Echo Boost Whitepaper

Similar documents
powerful versatile mobile

DC-40 Ultrasound System. powerful efficient sleek

DC-T6 Diagnostic Ultrasound System. versatile ergonomic mobile

Ultrasound 10/1/2014. Basic Echocardiography for the Internist. Mechanical (sector) transducer Piezoelectric crystal moved through a sector sweep

Ultrasound Physics & Terminology

Intuitive. Intelligent. Innovative. General Imaging

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

ACUSON P500. Ultrasound Anytime, Anywhere. ACUSON P500. siemens.com/acusonp500. siemens.com/acusonp500 1

GE Healthcare 9900 Innovation Drive Wauwatosa, WI U.S.A.

Intuitive. Intelligent. Innovative. General Imaging

Aixplorer MultiWave Ultrasound System An Innovation in Breast Ultrasound Imaging

Introduction & Physics of ED Ultrasound. Objectives. What? - Limited Studies. Who? - ED Docs

Innovation Meets Portability. Indeed. ALPINION MEDICAL SYSTEMS We are Ultrasound Professionals

LOGIQ V2. Simple. Fast. Precise. Empowering Point of Care Medicine.

ACUSON P500. Ultrasound Anytime, Anywhere. ACUSON P500. siemens.com/acusonp500. siemens.com/acusonp500 1

Introduction to Biomedical Imaging

LOGIQ E9 with XDclear

Women s Lifetime Partner

SAMSUNG. Mobile excellence. Excellence on the Move ULTRASOUND H60. Ultrasound system HM70A with Plus

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Confident and Conclusive Diagnosis with Flexible Solutions

Pushing the boundaries

LOGIQ E9 with XDclear

Intuitive. Intelligent. Innovative. General Imaging

InTouch Center Local Customer Teams InTouch Agreements Parts Support

Accuracy Versatility Mobility

Delivering Top Performance. Outstanding Value. Exceptional Reliability. ACUSON X150 Ultrasound System. Answers for life.

HEARTWORKS ADVANCING EDUCATION IN ULTRASOUND. Simulation in Cardiac Anatomy, Transesophageal & Transthoracic Echocardiography and Lung Ultrasound

Focus on your needs. Ultrasound system HS60 SAMSUNG MEDISON CO., LTD. CT-HS60 V1.0-GI-FT EN

GE Healthcare. Vivid i Cardiovascular ultrasound system

Surgical Probes अౠ.6,7,1 / ?K

Hitachi Aloka Medical manufactured one of the world s first diagnostic ultrasound platforms, and today this imaging modality has become the first

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Intraoperative Imaging and TTFM

Mobile excellence SAMSUNG. ULTRASOUND H60 Ultrasound system HM70A with Plus. Excellence on the Move SAMSUNG MEDISON CO., LTD.

Innovation Meets Portability. Indeed. ALPINION MEDICAL SYSTEMS We are Ultrasound Professionals

Carotid Doppler: Doppler wave forms obtained from the common, external and internal carotid arteries. As well as the vertebral and subclavian

Confident Diagnosis, Confident Decisions

Diagnostic approach to heart disease

Basic of Ultrasound Physics E FAST & Renal Examination. Dr Muhammad Umer Ihsan MBBS,MD, DCH CCPU,DDU1,FACEM

Automated Image Biometrics Speeds Ultrasound Workflow

High resolution ultrasound scanner for skin imaging

Ultrasound Principles cycle Frequency Wavelength Period Velocity

Daily inspiration. Ultrasound system HS70A SAMSUNG MEDISON CO., LTD. Scan code or visit to learn more

Aortic Stenosis: Spectrum of Disease, Low Flow/Low Gradient and Variants

China Portable Medical Electronic Devices Industry Report, 2010

DC-6. Diagnostic Ultrasound System

SONIMAGE HS1. Premium Portable Ultrasound

This appendix was part of the submitted manuscript and has been peer reviewed. It is posted as supplied by the authors.

Ultrasound Knobology

Concepts of Imaging and Knobology

Routine Quality Assurance Cookbook

Cardiology. Transthoracic Echocardiography

GE Healthcare LOGIQ P6. Performance within reach.

ACUSON Sequoia Echocardiography Platform Advancing the practice of echocardiography through workflow and innovation

ALPINION MEDICAL SYSTEMS We are Ultrasound Professionals

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

Vivid T8 Ultrasound. Cardiac and shared services. Together like never before from GE.

for Heart-Health Scanning

Ultrasound. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Oct 17th, 2016

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING

Clinical Echocardiography

siemens.com/nx3 Scan Smarter. ACUSON NX3 Series

Ultrasound Examination

Tissue Strain Analytics Virtual Touch Tissue Imaging and Quantification

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

Transthoracic Echocardiograph

Echelon Oval provides a robust suite of leading musculoskeletal imaging capabilities for detailed assessment of all anatomy for your most challenging

Underwater Acoustic Measurements in Megahertz Frequency Range.

Features and Benefits

RIGHT VENTRICULAR SIZE AND FUNCTION

IMAGE-GUIDED RADIATION THERAPY

Tissue Doppler Imaging in Congenital Heart Disease

Evolution and Revolution of System Architecture with New Generation Technology

Qualification of Manual Phased Array Ultrasonic Techniques for Pipe Weld Inspection in Nuclear Power Plants

FOR IMMEDIATE RELEASE

Vision of a new dimension

Adult Echocardiography Examination Content Outline

Fulfilling the Promise

LVHN Cardiac Diagnostic Testing PCP/PCP Office Testing Cheat Sheet. September 2017

Confident Diagnosis, Confident Decisions

Improvement in Endocardia1 Border Delineation Using Tissue Harmonic Imaging

Image optimization for critical care US

ECHOCARDIOGRAPHY. Patient Care. Goals and Objectives PF EF MF LF Aspirational

Vivid T8 Ultrasound. Cardiac and shared services. Together like never before from GE. Take rugged reliability to challenging conditions.

Vivid S6. Cardiovascular ultrasound system. GE Healthcare. Davis Medical

Make a larger impact with a smaller footprint.

shear wave elastography

Martin G. Keane, MD, FASE Temple University School of Medicine

GE Healthcare. Logiq P5 Premium

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

Automated Volumetric Cardiac Ultrasound Analysis

Terminology Tissue Appearance

Introduction to TEE using Heartworks Echocardiography Simulator

Learning Objectives. Ultrasound for the Primary Care Provider. Portable Ultrasound: Laptops, Tablets, Plug-in Probes, and Pocket devices

ACUSON Sequoia C512 Echocardiography System. Transducers.

I have no financial disclosures

Adel Hasanin Ahmed 1

WELCOME! Introduction to Bedside Ultrasound

DP-50 Mindray DP-50 Digital Ultrasonic Diagnostic Imaging System Outstanding image performance in a compact design

Transcription:

MINDRAY WHITEPATER Echo Boost Whitepaper is a trademark owned by Shenzhen Mindray Bio-medical Electronics Co., LTD. Specifications subject to changes without prior notice. 2013 Shenzhen Mindray Bio-medical Electronics Co., LTD. All rights reserved. Mindray is listed on the NYSE under the symbol MR Mindray Building, Keji 12th Road South, High-tech Industrial Park, Nanshan, Shenzhen 518057, P.R. China Tel: +86 755 8188 8998 Fax: +86 755 26582680 E-mail: intl-market@mindray.com Website: www.mindray.com

How Echo Boost can help optimize echo examinations By Dr. Zhiwei Shi, Research Head, Mindray Ultrasound Background Compiled by: Charlie Ye, Product Specialist, Mindray Ultrasound Extensive clinical diagnosis experience has been obtained within the field of myocardium disease, coronary disease, valve disease, cardiac tumor and congenital disease by echo practitioners, making echocardiography to emerge as a rather common practice within the last couple of decades. Technologies such as B-mode, M-mode, Color Doppler etc. continue to contribute in the improvements within echocardiography. However, B-mode, as a robust and direct anatomical visualization technology, remains to be the most important one in echocardiography. Ultrasound waves used for echo imaging consist of main lobe and side lobe. Although side lobe is much weaker than main lobe, when side lobe propagates through hyperechogenic region (pericardium or free air bubbles), it generates useless clutter which is much stronger than real echo, leading to creation of noise in the chambers. During a regular echo scan, ultrasound probe is usually placed at the parasternal area or the fourth intercostals. For patients with wider intercostals space, ultrasound waves are easier to penetrate into the tissue. However, for patients with smaller intercostals space, part of ultrasound waves transmitted or echo signals are blocked by ribs due to its high density and strong attenuation, forming a blind area underneath the ribs. Hence, cardiac tissue located within the blind area tends to be of low S/N ratio, resulting in less information being obtained from the region. Due to different body types and attenuation rate, signals transmitted in tissue vary from person to person. What s more note worthy for echocardiography, is that the heart and chest movement can make a case more complicated than any other organ. For instance, an eco scan conducted on one patient, at same position, orientated at same view, can result in different images being obtained from time to time. The distribution of signal intensity differs depending on the body type, time and position. To get better image quality, it is necessary to optimize imaging parameters for different cases. 1

Echo Boost Utilizing a unique intelligent data receptive method for echo data analysis for specific region, Echo Boost is a fully self-adaptive signal processing technology, designed to optimize whole field uniformity of myocardium and chamber. Echo Boost uses a receptive field technology to get echo data. Receptive field originates from neurology, in which neurons are activated as a result of stimulation in a specific region, however, for ultrasound; it applies to auto adaptive reception for echo received. For instance, in Graphic 1, waves are relatively high intensity echo Echo1, Echo2, Echo3, and other dash lines indicate low echo region such as chamber. Horizontal and vertical lines specify the location of receptive field and intensity distribution of the receptive field respectively. Location of Receptive Field divides a region into dozens of smaller images, and analyzes each region individually. During processing, the center of region is very active, and the outer area of the region suppresses the echo reception. Intensity Receptive Field detects intensity distribution, and estimates current echo signals, obtaining any signal characteristic in current receptive field. The signal is detected not only from spatial distribution, but also from intensity, covering whole range of echo signals, with ability to suppress noise and boost useful weak signals. Intensity distribution of receptive field Echo 1 Echo 2 Echo 3 Location of receptive field Graphic 1 Echo Boost When receptive field signal characteristic acquisition is finished, ehco signals are processed as illustrated below: for weak echo Echo1, the signal is boosted to a user visible range; for stronger signal Echo2, the 2

signal is compressed to avoid to be too bright to increase detail info; for Echo3, part of gain and contrast is amended, keeping homogeneity with improved Echo1 and Echo2. Before Boosted Echo 1 Echo 2 Echo 3 Display Range After Boosted Echo 1 Echo 2 Echo 3 Display Range Benefits Graphic 2 Echo Boost demo a) Significantly improves B-mode whole field uniformity of cardiac image b) Significantly improves contrast resolution of cardiac tissue and chambers, reducing chamber noise Case Study A series of echo examinations were conducted on 3 different patients to compare the result and test the validity of the Echo Boost technology. It can be concluded that Echo Boost can effectively improve the uniformity and contrast of an image and at the same time reduce the noise especially in chamber for all body types. Case1: Easy patient: Male, 61 yrs, 60 kg, with Rheumatoid Arthritis and Hypertension for 13 yrs 3

Graphic 3: 4-Chamber view, Echo Boost display (L: Echo Boost off, R: Echo Boost on) Graphic 4: PLAX, Echo Boost display (L: Echo Boost off, R: Echo Boost on) Conclusion: Echo Boost significantly improves whole filed uniformity and near field contrast resolution resulting in clearer chamber view and better far field. Case 2: Moderate patient: Male, 58 yrs, 65kg, Chronic Renal Failure for 2 yrs Graphic 5: 4-Chamber view, Echo Boost display (L: Echo Boost off, R: Echo Boost on) 4

Graphic 6: Subxiphoid Cardiac View, Echo Boost display (L: Echo Boost off, R: Echo Boost on) Conclusion: Clearer Chamber and Better Uniformity Case3: Difficult patient: Male, 55 yrs, 77 kg, Mild Hypertension, smoking for a long time Graphic 7: PSAX, Echo Boost display (L: Echo Boost off, R: Echo Boost on) Conclusion: Better Tissue Contrast and Clearer Chamber View 5