Amount of Transmitted Light Through a Solution and Its Concentration?

Thiols (mercaptans) in Fuels (ASTM D )

Morinaga Mouse C-peptide ELISA Kit

RayBio Human Granzyme B ELISA Kit

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Test Report No.: GZHL IP Date: Sep 01, 2016 Page 1 of 12

Superoxide Dismutase Kit

Actual Excipient Test Data on Metal Impurities Submitted to IPEC-Americas from Industry

Hardness (Total & Calcium) Test Kit TK4040-Z 1 drop = 2 or 10 ppm as CaCO 3

INVESTIGATION OF CHLORINATED METHANES TREATABILITY USING ACTIVATED SODIUM PERSULFATE

Estrone EIA kit. For the quantitative determination of estrone in dried fecal extracts, urine and tissue culture media. Cat. No.

Nitrate/Nitrite Assay Kit Manual Catalog #

Properties of an Enzyme: Wheat Germ Acid Phosphatase Experiment #10

SOLUTION TEST STRIPS

Experiment 9 Amino Acids and Proteins

RayBio Human ENA-78 ELISA Kit

UREA CE Insert. 01 English - Ref.: 27. Ref.:27

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

MULTI-COMPONENT ANALYSIS OF HEAVY METALS

Phospholipid Assay Kit

Human TSH ELISA Kit. User Manual

PtPt-electrode with temperature sensor, Intellical MTC695

Transcription:

Field MS310 (a) An Indicator Strip-Based Colorimetric Test for Nitrate Ions (NO 3 - ) in Water and Soil 1.0 Scope and Application This is a field screening method to be used to test aqueous samples and soils for the presence of nitrate {Merckoquant 10020 (E. Merck, Frankfurter Strasse 250, D-6100 Darmstadt 1, Germany); EM Science - supplier (E. M. Science, 480 Democrat Road, Gibbstown, New Jersey 08027)}. It is also a useful method for laboratory use to determine an appropriate dilution of test water samples to be used for their analysis by more standard laboratory methods, thus eliminating costly reruns. 2.0 Summary of Method The outer reaction zone of the test strip contains a reducing agent that reduces nitrate to nitrite. In the presence of an acid buffer, the nitrite is then converted to nitrous acid, which diazotizes an aromatic amine (sulfanilic acid). The diazotized sulfanilic acid couples with N-[naphthyl(1)]- ethylenediamine (NNEDDC) to produce a red-violet azo dye. In practice, the reaction zone of the test strip is wetted in the test sample, removed, and blotted to remove excess liquid. The pale yellow-colored reaction zone changes to white for negative samples and to varying shades of redviolet in the range of 5 to 500 µg/ml (ppm) nitrate. After 1 min, the nitrate content of the sample is estimated by comparing the color of the strip with a standard color chart. The intensity of the color is proportional to the nitrate concentration in the range of 5 to 500 µg/ml (ppm). Soils are tested by extracting the soil with an equal amount of deionized water and testing the extract as described for aqueous samples. 3.0 Interferences Merck (Rapid Test Handbook, Merck, pp. 191, 192. 1987) has examined a number of chemicals for their interference in the nitrate test. Nitrite: As little as 0.5 µg/ml (ppm) nitrite produces a false-positive reaction. The test strip contains two reaction zones. The zone at the very end indicates both nitrate and nitrite, while the other reacts only to nitrite. A pink to red-violet coloration in the latter zone indicates the presence of nitrite, which interferes with the nitrate determination. Interference by nitrite can be eliminated by mixing 1 ml of test sample solution (ph <10) with one drop of an aqueous 10% (a) This method was supplied by L. C. Waters, R. A. Jenkins, R. R. Smith, R. W. Counts and J. H. Stewart (Oak Ridge National Laboratory, Oak Ridge, Tennessee). MS310-1

DOE Methods amidosulfonic acid solution. The solution is shaken several times and then tested for nitrate after 2 min as described in the procedure (section 7.0). This method allows the detection of 10 µg/ml (ppm) nitrate in the presence of 1000 µg/ml (ppm) nitrite. Other anions: At concentrations less than 1000 µg/ml (ppm) Br-, BrO 3 -, Cl -, ClO 3 -, ClO 4 -, CN -, F -, I -, Mo 7 O 24 6-, N 3 -, OCN -, PO 4 3-, SO 4 2-, SeO 3 2-, WO 4 2-, acetate, ascorbate, citrate, oxalate, succinate, and tartrate do not interfere. In the presence of more than 100 µg/ml (ppm) [Fe(CN) 6 ] 4-, 25 µg/ml (ppm) S 2-, 100 µg/ml (ppm) SCN -, 500 µg/ml (ppm) SO 3 2-, 250 µg/ml (ppm) S 2 O 3 2-, 100 µg/ml (ppm) S 2 O 4 2-, or 250 µg/ml (ppm) S 2 O 5 2-, the nitrate concentration indicated is less than that actually present. Oxidizing anions turn the reaction zone light brown to orange brown. This type of interference is caused by more than 20 µg/ml (ppm) CrO 4 2-, 100 µg/ml (ppm) [Fe(CN) 6 ] 3-, 500 µg/ml (ppm) IO 3 -, 10 µg/ml (ppm) MnO 4 -, 100 µg/ml (ppm) S 2 O 8 2-, or 25 µg/ml (ppm) VO 3 -. These interferences can be largely overcome by adding approximately 50 mg of hydrazine sulfate to 5 ml of test sample solution, mixing and testing according to the procedure (section 7.0). The quantity of nitrate indicated will, however, be less than is actually present. Cations: At concentrations less than 1000 µg/ml (ppm), the following cations do not interfere: Al 3+, As 3+, Ba 2+, Ca 2+, Co 2+, Cr 3+, K +, Li +, Mg 2+, Mn 2+, Na +, Ni 2+, Pb 2+, Rb +, Sb 3+, Sn 2+, Ti 4+, and Zn 2+. The color is less intense in the presence of more than 500 µg/ml (ppm) Fe 2+, 50 µg/ml (ppm) Fe 3+, 50 µg/ml (ppm) VO 2+, or 500 µg/ml (ppm) Zr 4+. More than 50 µg/ml (ppm) Ag +, 50 µg/ml (ppm) Hg +, or 100 µg/ml (ppm) Hg 2+, interferes by turning the reaction zone grey. ph: The test is independent of ph in the range of 1 to 12. More strongly acidic solutions should be buffered with sodium acetate and more strongly basic solutions with tartaric acid. 4.0 Apparatus and Materials Timer: Capable of measuring in seconds Pipettes: Plastic 5- or 10-mL disposables with filler bulb to measure water sample volume Test tubes, plastic, disposable, 13 x 100 mm (Falcon 2027 or equivalent) Permanent ink marking pen: For labeling test strips and tubes ph paper (0 to 14 range): For measuring ph of test sample Merckoquant 10020 Nitrate Test Kit (E. Merck, Frankfurter Strasse 250, D-6100 Darmstadt 1, Germany E. M. Science, 480 Democrat Road, Gibbstown, New Jersey 08027): MS310-2

Field Instructions: Supplied with kit. Test strips (100): Impregnated with nitrate-specific color reagents. A separate reaction zone indicates whether nitrite is present. Color chart: This chart, permanently affixed to the test strip container, provides reference hues for values of 0, 10, 25, 50, 100, 250, and 500 µg/ml (ppm). A separate chart provides an indication of the amount of nitrite present. 5.0 Reagents Except in cases of strongly acidic or basic samples, all required reagents are included in the test kit (section 4.0). In these cases, the samples should be adjusted as indicated in section 3.0. 6.0 Sample Collection, Preservation, and Handling The test is designed to be performed in the field. Because the samples are not modified, they may be disposed of at their collection source. 7.0 Procedure (Merckoquant 10020 Nitrate Test Instructions) 7.1 Single Samples 7.1.1 Two to three milliliters of the solution to be tested are added to a clean test tube. 7.1.2 The ph is tested with ph paper. If outside the 1 to 12 range, an adjustment should be made to that range with sodium acetate or tartaric acid (section 3.0, paragraph 5). 7.1.3 The test strip is immersed into the sample until the reaction zone is thoroughly moistened (about 1 sec). The excess liquid is removed by wiping the test strip against the test-tube rim. 7.1.4 After 1 min, the color of the reaction zone at the very end of the strip should be compared with the color chart. Coloration of the second reaction zone indicates nitrite, which must be removed from the sample to obtain an accurate measure of nitrate (section 3.0, paragraph 2). (If significant sample dilution has occurred during ph adjustment, this should be taken into account in the final estimate of the nitrate concentration in the sample.) MS310-3

DOE Methods 7.2 Multiple Samples: In situations where multiple samples or replicates of single samples are to be tested, an alternate procedure is suggested. 8.0 Quality Control 7.2.1 An appropriate number of disposable, plastic tubes and a corresponding number of test strips should be labeled using a permanent-ink marker. 7.2.2 Two to three milliliters of the solutions to be tested are added to the tubes. 7.2.3 The ph is tested and adjusted as required. 7.2.4 The strip test is performed as indicated in sections 7.1.3 and 7.1.4. The strip should be read as quickly as possible after the 1-min reaction period. (Consistent readings are obtained when made within a 30-min time period.) Samples of test strips from each batch should be tested using solutions of known nitrate concentration. Batches that do not produce true colors should not be used. Likewise, test samples that do not produce true colors should be suspected of containing interferants. 9.0 Method Performance 9.1 Spiked and naturally contaminated water samples were used to evaluate this method. A stock solution of sodium nitrate, at a nominal concentration of 1000 µg/ml (ppm), was made in simulated groundwater (SGW) {deionized water to which 0.165 g/l of sodium chloride and 0.148 g/l of sodium sulfate has been added (contains 100 µg/ml [ppm] each of SO 4 2- and Cl - ) (Rocky Mtn. 1989)}. Nitrate in the stock solution was determined by ion chromatography to be 1050 µg/ml (ppm). Results of tests made using deionized water were essentially identical to those presented below using SGW. Test solutions were made by diluting the stock solution to various concentrations with SGW. Triplicate 2.5-mL samples were added to 13- x 100-mm tubes (a single sample was used to test the 1:10 dilutions of contaminated water). The samples were randomized and tested using the test strips as described in section 7.2. Four or five analysts independently read the strips and recorded the concentrations with reference to the color chart. The nitrate concentrations defined by the color chart are 0, 10, 25, 50, 100, 250, and 500 µg/ml (ppm). Increments between these values were also used. To evaluate the accuracy of the method, numerical values were assigned to the results obtained from each strip as follows: a result of 50 µg/ml (ppm) was given the value 50; a result of 50 to 100 was given the value 75 and so on. The values were summed and averaged to produce the data presented in Tables 1 and 2 and Figures 1 and 2. MS310-4

Field Among the conclusions that can be made about the strip-test assay for nitrate in spiked SGW are the following (see Table 1 and Figure 1): 1. False positives occurred at a very low frequency. Two of 52 analyses of blank samples were tested positive (see Tables 1 and 2). 2. Five ppm were consistently distinguished from zero. There were no false-negative results with samples that contained >5 ppm (Table 1). 3. Below 100 µg/ml (ppm), good agreement existed between the estimates made with the strip test and the results obtained by ion chromatography (Table 1 and Figure 1). 4. Above 200 µg/ml (ppm), the test appears to overestimate the nitrate concentration (Table 1 and Figure 1). 5. Overall with reference to ion chromatography, the strip-test assay gave a best-fit straight line with an R 2 = 0.959 and a slope of 1.188 (Figure 1). The strip-test assay was very accurate in estimating the nitrate content of 10 contaminated water samples (see Table 2 and Figure 2). Only above 350 µg/ml (ppm) did the results deviate significantly from those determined by ion chromatography. Regression analysis of the strip-test data with reference to ion chromatography (Figure 2) gave a best-fit straight line with an R 2 = 0.972 and a slope of 0.898. These results clearly indicate the potential of using this test in the laboratory as a prescreen to determine the appropriate sample dilutions to be used in standard laboratory analysis. Taken together with the manufacturer s claims concerning the lack of interferences by a wide variety of inorganic ions, this method appears to be a rapid and effective field method for screening water samples that contain nitrate at >5 µg/ml (ppm). 9.2 Assay sensitivity and range: Nitrate was consistently detected in samples with >5 µg/ml (ppm) nitrate. The working range of the test is 5 to 500 µg/ml (ppm). 10.0 Reference Rocky Mountain Arsenal. 1989. Rocky Mountain Arsenal Chemical Quality Assurance Plan, section 4-7. Commerce City, Colorado 80022-2180. MS310-5

DOE Methods Table 1. Strip Test Assay for Nitrate in Spiked Water Nitrate Concentration (a) Actual (b) Calculated Average Conc. Conc. Conc. Sample No. Test No. µg/ml (ppm) µg/ml (ppm) µg/ml (ppm) 0 0-10 10 10-25 25 25-50 50 (5) (17.5) (37.5) Experiment 1 1 27 0 0 A,B,C,D (c) 2 34 0 0 A,B,C,D 3 36 0 0 A,B,C,D 4 10 0 1.2 A,C,D B 5 23 0 1.2 A,C,D B 6 5 0 0 0.4 A,B,C,D 7 37 5.25 8.8 A B,C,D 8 35 5.25 5 A,B,C,D 9 29 5.25 5 6.3 A,B,C,D 10 13 10.5 6.2 A,C,D B 11 21 10.5 5 A,B,C,D 12 24 10.5 6.2 5.8 A,C,D B 13 26 21 13.8 C,D A,B 14 20 21 17.5 C A,D B 15 14 21 17.5 16.3 C A,D B 16 16 31.5 19.4 C A B,D 17 1 31.5 34.4 C,D A B 18 39 31.5 21.2 25 A,C B.D 19 9 52.5 40.6 D A B,C 20 22 52.5 40.6 A,B,D C 21 6 52.5 34.4 38.5 C A,B,D 22 19 78.75 68.8 C 23 18 78.75 65.6 B C (a) The nitrate concentration (µg/ml) (ppm) was estimated by comparison of the test strip color with the reference color chart. (b) Determined by ion chromatography (c) Each test strip (one strip per water sample) was independently read by four evaluators (A,B,C,D) as indicated. MS310-6

Field Table 1. (contd) Nitrate Concentration (a) Actual (b) Calculated Average Conc. Conc. Conc. Sample No. Test No. µg/ml (ppm) µg/ml (ppm) µg/ml (ppm) 50-100 100 100-250 250 250-500 500 (75) (175) (375) Experiment 1 22 19 78.75 68.8 A,B,D 23 18 78.75 65.6 A D 24 7 78.75 100 78.1 A,C,D B 25 33 105 93.8 A B,C,D 26 12 105 93.8 A B,C,D 27 38 105 93.8 93.8 A B,C,D 28 31 210 193.8 A,B,D C 29 25 210 293.8 A B,D 30 11 210 231.2 239.6 A B,C,D 31 28 262.5 387.5 A D B,C 32 4 262.5 312.5 B,D A,C 33 32 262.5 375 358.3 B A,D C 34 30 420 437.5 A,D B,C 35 3 420 437.5 A,D B,C 36 8 420 468.8 447.9 A B,C,D (a) The nitrate concentration (µg/ml) (ppm) was estimated y comparison of the test strip color with the reference color chart. (b) Determined by ion chromatography (c) Each test strip (one strip per water sample) was independently read by four evaluators (A,B,C,D) as indicated. MS310-7

DOE Methods Table 1. (contd) Nitrate Concentration (a) Actual (b) Calculated Average Conc. Conc. Conc. Sample No. Test No. µg/ml (ppm) µg/ml (ppm) µg/ml (ppm) 0 0-10 10 10-25 25 25-50 50 Experiment 2 (5) (17.5) (37.5) 1 8 0 0 A,B,C,D 2 2 0 0 0 A,B,C,D 3 7 10.5 8.8 D A,B,C 4 12 10.5 6.2 7.5 A,B,D C 5 4 52.5 45 D C B 6 3 52.5 32.5 38.8 D C B A 7 6 105 131.2 8 11 105 84.4 107.8 D Nitrate Concentration (a) Actual (b) Calculated Average Conc. Conc. Conc. Sample No. Test No. µg/ml (ppm) µg/ml (ppm) µg/ml (ppm) 50-100 100 100-250 250 250-500 500 Experiment 2 (75) (175) (375) 5 4 52.5 45 A 6 3 52.5 32.5 38.8 7 6 105 131.2 D C A,B 8 11 105 84.4 107.8 A,B,C 9 1 262.5 325 D A.B.C 10 5 262.5 406.2 365.6 A,C,D B (a) The nitrate concentration (µg/ml) (ppm) was estimated by comparison of the test strip color with the reference color chart. (b) Determined by ion chromatography (c) Each test strip (one strip per water sample) was independently read by four evaluators (A,B,C,D) as indicated. MS310-8

Field 500 Strip Test Assay (µg/ml) (ppm) 400 300 200 100 0 0 100 200 300 400 500 Ion Chromatography (ppm) IC Strip Test Figure 1. Strip-Test Assay for Nitrate in Spiked Water. Strip test versus ion chromatography. MS310-9

DOE Methods Table 2. Strip Test Assay for Nitrate in Contaminated Water Nitrate Concentration (a) Actual (b) Calculated Average Conc. Conc. Conc. Sample No. Sample ID Test No. µg/ml (ppm) µg/ml (ppm) µg/ml (ppm) 0 0-10 250-500 500 (5) (17.5) (37.5) 1 SGW36 36 0 A,B,C,D,E (c) 2 SGW 4 0 A,B,C,D,E 3 SGW 21 0 0 A,B,C,D,E 4 125 10 2835 0 A B,C,D,E 5 125 14 2835 475 A B,C,D,E 6 125 33 2835 475 475 7 126 3 3082 500 A,B,C,D,E 8 126 15 3082 450 A,D B,C,E 9 126 24 3082 475 475 A B,C,D,E 10 127 18 3545 450 A,D B,C,E 11 127 30 3545 450 A,C B,D,E 12 127 13 3545 475 458 A B,C,D,E 13 128 1 2722 475 A B,C,D,E 14 128 23 2722 475 A B,C,D,E 15 128 9 2722 475 475 A B,C,D,E 16 129 17 2738 475 A B,C,D,E 17 129 29 2738 475 A B,C,D,E 18 129 12 2738 425 458 A,C,D B,E 28 133 19 2.24 0 A,B,C,D,E 29 133 5 2.24 0 A,B,C,D,E 30 133 16 2.24 0 0 A,B,C,D,E 42 SGW 42 0 0 0 A,B,C,D,E (a) The nitrate concentration (µg/ml) (ppm) was estimated by comparison of the test strip color with the reference color chart. (b) Determined by ion chromatography (c) Each test strip (one strip per water sample) was independently read by four evaluators (A,B,C,D) as indicated. MS310-10

Field Table 2. (contd) Nitrate Concentration (a) Actual (b) Calculated Average Conc. Conc. Conc. Sample No. Sample ID Test No. µg/ml (ppm) µg/ml (ppm) µg/ml (ppm) 25-50 50 50-100 100 100-250 250 250-500 500 (37.5) (7.5) (175) (375) 19 130 11 179.4 185 A D,E B,C 20 130 7 179.4 170 C,D,E B 21 130 2 179.4 190 179 A,C,D,E B 22 131 28 350.9 335 A C,D,E B 23 plus sed(d) 6 350.9 360 A C,D,E B 24 okys sed(d) 8 350.9 335 343 A C D,E B 25 132 31 456.9 360 A C,D,E B 26 132 26 456.9 385 A C,E B,D 27 132 35 456.9 385 379 A C,D B,E 31 134 22 142 155 A D C,E B 32 134 25 142 140 A D B,C,E 33 134 34 142 140 145 A D B,C,E 34 131 27 350.9 340 A C,D,E B 35 minus sed(4) 32 350.9 360 A C,D,E B 36 minus sed(d) 20 350.9 375 358 A,B,C,D,E 37 125 dil1:10 37 141.7 140 140 E D A,B,C 38 minus sed(4) 38 154.1 175 175 D A,C,E B 39 127 dil 1:10 39 177.2 190 190 A,C,D,E B 40 128 dil 1:10 40 136.1 125 125 E A,D B,C 41 129 dil 1:10 41 136.9 160 160 A,D C,E B (a) The nitrate concentration (µg/ml) (ppm) was estimated by comparison of the test strip color with the reference color chart. (b) Determined by ion chromatography (c) Each test strip (one strip per water sample) was independently read by four evaluators (A,B,C,D) as indicated. MS310-11

DOE Methods 500 Strip Test Assay (µg/ml) (ppm) 400 300 200 100 0 0 100 200 300 400 500 Ion Chromatography (µg/ml) (ppm) IC Strip Test Figure 2. Strip-Test Assay for Nitrate in Contaminated Water. Strip test versus ion chromatography. MS310-12