The proven, simple solution. CPT 12/14 Hip System

Similar documents
HELIOS h i p s y s t e m

CPT 12/14 HIP SYSTEM. Surgical Technique for Primary Hip Arthroplasty

9800 Metric Blvd. Austin, Texas

Continuing the Tradition. VerSys Heritage Hip System

Bone Preservation Stem

CPT 6 Stainless Steel Primary Hip System

Absolut TM Cemented Stem. Surgical Technique

Optimum implant geometry

CPCS. Training Manual. Collarless Polished Cemented Stem

Optimum implant geometry

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Optimum implant geometry

TaperFit. Cemented Total Hip Replacement Surgical technique

Aesculap Trilliance Triple Tapered Polished Hip Stem

Following a tradition of success. VerSys Heritage Primary Hip Prosthesis Surgical Technique

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Exeter. Technical Guide

CPT 12/14 HIP SYSTEM. Surgical Technique for Femoral Impaction Grafting in Revision THR

PLR. Proximal Loading Revision Hip System

The Leader in Orthopaedic Innovation

Approach Patients with Confidence

Versys Advocate V-Lign and Non V-Lign Cemented Hip Prosthesis

A further enhanced classic. Wagner SL Revision Hip Stem

Featuring. Technology. Product Rationale

Preoperative Planning. The primary objectives of preoperative planning are to:

Approach Patients with Confidence

ZMR Crossover Instruments. Abbreviated Surgical Technique

Fixed and Variable Geometry Total Shoulder Arthroplasty

Section of Modular Hip Prostheses cemented. TMC-3 Modular Hip Prosthesis, cemented. TMC-3 Modular Hüftprothese, zementiert

Bone Bangalore

Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

Bi-Polar 22.2mm & 28mm System - Operative technique

Surgical Technique. Hip System

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

TOTAL HIP REPLACEMENT:

ZMR CROSSOVER INSTRUMENTS AND SURGICAL TECHNIQUE. Surgical Technique for Revision Hip Arthroplasty

Avenir Femoral Hip System

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

Optimizing function Maximizing survivorship Accelerating recovery

TaperFit. Cemented Femoral Stem Product rationale

Surgical Technique r5.indd 1 12/8/10 10:36 AM

Arcos Modular Femoral Revision System

Cemented femoral stem - type CSC

VerSys 6 Beaded FullCoat Plus Hip Prosthesis

Reaching new heights. Comprehensive. Efficient. Simple.

Answer. Hip System Design Features:

Furlong H-A.C. THR System

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

VerSys Fiber Metal Taper Hip Prosthesis. Surgical Technique

Scan Bi-Polar 22/28. Operative Technique

PRODUCT SCHEDULE FOR CERTIFICATE CE JRI ORTHOPAEDICS LIMITED

Trabecular Metal Tibial Cone Surgical Technique

SURGICAL TECHNIQUE. Entrada Hip Stem

Restoration Modular Revision Hip System. Choice Matters

MetaFix Cementless Total Hip Replacement Product overview

Zimmer Segmental System

VERSYS HERITAGE REVISION HIP PROSTHESIS. Surgical Technique for Revision Hip Arthroplasty

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

Design Rationale. ECHELON Primary Hip System

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

Progeny Hip Stem. Surgical Protocol and Product Specifications

HIP CONTINUUM OF CARE. Trauma and Joint Reconstruction Hip Portfolio

CLS Spotorno Hip Stem A Milestone in the History of Hip Replacements

One system for all revision types

RECLAIM REVISION HIP SYSTEM

operative technique Kent Hip

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Product Rationale. Where Strength and Modularity Connect

Revision. Hip Stem. Surgical Protocol

Hip Fracture Management. Product overview

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique

28 Surgical Technique

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

Specifications guide ECHELON. Hip System

APS Natural-Hip System

CLS Brevius Stem with Kinectiv Technology

Aesculap Orthopaedics Excia. Hip Stem

21st Century Fracture Management ETS. Surgical Protocol

FLH /11

Proven technology for customized solutions. Revitan Curved Revision Hip System

Ovation Hip System. Surgical Technique

Cementless femoral stem type SF

Trabecular Metal Primary Hip Prosthesis. Surgical Technique IMAGE TO COME. The Best Thing Next to Bone

Exeter. Designed for Anatomic Restoration. Clinical Evidence Education

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Natural-Hip System. Surgical Technique. Addressing surgical concerns comprehensively

*smith&nephew SL-PLUS Cementless Femoral Hip System. Product Information

Restoration Modular. Revision Hip System Surgical Protocol

Approach Patients with CONFIDENCE

MULTIPOLAR BIPOLAR CUP. Surgical Technique

LPS SYSTEM POCKET GUIDE

Lubinus Classic Plus Hip Prosthesis System

MetaFix. Cementless Total Hip Replacement Surgical technique

FEMORAL REVISION IN TOTAL HIP ARTHROPLASTY

Clinical Evaluation Surgical Technique

Transcription:

The proven, simple solution CPT 12/14 Hip System

Primary CPT Hip The proven, simple solution 5mm The collarless, polished, doubletaper design concept used in the CPT 12/14 Hip System has proven itself clinically in more than 25 years of use. 1 This distinctive design philosophy is based on the use of natural compressive forces to help ensure that the implant is firmly seated and wedged within the cement mantle. The CPT System, in cobaltchromium 2,3 and stainless steel, 4,5 * has achieved long-term clinical success since its introduction in the early 1990s. While retaining its original geometry below the osteotomy line, the CPT System has an expanded portfolio to offer more sizing and offset options. Extended and Extra-Extended Offsets Because of the strength of cobalt-chromium, offset options are provided without dimensional changes to the stem body below the osteotomy line. 1,867 PRIMARY TOTAL HIP ARTHROPLASTIES 1.4% CASES REVISED 5mm 5mm Clinical Reliability In a multicenter clinical study conducted in the U.K. with stainless steel* prostheses, the revision rate for 1,867 CPT Hip arthroplasties performed by 31 surgeons was 1.4% at 7 years. The most common reason for revision was recurrent dislocation. This ongoing study demonstrates good to excellent midterm results with the CPT Stem. 4 * Not available for commercial distribution in the U.S.A. Increased Range of Motion Reduced neck geometry, larger head sizes, and corresponding Longevity Highly Crosslinked Polyethylene Liners provide enhanced range of motion and joint stability.

Single rasp per size Allows the surgeon to make intraoperative stem offset changes without re-rasping. 12/14 Neck Taper Accommodates a complete selection of femoral heads with head center options of -3.5mm, 0mm, +3.5mm, +7.0mm, and +10.5mm. Reduced neck geometry Allows an optimized range of motion. Cobalt-Chromium Alloy Due to its high fatigue strength, allows extended and extra-extended offsets without changing the body size. Clinical experience with cobalt-chromium CPT Stems spans 10 years. Highly Polished Surface Designed to work in conjunction with the taper geometry to enhance stem stability. Stable Fixation -ray films show evidence of stable fixation of the CPT Stem in the cement mantle. Distal Centralizer The PMMA distal centralizers help ensure central positioning and provide a space for the stem to subside without point loading on the distal cement mantle.

Revision CPT Hip The proven, simple solution Following the same successful design criteria, the CPT 12/14 Hip System also offers long stem components in seven sizes, including valgus neck options for revision applications. The natural compressive forces that help lock the stem into the femoral canal also facilitate the impaction of allograft into bone defects, making the CPT Revision Stems ideal for both cemented revision and impaction grafting indications. Proximal Taper 15mm Dual Taper Design Maintains the proven CPT taper proximally and transitions to a more gradual taper distally to gain stem length. Valgus Neck Angle of 145 Stem options provide an additional means of increasing leg length without increasing offset or a means of optimizing proximal bone support while maintaining leg length. Distal Taper

Cobalt-Chromium Alloy Provides excellent fatigue strength, allowing for a reduced neck geometry below the taper to provide greater range of motion. Highly Polished Surface Designed to work in conjunction with the taper geometry to enhance stem stability. 12/14 Neck Taper Accommodates a complete selection of femoral heads with head center options. Modular Tamps The modular tamping system is designed to simplify the impaction grafting technique by allowing for focus first on distal packing and then proximal reconstruction. Distal Centralizer The PMMA distal centralizer helps ensure central positioning and provide a space for the stem to subside without point loading on the distal cement mantle.

Impaction Grafting The natural compressing forces that help lock the stem into the femoral canal also facilitate the impaction of allograft into bone defects. The CPT 12/14 System includes modular imaction grafting instruments designed to simplify the technique and provide excellent clinical results. Primary Stems Size Standard Offset Extended Offset Extra-extended Offset Size 1, 130mm Size 2, 130mm Size 3, 130mm Size 4, 130mm Size 5, 130mm Revision Stems Size Standard Offset Extended Offset Size 2, 180mm Size 2, 180mm Valgus Neck Size 3, 180mm Size 3, 180mm Valgus Neck Size 4, 200mm Size 4, 230mm Size 4, 260mm Range of Sizes The CPT 12/14 Impaction Grafting instruments are compatible with multiple sizes to allow for precise component sizing to meet individual patient needs. Modular Tamps The modular tamping system is designed to simplify the impaction grafting technique by allowing for focus first on distal packing and then proximal reconstruction.

Trial Reduction Ready Tamps Simplifies the technique and reduces steps of the technique by allowing the trial reduction to be conducted directly off of the tamps. Cannulated Packers and Tamps The cannulation helps to ensure proper component position centralizing the neomedullary canal in the femur and maintaining this position through the impaction grafting technique. Depth Indicator Lines The etched depth indicator lines help ensure that the appropriate amount of graft is in place to meet the needs of each individual case.

Product Data B CPT 12/14 Hip Prosthesis A Stem Length B Offset (mm) When Head/Neck Component Selected Is: C Neck Length (mm) When Head/ Neck Component Selected Is: D E Prod. No. Stem Size A/P M/L Standard Offset (mm) (mm) -3.5 0 +3.5 +7 +10.5-3.5 0 +3.5 +7 +10.5 Width Width 00-8114-000-00 0-STD 105 29 32 35 37 40 24 26 28 30 32 7.5 9.0 00-8114-001-00 1-STD 130 31 34 37 39 42 24 26 28 30 32 9.0 10.5 00-8114-002-00 2-STD 130 33 36 38 41 44 24 26 28 30 32 9.0 13.0 00-8114-003-00 3-STD 130 35 37 40 43 46 24 26 28 30 32 9.0 15.5 00-8114-004-00 4-STD 130 35 38 41 44 46 24 26 28 30 32 10.0 17.5 00-8114-005-00 5-STD 130 37 40 43 45 48 24 26 28 30 32 10.0 20.0 C Extended Offset 00-8114-000-10 0-ET 105 34 37 40 42 45 24 26 28 30 32 7.5 9.0 00-8114-001-10 1-ET 130 36 39 42 44 47 24 26 28 30 32 9.0 10.5 00-8114-002-10 2-ET 130 38 41 43 46 49 24 26 28 30 32 9.0 13.0 00-8114-003-10 3-ET 130 40 42 45 48 51 24 26 28 30 32 9.0 15.5 00-8114-004-10 4-ET 130 40 43 46 48 51 24 26 28 30 32 10.0 17.5 00-8114-005-10 5-ET 130 42 45 47 50 53 24 26 28 30 32 10.0 20.0 E D A Extra Extended Offset 00-8114-002-30 2-ET 130 43 46 48 51 54 29 31 33 35 37 9.0 13.0 00-8114-003-30 3-ET 130 45 47 50 53 56 29 31 33 35 37 9.0 15.5 00-8114-004-30 4-ET 130 45 48 51 53 56 29 31 33 35 37 10.0 17.5 00-8114-005-30 5-ET 130 47 50 52 55 58 29 31 33 35 37 10.0 20.0 Small 00-8114-040-00 -Small 85 25 28 31 34 37 21 23 25 27 29 7.0 8.0 00-8114-050-00 Small 95 27 30 33 36 39 22 24 26 28 30 7.5 9.0 Revision - Long 00-8114-002-18 2, 180mm 180 33 36 38 41 44 24 26 28 30 32 9.5 13.0 00-8114-012-18 2, 180mm VN 180 33 36 38 41 44 39 41 43 45 47 9.5 13.0 00-8114-003-18 3, 180mm 180 40 42 45 48 51 24 26 28 30 32 9.5 16.0 00-8114-013-18 3, 180mm VN 180 40 42 45 48 51 39 41 43 45 47 9.5 16.0 00-8114-004-20 4, 200mm 200 40 42 46 49 51 24 26 28 30 32 11.0 16.0 00-8114-004-23 4, 230mm 230 40 42 46 49 51 24 26 28 30 32 11.0 16.0 00-8114-004-26 4, 260mm 260 40 42 46 49 51 24 26 28 30 32 11.0 16.0 CPT Instrument Sets* Prod. No. Description 00-8334-000-01 CPT Extra Small-Size 3 Instrument Set 00-8334-000-02 CPT Primary Instrument Set 00-8334-000-03 CPT Revision Supplementary Instrument set 00-8334-000-04 CPT Impaction Grafting Instrument Set 00-8334-000-05 CPT Extra Small/Small Supplementary Instrument set * For a complete description of instrument sets, refer to the CPT 12/14 Hip System Surgical Techniques. 1. Malchau et al. Prognosis of total hip replacement: update and validation of results from the Swedish National Hip Arthroplasty Registry 1979-1998. Scientific Exhibition: 67th Annual Meeting of the American Academy of Orthopaedic Surgeons; March 15-19, 2000; Orlando, FL, USA. 2. Weidenhielm LRA, Mikhail WEM, Nelissen RGHH, Bauer TW. Cemented collarless (Exeter-CPT) versus cementless collarless (PCA) femoral components: a 2- to 14-year follow-up evaluation. J Arthroplasty. October 1995;10(5):592-597. 3. Yates P, Gobel D, Bannister Gl. Collarless polished tapered stem: clinical and radiological follow-up over 5 years. J Arthroplasty. February 2002;17(2):189-195. 4. Yates P, Gobel D, Bannister Gl. Collarless polished tapered stem: clinical and radiological follow-up over 5 years. J Arthroplasty. February 2002;17(2):189-195. 5. Data on file at Zimmer. 6. Weidenhielm LRA, Mikhail WEM, Nelissen RGHH, Bauer TW. Surgical Technique and Early Results in Revision of a Total Hip Arthroplasty with a Cemented, Collarless, Tapered, Polished Stem, and Contained Morselized Allograft. 97-8114-101-00 5ML Printed in USA 2004, 2006 Zimmer, Inc. Contact your Zimmer representative or visit us at www.zimmer.com