A new non-invasive ultrasonic method for simultaneous measurements of longitudinal and radial arterial wall movements: first in vivo trial.

Similar documents
Estimation of arterial pulse wave velocity with a new improved Tissue Doppler method

(received 23 September 2004; accepted 18 October 2004)

Change in Elasticity Caused by Flow-Mediated Dilation Measured Only for Intima Media Region of Brachial Artery

Coronary artery disease (CAD) risk factors

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

Mechanical Properties and Active Remodeling of Blood Vessels. Systemic Arterial Tree. Elastic Artery Structure

Mechanical Properties and Active Remodeling of Blood Vessels. Blood Vessels

Pulsed Doppler techniques are commonly used

iu22 Liver Shear Wave ElastPQ

On the feasibility of speckle reduction in echocardiography using strain compounding

Original. Stresses and Strains Distributions in Three-Dimension Three-Layer Abdominal Aortic Wall Based on in vivo Ultrasound Imaging

Guide to Small Animal Vascular Imaging using the Vevo 770 Micro-Ultrasound System

Significance of a notch in the otoacoustic emission stimulus spectrum.

Female gender increases stiffness of elastic but not of muscular arteries in type I diabetic patients.

Ten recommendations for Osteoarthritis and Cartilage (OAC) manuscript preparation, common for all types of studies.

Concepts of Imaging and Knobology

Introduction to Biomedical Imaging

Terminology Tissue Appearance

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Diverse Techniques to Detect Arterial Stiffness

Descriptions of NDT Projects Fall 2004 October 31, 2004

The diameter of the common femoral artery in healthy human: Influence of sex, age, and body size

Original Contribution

End-of-life care in oxygen-dependent COPD and cancer: a national population-based study.

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

MR Advance Techniques. Vascular Imaging. Class II

Professions and occupational identities

Ultrasound Knobology

Linear Ultrasonic Wave Propagation in Biological Tissues

Tissue Strain Analytics Virtual Touch Tissue Imaging and Quantification

Optimising your Doppler settings for an accurate PI. Alison McGuinness Mid Yorks Hospitals

Clinical Evaluation of Closed-Loop Administration of Propofol Guided by the NeuroSENSE Monitor in Children

In vitro experiment using porcine artery for evaluation of ultrasonic measurement of arterial luminal surface profile

Ultrasound. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Oct 17th, 2016

Available online at ScienceDirect. Physics Procedia 70 (2015 )

Vector Volume Flow in Arteriovenous Fistulas

Magnetic Resonance Angiography

IS PVR THE RIGHT METRIC FOR RV AFTERLOAD?

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Female sex hormones do not influence arterial wall properties during the normal menstrual cycle

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

Numerical Modelling of Ultrasonic Phased Array Transducers and Their Application

Diagnostic approach to heart disease

Increased mortality after fracture of the surgical neck of the humerus: a case-control study of 253 patients with a 12-year follow-up.

Dimensional quality control of Ti-Ni dental file by optical coordinate metrology and computed tomography

Guidelines, Policies and Statements D5 Statement on Abdominal Scanning

Designing Beam Steering for Accurate Measurement of Intima-Media Thickness at Carotid Sinus

On the physiological location of otoacoustic emissions

Ultrasound Physics & Terminology

GE Healthcare. Vivid i Cardiovascular ultrasound system

Ultrasound Principles cycle Frequency Wavelength Period Velocity

Practical Histology. Cardiovascular System. Dr Narmeen S. Ahmad

Underwater Acoustic Measurements in Megahertz Frequency Range.

Vevo 2100 System Cardio Measurements. Dieter Fuchs, PhD FUJIFILM VisualSonics, Inc.

Medical Review Approaches to the Diagnosis of Liver Fibrosis

Ultrasound Applied Physics

FLT3 mutations in patients with childhood acute lymphoblastic leukemia (ALL)

Physical Principles of Ultrasound

B-Mode measurements protocols:

Lab Activity 25. Blood Vessels & Circulation. Portland Community College BI 232

Goals. Access flow and renal artery stenosis evaluation by Doppler ultrasound. Reimbursement. WHY use of Doppler Ultrasound

Two-Dimensional Ultrasonic Strain Rate Measurement of the Human Heart in Vivo

1 Fundamentals. Basic Definitions and Physics Principles. Fundamentals

Features and Benefits

Ultrasound in Medicine

Case 9799 Stanford type A aortic dissection: US and CT findings

Carotid Abnormalities Coils, Kinks and Tortuosity David Lorelli M.D., RVT, FACS Michigan Vascular Association Conference Saturday, October 20, 2012

DC-6. Diagnostic Ultrasound System

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus. Rapid Cardiac Echo (RCE)

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

Human Systems. Technology - Ultrasounds

Focus on your needs. Ultrasound system HS60 SAMSUNG MEDISON CO., LTD. CT-HS60 V1.0-GI-FT EN

Which method is better to measure arterial stiffness; augmentation index, pulse wave velocity, carotid distensibility? 전북의대내과 김원호

Chapter 14. The Cardiovascular System

The augmentation index (AI) is the ratio of the ejection

Arterial elasticity imaging: comparison of finite-element analysis models with high-resolution ultrasound speckle tracking

Basic of Ultrasound Physics E FAST & Renal Examination. Dr Muhammad Umer Ihsan MBBS,MD, DCH CCPU,DDU1,FACEM

ULTRASOUND BLOOD FLOW IMAGING IN CAROTID ARTERIES BEFORE AND AFTER ENDARTERECTOMY

Puschmann, Andreas; Dickson, Dennis W; Englund, Elisabet; Wszolek, Zbigniew K; Ross, Owen A

SYNCHRONIZED MEASUREMENTS OF MAXIMUM BLOOD FLOW VELOCITIES IN CAROTID, BRACHIAL AND FEMORAL ARTERIES, AND ECG IN HUMAN POSTURE CHANGES

Daily inspiration. Ultrasound system HS70A SAMSUNG MEDISON CO., LTD. Scan code or visit to learn more

Pipeline Technology Conference 2007

CHARACTERIZATION OF ANNULAR ARRAY TRANSDUCER

CONTENTS. Test Number cpd Tanya Reynolds (Nat. Dip. Diag. Rad., B. Tech. Diag. Rad., B. Tech. Ultrasound)

Dual channel photoplethysmography studies of cardio-vascular response to the body position changes

shear wave elastography

The variable risk of colorectal cancer in patients with inflammatory bowel disease.

Cardiovascular ultrasound system

Tissue Doppler Imaging in Congenital Heart Disease

Supplement (videos)

5 Working With Measurements

Imaging of the Basal Cerebral Arteries and Measurement of Blood Velocity in Adults by Using Transcranial Real-Time Color Flow Doppler Sonography

Acknowledgements. iii

Fulfilling the Promise

High resolution ultrasound scanner for skin imaging

Guidelines, Policies and Statements D20 Statement on Peripheral Venous Ultrasound

Deb Coghlan AMS (Vascular and General ) Brisbane, Australia

Transcription:

A new non-invasive ultrasonic method for simultaneous measurements of longitudinal and radial arterial wall movements: first in vivo trial. Persson, Magnus; Rydén Ahlgren, Åsa; Jansson, Tomas; Eriksson, Anders; Persson, Hans W; Lindström, Kjell Published in: Clinical Physiology and Functional Imaging DOI: 1.146/j.1475-97X.23.54.x Published: 23-1-1 Link to publication Citation for published version (APA): Persson, M., Rydén Ahlgren, Å., Jansson, T., Eriksson, A., Persson, H. W., & Lindström, K. (23). A new noninvasive ultrasonic method for simultaneous measurements of longitudinal and radial arterial wall movements: first in vivo trial. Clinical Physiology and Functional Imaging, 23(5), 247-251. DOI: 1.146/j.147597X.23.54.x General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal? L UNDUNI VERS I TY PO Box117 221L und +4646222

Clin Physiol Funct Imaging (23) 23, pp247 251 A new non-invasive ultrasonic method for simultaneous measurements of longitudinal and radial arterial wall movements: first in vivo trial Magnus Persson 1,Åsa Rydén Ahlgren 2, Tomas Jansson 1, Anders Eriksson 1, Hans W. Persson 1 and Kjell Lindström 1 1 Department of Electrical Measurements, Lund University, Lund, Sweden, and 2 Department of Clinical Physiology, Lund University, Malmö University Hospital, Malmö, Sweden Summary Correspondence Magnus Persson, Department of Electrical Measurements, Box 118, Lund University, SE-221 Lund, Sweden E-mail: magnus.persson@elmat.lth.se Accepted for publication Received 25 April 23; accepted 24 June 23 Key words arterial longitudinal movement; arteries; mechanical properties; shear stress; ultrasound; vessel wall During recent years, the radial movement of the arterial wall has been extensively studied, and measurements of the radial movement are now an important tool in cardiovascular research for characterizing the mechanical properties of the arterial wall. In contrast, the longitudinal movement of vessels has gained little or no attention as it has been presumed that this movement is negligible. With modern high-resolution ultrasound, it can, however, be seen that the intima-media complex of the arterial wall moves not only in the radial direction, but also in the longitudinal direction during pulse-wave propagation. This paper describes a new non-invasive ultrasonic method that is able to measure simultaneously two dimensionally arterial vessel wall movements. The method is demonstrated in a limited in vivo trial. Results from the in vivo trial show that, apart from the well-known radial movement, there is a distinct longitudinal movement in the human common carotid artery with, in this case, the intima-media complex moving substantially as compared with the region of the tunica adventitia. Two-dimensional evaluation of the vessel-wall movements, taking not only the radial movement, but also the longitudinal movement into account, may provide novel information of importance in the evaluation of vesselwall function. Introduction Cardiovascular diseases constitute the major cause of morbidity and mortality in the Western World. To increase our knowledge of cardiovascular diseases, it is important to find methods, preferably non-invasive ones, to study very early manifestations of vascular disease. Changes in the mechanical properties of the arteries can be an early manifestation of vascular disease (Nichols & O Rourke, 1998a). Moreover, changes in the mechanical properties of arteries can have important haemodynamic consequences, and these changes are being increasingly recognized as important factors in cardiovascular morbidity and mortality (Nichols & O Rourke, 1998b). During recent years, the radial movement of arteries (the diameter change) has been extensively studied, and this is now widely used in characterization of vesselwall mechanics by measuring pulse-wave velocity (Lehmann, 1996; Eriksson et al., 22) and distension (Hoeks et al., 1985; Lindström et al., 1987). Thus, measurements of the radial movement of arteries are now an established tool in cardiovascular research, forming the basis for estimation of vessel-wall elasticity. The longitudinal movement of vessels, i.e. the movement along the vessel, has gained little or no attention, because previously it was assumed that the longitudinal movement of the arterial vessels during passage of the pulse wave was negligible (Nichols & O Rourke, 1998c). Lawton & Greene (1956) made measurements of the longitudinal movement of the abdominal aorta by using cinematographic observations of beads sutured to the surface of the vessel. The measured longitudinal movement was very small. The results were later confirmed by Patel et al. (1961) on the thoracic aorta. The small movements present were considered to be mainly the result of respiratory movements of the diaphragm. All of these studies were performed on the outer part of the arterial wall. However, recently our group (Persson et al. 22) reported that with modern ultrasound scanners it can be observed that the inner layers of the arterial vessels, the intima-media complex, move not only in the radial direction, but also in the longitudinal direction during pulse-wave propagation (Fig. 1). This observation had recently been observed visually in both the common carotid and the brachial arteries. Two-dimensional evaluation of the vessel-wall movements taking not only the radial movement, but also the longitudinal movement into account might improve the chances of detecting early abnormalities in vessel-wall function. Further, increased knowledge of the 247

248 Ultrasonic measurements of two-dimensional arterial wall movements, M. Persson et al. Figure 1 A schematic figure of a vessel showing the definition of the longitudinal and the radial movements. The vessel was scanned in the longitudinal direction and oriented horizontally in the image. During a scan, the movements longitudinally and one dimension in the radial direction were measured. longitudinal movement itself might provide valuable new and important information in the study and evaluation of vessel-wall function. This paper describes a new ultrasonic method that makes possible simultaneous measurement of longitudinal and radial movements in different positions of the arterial wall noninvasively in vivo. Results from the first in vivo trial on the right common artery are reported. Methods Measurements The longitudinal and radial movements were measured over a limited segment of the arterial wall using B-mode ultrasound. The movement between consecutive frames was estimated from the grey-scale information by a two-dimensional blockmatching technique (Hein & O Brien, 1993). The longitudinal movement is measured in the lateral direction, and the radial movement is measured in the axial direction of the ultrasound image. The ultrasound information was provided by a HDI Ò -5 ultrasonic system (Philips Medical Systems, ATL Ultrasound, Bothell, WA, USA). The system was equipped with a 5-mm 5 12 MHz linear array transducer, L12-5, and run in the Peripheral Vascular/Arterial application. To achieve the best possible spatial and temporal quantification, the area of interest was zoomed and the persistence function was off. These settings allowed a frame rate of 55 Hz and a spatial quantification of 75 lm in each direction. The data was stored in a cineloop as consecutive frames. The acquisition memory of the ultrasound scanner allowed up to 5Æ5 s of data to be collected and transferred to a PC for postprocessing. The cineloops containing prescan-converted data were visualized on the PC in HDILab (Philips Medical Systems), a software designed for offline cineloop analysis. The images were then exported to Matlab Ò (The MathWorks Inc., Natick, MA, USA), where all the image processing was performed. Image processing A region-of-interest (ROI), f(x,y), containing a well-defined point of the vessel wall was chosen in frame n (Fig. 2). The size of the ROI was approximately Æ7 Æ7 mm. The spatial quantification in the ROI was set by the pixel size. To obtain a better movement estimate, the ROI was interpolated by a factor of 1, resulting in a spatial quantification of 7Æ5 lm in each direction. A kernel, g(x,y), of the ROI was selected automatically in the middle of the ROI. The size of the kernel was seven times smaller than the ROI, which resulted in a kernel size of approximately Æ1 Æ1 mm. The kernel was two-dimensionally cross-correlated with the larger ROI in frame n, v y v x v x,y = c n+1 (i,j) c n (i,j) t t Kernel t 1 ROI Figure 2 The movement between two successive frames, v x,y, in the axial and the lateral direction, respectively, was estimated through the difference between the two-dimensional cross-correlations of the kernel in the first frame and the ROIs in the first and the second frame. Next, the ROI was translated the same distance as the estimated movement, and then repeated in the next frame with the ROI in the new position. To obtain a better movement estimate, the ROI was interpolated by a factor of 1 before the cross-correlation.

Ultrasonic measurements of two-dimensional arterial wall movements, M. Persson et al. 249 cði; jþ ¼ XNX i¼1 X NY j¼1 fðx; yþgððx iþ; ðy jþþ; to obtain a reference value and thereafter with the corresponding interpolated region in the succeeding frame n + 1. The difference between the two two-dimensional correlations, c n (i,j) and c n+1 (i,j), measured the movement per frame, v x,y (pixel/ frame), between the two successive frames in the lateral and the axial direction, respectively. The ROI was then translated the same distance as the estimated movement, after which the algorithm was repeated using frames n + 1 and n + 2 with the ROI in the new position. The movements trace in the lateral, t l, and axial, t c, directions was obtained by cumulative summation of the estimated motion v x,y (t). In vivo trial The first in vivo trials were performed on the common carotid artery. The investigated subject was a 45-year-old healthy, normotensive, non-smoking female with no history of cardiovascular disease. The recordings were carried out with the subject in the supine position. The right common carotid artery was scanned in the longitudinal direction, and the vessel was oriented horizontally in the image. Measurements were performed approximately 3 cm proximal to the bifurcation. Care was taken to minimize the pressure of the transducer. Regions of interest were placed at the intima-media complex of both the anterior and the posterior arterial wall, and at the adventitia of the posterior wall (Fig. 3). The ROI at the adventitia was Longitudinal movement (mm) 2 1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Time (s) Figure 4 The longitudinal movement of the intima-media complex in the posterior wall ( ) and the anterior wall (- - -) of the common carotid artery 3 cm proximal to the bifurcation during a cardiac cycle in a healthy 45-year-old female. A positive longitudinal movement corresponds to movement in the same direction as the blood flow. Longitudinal movement (mm) 2 1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Time (s) Figure 5 The longitudinal movement in the intima-media complex ( ) and in the region of the adventitia (- - -) of the posterior wall of the common carotid artery 3 cm proximal to the bifurcation during a cardiac cycle in a healthy 45-year-old female. A positive longitudinal movement corresponds to movement in the same direction as the blood flow. positioned 1Æ3 mm deeper into the vessel wall than the ROI at the intima-media complex of the posterior wall. Results Figure 3 A scan of the common carotid artery. The boxes schematically indicate the positions of the region-of-interest (ROI) at the intimamedia complex at the anterior and the posterior wall (white) and in the adventitial region at the posterior wall (black) during the measurements. The direction of the blood flow is indicated by the arrow. The limited in vivo trial shows wall movements, both longitudinally and radially in the common carotid artery. The longitudinal movement of the intima-media complex was approximately Æ9 mm in both the anterior and the posterior wall (Fig. 4). The longitudinal movement of the region of the tunica adventitia of the posterior wall was approximately Æ1 mm (Fig. 5). In Fig. 6 the movement loops of the

25 Ultrasonic measurements of two-dimensional arterial wall movements, M. Persson et al. Radial movement (mm) Radial movement (mm) (a) (b) 1 8 6.4 2 2 2 2 4 6 8 1 intima-media complex of common carotid artery for the respective wall are shown, and the radial movements are approximately 1 and Æ55 mm in the anterior and the posterior wall, respectively. The well-known distension, the diameter change during the cardiac cycle, is approximately Æ45 mm (Fig. 7). All measurements were performed approximately 3 cm proximal to the bifurcation. Discussion 2 2 4 6 8 1 Longitudinal movement (mm) Figure 6 The movement loop for the intima-media complex in (a) the anterior wall and (b) the posterior wall in the common carotid artery 3 cm proximal to the bifurcation. The rings mark the position of end-diastole. The arrows indicate the direction of the movement. A positive longitudinal movement corresponds to movements in the same direction as the blood flow. A positive radial movement corresponds to expected movements of the distension of the artery. Traditionally, the longitudinal movement of the arteries during the passage of the pulse wave it is considered to be negligible in comparison with the well-known radial movement (the diameter change). Our group (Persson et al., 22) recently reported that, apart from the well-known radial movement, a definite longitudinal movement of the arterial wall can be observed visually in the common carotid artery, as well as in the Diameter (mm) 5 9 5 8 5 7 5 6 5 5 5 4 1 2 3 4 5 6 7 8 Time (s) Figure 7 The change in diameter of the common carotid artery 3 cm proximal to the bifurcation during a cardiac cycle. brachial artery, with especially the intima-media complex moving. The present paper describes a new non-invasive ultrasonic method for simultaneous measurement of longitudinal and radial vessel-wall movements, and reports the first in vivo trial using the method. We found that the investigated human common carotid artery has a distinct longitudinal movement of the intima-media complex of the same magnitude as the radial movement, i.e. there was a considerably larger longitudinal movement than had been presumed earlier. The longitudinal movement was of the same magnitude in both the anterior and the posterior vessel wall (Fig. 4). The method also permits the measurement of longitudinal movement in different regions, i.e. at different depths, of the vessel wall, and we found that the intima-media complex moves much more than the adventitia (Fig. 5), i.e. a shear stress within the arterial wall is present. Our finding that the intima-media complex is moving longitudinally, as well as radially, seems reasonable, because the pulse wave and the blood flow exert force on the vessel wall during the pulse-wave propagation not only in the radial direction, but also as a shear force in the longitudinal direction of the blood flow and the pulse wave. The arterial wall consists of three concentric zones or regions: the tunica intima (the innermost layer), tunica media and tunica adventitia (the outer wall). The tunica intima consists of the vascular endothelium, which is a single layer of cells resting on a thin layer of connective tissue. The tunica media forms the largest part of the arterial wall, and is the principal determinant of the mechanical properties of the vessel (Nichols & O Rourke, 1998c). The tunica adventitia is a region of collagen and some elastin tissue that merges with the surrounding connective tissue. Wall-shear stress is the drag exerted by the pulse wave and flowing blood on the vessel wall. It has been shown in a variety of studies that shear stress is an important determinant of endothelial cell function, among others, influencing the production of vasoactive substances such as nitric oxide (NO)

Ultrasonic measurements of two-dimensional arterial wall movements, M. Persson et al. 251 (Rubanyi et al., 199), prostacycline (Frangos et al., 1985), and endotheline (Malek & Izumo, 1992). Increased knowledge of the longitudinal movement in the arterial wall may provide new information not only on the mechanical properties of arteries, but might also provide new information on the mechanical forces, their type and pattern, acting on the vessel wall information that can be of great relevance in the study and the evaluation of endothelial function. To be able to estimate the movements in vivo, it is important that the scan is very carefully conducted, as the movements of the vessel wall seem to be <1 mm. The prerequisites for a scan are high frame rate, with no persistence between consecutive images, to achieve acceptable temporal resolution. Further, the vessel walls should be at a right angle to the scan head so that the longitudinal and the radial movements can be easily separated. It is essential that the intima-media complex is clearly visible to be able to perform the measurements, and, if possible, to use a well-defined point visible throughout the cineloop. To avoid introducing false movements, it is very important to hold the scan head completely still. We found this difficult, and scan head movements were often present in the recordings. Consequently, it was hard to obtain consecutive cardiac cycles to analyse. Only one cardiac cycle is therefore presented to demonstrate the method in vivo. However, there were several individual cardiac cycles that had essentially the same movement pattern and the same magnitude of the movement. Future in vivo measurements will be improved by using a mechanical transducer holder to minimize the movements of the transducer relative to the patient. In the investigated healthy middle-age female, the longitudinal movement of the intima-media complex of the common carotid artery was of approximately the same magnitude as the radial movement, i.e. considerably larger than what had earlier been presumed. For the posterior wall, the longitudinal movement was even larger than the radial wall movement. In the examined common carotid artery, the whole vessel was moving parallel during a cardiac cycle causing the radial movement, for the two walls, to move in the same direction (Fig. 6). An interesting finding is that in this case the longitudinal movement moved more opposite to the direction of propagation of the pulse wave than with it, and the opposite movement started before the radial movement was at its maximum. Further studies are needed to improve our knowledge of the longitudinal vessel-wall movements and their relevance for vessel-wall characterization and vascular haemodynamics. Conclusion This paper focuses on the longitudinal movement of arteries, and a new unique non-invasive ultrasonic method for simultaneous estimation of the longitudinal and radial movements of arteries in vivo is presented. The longitudinal movement of the arterial wall has until now gained little or no attention, but it might be an important additional factor in the study and evaluation of vessel-wall function. Acknowledgments This study was supported by a grant from the Swedish Foundation for Strategic Research via Cortech (Swedish Universities in Cooperation for New Cardiovascular Technology), and from The Swedish Research Council for Applied Research. References Eriksson A, Greiff E, Loupas T, Persson M, Pesque P. Arterial pulse wave velocity with tissue Doppler imaging. Ultrasound Med Biol (22); 28: 571 58. Frangos JA, Eskin SG, Mctire LV. Flow effects on prostacyclin production by cultured human endothelial cells. Science (1985); 227: 1477 1479. Hein IA, O Brien WDJ. Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review. IEEE Trans Ultrason Ferroelect Freq Contr (1993); 4: 84 12. Hoeks APG, Ruissen CJ, Hick P, Reneman RS. Transcutaneous detection of relative changes in artery diameter. Ultrasound Med Biol (1985); 11: 51 59. Lawton RW, Greene LC. A method for the in situ study of aortic elasticity in the dog. Report No. NADC-MA-563, AMAL, US Naval and Air Development Center (1956). Lehmann ED. Pulse wave velocity as a marker of vascular disease. Lancet (1996); 348: 744. Lindström K, Gennser G, Sindberg-Eriksen P, Benthin M, Dahl P. An improved echo tracker for studies on pulse waves in fetal aorta. Fetal Physiol Measurements (1987): 217 226. Malek A, Izumo, S. Physiological shear stress causes downregulation of endotheline-1 mrna in bovine aortic endothelium. Am J Physiol (1992); 32: C392 C396. Nichols WW, O Rourke MF. Specific disease. In: McDonald s Blood Flow in Arteries (1998a), pp. 42 417. Edward Arnold, London. Nichols WW, O Rourke MF. Wave reflections. In: McDonald s Blood Flow in Arteries (1998b), pp. 23 222. Edward Arnold, London. Nichols WW, O Rourke MF. Properties of the arterial wall: practice. In: McDonald s Blood Flow in Arteries (1998c), pp. 73 97. Edward Arnold, London. Patel DJ, Mallos AJ, Fry DL. Aortic mechanics in the living dog. J Appl Physiol (1961); 16: 293 299. Persson M, Rydén Ahlgren A, Eriksson A, Jansson T, Persson HW, Lindström K. Non-invasive measurement of arterial longitudinal movement. IEEE Ultrasonics Symposium Proceedings (22), 1739 1742. IEEE, New York, NY. Rubanyi GM, Freay AD, Kauser K, Johns A, Harder DR. Mechanoreception by the endothelium: mediators and mechanisms of pressureand flow-induced vascular responses. Blood Vessels (199); 27: 246 257.