Abstract. Infection control in health care

Similar documents
Syllabus for International Dental Assistants. Prepare and maintain the dental surgery, instruments, and equipment for clinical dental procedures

PRINCIPLES AND PRACTICES OF ASEPSIS OBJECTIVES

3/26/2014 OBJECTIVES PRINCIPLES AND PRACTICES OF ASEPSIS DEFINING ASEPSIS MEDICAL ASEPSIS PRINCIPLES OF MEDICAL ASEPSIS

Infection Control. Dr. Kannan Rengasamy School of Dental Medicine University of Connecticut. ADAA guide module VIII

Scope This policy applies to all personnel and departments that clean, prepare and/or sterilize items intended for patient care use.

Radiographic Policy *ALL RADIOGRAPHS ARE TAKEN FOR DIAGNOSTIC PURPOSES ONLY

CDR Positioning System User Guide

Analysis of photostimulable phosphor plate image artifacts in an oral and maxillofacial radiology department

AMENDATORY SECTION (Amending WSR , filed 10/10/95, effective 11/10/95)

SUBJECT: Management of Human Body Fluids/Waste (Bloodborne Pathogens)

Policy Title: Single-Use (Disposable) Devices Policy Number: 13. Effective Date: 6/10/2013 Review Date: 6/10/2016

Bloodborne Pathogen Annual Training

AMENDATORY SECTION (Amending WSR , filed 10/10/95, effective. WAC Purpose. The purpose of WAC through

ACHIEVING CROSS INFECTION CONTROL

EXPERIMENT. Food Safety

STANDARD FOR PORCINE SEMEN QUALITY IN AI CENTRES

Appendix C. RECOMMENDATIONS FOR INFECTION CONTROL IN THE HEALTHCARE SETTING

How Do You Know If a Sterilized Package Remains Sterile?

Prepare and maintain environment, instruments, and equipment for clinical dental procedures

Best Practice Guidance 12_Version 1.2. Title: Collection of Biological Samples

Current Concepts in Caries Management Diagnostic, Treatment and Ethical/Medico-Legal Considerations. Radiographic Caries Diagnosis

CHAPTER 7 Medical/Surgical Asepsis and Infection Control

Central Community College

I n t r a o r a l S k i l l s I ( 1 2 A )

(e)dental Evaluation & Consultation Service Comments on Digital Dental Sensors, Oct 2010

Old Dominion University Norfolk, VA DENTAL HYGIENE PROGRAM CANDIDATED INFORMATION FOR THE CITA ADMINISTERED ADEX HYGIENE EXAMINATION

INSTRUCTIONS FOR USE AND CARE

COURSE: Dental Radiography

Dental Hygiene Spring 2018 Summer 2014 Fall COURSE OUTLINE DHT 1032 Dental Radiography 2 Credit Hours

Altus Product description / Instructions for Use IFU 6 Rev. 1

Sterilization and proper use of Autoclaves

How Do You Know If Your Sterilized Instruments Remain Sterile?

Film processing procedures have a direct effect on the quality of a radiograph.

EXPERIMENT. Fomite Transmission. Hands-On Labs, Inc. Version

Policy Title: Clinical Asepsis Policy Policy Number :19. Effective Date: 6/10/2013 Review Date: 6/10/2016

Dental Radiography

APPLIED EDUCATIONAL SYSTEMS. Infection Control. Health Science and Technology Education. Table of Contents

A MODIFIED DIP-SLIDE TEST FOR MICROBIOLOGICAL RISK IN CARIES ASSESSMENT

STERILITY TESTING OF PHARMACEUTICAL PRODUCTS

Assessing the Risk of Laboratory Acquired Allergies

Dental Radiography Core Subject. Digital Radiography

The term Routine Practices is used to describe practices that were previously known as Universal Precautions.

Joint Commission In Dental Settings

San Joaquin Valley College - Visalia

EXPERIMENT. Bacteria Identification through Functional Media Motility Testing

Sterilization Protocols-2015

Bloodborne Pathogens. General

Chapter 12. Preventing Infection. Elsevier items and derived items 2014, 2010 by Mosby, an imprint of Elsevier Inc. All rights reserved.

At the end of this session, the participants will be able to:

Entry Level Assessment Blueprint Dental Assisting

Media Fill Test Kits. Manufactured by. Making USP <797> compliance easy!

THIS IS UNFPA. Male Latex Condom Testing Guidance UNICEF UNFPA WHO Joint Meeting September David Hill

Title: Supplementary guidelines on handling of

Chapter 11 PREVENTING INFECTION. Elsevier items and derived items 2010 by Mosby, Inc. an affiliate of Elsevier Inc. All rights reserved

Infection Control Update

Chapter 13. Preventing Infection. Copyright 2019 by Elsevier, Inc. All rights reserved.

EXPERIMENT. Bacteria Identification through Functional Media Motility Testing

Pediatric Settings and Daycare Facility Cleaning and Disinfection Protocol For Cryptosporidium

Effective Use of Surface Disinfectants. Infection prevention guidelines and recommended protocols can be confusing, especially regarding the

CHEROKEE COUNTY SCHOOL DISTRICT

SCOTTISH AMBULANCE SERVICE Strategic Co-ordination Centre (SCC) Bulletin 01/ April Swine Flu-Information Sheet

Chapter 7 8/23/2016. Asepsis and Infection Control. Asepsis. Asepsis (Cont.) Microorganisms. Infection control and prevention

INFECTION CONTROL IN PRACTICE. Continuing Education

MAKE SMART INJECTION CHOICES INJECTION PROVIDERS GUIDE FOR SAFE INJECTIONS

Evidence-based decision-making in endodontics

Bloodborne Pathogens in the Workplace

Manufacturer s information

Site Information for WREB Examinations June 14-18, School Coordinator Colleen Stephenson (208)

According to the Centers

Environmental Infection Control General Directorate for Infection Prevention and Control Section: Dental

Common Intra Oral Radiographic Errors Made by Dental Students

Yasargil Permanent Aneurysm Clips

Standard Operating Procedures for Infection Control. Dental Hygiene Operatory Preparation and Clean-up Sterilization of Dental Instruments

Strep-a-Test Twister Test

SARASOTA MEMORIAL HOSPITAL

EHS Guide: Laboratory Trash Removal

B. Tasks and Procedures where employees, students or contractors can be exposed to bloodborne pathogens:

Evaluation of X-ray protective shielding used in dental offices in Kerman, Iran, in 2014

Principles and Techniques of Disinfection

2017 Oregon Dental Conference Course Handout

Device Technical File

What employees should know about UNIVERSAL PRECAUTIONS. They re work practices that help prevent contact with blood and certain other body fluids.

Cleaning and disinfection Tonometer measuring prisms, contact lenses and Desinset

Kodak Dental Radiography Series. Radiation Safety in Dental Radiography. Dental

ProUltra ULTRASONIC SURGICAL TIPS

EFFECTS OF OSMOTIC PRESSURE ON MICROBIAL GROWTH

UNIVERSAL PRECAUTIONS BLOODBORNE PATHOGENS WHAT SCHOOL STAFF NEED TO KNOW

SAFE INJECTION PRACTICES. Barbara J Connell MS,MT(ASCP)SH VP Clinical Services Medline Industries, Inc.

(cf / / Exposure Control Plan for Bloodborne Pathogens)

INSTRUCTIONS FOR USE FOR:

Part 4 Individual Surgeries

CDM 3 rd Year & Postdocs June 28 th 2017

Here are some frequently asked questions about Endodontic treatment:

Hand Foot & Mouth Disease & Enterovirus infections. Infection Control Measures Practical Aspects. Friday, 10 June 2010

TOPIC 4 HANDLING HEALTH PROTECTION & SAFETY PRACTICES FOR MEDICAL STAFF & WASTE HANDLERS TRAINING & PUBLIC EDUCATION

INVESTIGATION OF CHARACTERIZATION AND COMPOSITION OF DENTAL WASTES IN SAMSUN CITY CENTER

SFHOH4 SQA Unit Code H4PX 04 Contribute to the production of dental images

DTSS Practice Inspections

POS Perkins Statewide Articulation Agreement Documentation Coversheet

Infection Control. Copyright 2011, 2007, 2003, 1999 by Saunders, an imprint of Elsevier Inc. All rights reserved.

Transcription:

ca Applied Research Cite this article as: J Can Dent Assoc 2010;76:aXXX 2011;77:b93 Infection Control in Digital Intraoral Radiography: Evaluation of Microbiological Contamination of Photostimulable Phosphor Plates in Barrier Envelopes David S. MacDonald, BDS, BSc (Hons), LLB (Hons), MSc, DDS (Edin), FDSRCPS, DDRRCR (UK), FRCD(C); J. Douglas Waterfield, MSc, Fil.dr (Karolinska) Abstract Background and Objective: The detectors (both solid-state sensors and photostimulable phosphor [PSP] plates) used for digital intraoral radiography cannot be autoclaved, and barriers are typically used to prevent the spread of infection. The aim of this study was to determine the effectiveness of a barrier envelope system for PSP plates. Methods: Disinfected PSP plates were aseptically inserted into barrier envelopes and placed in a periapical location. One PSP plate was placed in each of 28 patients, and 12 plates in each of 2 volunteers (D.S.M., J.D.W.). After retrieval, each PSP plate was removed from its barrier envelope, immersed in trypticase soy broth and aliquots were plated on trypticase soy agar. Bacterial colonies were counted 2 days later. Results: Fifty-two PSP plates in barrier envelopes were evaluated for contamination. Quality assurance of the PSP plates before clinical placement revealed defects in the integrity of 4 barrier envelopes, caused by forceps-related damage or failure to achieve a uniform seal. These defects allowed substantial contamination. Contamination also occurred as a result of failure to extract the PSP plate from the barrier envelope cleanly. Of the 44 barriers with no obvious defects that were placed by either final-year dental students or a radiologist, only 3 allowed bacterial contamination of the PSP plate. Conclusion: Detectors contained in barrier envelopes remain a potential source of contamination. PSP plates must be disinfected between removal from a contaminated barrier envelope and placement in a new barrier envelope. In addition, placement into the barrier envelope should ideally be carried out under aseptic conditions. Finally, the integrity of each sealed barrier envelope must be verified visually before release to the clinic. Infection control in health care settings involves compliance with a set of principles that are based on the concept that all patients are potentially infectious. These internationally accepted principles, which are termed standard precautions, are regarded as fundamental to the prevention and control of infection in dental clinics. Their intent is to isolate various body substances through the use of protective barriers, such as gloves, masks and goggles, and through aseptic handling and disposal of contaminated sharps or waste, any of which may be a source of cross-contamination in a dental operatory. ca 2011 1 of 5

ca The advent of digital intraoral radiography has created new infection control challenges not seen with film-based imaging. With the latter mode of imaging, contamination of the film is prevented by complete disposal of the packaging. In contrast, digital detectors (both solid-state sensors and photostimulable phosphor [PSP] plates) are reused many times (in a variety of intraoral placements), but they are not suitable for autoclave sterilization; therefore, cross-contamination is possible. Prevention of the transfer of intraoral organisms has been attempted through the use of plastic barriers. However, 2 studies of PSP plates have indicated that cross-contamination is a substantial problem in digital radiography. 1,2 Bacterial contamination of the PSP plates can occur at a number of points in daily usage. For example, bacteria from sources outside the patient s oral cavity may contaminate both the PSP plates and the barriers. Contamination may originate during the manufacturing process, from ambient air and/ or through the use of latex gloves by dispensary staff during cleaning, disinfecting and packaging. 1 However, the most likely source of contamination is contact between the PSP plate and the patient s oral environment. In this situation, contamination of the PSP plate could result if there are perforations of the plastic barrier, if there is contact between the barrier and the oral fluids during removal for processing and/or if there is contact with contaminated gloves. Kalathingal and colleagues 1 and Negron and colleagues 2 assessed possible routes of cross-contamination during use, processing and disinfection of PSP plates. Kalathingal and colleagues 1 studied barrier integrity, one of the parameters associated with possible cross-contamination. The barrier used to hold an individual PSP plate usually consists of a plastic sealable envelope (here called a barrier envelope ). These authors evaluated the rate and source of contamination with use of gas sterilization in conjunction with this type of barrier. They found bacterial growth on 56% of the PSP plates (and 76% of the bacterial colonies selected from these plates grew on Mitis Salivarius agar), in spite of weekly gas sterilization and application of a 70% alcohol wipe between patients. 1 In a similar study investigating infection control for PSP plates in multiple-use tests, Negron and colleagues 2 reported that 61% of the PSP plates were contaminated with oral streptococci after being cultured for 24 hours. In neither of these 2 studies was the exact route of contamination determined, but their results clearly indicate that cross-contamination remains a problem in digital radiography. Given the paucity of published information on the subject of barrier integrity, this study was undertaken to test the efficacy of the barrier envelope used to isolate PSP plates from contamination with biological fluids. Methods PSP Plates, Barriers and Film Holder This study used the no. 2 PSP plate (30 mm 40 mm) and barrier system (Scan X #0 Barrier Envelopes [PN 73248-0]) supplied by Air Techniques (Corona, CA), with a Rinn film holder (Dentsply, Elgin, IL). The PSP plates used in this study were old and had been taken out of service; they were used only for the purpose of this study. Study Population The study involved 52 PSP plates: 12 inserted into the mouths of each of the 2 authors of this study and 1 for each of 28 patients recruited from the final-year dental clinic at the University of British Columbia. Patients were approached in writing to request participation, and they had the option to refuse (with further dental care not being contingent on their participation). The Clinical Research Ethics Board at the University of British Columbia approved the protocol involving human subjects. Assembly of PSP Plates in Barrier Envelopes Because barrier integrity was the focus of the study, great care was taken to ensure asepsis of the PSP plates. The asepsis procedure described below was carried out only for this experimental study; it is not a standard operating procedure used in the dental school. Working in a class II biological safety cabinet (Canadian Cabinets, Ottawa, ON), an operator wearing barrier gloves wiped each PSP plate twice with a 70% ethanol wipe. The efficacy of this 70% ethanol disinfection was formally tested, as follows. Two sets of PSP plates were contaminated 2 of 5 2011 ca

ca Table 1 Microbiological contamination of photostimulable phosphor (PSP) plates inserted in barrier envelopes Study parameter Total no. of PSP plates No. (%) contaminated Extent of contamination (CFUs/3 ml) Failed quality assurance 4 3 (75) 1152 3648 Failed clean extraction 4 3 (75) 406 1080 Placement by student practitioner a 24 2 (8) 24 48 Placement by faculty radiologist a 20 1 (5) 180 CFU = colony-forming unit. a These rows do not include data for PSP plates that failed the quality assurance test or that were not extracted cleanly after exposure to the oral environment. by immersion in trypticase soy broth to which saliva had been added 24 hours earlier. Half of the plates were treated with ethanol wipes as described, and the remaining contaminated plates were left untreated. Both groups of PSP plates were then immersed in fresh sterile trypticase soy broth, and aliquots were plated on trypticase soy agar. For subsequent testing, each sterilized PSP plate was handled with sterile forceps during insertion into the barrier envelope, and the barrier envelope s sticky strip was removed with the same forceps. The edges of the barrier envelope were then pressed firmly together. Each sealed barrier envelope was then inspected for visible perforations caused by the forceps, as well as for uneven sealing. Clinical Procedures Each barrier envelope containing a PSP plate was placed into a bite block, which was then placed in the mouth of a volunteer or patient, adjacent to the mandibular molars, for simulation of a periapical radiographic exposure. Each barrier envelope was left in place intraorally for 1 minute, but no radiographic image was taken (i.e., no volunteers or patients were exposed to radiation). A faculty radiologist (D.S.M.) placed the bite blocks for the 24 PSP plates in the mouths of the authors. Fourth-year dental students placed the bite blocks for the 28 clinic patients. After the 1-minute exposure to the oral environment, the PSP plates, still in their barrier envelopes, were transferred to a biological safety cabinet for processing. Evaluation of Microbial Contamination To demonstrate contamination of the barrier envelopes, 10 sealed barrier envelopes containing PSP plates were each placed in 3 ml of trypticase soy broth in a 60 15 mm petri dish for 1 minute. The barrier envelopes containing PSP plates were then removed, and 0.5 ml of each broth sample was plated on trypticase soy agar. To evaluate microbiological contamination of individual PSP plates, each barrier envelope was cut above the detector with sterile scissors. The PSP plate was then carefully removed with sterile forceps and placed in 3 ml of trypticase soy broth in a 60 15 mm petri dish for 1 minute. Instances when the PSP plate could not be removed cleanly without contacting the edge of the envelope were noted. After exposure of each PSP plate to the broth, 0.5 ml of broth was then plated on trypticase soy agar. All trypticase soy agar plates were allowed to dry and were incubated aerobically, along with a control plate, at 35 C for 2 days. At the end of the incubation period, the bacterial colonies were counted, and the counts were adjusted to total number of colonies per 3 ml. The presence of colonies, not their size, was the factor used to determine bacterial contamination. It was assumed that the presence of any growth indicated failure of the barrier envelope. Results Testing of the disinfection process with PSP plates that had been deliberately contaminated with oral microflora indicated 100% kill. This ca 2011 3 of 5

ca provided assurance that the PSP plates were sterile before placement in the mouths of participants. Quality assurance checks indicated that 2 PSP plates had been incorrectly sealed in their respective barrier envelopes. In 2 additional cases, the barrier envelope containing a PSP plate was perforated by the forceps. Three (75%) of these 4 PSP plates (placed by D.S.M.) became contaminated after placement in the oral environment (Table 1). Another potential source of contamination is the process of removing the PSP plate from its barrier envelope, because the barrier envelopes themselves are contaminated. More specifically, the contamination found on 10 barrier envelopes ranged from 1680 to more than 10 4 colony-forming units (CFU) per 3 ml of broth (individual data: 280, 510, 880, 2450, 2490 and > 2500 [for 5 envelopes] per 0.5 ml plated). In 4 clinical placements, extraction of the PSP plate from the barrier envelope was not carried out cleanly, and the PSP plate touched the sides of the barrier envelope upon removal. Subsequent culture revealed that 3 (75%) of these 4 PSP plates (placed by DSM) had been contaminated, as described above. The third and final analysis was designed to determine the extent of integrity of the barrier envelopes after use in a clinical setting and whether this integrity could be affected by clinical skill. Of the 44 PSP plates in barrier envelopes that passed the quality assurance test and were extracted cleanly after a 1-minute exposure to participants oral environment, 24 were placed by fourth-year dental students and 20 were placed by D.S.M. Subsequent culture revealed that 2 (8%) of the 24 PSP plates placed by students and 1 (5%) of the 20 PSP plates placed by the radiologist had unexplained contamination. Discussion PSP plates are reused many times in a variety of intraoral placements, which leads to the possibility of cross-contamination, the most likely source being contact with the oral environment. This study tested the efficacy of barrier envelopes designed to isolate PSP plates from contamination by biological fluids. In this study, contamination of the PSP plates resulted from perforation of the plastic barrier envelopes, incorrect sealing of the edges of the barrier envelopes and contact with the edge of the barrier envelopes during removal for processing. In a clinical situation, breaks in the integrity of the barrier envelope can be identified as small holes where it has been in contact with the plastic-covered forceps. Incorrect sealing can be identified by wrinkling of the edge of the barrier envelope along the seal line. It is also important to note whether a sealing adhesive strip has been applied to one edge of the barrier envelope lip: in this study, there was one instance of a manufacturing failure in which no adhesive had been applied. Every effort was made to ensure that the PSP plates used in this study were not contaminated. It was therefore interesting to note a substantial level of unexplained contamination among the PSP plates placed by dental students (8%) and a radiologist (5%). Although these results are not conclusive, it appears that the integrity of the barrier envelope may not be affected by clinical skill. There are only 2 possible explanations for the contamination observed in these instances. First, manufacturing defects in the production of the barriers may have resulted in leakage. Second, the barrier may have been compromised by the mechanical stress of placement, occupancy and subsequent retrieval from the mouth. From the study reported here, it was not possible to distinguish between these 2 possibilities. Most dispensaries do not have quality assurance protocols for assembly of PSP plates in barrier envelopes, nor do they typically have standard operating procedures for removal of a PSP plate from its envelope. It is therefore possible for contamination to spread between PSP plates during their manipulation. The findings reported here are supported by other studies. Investigators evaluating gas sterilization in combination with barriers for PSP plates found bacterial growth on 56% of the PSP plates (with 76% of bacterial colonies from selected contaminated PSP plates being affected by oral streptococci, as indicated by growth on Mitis Salivarius agar). This contamination was observed despite weekly gas sterilization and application of 4 of 5 2011 ca

ca a 70% alcohol wipe between patients. 1 Similarly, in an investigation of PSP plates in multiple-use tests, the authors found that 61% of the detectors were contaminated with oral streptococci after 24 hours of culture. 2 Unlike these earlier studies, the current study included attempts to identify the route or routes of contamination. Given the current findings and the results of previous studies, 1,2 it is clear that infection control challenges remain in the area of digital intraoral radiography. Consequently, several issues must be considered when using PSP plates. First, each PSP plate must be disinfected between its removal from the contaminated barrier envelope and placement in a new barrier envelope. Second, placement should ideally be carried out under aseptic conditions. Finally, the integrity of the sealed barrier envelope for each PSP plate must be visually inspected before release to the clinic. a 1. Kalathingal S, Youngpeter A, Minton J. Shrout M, Dickinson D, Plummer K, et al. An evaluation of microbiologic contamination on a phosphor plate system: is weekly gas sterilization enough? Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010;109(3):457-62. Epub 2010 Jan 8. 2. Negron W, Mauriello SM, Peterson CA, Arnold R. Crosscontamination of the PSP sensor in a preclinical setting. J Dent Hygiene. 2005;79(3):8 Epub 2005 Jul 1. THE AUTHORS Dr. MacDonald is associate professor and chair of the division of oral and maxillofacial radiology, faculty of dentistry, University of British Columbia, Vancouver, British Columbia. Dr. Waterfield is associate professor and chair of the division of oral biology, faculty of dentistry, University of British Columbia, Vancouver, British Columbia. Acknowledgements: We are grateful to Dr. Andrea Esteves, clinic director, and Dr. Joanne Walton, associate dean of academic affairs, for access to the clinic and for permission to approach the students respectively. We also thank the fourth-year students (2010-2011) and their patients for their participation in this study. Correspondence to: Dr. David MacDonald, University of British Columbia, Faculty of dentistry, 2199 Wesbrook Mall, Vancouver, BC V6T 1Z3. Email: dmacdon@ interchange.ubc.ca The authors have no declared financial interests. This article has been peer reviewed. References ca 2011 5 of 5