VITA ENAMIC The Concept

Similar documents
VITABLOCS Product information

VITA ENAMIC Expert opinions on hybrid ceramics

VITAVM 9 VENEERING MATERIAL. Working Instructions

VITA Easyshade V Optimum shade determination, maximum reliability

VITA CAD/CAM MATERIALS VITA CAD/CAM MATERIALS. Quick Guide for Practices and Laboratories. For best solutions. Proven a million times over.

VITA PROSTHETIC SOLUTIONS Mould Chart

VITA INTERNO. For natural, in-depth colour effects. VITA perfect match. Date of issue: 09.17

VITA VMK Master. Masterful in all cases. VITA shade, VITA made. VITA shade control. VITA shade reproduction. Date of issue 06.16

VITA ADIVA LUTING SOLUTIONS The Concept

VITA ENAMIC. Implant-supported crowns. Working Instructions. VITA shade, VITA made. VITA shade control. VITA shade reproduction. Date of issue: 07.

REINFORCED COMPOSITE BLOC FOR PERMANENT RESTORATION. BRILLIANT Crios. High performance made brilliant

VITA ENAMIC Technical and scientific documentation

Empress * CAD IPS. Confidence. Reliability. Esthetics. IPS Empress CAD for the CAD/CAM Technology Information for Dentists

BLOCK RANGE CAD. IPS e.max

Leading material offering and application range. Straumann CARES CADCAM

SHOFU BLOCK & DISK CAD/CAM CERAMIC-BASED RESTORATIVE. Visit or call mm x 12mm x 16mm. 98mm x 14mm. 12mm x 14mm x 18mm

IPS Empress System Information for the. Laboratory. Confidence. Reliability. Esthetics. Empress IPS. System. The ultimate esthetic restorative system

Implant-supported crowns Working Instructions

Ceramic Based Aesthetic CAD/CAM Restorative

Empress *CAD. Confidence. Reliability. Esthetics. IPS Empress CAD for the CAD/CAM Technology Information for Dentists

CERASMART for PlanMill

SHOFU BLOCK & DISK CAD/CAM CERAMIC-BASED RESTORATIVE. Visit or call mm x 14mm

BLOCK RANGE CAD. IPS e.max

VITA ENAMIC Technical and scientific documentation

I N F O R M A T I O N F O R D E N T I S T S. IPS e.max one system for every indication

Empress *CAD IPS. Confidence. Reliability. Aesthetics. The world s leading all-ceramic

VITAPAN EXCELL Perfect shape. Shade accuracy. Light dynamics.

Lithium Disilicate. Zirconia

VITA ENAMIC Implant Solutions Clinically Proven Force Absorption for Prosthetic and Implant Success

VITA VMK Master Quickstart Instructions

Dental technician. CAD The original lithium disilicate CAD/CAM glass-ceramic. All ceramic, all you need.

all ceramic all you need

Press Impulse. In pursuit of nature. all ceramic all you need

My Lava Ultimate. Chairside Crown. Lava Ultimate CAD/CAM Restorative for CEREC. Precision Solutions

VITA MFT Easy to set up, reliable in function and esthetics

CAD/CAM NEEDS. IPS e.max CAD THE LEADING CAD/CAM LITHIUM DISILICATE ceramic. all ceramic all you need

VITAVM 9 Quickstart Working Instructions

LRF LEUCITE-REINFORCED FELDSPAR CAD/CAM BLOCK

VITABLOCS RealLife for CEREC / inlab MC XL Working Instructions

SpeedCEM Plus. The self-adhesive resin cement A BIG PLUS FOR ZIRCONIA. Ideal for. ZirCAD

the new dna of high strength glass ceramics

Real fast. Real tough. Real easy. Psst it s the one on the left. Lava Ultimate. CAD/CAM Restorative

CERASMART. The new leader in hybrid ceramic blocks

Developed to make a difference

Precision Solutions. Lava Ultimate Implant Crown Restorative. My favourite crown. over implants

SPECIALIST IN CUSTOMIZED PROSTHETICS

new Variolink Esthetic The esthetic luting composite Amazingly simple esthetics!

VITA Akzent stands for a concept which replaces the previous generation of stains and thus enables the dental technician to achieve even more natural

Working Instructions. Date of issue: Composite blocks made from acrylate polymer for the fabrication of long-term temporary restorations

STRONGEST IN ITS CLASS

the new dna of high strength glass ceramics

blocs Grandio blocs nano-hybrid composite cad / cam block

VITA ENAMIC for CEREC / inlab Working Instructions

10mm x 12mm x 16mm. 98mm x 14mm SHOFU BLOCK & DISK CAD/CAM CERAMIC-BASED RESTORATIVE. 12mm x 14mm x 18mm. Visit or call

IPS Ivocolor Universal stains and glazes

Grandio blocs / Grandio disc STRONGEST IN ITS STRONGEST IN ITS 86% FILLED NANO-CERAMIC HYBRID CAD/CAM MATERIAL

VITA ENAMIC. The ceramic of the future? The new hybrid ceramic everyone is talking about. 10 Facts & Features

THE CLINICALLY PROVEN SOLUTION FOR ALL YOUR CAD/CAM NEEDS. IPS e.max CAD THE LEADING CAD/CAM LITHIUM DISILICATE CERAMIC. all ceramic all you need

NEW IPS Ivocolor. Universal stains and glazes

NEW. SpeedCEM. Plus. The self-adhesive resin cement A BIG PLUS FOR ZIRCONIA

Competence in. All-Ceramics

Working Instructions. Vita System. 3D - Master. VITA shade taking VITA shade communication VITA shade reproduction VITA shade control

VITA AKZENT. for natural surface colour effects. VITA shade, VITA made.

VITABLOCS Mark II for KaVo Everest Working Instructions. Always on the safe side

Nexco. Lifelike appearance. made easy. The light-curing lab composite

M-PM DISC DIGITAL PRECISION BRILLIANT AESTHETIC

CERAMAGE UP. Indirect Flowable with Revolutionary Handling Characteristics. Visit or call

VITA shade determination

A Formula for Success. Lava All Zirconia. The flexibility you need. 3M All Rights Reserved.

Natural beauty restored.

IPS. Empress Esthetic. NEWS from the IPS Empress Original System

Variolink Esthetic The esthetic luting composite SIMPLE ESTHETICS! Recommended for. CAD/Press. Recommended for. Tetric CAD

Tizian Blank. Tizian Zirconia Reinforced Composite

G-CEM LinkForce. Made to fit. Designed to last. from GC. all your adhesive challenges. Dual-cure adhesive luting cement

BEGO PMMA Multicolor Processing information for CAD/CAM-produced restorations

Grandio blocs Grandio disc. blocs disc

A lasting connection: Esthetic implantborne single-tooth restorations. Part 1

Straumann n!ce Turn time spent milling into time spent smiling. Quick Guide

Viteo. Base THE TITANIUM BASE FROM THE MATERIALS SPECIALISTS THE BASE FOR SUCCESS

Dentist THE POPULAR AND RELIABLE ALL-CERAMIC SYSTEM

Multilink Automix The adhesive cementation system

Natural beauty restored.

Developed to make a difference... every step of the way. CEREC CAD/CAM solutions

MODERN CAD/CAM COMPOSITE MATERIALS: MATERIAL PROPERTIES AND LUTING STRATEGIES

Multilink Automix The adhesive cementation system

It s more than a denture, It s a smile. IVOCLAR VIVADENT REMOVABLE. More than dentures. Tooth Line Portfolio

Optra. Innovative accessories for. simplified treatment procedures. Innovative Accessories

Spring / Summer CLINICAL. SPECIAL OFFERS / 1 st MARCH - 31 st AUGUST

VITA ENAMIC Technical and scientific documentation

Telio. Everything (for) provisionals. Telio CAD. Telio LAB. Telio CS

VITA ENAMIC Technical and scientific documentation

TECHNICAL GUIDE. For use with CEREC

creamed I HAVE THE CHOICE AMBARINO High Class High-Performance Material enthusiastic in functionality and aesthetics.

Product Information. Translucent Zirconium Dioxide For monolithic restorations. Giving a hand to oral health.

Keep. simple. 3M RelyX Cements

Practicing Minimally Invasive Dentistry with Durability and Esthetic in Mind

Lava All-Zirconia. What about chipping? Not an issue for us. All-Zirconia Monolithic Restoration

DISCOVER MORE. Materials Choose the ideal veneering material for your digitally produced frameworks and restorations:

VITA Akzent. for natural surface colour effects. Date of issue: T e e t h V e n e e r i n g M a t e r i a ls. S e r v ic e

Direct composite restorations for large posterior cavities extended range of applications for high-performance materials

Transcription:

VITA ENAMIC The Concept En VITA shade determination VITA shade communication VITA shade reproduction VITA shade control Date of issue: 02. 15 VITA shade, VITA made. The En formula for success: strength + elasticity = reliability²

MILESTONES OF DENTAL CAD/CAM MATERIALS 2007: CAD/CAM composites CAD/CAM composite materials are used 2005: Lithium disilicate for CAD/CAM Practical use of lithium disilicate begins 1985: Feldspar ceramic First clinical use of VITABLOCS made of feldspar ceramic

2013: VITA ENAMIC With VITA ENAMIC, the first dental hybrid ceramic for CAD/CAM restorations in the world, is introduced + = Ceramic network polymer network hybrid ceramic En "Hybrid ceramic provides a new definition of load capacity" * VITA ENAMIC is the first hybrid dental ceramic in the world with a dual-network structure. In this dental material, the dominant ceramic network is strengthened by a polymer network, with both networks fully integrated with one another. VITA ENAMIC is a dental hybrid material that combines the positive characteristics of a ceramic and a composite. In addition to a high degree of elasticity, this innovative hybrid ceramic guarantees particularly high load capacity after adhesive bonding. As a result, this material is perfectly suited for posterior crown restorations and also enables the reduction of wall thicknesses for minimally-invasive restorations. The superior reliability of VITA ENAMIC, as well as its precision, edge stability and corresponding milling accuracy are also excellent features. Finally, this toothcolored hybrid material offers material properties that are almost identical to those of natural teeth, ensuring a natural play of colors thanks to its excellent light conductivity. The En formula for success: strength + elasticity = reliability² *) In addition to a high degree of elasticity, this innovative hybrid ceramic guarantees particularly high load capacity after adhesive bonding.

VITA ENAMIC Hybrid ceramic: Advantages for you VITA ENAMIC overview of the benefits Enormous load capacity After bonding to the remaining tooth substance, VITA ENAMIC exhibits enormous load capacity and guarantees perfect distribution of masticatory forces. The polymer network offers outstanding absorption of intraoral load. As a result, this material is suited especially for posterior crown restorations. Crack-stop Excellent reliability VITA ENAMIC is a very reliable material, and, as a hybrid ceramic, offers an integrated crack stop function thanks to its special dual-network structure. Restorations that are gentle on oral substance In addition to greater strength, VITA ENAMIC also guarantees the necessary elasticity, enabling minimally invasive treatment so that healthy tooth substance can be retained by reducing the wall thickness. Precise and accurate restorations Following the milling process, the VITA ENAMIC hybrid ceramic shows excellent edge stability particularly in the case of thin restoration margins and allows accurate morphology as well as an end result that offers a perfect fit. Fast and efficient fabrication The excellent milling properties of VITA ENAMIC guarantee that restorations can be fabricated more quickly and wear and tear on milling tools can be minimized. The hybrid ceramic is also already at full strength and can be inserted immediately after milling. Natural results that match the tooth shade VITA ENAMIC is a tooth-colored dental material that offers superb light conductivity. As a result, VITA ENAMIC restorations blend in perfectly with the remaining tooth substance, enabling a natural play of colors.

VITA ENAMIC Indications and shades Range of indications In addition to classic single tooth restorations (inlays, onlays, veneers and crowns), VITA ENAMIC is particularly suitable for minimally invasive restorations and crown restorations exposed to high masticatory forces (molar area). Indication Implant-supported crowns* VITA ENAMIC crowns Onlays/Inlays Veneers recommended by VITA * The abutments must be designed in a way to meet the requirements for ceramic-specific preparation and to observe the minimum wall thicknesses of crowns made of VITA ENAMIC. Please observe the processing instructions of the manufacturer of the implant and the adhesive bonding material. More information: Working instructions - VITA ENAMIC implant-supported crowns, Prod. No. 10077. Esthetic results in two translucency levels Shades: VITA ENAMIC is available in two levels of translucency, HT (HT = highly translucent) and T (T = translucent), as well as in the six VITA SYSTEM 3D-MASTER shades 0M1, 1M1, 1M2, 2M2, 3M2 and 4M2. Primary indication - high translucent (HT): inlays/onlays, veneers, partial and full crowns Primary indication - translucent (T): masking discolored dies, in particular for crowns 0M1 1M1 1M2 2M2 3M2 4M2 HT T

VITA ENAMIC STAINS KIT Natural play of colors in a very simple manner The VITA ENAMIC Stains Kit comprises six stains and accessories for the reproduction of natural shade nuances of restorations made of hybrid ceramic. The stains are bonded to the restoration as part of a polymerization process. Surface sealing can be performed using the chemical glaze material VITA ENAMIC GLAZE, which increases the durability and brilliance of the shade in the oral environment. Processing is based on a simple 5-step principle: condition the surface, mix and apply the shades, carry out intermediate polymerization, apply chemical glaze material and perform final polymerization. Benefits Fast processing: Simply apply the VITA ENAMIC stains to the restoration, polymerize and that's it! With this process, the shade of VITA ENAMIC restorations can be quickly characterized. High level of individuality: The anomalies and shade nuances of natural teeth can be individually reproduced with the six VITA ENAMIC stains. Simple processing: The shade intensity of the VITA ENAMIC stains can be perfectly controlled by the ratio of liquid to shade powder. As a result, the good flow characteristics ensure precise application of the stains.

VITA ENAMIC Polishing Set (clinical / technical) All instruments to achieve excellent results The VITA ENAMIC sets of polishing instruments were developed for reliable, effi cient and material-specific surface treatment of hybrid ceramic restorations in dental practices and laboratories. The sets include various polishing instruments for pre- and high-gloss polishing. These instruments are suitable for careful and gentle polishing of occlusal surfaces, cusps, fissures and restoration contact points. The use of these polishing instruments results in surfaces with exceptional gloss. Benefits Excellent final results: Excellent and plaque-resistant surfaces are produced with these instruments. Precise concentricity, matched grit sizes and the individual geometries of the instruments guarantee results with superior precision. Simple and safe handling: The instruments guarantee superior material removal performance. Good handling and the ability to use without polishing paste enables simple and fast processing. Safe use of the clinical instruments is guaranteed since they can be sterilized. Gentle and careful processing: These instruments, which were developed especially for VITA ENAMIC, ensure gentle and careful reworking. As a result, the risk of possible formation of microcracks is reduced.

VITA ENAMIC Findings of materials science Technical and scientific documentation of the hybrid ceramic The hybrid ceramic is comprised of a porous ceramic matrix with the pores being fi lled with a polymer material. The mass percentage of the inorganic ceramic part is approx. 86 wt%, while the mass percentage of the organic polymer part is 14 wt%. The advantages that distinguish VITA ENAMIC from others are based on its unique properties. The high load capacity, exceptional reliability and quality of the very natural restorative material, as well as high precision and economic efficiency are documented on the basis of the technical and material-scientific results. Short overview of physical/mechanical properties of VITA ENAMIC VITA ENAMIC Static fracture load [N] (S 2766 (98) Flexural strength [MPa] 150 160 Modulus of elasticity [GPa] (SD) 30 (2) Abrasion [µm] In the same range as VITABLOCS Mark II, veneering ceramics Weibull modulus 20 Hardness [GPa] 2.5 Shade stability Excellent, E < 2 Machinability, edge stability Excellent Milling times, fast milling mode MC XL Inlay: 4:40 min Anterior crown: 4:19 Posterior crown: 5:13 min Milling tool service life: posterior crowns Normal: 148 Fast: 132

Unsurpassed load capacity even for thin walls Fracture load [N] Static fracture load 3500 3000 2500 2000 1500 1000 500 0 VITA ENAMIC IPS e.max Lava IPS Empress CAD HT Ultimate CAD Source: Boston University, Prof. Dr. Giordano Biogeneric, fully anatomical crowns from the respective materials were milled using the Sirona MC XL milling system and then polished / crystallized. Cemented to standardized, prefabricated and filled resin dies using Multilink Automix. Immersed at room temperature in water for 24 hours. In a testing machine, static load was applied to the crowns until fracturing occurred. Summary: In this test setup, VITA ENAMIC demonstrates the highest fracture load of approx. 2766 newtons and the lowest standard deviation. Dynamic fracture load Survival rate [%] 100 90 80 70 60 50 40 30 20 10 0 VITA ENAMIC (normal wall thickness) Source: University of Freiburg, Dr. Güß Enamic (minimal wall thickness) Following etching, 14 VITA ENAMIC crowns were cemented to composite dies using Variolink II. The crowns were embedded in Technovit 4000 (Heraeus Kulzer) and immersed in warm water (37 C) for 24 hours. Exposed to a cyclic load in the chewing simulator: 198 N for 1.2 million cycles at a frequency of 1.6 Hz, with 3 mm steatite beads as the antagonist, TC 5 55 C. Following the dynamic tests, static load was applied to the crowns until fracture occurred. Summary: The survival rate of VITA ENAMIC crowns with walls of normal and reduced thickness is 100%.

VITA ENAMIC Findings of materials science Utmost reliability and integrated crack-stop function Weibull modulus [m] 25 20 15 10 5 0 Source: Internal study, VITA R&D VITA ENAMIC IPS Empress IPS e.max Lava CAD CAD LT Ultimate The Weibull modulus describes the reliability of a material in a way that cannot be explained based solely on flexural strength. The Weibull modulus was determined based on the flexural strength of 30 bending bars. Summary: Of the materials examined in this test, VITA ENAMIC offered the highest reliability. The Weibull modulus is 20. When evaluating the Weibull modulus, the flexural strength (in-house measurements of VITA R&D: VITA ENAMIC: 153.82 MPA (SD 7.56 MPa), Lava Ultimate: 188.42 MPa (SD 22.29 MPa), IPS Empress CAD: 157.82 MPa (SD 17.33 MPa), IPS e.max CAD LT: 344.05 MPa (SD 64.5 MPa)) should always also be taken into account. In the Vickers test, an indentation in a polished surface is made using a pyramidal tip to determine the hardness of the material. Magnification Summary: In this test, ceramics exhibit a clearly limited indentation with sharp edges defined by crack formation and mostly straight-running cracks at the margins. However, for VITA ENAMIC, the dual network structure results in an indentation that is not limited at the margins - a smooth transition is found. Cracks that are typical for ceramics generally occur in the corners of the indentations, but they run only through the ceramic substructure and are always stopped by the polymer network. Magnification Source: Internal study, VITA R&D

Modulus of elasticity and abrasion behavior Modulus of elasticity [GPa] IPS e.max CAD LT IPS Empress CAD VITABLOCS Mark II VITA ENAMIC Lava Ultimate CAD-Temp Source: Internal study, VITA R&D 0 10 20 30 40 50 60 70 80 elastic Dentin Modulus of elasticity [GPa] rigid The modulus of elasticity was determined based on the stress strain curves of the measurements of flexural strength. Summary: With an elasticity of 30 GPa, VITA ENAMIC is in the same range as human dentin. Up until now, no dental restorative material was in this elastic range. Note: There are big differences concerning the modulus of elasticity of human dentin in literature. Sources: Kinney JH, Marshall SJ, Marshall GW. The mechanical properties of human dentin: a critical review and re-evaluation of the dental literature. Critical Reviews in Oral Biology & Medicine 2003; 14:13-29 Enamel - enamel-like abrasion behavior Dentin comparable flexibility (modulus of elasticity) Pulp Abrasion [µm] 80 70 60 50 40 30 20 10 0 VITA ENAMIC VITABLOCS Mark II Material abrasion Antagonist abrasion Source: University of Zurich, Prof. Mörmann Enamel In chewing simulator (Zurich),1.2 million cycles, 1.7 Hz, load: 49 N, 6000 thermocycles. Natural enamel as antagonist. Summary: The abrasion level of VITA ENAMIC is 49 µm. The level of abrasion to the antagonist enamel caused by VITA ENAMIC is 30.2 µm. VITABLOCS Mark II causes a slightly higher level of abrasion to the antagonist of 38.1 µm. As a control group, the abrasion of enamel to enamel was measured in the study. The goal with VITA ENAMIC was to further improve on the antagonist-friendly properties of VITABLOCS Mark II without abandoning the ceramic behavior of the material.

VITA ENAMIC Findings of materials science Machinability and edge stability VITA ENAMIC, 30 wedge, lateral view (left photo); VITA ENAMIC, 30 wedge, top view, 200 x magnifi cation (photo in the middle); IPS e.max CAD, 30 wedge, top view, 200 x magnification, (right photo): source: VITA R&D Using the Sirona MC XL milling system, 30 wedges were milled from various materials in normal milling mode. Summary: VITA ENAMIC exhibits high edge stability in areas with thin margins. VITA ENAMIC IPS Empress CAD IPS e.max CAD Using the Sirona MC XL milling system, non-prep veneers were milled in normal milling mode from various materials with a wall thickness of approx. 0.2 mm. The manufacturer has not approved the use of IPS Empress CAD and IPS e.max CAD for a wall thickness of approx. 0.2 mm. Summary: The perfect edge stability of VITA ENAMIC is demonstrated by the non-prep veneers. The geometry in this case with a wall thickness of approx. 0.2 mm could only be fully milled using VITA ENAMIC.

Service life of milling tools and milling times Number of crowns Number of milled molar crowns 160 140 120 100 80 60 40 20 Using the Sirona MC XL milling system, one pair of milling tools in each case was used to grind as many molar crowns as possible from a variety of CAD/CAM materials in normal milling mode and in fast milling mode. The lives of the milling tools indicate the results of a series of measurements. 0 Normal milling Fast milling VITA ENAMIC Source: Internal study, VITA R&D IPS e.max CAD Summary: VITA ENAMIC enables more efficient milling than comparable materials. The milling time for VITA ENAMIC restorations is by far the shortest and also ensures a long milling tool service life of approx. 148 / 132 milled crowns for each set of milling tools. VITA ENAMIC VITABLOCS Mark II Normal Fast Normal Fast 7:56 7:10 9:07 4:40 4:19 5:13 10:27 10:35 13:29 6:24 7:03 9:26 The milling tests were performed using the Sirona MC XL milling system. The block selection of the corresponding material was selected and five restorations of each material were milled. The milling times were taken from the log files. The times correspond to the average value determined on the basis of five measurements. IPS e.max CAD Lava Ultimate Normal Fast Normal Fast 12:17 12:36 14:58 10:00 08:11 12:14 10:39 10:10 11:55 7:27 6:27 8:24 Summary: Compared to VITABLOCS Mark II, Lava Ultimate and IPS e.max CAD, VITA ENAMIC restorations can be milled more quickly.

VITA ENAMIC Accessories VITA ENAMIC The first hybrid dental ceramic in the world with a dual network structure creates a new definition of load capacity. VITA ENAMIC is the dental material of the future, enabling fast and efficient processing and produces perfect results for users and patients alike. Enormous load capacity achieved by combining elasticity and stability Unsurpassed reliability thanks to an integrated dual network structure with crack-stop function Effi cient processing thanks to long service life of milling tools and short milling times Precise and accurate restorations also in cases of thin walls Excellent translucency results in natural restorations that match the tooth shade VITA ENAMIC POLISHING SET The VITA ENAMIC sets of polishing instruments were developed for reliable, effi cient and material-specific surface treatment of hybrid ceramic restorations in dental practices and laboratories. The sets include various polishing instruments for pre- and high-gloss polishing. Precise concentricity, matched grit sizes and the individual geometries of the instruments guarantee results with superior precision. Good handling and the ability to use without polishing paste enables simple and fast processing. These instruments, which were developed especially for VITA ENAMIC, ensure gentle and careful reworking. As a result, for example, the risk of possible formation of microcracks is reduced. VITA ENAMIC STAINS KIT The VITA ENAMIC STAINS KIT includes six stains and accessories for the reproduction of natural shade nuances of restorations made of hybrid ceramic. The stains are bonded to the restoration as part of a polymerization process. Surface sealing can be performed using the chemical glaze material VITA ENAMIC GLAZE, Simply apply the VITA ENAMIC stains to the restoration, polymerize and that's it! With this process, the shade of VITA ENAMIC restorations can be quickly characterized. The shade nuances and anomalies of natural teeth can be individually reproduced with the six VITA ENAMIC stains. The shade intensity of the VITA ENAMIC stains can be perfectly controlled by the ratio of liquid to shade powder. As a result, homogeneous and smooth application of shades is ensured.

VITA ENAMIC Clinical studies In-vivo studies a) Clinical study, University of Freiburg, PD Dr. Güß: VITA ENAMIC crowns Start of the study: November 2011 Number of restorations fitted: 71 b) Clinical study, University of Freiburg, PD Dr. Güß: VITA ENAMIC inlays, onlays, partial crowns, table tops Start of the study: November 2011 Number of restorations fitted: 100 c) Acceptance phase: VITA ENAMIC crowns, implant crowns, partial crowns, inlays, onlays, veneers; approx. 594 restorations (as of December 2012) were inserted by various pilot users

With the unique VITA SYSTEM 3D-MASTER, all natural tooth shades can be systematically determined and perfectly reproduced. Please note: Our products must be used in accordance with the instructions for use. We accept no liability for any damage resulting from incorrect handling or usage. The user is furthermore obliged to check the product before use with regard to its suitability for the intended area of application. We cannot accept any liability if the product is used in conjunction with materials and equipment from other manufacturers that are not compatible or not authorized for use with our product. Furthermore, our liability for the accuracy of this information is independent of the legal basis and, in as far as legally permissible, shall always be limited to the value as invoiced of the goods supplied, excluding value-added tax. In particular, as far as legally permissible, we do not assume any liability for loss of earnings, indirect damages, ensuing damages or for third-party claims against the purchaser. Claims for damages based on fault liability (culpa in contrahendo, breach of contract, unlawful acts, etc.) can only be made in the case of intent or gross negligence. The VITA Modulbox is not necessarily a component of the product. Date of issue of this information: 02.15 After the publication of these information for use any previous versions become obsolete. The current version can be found at www.vita-zahnfabrik.com VITA Zahnfabrik has been certified in accordance to the Medical Device Directive and the following products bear the CE mark : VITA ENAMIC CEREC and inlab are registered trademarks of Sirona Dental GmbH, Wals, Austria. IPS Empress CAD, IPS e.max CAD and Multilink Automix are registered trademarks of Ivoclar Vivadent AG, Schaan, Liechtenstein. Lava Ultimate is a registered trademark of 3M Company or 3M Deutschland GmbH. 10024E - 0215 (X.) S - Version (04) VITA Zahnfabrik H. Rauter GmbH & Co.KG Spitalgasse 3 D-79713 Bad Säckingen Germany Tel. +49(0)7761/562-0 Fax +49(0)7761/562-299 Hotline: Tel. +49(0)7761/562-222 Fax +49(0)7761/562-446 www.vita-zahnfabrik.com info@vita-zahnfabrik.com facebook.com/vita.zahnfabrik