Aesculap Orthopaedics

Similar documents
Aesculap Orthopaedics. Instructions for use/technical description TKA application software Columbus and VEGA System

OrthoMap Express Knee Product Guide. OrthoMap Express Knee Navigation Software 2.0

Aesculap Orthopaedics OrthoPilot

ANATOMIC. Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0

Aesculap CeSpace TM PEEK and CeSpace TM XP Spinal Implant System Instructions for Use

PPS P I N P O S I T I O N I N G S Y S T E M GMK EFFICIENCY VERSION. Hip Knee Spine Navigation

Innovations 2017 & 2018

PediLoc Tibia Surgical Technique

Yasargil Permanent Aneurysm Clips

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

A New Benchmark in Tibial Fixation

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD

3.5 mm Locking Attachment Plate

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

Distal Cut First Femoral Preparation

A Non-CT Based Total Knee Arthroplasty System Featuring Complete Soft-Tissue Balancing

PATIENT MATCHED TECHNOLOGY IN KNEE REPLACEMENT

PROPHECY INBONE. Preoperative Navigation Guides

Navigation for total hip arthroplasty

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

INVISION Total Ankle Replacement System with PROPHECY Preoperative Navigation Revision of a Failed Agility Total Ankle Replacement

KASM Knee Articulating Spacer Mold. Surgical Summary

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

BLUEPRINT. 3D Planning + PSI SURGIC AL TECHNIQUE V 2.1 T I TA N I U M

BRAINLAB ORTHOPEDICS SOFTWARE SOLUTIONS TO IMPROVE PATIENT CARE

EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE.

MetaFix Ludloff Plate

Bone Preservation Stem

KneeAlign System Surgical Technique Guide

Aesculap Orthopaedics univation

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

Extramedullary Tibial Preparation

Signature Personalized Patient Care

Zimmer Patient Specific Instruments. Surgical Technique for Gender Solutions Natural-Knee Flex System

PediLoc 3.5mm and 4.5mm Bowed Femur Plate Surgical Technique

HIP SOFTWARE-GUIDED SURGERY

Metha Short Hip Stem System

JOINT RULER. Surgical Technique For Knee Joint JRReplacement

Approach Patients with Confidence

PINTRACE method. Navigation with or without robot assistance. The PinTrace method is based entirely on robotassisted

The PinTrace system. medical robotics

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique

Integra. Salto Talaris Total Ankle Prosthesis PATIENT INFORMATION

ConforMIS, Inc. 28 Crosby Drive Bedford, MA Phone: Fax:

Clinical Evaluation Surgical Technique

Patient Specific Instruments. Surgical Technique

Revolution. Unicompartmental Knee System

Computer Navigation in TKA The role of Robotic Surgery. Christos Yiannakopoulos, M.D., Ph.D.

Meniscus Reconstruction: Trough Surgical Technique

TOTAL KNEE ARTHROPLASTY SYSTEM

Aesculap Implant Systems

FIELD SAFETY NOTICE / PRODUCT NOTIFICATION

Knee Surgical Technique

PAL Pelvic Alignment Level

Surgical Technique Guide

Corporate Medical Policy

PediLoc Extension Osteotomy Plate (PLEO)

ARCH Laminoplasty System

8 Performing Medical Procedures

Case Report. Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology

Technique Guide. SureLock Distal Targeting Device. C-arm guided targeting for trochanteric fixation nail.

itotal Customized POSTERIOR-STABILIZED knee replacement system

RESECTION GUIDE SYSTEM. TRUMATCH Personalized Solutions Surgical Technique with ATTUNE Knee INTUITION Instruments

TrueSight Personalized Planning & Targeting System. Operative technique

P. F. C. Sigma RP Knee System surgical technique

KneeAlign 2 System. Surgical Technique Manual Tibia and Distal Femur Navigation

KneeAlign 2 System. Surgical Technique Manual Tibia and Distal Femur Navigation. About OrthAlign, Inc.

Signature Personalized Patient Care*

No two knees are alike

Total Knee Original System Primary Surgical Technique

OrthoMap Versatile Hip Navigation. Product Guide. OrthoMap Versatile Hip Software 2.0

HipNav: Pre-operative Planning and Intra-operative Navigational Guidance for Acetabular Implant Placement in Total Hip Replacement Surgery

Gamma3 TM Fragment Control Clip

INTRAMEDULLARY NAILING TIBIA AND FEMUR 1.3 TIBIAL AND FEMORAL NAILING FEMORAL NAILING WITH RETROGRADE INSERTION IMPLANTS AND OPERATING MANUAL

BLUEPRINT. 3D Planning + PSI SURGIC AL TECHNIQUE

Lapidus Arthrodesis System Instructions for Use

ARROW EZ-IO Intraosseous Vascular Access System Procedure Template

LMH. Minimal Bone Resection. Lesser Metatarsal Head Implant. Thin, low-profile design for minimal bone resection

Ovation Hip System. Surgical Technique

Integra. Silicone PIP Implant SURGICAL TECHNIQUE

Orthopedic Pre-operative Planning and Templating with Digital X-ray Images

ACETABULAR CUP SURGICAL TECHNIQUE

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

The A-Space SIBD Spinal System is a stand-alone device intended to be used with the four supplied bone screws if no supplemental fixation is used.

SURGICAL TECHNIQUE GUIDE

Surgical Technique 4.5/8.5MM BEAMING SYSTEM. Customer Service:

Summary HTA. Arthroplasty register for Germany. HTA-Report Summary. Gorenoi V, Schönermark MP, Hagen A

Zimmer PSI Knee System For Use with Persona The Personalized Knee System Surgical Technique

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

Sectra Orthopaedic Solutions

Institutional review board approval was obtained prior to the start of this study.

Klinikum rechts der Isar, Munich - Germany plans orthopedic surgeries with medicad

Monolateral External Fixation System for Trauma and Orthopaedics

Flexible Fragment Fixation. Surgical Technique

Conventus CAGE PH Surgical Techniques

PHALINX. Hammertoe Fixation SURGICAL TECHNIQUE

InCoreTM Lapidus System

SURGICAL TECHNIQUE. Pivot Bipolar Solitude Unipolar

Total Knee Replacement

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)

Transcription:

Aesculap Orthopaedics USA Instructions for use/technical description UKA application software univation X

USA Aesculap Orthopaedics UKA application software Contents 1. 2. 2.1 2.2 3. 4. 4.1 4.2 4.3 5. 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 5.13 6. 7. 7.1 8. Safe handling... 2 Product description... 3 Software description... 3 Software use and contraindications... 3 Application... 4 System components... 4 Components necessary for use... 4 Installing and starting the software... 4 Operating principle of the OrthoPilot software module... 5 Working with the OrthoPilot application software... 5 Special instruments for the OrthoPilot application... 5 Options... 6 Safety and functionality... 6 Safe operation plausibility checks... 7 Entering the patient data... 7 Data acquisition... 8 Kinematic data acquisition... 8 Locating the hip center without iliac transmitter... 8 Locating the hip center with iliac transmitter... 9 Registration of anatomic landmarks... 10 Plausibility checks... 11 Navigated bone preparation... 11 Quitting the software... 11 Protocol... 11 Information about the licenses used... 12 Info... 12 Technical Service... 13 1. Safe handling Caution: Federal law (USA) restricts this device to sale by or on order of a physician. Rx Only The present instructions for use must be kept available and accessible for all O.R. staff and all other users! When the OrthoPilot navigation system is used as an aid for implanting knee endoprostheses, all devices, the Basic System and the implants and instruments may only be used and applied as described in the respective instructions for use and product information documents. To ensure safe application of the OrthoPilot software module, users must make themselves familiar with the contents of the instructions for use and all product information documents prior to using the system. The OrthoPilot navigation system may be used only by qualified surgeons that are experienced in the manual operating technique and have received comprehensive training by Aesculap technicians or surgeons experienced in using the navigation system! Prior to beginning surgery with the system, make certain all instruments required for the manual operating technique are available. 2

We specifically point to the following product information documents: 2. Product description 2.1 Software description Designation Instructions for use of OrthoPilot system FS101.FS106 Instructions for use OrthoPilot operating system, operation, soft- ware (FS101/FS102) Art. no. TA012658 (USA) SOP-AIS-5001236 OrthoPilot UKA SURGICAL Technique DOC1376 Manual SURGICAL technique univation X DOC1156 The OrthoPilot Software-Module UKA is an application software for the computer aided navigation of surgical instruments, with the aim to achieve positioning of knee endoprostheses in the patient s joint. The patient data required for this procedure are registered intraoperatively. Passive infrared transmitters applied on the patient provide the link between the patient and the computer. The transmitters are located by an infrared camera connected to the computer. The instruments are also fitted with infrared transmitters, so that the spatial correlation between the instruments and the transmitter locations on the bone can be established by the computer. 2.2 Software use and contraindications The system can be used in all cases where a surgical unicondylar arthroplasty of a knee is indicated. Contraindications for these prostheses are listed in the documentation enclosed with the respective implants. The presence of excessive damage to the joint can make the determination of the joint center from kinematic data unreliable. If this is the case, the software automatically selects joint centers that are calculated redundantly from points scanned with sufficient precision. 4HIS PROCEDURE CANNOT BE PERFORMED IF THERE IS RESTRICTED RANGE OF MOTION WITH THE HIPÍ THE SYSTEM CAN ONLY BE USED IF THE (IP JOINT ON THE SURGICAL SIDE IS SUFFICIENTLY MOBILE A restricted range of motion of the hip joint, or a restricted range of movement coinciding with the indication for implanting an artificial hip, constitutes a contraindication against using the system! 3

USA Aesculap Orthopaedics UKA application software Use of the product is contraindicated in cases where bone characteristics or quality preclude the firm and secure anchoring of the transmitter fixation elements in the bone! Note: For further details and information regarding OrthoPilot Basic system FS101, see TA012658 (USA). Also refer to the instructions for use OrthoPilot operating system, operation, software SOP-AIS5001236 prior to putting the product into operation. 3. Application The software application described in this document is intended exclusively for use with the following implant system: 4. System components 4.1 Components necessary for use Designation Art. no. OrthoPilot system FS101 Passive transmitters FS633, FS634 and FS635 OrthoPilot markers single-use passive FS616 OrthoPilot CAP single-use markers FS618SU univation X navigation set ST0626 univation X instrument sets: Instruments for univation X ST0540 univation X univation X Tibia (optional) ST0544 Further information regarding the use of the respective system components can be found in the appropriate instructions for use and product information documents. 4.2 Installing and starting the software Note: For further details regarding the installation and startup of the software, as well as other system technical information, see instructions for use OrthoPilot operating system, operation, software SOP-AIS5001236. 4

4.3 Operating principle of the OrthoPilot software module The OrthoPilot software module FS234 for orthopedic applications in unicondylar knee arthroplasty allows precise guidance for the application of drill holes and bone cuts and for the implantation of endoprostheses. The given, patient-specific anatomic-geometrical elements, such as leg axes and pelvis position, which provide the basis for the alignment of the bone-preparation cuts and of the endoprostheses, are determined by the computer by means of kinematic and palpation data registered intraoperatively. The operating surgeon records the relevant anatomic structures by palpating them with a pointer. 4HIS ALLOWS THE PRECISE COMPUTATION FOR THE STEPS OF BONE PREPARATIONÍ THE COMPUTER CONTROLLED POSITIONING OF THE NAVIGATED INSTRUMENTSÍ ANDÍ CONSEQUENTLY PRECISE PREPARATION OF THE IMPLANT BED AND THE IMPLANT POSTION 5. Working with the OrthoPilot application software The following is an outline of the essential steps and critical points for successful data acquisition. The subsequent, necessary bone preparation steps are also performed with the help of the application software. These steps largely correspond to the steps required for manual unicondylar knee endoprosthetics. The complete, intraoperative workflow for the navigated operation is described in detail in product information brochure, DOC1376 SURGICAL TECHNIQUE OrthoPilot UKA Unicondylar Knee Arthroplasty. The OrthoPilot software module FS234 has been designed for exclusive use with the appropriate instrument system or endoprosthesis system, respectively. All components mentioned in this document have been harmonized in such a way that they provide for the user a complete system for bone preparation and/or prosthesis implantation. User error! To ensure safe use of OrthoPilot UKA application software, always follow Surgical Technique DOC1376. 5.1 Special instruments for the OrthoPilot application The special instruments are fitted with adapters for infrared transmitters. Navigation technology allows instrument positioning with millimeter and angledegree precision. Therefore, the OrthoPilot navigation system is equipped with extremely precise adjusting mechanisms for the resection depth, the frontal and sagittal angles, and the rotation. As OrthoPilot is calibrated only for use with these special instruments, only Aesculap instruments may be used with the system. The special instruments are subject to the relevant guidelines and regulations for cleaning and sterilization of autoclavable instruments. Further information in this regard can be found in the appropriate instructions for use of the implants, instruments and devices. 5

USA Aesculap Orthopaedics UKA application software 5.2 Options 5.3 Safety and functionality User error! Settings may only be changed by Aesculap software specialists. The OrthoPilot software can be adapted to individual users requirements in various ways: Use of passive IR transmitters only Activating/Deactivating acoustic feedback messages If the range of motion or the mobility of the hip is restricted, the alternative method for registering the hip center must be applied (using a reference basis on the iliac crest). The precision of the values displayed during the operation primarily depends on the quality of the landmarks registered kinematically or through palpation. Data acquisition requires adequate knowledge of the anatomic conditions. The bone structures displayed on the screen are not based on diagnostic imaging procedures carried out on the patient undergoing the surgical procedure. Consequently, the display does not represent the bone structure of the individual patient; it only serves as a visual aid for intuitive user guidance. Choosing default instrument set Choosing default surgeon's name Choosing default hospital department name Defining if ToolViewer screen is present or not after surgery screen in order to adjust localizer position with respect to surgical field The aim of each stage in the software is summarized in a short title displayed at the bottom of the screen. Choosing if Record Tibia Cut is inserted in the workflow or not 6

5.4 Safe operation plausibility checks As with every technical device, OrthoPilot is subject to possible malfunctions due to technical faults or user errors. However, since interventions performed with the OrthoPilot navigation system can be aborted at any time, to be continued with standard instruments, such malfunctions do not present an additional risk to the patient, provided they are discovered at an early enough stage. Therefore it is important, particularly at the early stages of using OrthoPilot, to continuously check the plausibility of the steps suggested by the system. Should there arise any doubts as to whether the system is functioning correctly, the test procedure must be repeated (if possible), or the intervention must be continued by non-navigated surgery using the conventional operating technique. 5.5 Entering the patient data In case of technical problems during the surgical procedure, (e.g. if the program suddenly shuts down), the anatomic geometry (e.g., the axis relations) can be registered again by restarting the application software. If the axis relations are registered anew after the restart, their plausibility with regard to radiological findings (e.g. full- length leg radiography, upright under load) must be rechecked. In this module, the camera can be positioned either contralaterally or ipsilaterally to the side of operation when the patient data are entered. Here, it must be ensured that during the data acquisition there is no mix-up between the medial and lateral side of the leg to be operated on. When selecting an instrument set, care must be taken when choosing available tools set in the operating room for the current surgery. To ensure that a chosen instrument corresponds to the user's intention, its name is always displayed. 7

USA Aesculap Orthopaedics UKA application software 5.6 Data acquisition 5.7 Kinematic data acquisition Kinematic data Data are registered through three different, basic methods: are registered to locate the joint cen- ters (hip and knee). Kinematic data registration Registration of palpated anatomic landmarks Registration of preoperative data via keyboard input All data registration steps must be carried out with the best possible precision. Also, other data used as input for the OrthoPilot system must be determined with maximum precision. Generally, each step of the program sequence should be confirmed as soon as the respective measurement result is displayed on screen and found matching the user s intention. The values displayed at the time of confirmation are saved to the log file and used for further calculations. Erroneous data confirmation or incorrect data input can result in miscalculations and, consequently, incorrect positioning of burr holes, incisions and implants. If transmitters are moved too rap- idly, the camera may be unable to track the transmitters, causing the traffic light symbol to signal red. This can happen in all steps in which the transmitters are moved through a relatively large area. 5.8 Locating the hip center without iliac transmitter This method of kinematic data registration is most sensitive in terms of data precision, because only one reference transmitter on the femur is used. In this way, additional trauma to the patient, caused by a second reference transmitter on the iliac crest, is avoided. Normally, the message Bad acquisition is displayed if the quality of the registered data is not good enough. Otherwise, the program automatically moves to the next program step as soon as sufficient data have been measured and recorded. The visibility status of each tracked tool is displayed by the colored traffic light, especially non- visibility status can be identified by a red color. 8

Since this registration of the hip center is unique in that it relies exclusively on the position and alignment of a navigation reference base in relation to the infrared camera (thereby avoiding a reference base at the iliac crest), it is extremely important that the camera position relative to the operating table remains fixed throughout such registration. (In all other steps, the relative position of two reference bases is used for data registration. Hence these results are impervious to camera movements.) 5.9 Locating the hip center with iliac transmitter Fixating a transmitter on the iliac crest is indicated in cases where the user prefers safe and precise determination of the hip center by means of two reference transmitters. This method should be applied if the necessary immobilization of the pelvis and, consequently, the precise determination of the location of the hip head center cannot be ensured otherwise. The pelvis tends to move inadvertently in the following cases: Restricted range of movement of the hip Adiposity of the patient Inconvenient position of a tourniquet Patients with peridural or spinal anesthesia without adequate immobilization Any discrepancy between the OrthoPilot data and radiographic data will likely affect the postoperative outcome. If the surgeon will not tolerate the discrepancies between the femoral axis angles taken from radiographs and the angles given by OrthoPilot, and if a repeat measurement of the hip without a pelvic pin does not produce a satisfactory result, the kinematic hip measurement must be carried out with the pelvic pin. The pelvic pin eliminates all interference in the computation of the hip center, (e.g. relative movement between the pelvis and the camera.) The kinematic hip center may be registered through free movement (without the defined circle on the screen) only after a reference basis has been fixed on the iliac crest with a bone screw. As this method of data registration requires relatively wide movements of the hip, it involves the risk of coincident pelvis movements, which, if only one transmitter is used, would remain undetected and could affect the computation of the hip center. 9

USA Aesculap Orthopaedics UKA application software 5.10 Registration of anatomic landmarks To obtain correct data, only apply mild force when using the pointer. Do not bend the pointer. Any use of bent instruments will result in incorrect computation of angles, distances and implant size. Check the pointer for proper functioning according to the specifications given in SOP-AIS-5001236. Inexperience with OrthoPilot, can result in inaccurate palpation points, which can result in incorrect measurements/displayed data (e.g. femur size.) Therefore, always perform plausibility checks of suggested dimensions. If in doubt, compare the electronic data with mechanical measurements obtained with the knee instruments. The calculation of the knee center uses both palpation and kinematic data. In this way the joint centers are located with precision. However, if large discrepancies between the two data sets are found, the software uses the joint center determined by palpation. Therefore, the palpations must be carried out with particular care. During anterior ankle point palpation in the software, a target range to be reached is set to 45 %-55 % regarding the length of the previously palpated transmalleolar axis. Special care must be taken that the instruments, especially the pointer, are not moved at all during data registration until the data have been saved. The data are saved as soon as the footswitch is pressed down. At the same time the software automatically moves to the next step of the operation. 10

5.11 Plausibility checks Once the data registration is complete, the overall leg axis angles must be checked for plausibility. If any discrepancies are found in this check, the surgeon may have to delete data already registered and repeat the steps Locating the hip center, Medial dorsal condyle, Medial and lateral malleolus and Anterior central point. Should such discrepancies persist, the iliac reference point or the manual technique may have to be used instead. Should the medial and the lateral sides become confused during palpation of the landmarks, or if the registered data are absolutely incorrect anatomically, a warning message indicating that the palpation data are incompatible is dis- played after registration of the anterior central point. This means that all data already registered must be deleted and registered again. This is done by moving back through the program sequence by pressing the left foot switch. As the foot switch is kept pressed for a while, the respective data are deleted and can be registered again. 5.12 Navigated bone preparation Note: Further steps and the complete, intraoperative workflow for the navigated operation are described in detail in product information brochure no. DOC1376 SURGICAL Technique OrthoPilot UKA Unicondylar Knee Arthroplasty. 5.13 Quitting the software Note: For further details and information on the OrthoPilot operating system, operation, software, see SOP-AIS-5001236. 6. Protocol Note: See instructions for use OrthoPilot operating system, operation, software SOP-AIS-5001236. 11

USA Aesculap Orthopaedics UKA application software 7. Information about the licenses used 7.1 Info For more information, choose the Info button (i button) in the top right section of the screen, see Fig. 1, while the application is running. LGPL This product uses Qt framework version 4.6.2 under the license of LGPL version 2.1. Qt is protected by copyright 2009, Nokia Corporation and/or its subsidiaries. Contact: Nokia Corporation (qt-info@nokia.com) Apache This product includes software developed by Apache Software Foundation (http://www.apache.org/). This is authorized by license for Apache version 2.0. Parts of this software are based on software copyright 1999, IBM Corporation; see http://www.ibm.com Touch-It Virtual Keyboard This product uses the Touch-It Virtual Keyboard developed by Chessware SA and is protected by copyright (http://www.chessware.ch/virtualkeyboard/). Fig. 1 We agree to the license terms of the above mentioned software products. For more information, please contact your national B. Braun/Aesculap agency. 12

8. Technical Service For service, maintenance or repairs, please contact your national Aesculap Representatives. Modifications carried out on medical technical equipment may result in loss of guarantee/warranty rights and forfeiture of applicable licenses. Service addresses Aesculap Implant Systems, LLC Attn. Aesculap Technical Services 615 Lambert Pointe Drive Hazelwood, MO 63042 Aesculap Repair Hotline Phone: +1 800 214-3392 484-821-9119 Fax: +1 314 895-4420 Other service addresses can be obtained from the address indicated ABOVE. 13

Technical alterations reserved Aesculap Implant Systems, LLC SOP-AIS-5001235 Ver. 2 10/16 SOP-AIS-5001235 3773 Corporate Parkway Center Valley, PA 18034 Phone: 866-229-3002 www.aesculapimplantsystems.com