Ask EuroSafe Imaging. Tips & Tricks. CT Working Group. Optimization of scan length to reduce CT radiation dose

Similar documents
Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters

Ask EuroSafe Imaging. Tips & Tricks. CT Working Group

Managing Radiation Risk in Pediatric CT Imaging

How do the Parameters affect Image Quality and Dose for Abdominal CT? Image Review

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

A more accurate method to estimate patient dose during body CT examinations with tube current modulation

Ask EuroSafe Imaging Tips & Tricks. CT Working Group. CT in Pregnancy

To Shield or Not to Shield? Lincoln L. Berland, M.D.

3/5/2015. Don t Electrocute Me!: Common Misconceptions in Imaging and Radiation Safety (and What to Do About Them)

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

FDG-18 PET/CT - radiation dose and dose-reduction strategy

Computed tomography Acceptance testing and dose measurements

Automatic Patient Centering for MDCT: Effect on Radiation Dose

CT dose survey data acquisition form

Ask EuroSafe Imaging. Tips & Tricks. Paediatric Imaging Working Group. Shielding in pediatric CT

Scientific Exhibit Authors:

Combined Anatomical and Functional Imaging with Revolution * CT

Radiation Dose Reduction Strategies in Coronary CT Angiography

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

CT Dose Estimation. John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology. University of California Davis Medical Center

X-Ray & CT Physics / Clinical CT

CT SCAN PROTOCOL. Shoulder

Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer

Studies in both the United States and Europe have revealed that computed tomographic (CT) examinations account for only up to 15% of all imaging exami

Radiation Dose Reduction: Should You Use a Bismuth Breast Shield?

Translating Protocols Across Patient Size: Babies to Bariatric

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

Bone Densitometry Radiation dose: what you need to know

True Dual Energy. Dr. Stefan Ulzheimer, Siemens Healthcare GmbH. DEfinitely Siemens

HONG KONG COLLEGE OF RADIOLOGISTS. Higher Training (Radiology) Subspecialty Training in Computed Tomography

Doses from Cervical Spine Computed Tomography (CT) examinations in the UK. John Holroyd and Sue Edyvean

Survey of patients CT radiation dose in Jiangsu Province

Optimizing radiation dose by varying age at pediatric temporal bone CT

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

An audit of radiation dose of 4D CT in a radiotherapy department

B. CT protocols for the spine

CT Dose Optimization for Whole- Body PET/CT Examinations

Ask EuroSafe Imaging Tips & Tricks. CT Working Group. On the use of Diagnostic Reference Levels in CT

State of the art and future development for standardized estimation of organ doses in CT

Accounting for Imaging Dose

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

CT Dosimetry in the Clinical Environment: Methods and Analysis

CT Quality Control Manual FAQs

Assessment of effective dose in paediatric CT examinations

Reduced scan range abdominopelvic CT in patients with suspected acute appendicitis - impact on diagnostic accuracy and effective radiation dose

Computed tomographic pulmonary angiography procedures: Contrast media dilution from the venous to the systemic circulation

Managing Patient Dose in Computed Tomography (CT)

Assessment of Patient Dose from CT Examinations in Khorasan, Iran

Measurements of Air Kerma Index in Computed Tomography: A comparison among methodologies

Radiography/Radiology

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

JMSCR Vol 06 Issue 12 Page December 2018

Journal of Radiology and Imaging

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Low Dose Era in Cardiac CT

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Dose to Radiosensitive Organs During Routine Chest CT: Effects of Tube Current Modulation

Managing Cone Beam CT Dose in Paediatric Dental Imaging

Digital tomosynthesis (DT) has been well described as a

Dual Energy CT: a new tool in evaluation of the urinary tract stones composition in clinical practice - initial study

CT examination is a high-radiation-dose imaging technique

CT Versus MR for the Runoff

Utilization patterns and yield of Computed Tomography Pulmonary Angiogram (CTPA) at a tertiary teaching hospital - Liverpool Hospital

Why is CT Dose of Interest?

CT Guided Procedures And Interesting Cases. Stephen Kim, MD Diagnostic and Interventional Radiology

CT image guidance ensures accurate needle placement to

Vascular and Interventional Radiology Original Research

Modelling the effect of lead and other materials for shielding of the fetus in CT pulmonary angiography

Metal Artefact Reduction in CT

A study on CT pulmonary angiography at low kv and low-concentration contrast medium using iterative reconstruction.

CT Radiation Risks and Dose Reduction

Radiation Dose Estimations to the Thorax Using Organ-Based Dose Modulation

THE TUFFEST STUFF CT REGISTRY REVIEW Live Lecture Seminar SUNDAY CURRICULUM

Vascular Enhancement and Image Quality of CT Venography: Comparison of Standard and Low Kilovoltage Settings

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Introduction and Background

Cardiac Imaging Tests

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

How to Develop CT Protocols for Children

Chief Radiographer TEI Clinical Associate 2016

Pediatric Imaging Original Research

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION

Adopting DAP as a dose metric in CT

Radiation Dose To Pediatric Patients in Computed Tomography in Sudan

BrightSpeed Elite CT with ASiR: Comparing Dose & Image Quality Rule Out Pulmonary Embolism on Initial & Follow-Up Exam

CT angiography of pulmonary arteries to detect pulmonary embolism with low kv settings

RADIOLOGIC TECHNOLOGY (526)

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell

Ultra-low dose CT of the acute abdomen: Spectrum of imaging findings

Patient dose assessment of CT perfusion scanning at the RSCH

Low dose CT for renal colic: How to do it?

Computed tomography. Department of Radiology, University Medical School, Szeged

Ask EuroSafe Imaging Tips & Tricks. CT Working Group

Cone Beam CT-arthrography of the wrist: high resolution images at low radiation dose

Dual Energy CT Aortography: Can We Reduce Iodine Dose??

Detection of Renal Stones on Portal Venous Phase CT: Comparison of Thin Axial and Coronal Maximum- Intensity-Projection Images

Transcription:

Ask EuroSafe Imaging Tips & Tricks CT Working Group Optimization of scan length to reduce CT radiation dose Alban Gervaise (Centre Hospitalier Universitaire Nancy, FR) Mika Kortesniemi (HUS Medical Imaging Center, University of Helsinki, FI) Dean Pekarovic (University Hospital Ljubljana, SI)

Key points Scan length defines the exposed region of the patient. Scan length is directly related to CT radiation dose. A shorter scan length means lower dose if all other scan parameters and the anatomical region are held constant: «The smaller the exposed area, the smaller the dose». With rapid scanning capabilities of modern MDCT, tendency to extend beyond the desired target region of interest must be avoided. Optimization of CT scan length is an easy and simple way to reduce CT radiation dose. Specific dose effect depends on the patient attenuation how many sensitive organs are included in the scan range and it s vicinity (including dose from scattered radiation). Scan length should be adapted strictly to the clinical indication for each individual patient and must be limited to the zone of interest, previously identified by the scout views. Reduction of z-axis coverage can be performed e.g. for renal colic CT and CTPA for pulmonary embolism.

CTDI vol and DLP CTDI vol (volume CT dose index; mgy) is a standardized parameter to measure scanner radiation output. It basically describes the average dose within the scan range taking into account the scattered radiation. DLP (dose length product; mgycm) is the product of the length of the irradiated scan volume and the average CTDI vol over that distance. Both values are calculated by scanner and standardized cylindrical phantom ( 16 cm for head phantom and 32 cm for body phantom) and as such, they do not mean patient dose. CTDI vol and DLP are displayed in each CT console and can be easily monitored. DLP can be reduced by reducing the scan length. 12 cm 12 cm 7 cm 6 cm

Reducing the scan coverage of CTPA performed for pulmonary embolism above the aortic arch and below the base of the heart can reduce CT dose by 70 % without impairing PE diagnosis. CTPA in a 80 year old woman with pulmonary embolism. Scan length reduction could allow a 50% dose reduction with a correct visualization of the blood clots. Shakir K. et al. Emerg Radiol. 2O15

For renal colic CT, the scan coverage should be centred from the top of the kidneys to the lower edge of the bladder. Centring the acquisition for renal colic CT allows a dose reduction of 15-20%. Corwin MT et al. JCAT 2014

For appendicitis, the scan length can be reduced from the inferior margin of T10 and the superior border of pubic symphysis. Appendicitis in a 57 year old woman. Scan length reduction could allow a 25% dose reduction without impairing the diagnosis of appendicitis. Corwin MT et al. Abdom Imaging 2015

For lumbar spine CT, acquisition limit must be adapted to the clinical symptomatology. Example of a lumbar spine CT performed for L5-S1 radiculopathy. The CT-scan covered T11 to S3. A centring of the acquisition to L3-S2 allows to reduce CT dose by half.

One Finger More A simple example how to express the effect of one finger more (2,5 cm) of scan length in extra effective dose and number of chest x rays. - DKVRT, UMC LJ - Deak et al. Radiology 2010

Over-ranging: Implications on scan parameter choice Over-ranging means an extra longitudinal exposure in the beginning and end of the scan range in helical CT acquisition in order to assure an adequate set of raw data for CT image reconstruction. For short scan length: over-ranging can represent a significant portion of overall dose. Thus, short scan ranges should be scanned at lower pitch and lower beam collimation or with volumic mode on wide-area detector CT. Ex: Small joints, small regions of interest, head CT For longer scan length: over-ranging represents a small portion of overall dose. Thus, long scan ranges can be scanned with faster pitch and wider beam collimation to decrease scan times (e.g. Chest CT, Abdomen CT, extremity CT). Over-ranging can be mostly avoided with new scanner models with dynamic z- collimation. Example of a volumic mode acquisition of 16 cm with a 320- MDCT and a helical mode acquisition with a 64-MDCT. Note the additional dose exposure with helical mode due to overranging at the beginning and at the end of the scan if dynamic collimation is not available. - IAEA, CT Dose Management - Gervaise A et al. RSNA 2012

References Singh S, Kalra M. Scan parameters and CT radiation dose. In: Tack D, Genevois PA, Kalra M. (eds). Radiation dose from multidetector CT. Springer-Verlag Berlin Heidelberg, 2012, p369-387. Shakir K, Goodman LR, Lam CA, Midia EC. Dose reduction of 69% for computed tomography pulmonary angiography: reduced z-axis computed tomography pulmonary angiography retains accuracy in those younger than 40 years. J Comput Assist Tomogr 2013; 37:765-9. Corwin MT, Bekele W, Lamba R. Bony landmarks on computed tomography localizer radiographs to prescribe a reduced scan range in patients undergoing multidetector computed tomography for suspected urolithiasis. J Comput Assist Tomogr 2014; 38:404-7. Corwin MT, Chang M, Fananapazir G, Seibert A, Lamba R. Accuracy and radiation dose reduction a limited abdominopelvic CT in the diagnosis of acute appendicitis. Abdom Imaging 2015; 40:1177-82. Deak PD, Smal Y, Kalender WA. CT Multisection protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology 2010; 257:158-166. Gervaise A, Teixeira P, Villani N, Lecocq S, Louis M, Blum A. Musculoskeletal CT: how to reduce the dose? Poster RSNA 2012, LL-MKE4361. https://rpop.iaea.org/rpop/rpop/content/news/10-e-learning.htm