Continuing the Tradition. VerSys Heritage Hip System

Similar documents
Following a tradition of success. VerSys Heritage Primary Hip Prosthesis Surgical Technique

Versys Advocate V-Lign and Non V-Lign Cemented Hip Prosthesis

The proven, simple solution. CPT 12/14 Hip System

Optimum implant geometry

Optimum implant geometry

M-SERIES. Modular Femoral Stem AN ACCURATE MATCH EVERY TIME

Optimum implant geometry

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

9800 Metric Blvd. Austin, Texas

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Bone Preservation Stem

Featuring. Technology. Product Rationale

Zimmer Segmental System

VERSYS HERITAGE REVISION HIP PROSTHESIS. Surgical Technique for Revision Hip Arthroplasty

*smith&nephew SL-PLUS Cementless Femoral Hip System. Product Information

One system for all revision types

HELIOS h i p s y s t e m

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Design Rationale. ECHELON Primary Hip System

CPCS. Training Manual. Collarless Polished Cemented Stem

Specifications guide ECHELON. Hip System

Zimmer Segmental System. Surgical Technique for Proximal Femoral Replacement and Intercalary Segments IMAGE TO COME

AML Hip System. Design Rationale/ Surgical Technique

Preoperative Planning. The primary objectives of preoperative planning are to:

PLR. Proximal Loading Revision Hip System

Metha Short Hip Stem System

Motion in Every Step

Surgical Technique. Hip System

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

VerSys Fiber Metal Taper Hip Prosthesis. Surgical Technique

Bone Bangalore

A further enhanced classic. Wagner SL Revision Hip Stem

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Answer. Hip System Design Features:

Understanding Hip Implant Options

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

ZMR Crossover Instruments. Abbreviated Surgical Technique

28 Surgical Technique

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

Restoration Modular Revision Hip System. Choice Matters

Section of Modular Hip Prostheses cemented. TMC-3 Modular Hip Prosthesis, cemented. TMC-3 Modular Hüftprothese, zementiert

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

*smith&nephew SBG Anatomical Hip Stem Prosthesis. Product Information

Clinical Evaluation Surgical Technique

Exeter. Technical Guide

Reaching new heights. Comprehensive. Efficient. Simple.

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Integra. Titan Modular Shoulder System, 2.5

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

PROFEMUR Total Hip System P R O D U C T C A T A L O G

Natural-Hip System. Surgical Technique. Addressing surgical concerns comprehensively

CPT 6 Stainless Steel Primary Hip System

LPS SYSTEM POCKET GUIDE

RECLAIM REVISION HIP SYSTEM

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

CLINICAL PAPER / ORTHOPEDIC

Aesculap Trilliance Triple Tapered Polished Hip Stem

Avenir Femoral Hip System

VerSys 6 Beaded FullCoat Plus Hip Prosthesis

Optimizing function Maximizing survivorship Accelerating recovery

Tri-Lock Bone Preservation Stem

Absolut TM Cemented Stem. Surgical Technique

5A* ODEP. Conserving bone. Preserving soft tissue. Restoring biomechanics. rating

APS Natural-Hip System

Approach Patients with Confidence

Impact of Intramedullary Reaming Depth on Establishing Femoral Canal Axis in the Sagittal Plane

A Proven Concept. Alloclassic Zweymüller Stem

ZMR Porous Revision Hip Prosthesis. Surgical Technique IMAGE TO COME

CLS Brevius Stem with Kinectiv Technology

TaperFit. Cemented Total Hip Replacement Surgical technique

Stability without compromise. Epsilon Durasul Constrained Insert

Common Instruments for Biomet Hip Systems

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

ZMR CROSSOVER INSTRUMENTS AND SURGICAL TECHNIQUE. Surgical Technique for Revision Hip Arthroplasty

Charnley Total Hip Arthroplasty with Use of Improved Cementing Techniques A MINIMUM TWENTY-YEAR FOLLOW-UP STUDY

S U R G I C A L T E C H N I Q U E

Trabecular Metal Tibial Cone Surgical Technique

CLS Spotorno Hip Stem A Milestone in the History of Hip Replacements

Revision. Hip Stem. Surgical Protocol

Progeny Hip Stem. Surgical Protocol and Product Specifications

Approach Patients with CONFIDENCE

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

Shunsaku Nishihara 1, Nobuhiko Sugano 1, Takashi Nishii 1, Hisashi Tanaka 2, Hideki Yoshikawa 1, and Takahiro Ochi 1

EXACTECH HIP. Operative Technique. Tapered and Splined Press-Fit Stems. Cemented Femoral Stems. Renewing Innovations. Enduring Solutions.

Cementless Tapered Femoral Stem Surgical technique

Cementless Tapered Femoral Stem Surgical technique

Surgical Technique r5.indd 1 12/8/10 10:36 AM

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

Approach Patients with Confidence

Versatility in a proven design. Trilogy Acetabular System

CONGENITAL HIP DISEASE IN YOUNG ADULTS CLASSIFICATION AND TREATMENT WITH THA. Th. KARACHALIOS, MD, DSc PROF IN ORTHOPAEDICS

Fixed and Variable Geometry Total Shoulder Arthroplasty

ACETABULAR CUP SURGICAL TECHNIQUE

The Leader in Orthopaedic Innovation

PRODUCT SCHEDULE FOR CERTIFICATE CE JRI ORTHOPAEDICS LIMITED

REVISING THE DEFICIENT PROXIMAL FEMUR

Triple Tapered Stabilised Hip C-STEM AMT. Surgical Technique

Transcription:

Continuing the Tradition VerSys Heritage Hip System

Heritage Following the Tradition The low-friction hip prosthesis developed by Sir John Charnley has more than a 20-year history of outstanding results. 1 With the VerSys Heritage Hip System, Zimmer has applied this successful concept to primary, revision, and CDH implants, offering a wide range of styles and sizes for most cemented hip indications. All three stem options preserve the geometry and polished surface characteristics of that first-generation prosthesis, while incorporating additional features designed to further enhance implant performance. Rectangular Cross-Sectional Geometry incorporating a flat back design consistent with the Charnley design philosophy, helps enhance torsional stability. Tapered Distal Tip design helps reduce strains in the cement compared to conventional stems with non-tapered distal hole designs. 4,5 The distal centralizer fits over the outside diameter of the stem tip. Smooth, Polished Surface Finish on forged, high-strength Zimaloy Cobalt-Chromium-Molybdenum Alloy. VerSys Hip System Instrumentation utilizes a core set of instruments for a system approach to provide a simple, precise, and reproducible implantation.

Wide Range Of Motion results from optimized neck geometries. 5mm Minimized Conical Collar, characteristic of the original Charnley design philosophy, acts as an insertion guide to promote accurate alignment and centralization. Extended Offset options are possible because of a parallel medial neck shift that does not change the stem s 135 neck angle or increase leg length. 2,3 Optional Proximal Sleeve Centralizer helps provide for an optimal cement mantle by neutrally positioning the femoral component. Two recesses in the proximal body help position the centralizer on the stem. Distal Centralizer with a five-point star design configuration helps improve cortical diaphyseal contact and stem alignment when compared to distal centralizers with four prongs. TIME (YEARS) Kaplan Meier Survivorship Analysis of Revisions of Charnley-Type Implants for Stem Loosening The VerSys Heritage Hip is true to the original form of Sir John Charnley s first-generation hip stem, which has proven to be more successful than second-generation designs. 6,7 SURVIVORSHIP 0 2 4 6 8 10 12 14 16 1 0.9 0.8 0.7 1st Generation 2nd Generation

Revision Long-Stem Options Building on the solid foundation of the VerSys Heritage design, the revision prostheses offer additional stem length, neck length, and offset options. This allows the system to meet the anatomical requirements of Type I and Type II femoral deficiencies and, in some cases, Type III deficiencies. Increased Neck Length and Offset compared to the standard neck length and offset, help restore proper joint kinematics in revision cases. Full-Length, All-Metal Provisionals allow for an accurate trial insertion and reduction regardless of surgical approach. Threaded Bullet Tip helps stabilize the provisional stem distally for more accurate trial alignment.

CDH Congenital Dysplasia Hip Available in two sizes, the CDH prosthesis is designed to address the anatomical characteristics associated with developmental dysplasia and congenital dislocation of the hip. Generally, the CDH stems are smaller than the primary and revision stems with less curvature on the medial face to accommodate the endosteal anatomy of a hypoplastic canal. The reconstruction is further facilitated by a neck angle of 125, a shortened neck length, and a minimal offset. Size 9 with a minimized medial curve and femoral offset, accommodates congenital dislocation, allowing the acetabular component to be placed in its true anatomical position. Full-Length, All-Metal Provisionals allow for an accurate trial insertion and reduction regardless of surgical approach. Threaded Bullet Tip helps stabilize the provisional stem distally for more accurate trial alignment. Size 10 accommodates the anteverted and valgus position of the femoral neck in developmental dysplasia. Neck Length & Offset accommodate CDH anatomy.

References 1. Kavanagh BF, Wallrichs S, Dewitz M, et al. Charnley low-friction arthroplasty of the hip: twenty-year results with cement. J Arthroplasty. 1994;9(3). 2. Steinbert B, Harris WH. The offset problem in total hip arthroplasty. Contemporary Orthop. 1992;24(5). 3. Davey JR, O Connor DO, Burke DW, et al. Femoral component offset: its effect on strain in bone cement. J Arthroplasty. 1993;8(1). 4. Estok DM, Ramamurti BS, Weinberg EW, et al. A stem design changes to reduce peak cement strains around cemented total hip arthroplasty by 45%. Presented at: 63rd Annual Meeting of the American Academy of Orthopaedic Surgeons; Feb 22-26, 1996; Atlanta, GA. 5. Hanson PB, Walker RH. Total hip arthroplasty cemented femoral component distal stem centralizer effect on stem centralization and cement mantle. J Arthroplasty. 1995;10(5):683-689. 6. Dall DM, Learmonth ID, Solomon MI, et al. Fracture and loosening of Charnley femoral stems: comparison between first-generation and subsequent designs. J Bone Joint Surg(Br). 1993;75-B:259-265. 7. Schulte KR, Callaghan JJ, Kelley SS, Johnston RC. The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. J Bone Joint Surg. 1993;75-A:961-975. Contact your Zimmer representative or visit us at www.zimmer.com +H124977857101001/$081218R1A09% 97-7857-101-00 Rev. 1 1ML Printed in USA 2001, 2003, 2008 Zimmer, Inc.