Recurrent Unexplained Palpitations (RUP) Study

Similar documents
16033 Lavagna, Italy b Interventional Cardiology Unit, Department of Cardiology, Azienda Ospedaliera Santa Maria

as the cause of recurrent syncope 3 allows appropriate management aimed

Clinical Policy: Holter Monitors Reference Number: CP.MP.113

Remote Monitoring & the Smart Home of the 21 Century

Implantable loop recorders Michele Brignole Arrhythmologic Center, Lavagna, Italy

Ambulatory Cardiac Monitors and Outpatient Telemetry Corporate Medical Policy

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

Value of the implantable loop recorder for the management of patients with unexplained syncope

ACC/AHA Guidelines for Ambulatory Electrocardiography: Executive Summary and Recommendations

La strategia diagnostica: il monitoraggio ecg prolungato. Michele Brignole

ESC Stockholm Arrhythmias & pacing

An Approach to the Patient with Syncope. Guy Amit MD, MPH Soroka University Medical Center Beer-Sheva

Clinical Cardiac Electrophysiology

Mechanism of syncope without prodromes with normal heart and normal electrocardiogram

Management of Syncope in Heart Failure. University of Iowa

Medicare Advantage Medical Policy

The Therapeutic Role of the Implantable Cardioverter Defibrillator in Arrhythmogenic Right Ventricular Dysplasia

AF Today: W. For the majority of patients with atrial. are the Options? Chris Case

CLINICAL CARDIAC ELECTROPHYSIOLOGY Maintenance of Certification (MOC) Examination Blueprint

Arrhythmia Care in the DGH What Still Needs to be Done? Dr. Sundeep Puri Consultant Cardiologist

POWERFUL CARDIAC MONITORING

POLICY PRODUCT VARIATIONS DESCRIPTION/BACKGROUND RATIONALE DEFINITIONS BENEFIT VARIATIONS DISCLAIMER CODING INFORMATION REFERENCES POLICY HISTORY

13/09/2018. The ISSUE Studies. International (Italy & Spain) Study of Syncope of Uncertain Etiology. ISSUE study Pre-defined inclusion cathegories

Improving Patient Outcomes with a Syncope Center. Suneet Mittal, MD

CLINICAL MEDICAL POLICY

Journal of the American College of Cardiology Vol. 37, No. 2, by the American College of Cardiology ISSN /01/$20.

Predictive value of history taking and physical examination in diagnosing arrhythmias in general practice

UTILITY OF THE IMPLANTABLE LOOP RECORDER

Pediatrics. Arrhythmias in Children: Bradycardia and Tachycardia Diagnosis and Treatment. Overview

Asymptomatic patient with WPW

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

2018 ESC SYNCOPE GUIDELINES SUMMARY

Sincopi ricorrenti: diagnosi differenziale e management. Alessandro Proclemer SOC Cardiologia Az. Osp.-Univ. Udine

Arrhythmias and Heart Failure Dr Chris Lang Consultant Cardiologist and Electrophysiologist Royal Infirmary of Edinburgh

The Diagnosis of Cardiac Arrhythmias

Clinical Case 1 A patient with a syncope Panos E. Vardas President Elect of the ESC, Prof of Cardiology, University Hospital of Crete

Cardiac rhythm detailed monitoring by an implanted pacemaker: The iecg solution

Yield of 48-hour Holter monitoring in children with unexplained palpitations and significance of associated symptoms

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Emergency Medical Training Services Emergency Medical Technician Paramedic Program Outlines Outline Topic: WPW Revised: 11/2013

Arrhythmias Focused Review. Who Needs An ICD?

Indications for the use of diagnostic implantable and external ECG loop recorders

Stepwise Evaluation of Unexplained Syncope in a Large Ambulatory Population

MEDICAL POLICY SUBJECT: AMBULATORY EVENT MONITORS

MEDICAL POLICY Cardiac Event Monitors/ Cardiac Event Detection

Introduction. Keywords: Ambulatory electrocardiography, cardiac arrhythmias, syncope

Antony French Consultant Cardiologist & Electrophysiologist

Clinical Results with the Dual-Chamber Cardioverter Defibrillator Phylax AV - Efficacy of the SMART I Discrimination Algorithm

Syncope evaluation: the role of syncope clinics Michele Brignole Arrhythmologic Centre, Lavagna, Italy

PATIENT WITH ARRHYTHMIA IN DENTIST S OFFICE. Małgorzata Kurpesa, MD., PhD. Chair&Department of Cardiology

Cardiac Event Monitors

Dual-Chamber Implantable Cardioverter-Defibrillator

Journal of the American College of Cardiology Vol. 33, No. 7, by the American College of Cardiology ISSN /99/$20.

In patients with syncope, structural heart disease, and a

Successful treatment of tachycardia-induced cardiomyopathy secondary to dual atrioventricular nodal nonreentrant tachycardia using cryoablation

Interactive Simulator for Evaluating the Detection Algorithms of Implantable Defibrillators

Arrhythmia Management Joshua M. Cooper, MD, FHRS, FACC

ECTOPIC BEATS: HOW MANY COUNT?

Automatic External Defibrillators

Efficacy of tilt training in the treatment of neurally mediated syncope. A randomized study

The pill-in-the-pocket strategy for paroxysmal atrial fibrillation

CASE STUDY: THE CLINICAL BENEFIT OF MOBILE CARDIAC OUTPATIENT TELEMETRY. June 22, 2009

Holter monitoring for syncope: diagnostic yield in different patient groups and impact on device implantation

Biatrial Stimulation and the Prevention of Atrial Fibrillation

ICD in a young patient with syncope

Death after Syncope: Can we predict it? Daniel Zamarripa, MD Senior Medical Director December 2013

Cardiac Dysrhythmias and Sports

CURRICULUM GOALS AND OBJECTIVES CLINICAL CARDIOVASCULAR ELECTROPHYSIOLOGY TRAINING PROGRAM. University of Florida Gainesville, Florida

Because of the episodic behavior of syncope, the correlation

Recurrent Implantable Defibrillator Discharges (ICD) Discharges ICD Storm

Repetitive narrow QRS tachycardia in a 61-year-old female patient with recent palpitations

2018 ESC Guidelines for the diagnosis and management of syncope

Seek and Ye Shall Find: Surprising Findings When Using the ILR-LINQ

Implications of mechanism of bradycardia on response to pacing in patients with unexplained syncope

Revisions to the BC Guide for Physicians in Determining Fitness to Drive a Motor Vehicle

Paroxysmal Supraventricular Tachycardia PSVT.

December D. EL ALLAF Centre Hospitalier Hutois, Huy, Belgium. P. ATTUEL Centre Chirurgical Val d'or, Saint Cloud, France

Debate: Asymptomatic Patients with Ventricular Preexcitation Require EP Testing for Risk Stratification. Carlo Pappone, MD, PhD, FACC

Index. cardiology.theclinics.com. Note: Page numbers of article titles are in boldface type.

Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry

Rebuttal. Jerónimo Farré MD 2010

Journal of the American College of Cardiology Vol. 37, No. 7, by the American College of Cardiology ISSN /01/$20.

UNDERSTANDING ELECTROPHYSIOLOGY STUDIES

Clinical and Electrocardiographic Characteristics of Patients with Brugada Syndrome: Report of Five Cases of Documented Ventricular Fibrillation

» A new drug s trial

Patient Resources: Arrhythmias and Congenital Heart Disease

CATHETER ABLATION CODING & REIMBURSEMENT GUIDE. Updated September 2018

November 2016 POWERFULLY SIMPLE CARDIAC MONITORING. SEEQ External Cardiac Monitor (ECM) System. From the leaders who brought you Reveal LINQ ICM

Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry

Topic: Outpatient Cardiac Telemetry Date of Origin: April Section: Medicine Last Reviewed Date: December 2014

Rhythm Control: Is There a Role for the PCP? Blake Norris, MD, FACC BHHI Primary Care Symposium February 28, 2014

Clinical Investigations

Atrial paralysis due to progression of cardiac disease in a patient with Emery-Dreifuss muscular dystrophy

External prolonged electrocardiogram monitoring in unexplained syncope and palpitations: results of the SYNARR-Flash study

Title: Automatic External Defibrillators Division: Medical Management Department: Utilization Management

Ambulatory Event Monitors and Mobile Cardiac Outpatient Telemetry

Wolff-Parkinson-White Syndrome

Summary, conclusions and future perspectives

National Coverage Determination (NCD) for Cardiac Pacemakers (20.8)

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

Transcription:

Journal of the American College of Cardiology Vol. 49, No. 19, 2007 2007 by the American College of Cardiology Foundation ISSN 0735-1097/07/$32.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2007.02.036 Heart Rhythm Disorders Recurrent Unexplained Palpitations (RUP) Study Comparison of Loop Recorder Versus Franco Giada, MD,* Michele Gulizia, MD, Maura Francese, MD, Francesco Croci, MD, Lucio Santangelo, MD, Maurizio Santomauro, MD, Eraldo Occhetta, MD, Carlo Menozzi, MD,# Antonio Raviele, MD* Venice, Catania, Lavagna, Naples, Novara, and Reggio Emilia, Italy Objectives Background Methods Results Conclusions The aim of the study was to compare the diagnostic yield and the costs of implantable loop recorder (ILR) with those of the conventional strategy in patients with unexplained palpitations. In patients with unexplained palpitations, especially in those with infrequent symptoms, the conventional strategy, including short-term ambulatory electrocardiogram (ECG) monitoring and electrophysiological study, sometimes fails to establish a diagnosis. We studied 50 patients with infrequent ( 1 episode/month), sustained ( 1 min) palpitations. Before enrollment, patients had a negative initial evaluation, including history, physical examination, and ECG. Patients were randomized either to conventional strategy (24-h Holter recording, a 4-week period of ambulatory ECG monitoring with an external recorder, and electrophysiological study) or to ILR implantation with 1-year monitoring (n 26). Hospital costs of the 2 strategies were calculated. A diagnosis was obtained in 5 patients in the conventional strategy group, and in 19 subjects in the ILR group (21% vs. 73%, p 0.001). Despite the higher initial cost, the cost per diagnosis in the ILR group was lower than in the conventional strategy group ( 3,056 363 vs. 6,768 6,672, p 0.012). In subjects without severe heart disease and with infrequent palpitations, ILR is a safe and more cost-effective diagnostic approach than conventional strategy. (J Am Coll Cardiol 2007;49:1951 6) 2007 by the American College of Cardiology Foundation Journal Club Selection www.jaccjc.org In subjects with palpitations that remain unexplained after initial evaluation (history, physical examination, and electrocardiogram [ECG]), conventional diagnostic strategy includes short-term ambulatory ECG monitoring by means of 24-h Holter recording and external recorders (ERs), and electrophysiological study (EPS) (1 4). However, despite all these investigations, it is sometimes difficult to establish a diagnosis, especially in patients with infrequent symptoms (4). From the *Cardiovascular Department, Ospedale Umberto I, Mestre-Venice, Venice, Italy; Division of Cardiology, Ospedale S. Luigi-S. Currò, Catania, Italy; Arrhythmologic Unit, Ospedali Riuniti, Lavagna, Italy; Cardiology Department, 2 Naples University, Naples, Italy; Division of Cardiology, Federico II University, Naples, Italy; Division of Cardiology, Ospedale Maggiore della Carità, Novara, Italy; and the #Division of Cardiology, Reggio Emilia, Reggio Emilia, Italy. This study was funded, in part, by Medtronic. Manuscript received November 6, 2006; revised manuscript received January 30, 2007, accepted February 5, 2007. loop recorders (ILRs) could prove useful in the study of palpitations (1), but no data are currently available regarding their diagnostic yield in this setting. The aim of this trial was to compare the diagnostic yield and costs of ILR with those of the conventional strategy, in patients with infrequent unexplained palpitations. Methods Study design. This trial was a multicenter, prospective, randomized study. The primary end point was to establish the cause of the palpitations. Patients were randomized either to conventional strategy or to ILR implantation. Crossover was not mandated by the study protocol, but if conventional strategy did not provide a diagnosis, patients were invited to cross over to ILR. The study was approved by the ethics committee of each center, and all patients gave written, informed consent. Patient eligibility. Consecutive patients referred for palpitations (defined as an unpleasant sensation of the awareness of the heart beat) as their chief complaint underwent an

1952 Giada et al. JACC Vol. 49, No. 19, 2007 Cost-Effectiveness Analysis of Palpitations Management May 15, 2007:1951 6 Abbreviations and Acronyms AF atrial fibrillation AVB atrioventricular block EPS electrophysiological study ER external recorder ICER incremental costeffectiveness ratio ILR implantable loop recorder SB sinus bradycardia SHD structural heart disease ST sinus tachycardia SVT supraventricular tachycardia initial evaluation including history, physical examination, and ECG. Patients also underwent echocardiography in order to exclude severe structural heart disease (SHD), and blood chemistry examinations in order to exclude palpitations of noncardiac origin, according to the criteria of Weber and Kapoor (4). Subjects with evident extrasystolic or anxiety-based palpitations were not enrolled. We excluded patients with severe SHD or hereditary arrhythmogenic syndrome, because of concerns of the potential risk of sudden death during recurrence of palpitations. Patients were enrolled if they had a negative initial evaluation, Resource Consumption and Cost Calculations for Testing Table 1 Resource Consumption and Cost Calculations for Testing no apparent or only mild heart disease (ejection fraction 35%), and sustained ( 1 min), infrequent ( 1 episode/ month), and clinically significant (associated to presyncope, diaphoresis, chest pain, and asthenia) palpitations. strategy. The conventional strategy comprised 24-h Holter recording, a 4-week period of ambulatory ECG monitoring with an ER, and EPS, when the 2 previous examinations yielded negative results, on a day case basis. Monitoring was regarded as diagnostic only when a symptom-rhythm correlation was established during spontaneous palpitations (1,5). Electrophysiological study, performed in accordance with standard procedures, was regarded as diagnostic if it induced any brady- or tachyarrhythmias that were sustained ( 1 min or requiring urgent interruption), and accompanied by reproduction of the spontaneous symptoms (2,6). ILR. Patients underwent ILR implantation (Reveal Plus, Medtronic Inc., Minneapolis, Minnesota) on a day case basis, and were monitored for at least 12 months. loop recorder monitoring was regarded as diagnostic only when a symptom-rhythm correlation was established during spontaneous palpitations resembling the symptoms before enrollment (1,5). loop recorder monitoring was regarded as nondiagnostic when arrhythmias were not associated to any symptoms. Cost assessment. The perspective was that of the hospital. The third payer, patients, and societal costs were not evaluated. For each investigation, the items that were considered are presented in Table 1. The incremental cost-effectiveness ratio (ICER) was calculated as the difference between the total cost of ILR and conventional strategy, divided by the difference in the percentage of diagnoses made between ILR and conventional strategy. To evaluate the economic impact of the various investigations, a sensitivity analysis was performed. Statistical analysis. Differences between strategies were tested by means of Student t test for unpaired data, Wilcoxon rank sum test, and Fisher exact test, as requested. A value of p 0.05 was considered significant. Sample size. In patients with infrequent palpitations, we hypothesised that ILR was superior to conventional strategy, and we estimated a diagnostic yield of 75% and 45%, respectively. The resulting sample size was 25 patients for each group. Results Patient characteristics. Fifty patients with unexplained palpitations were randomized: 24 to the conventional strategy group and 26 to the ILR group. There were no differences in baseline clinical characteristics between groups (Table 2). A diagnosis was obtained in 30 of the 50 patients (60%) (Fig. 1); in 22 of these 30 (73%), a significant arrhythmia was diagnosed (Table 3). No adverse events were observed, and there were no facility visits other than those planned in the study protocol. Primary end point. In the conventional strategy group, a diagnosis was obtained in 5 (21%) patients (mean time to diagnosis 36 26 days). Holter monitoring proved negative Staff Main Equipment and Disposables Electrophysiology Room* Total Cost Holter monitoring Consumption, n 1 physician, 1 nurse 1 recorder, 1 battery, 7 electrodes 0 Cost, 40 3 0 43 External recorder Consumption, n 1 physician, 1 nurse 1 recorder, 15 batteries, 45 electrodes 0 Cost, 53 35 0 88 EPS Consumption, n 1 physician, 1 nurse 2 catheters, 2 introducers, 2 defibrillation pads, 5 electrodes 120 min Cost, 185 1,767 310 2,262 ILR Consumption, n 1 physician, 1 nurse 1 device, 10 electrodes 180 min Cost, 205 1,690 464 2,360 *Including hospital overheads; implantation and removal procedure. EPS electrophysiological study; ILR implantable loop recorder; 2005 Euro.

JACC Vol. 49, No. 19, 2007 May 15, 2007:1951 6 Giada et al. Cost-Effectiveness Analysis of Palpitations Management 1953 Baseline Clinical Characteristics of the Patients Studied Table 2 Baseline Clinical Characteristics of the Patients Studied (n 26) Age, yrs (mean SD) 43 17 51 18 Female gender, n (%) 19 (79) 14 (54) Palpitation episodes in the last year, n (median, IQR) 6 (4 10) 8 (3 10) Length of episodes, min (median, IQR) 40 (5 72) 51 (8 67) Duration of symptoms, months (median, IQR) 30 (15 66) 44 (15 100) Palpitations with associated symptoms, n (%) 24 (100) 26 (100) Presyncope 16 17 Diaphoresis 7 6 Chest pain 5 6 Asthenia 8 10 Abnormal electrocardiogram, n (%) 4 (17) 4 (15) Right bundle branch block 1 2 Abnormalities of ventricular repolarization 3 2 Structural heart disease, n (%) 6 (25) 11 (42) Hypertension 5 7 Valvular heart disease 3 Ischemic heart disease 1 Dilated cardiomyopathy 1 LVEF, % (mean SD) 63 6 60 7 IQR interquartile range; LVEF left ventricular ejection fraction. in all patients. During monitoring with ER (mean duration 40 25 days), atrial fibrillation (AF) was recorded in 1 case and supraventricular tachycardia (SVT) in 1 case, palpitations did not recur in 16 patients, 5 patients failed to activate the device during an episode of palpitations, and there was 1 case of device malfunction. Electrophysiological study induced SVT in 3 cases. Three of the 4 patients with SVT underwent successful ablation of their arrhythmias, while the other 1, together with the patient with AF, received antiarrhythmic drugs. In the ILR group, a diagnosis was obtained in 19 (73%) subjects (mean time to diagnosis 279 228 days). Thus, the diagnostic yield of ILR was significantly higher with respect to conventional strategy (73% vs. 21%, p 0.001). During monitoring (mean duration 321 235 days), ILR recorded SVT in 6 cases (Fig. 2), AF in 4 cases, atrial flutter in 2 Figure 1 Flow Diagram of Diagnostic Outcome

1954 Giada et al. JACC Vol. 49, No. 19, 2007 Cost-Effectiveness Analysis of Palpitations Management May 15, 2007:1951 6 Diagnostic Outcome Table 3 Diagnostic Outcome (n 26) Diagnosis, n (%) 5 (21) 19 (73)* Supraventricular tachycardia 4 6 Atrial fibrillation/atrial flutter 1 6 Sinus tachycardia 0 4 Sinus bradycardia 0 2 Paroxysmal AV block 0 1 No diagnosis, n (%) 19 (79) 7 (27) No palpitation recurrence during monitoring 16 6 Patient error in activating the recorder 5 1 Recorder malfunctioning 1 0 Negative EPS 19 *p 0.001. AV atrioventricular; EPS electrophysiological study. cases, sinus tachycardia (ST) ( 100 beats/min) in 4 cases, sinus bradycardia (SB) ( 40 beats/min) in 2 cases, and paroxysmal atrioventricular block (AVB) in 1 case. Palpitations did not recur in 6 patients; 1 patient failed to activate the device during an episode of palpitations. The automatic detection mode was activated, but no significant arrhythmias were recorded because the memory of the devices was always saturated by inappropriate activations. Of the 6 patients with SVT, 4 underwent successful ablation of their arrhythmias, while the other 2 received antiarrhythmic drugs. Patients with AF or flutter were treated with antiarrhythmic drugs, those with ST received anxiolytic therapy, and those with SB and AVB underwent pacemaker implantation. Costs. The mean cost per patient was significantly higher, while the mean cost per diagnosis was significantly lower in the ILR group than in the conventional strategy group. The ICER for the ILR strategy was 1,576. Sensitivity analysis confirms the results, except for EPS 50% (Table 4). Crossover. Nine of the 19 patients in whom conventional strategy proved negative consented to crossover ILR. A diagnosis was obtained in 6 (67%) (mean time to diagnosis 316 226 days). During monitoring (mean duration 326 236 days), ILR recorded SVT in 1 case, ST in 4 cases, and paroxysmal AVB in 1 case, while symptoms did not recur in 3 patients. The patient with SVT underwent ablation, the 4 subjects with ST received anxiolytic therapy, and the patient with AVB underwent pacemaker implantation. Follow-up. After a diagnosis was reached, patients were followed up for at least 12 months (mean duration 334 210 days). Palpitations were completely eliminated in 22 patients with arrhythmic diagnosis treated with ablation, pacemaker, or drugs, while they were considerably reduced (from a median number of 9 episodes/year before enroll- Figure 2 Supraventricular Tachycardia Recorded From During an Episode of Palpitations

JACC Vol. 49, No. 19, 2007 May 15, 2007:1951 6 Cost of Testing and Sensitivity Analysis Table 4 Cost of Testing and Sensitivity Analysis Cost Per Patient Giada et al. Cost-Effectiveness Analysis of Palpitations Management Cost Per Diagnosis 1955 (n 26) p Value (n 26) p Value ICER Cost of testing, (mean SD) 1,410 1,389 2,233 265 0.001 6,768 6,672 3,056 363 0.012 1,576 Sensitivity analysis, (mean SD) Holter monitoring, 75% 1,399 1,394 2,233 265 0.008 6,716 6,690 3,056 363 0.013 1,596 Holter monitoring, 50% 1,389 1,389 2,233 265 0.007 6,665 6,665 3,056 363 0.014 1,617 External recorder, 75% 1,388 1,399 2,233 265 0.008 6,662 6,713 3,056 363 0.015 1,618 External recorder, 50% 1,366 1,388 2,233 265 0.006 6,556 6,663 3,056 363 0.017 1,660 EPS, 75% 1,253 1,403 2,233 265 0.003 6,014 6,735 3,056 363 0.042 1,876 EPS, 50% 1,065 1,412 2,233 265 0.001 5,110 6,777 3,056 363 0.151 2,237 ICER incremental cost-effectiveness ratio for implantable loop recorder; other abbreviations as in Table 1. ment, to 1.4 episodes/year) in 8 patients with nonarrhythmic diagnosis who received anxiolytic therapy. Discussion Main findings. This study shows that, in patients with infrequent symptoms and without severe SHD, the diagnostic yield of conventional strategy is low, and that ILR is more likely to provide a diagnosis. Moreover, ILR explained the likely nature of palpitations in most of the patients with negative conventional strategy who consented to crossover to prolonged monitoring strategy. Similar observations have been made by Krahn et al. (7,8) on evaluating patients with syncope. In patients with arrhythmic diagnosis, the prescribed treatment completely eliminated symptoms, thus confirming that the assigned diagnoses really represented the cause of palpitations. The ILR yielded more diagnoses than conventional strategy, resulting in greater cost-effectiveness. Moreover, the ICER for the ILR strategy was low in relation to the costs of further investigations, which are necessary when the diagnoses are fewer. However, if only 50% of patients had undergone EPS, a proportion close to common clinical practice, the cost per diagnosis of conventional strategy would no longer have proved significantly higher than that of ILR. These data confirm that EPS constituted the main driver of cost, and that it is not cost-effective in patients without SHD (2). The low diagnostic value of conventional strategy found in our study, however, does not negate the role of conventional diagnostic testing. Indeed, both ILR and conventional strategy have advantages and disadvantages, and may be considered complementary. Our results may be influenced by the infrequency of symptoms, the absence of severe SHD, and the relatively young age of our patients. Indeed, the diagnostic values of ER and EPS mainly depend on the frequency of palpitations and the presence of SHD, respectively (1 3,5,6). Moreover, older patients are frequently unable to use ER properly (3,5,6). Thus, the baseline characteristics of the population are critical to predicting the diagnostic value of the investigations. Minor findings. Most patients with palpitations are found to have premature beats, ST, SVT, and AF, while ventricular tachycardia is much less common, and is typical of patients with severe SHD (3). Our results are in line with the aforementioned observations. Indeed, as patients with extra-systolic palpitations and severe SHD were not enrolled, we found a high prevalence of SVT and AF, but no premature beats or ventricular tachyarrhythmias. However, the fairly high percentage of ST during symptoms in our patients suggests that initial evaluation often fails to individuate patients with anxiety-based palpitations. Many subjects are not able to use ER properly (3,5). Indeed, in this study, 6 of 24 patients (25%) proved unable to use ER correctly, while only 1 of 25 patients (4%) was unable to activate ILR. The inclusion of presumptive diagnostic categories based on the auto-activation feature of the new generation ambulatory ECG recorders could offer the advantage of overcoming the inability of some patients to activate the devices appropriately, further increasing the diagnostic yield of monitoring (9). However, the auto-activation mode did not prove to be useful in the present study. Study limitations. As our study population included a group of highly selected patients, these results cannot be generalized to the entire population with palpitations, particularly those with frequent symptoms, who may benefit from ER, and those with severe SHD, in which EPS plays a much greater diagnostic role. Moreover, in the majority of patients, palpitations are a well-tolerated and benign condition, and initial evaluation is sufficient to yield a diagnosis or to exclude major arrhythmic disorders. Therefore, further investigations should be considered only in patients with SHD and in those with associated symptoms in which palpitations can be due to important arrhythmias, and prove very troublesome (1 4). Given the possible placebo effect of invasive procedures, the open-label structure of the study may be considered a limitation. Indeed, probably as a consequence of a placebo effect of the surgical procedure, the mean time interval to the first palpitation recurrence during monitoring with ILR was higher than expected, taking into account the mean

1956 Giada et al. JACC Vol. 49, No. 19, 2007 Cost-Effectiveness Analysis of Palpitations Management May 15, 2007:1951 6 time interval between each episode of palpitation in the year before ILR implantation (279 vs. 52 days). Conclusions This study demonstrates that, in subjects with infrequent unexplained palpitations and without severe SHD, ILR is a safe and cost-effective diagnostic approach. Thus, ILR may be a useful primary strategy in these patients, and in those who are poorly compliant with other recording devices. In particular, ILR should be offered to patients with persistent symptoms that suggest an arrhythmic cause, when conventional testing fails to yield a diagnosis. Acknowledgments The authors would like to acknowledge the assistance of Marco Vimercati and Irene Colangelo. Reprint requests and correspondence: Dr. Antonio Raviele, Cardiovascular Department, Umberto I Hospital, Via Circonvallazione 50, 30170 Mestre-Venice, Italy. E-mail: araviele@tin.it. REFERENCES 1. Crawford MH, Bernstein SJ, Deedwania PC, et al. ACC/AHA guidelines for ambulatory electrocardiography: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Revise the Guidelines for Ambulatory Electrocardiography). Circulation 1999;100:886 93. 2. Zipes DP, DiMarco JP, Gillette PC, et al. Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol 1995; 26:555 73. 3. Zimetbaum P, Josephson ME. Evaluation of patients with palpitations. N Engl J Med 1998;338:1369 73. 4. Weber BE, Kapoor WH. Evaluations and outcomes of patients with palpitations. Am J Med 1996;100:138 48. 5. Zimetbaum PJ, Josephson ME. The evolving role of ambulatory arrhythmia monitoring in general practice. Ann Intern Med 1999;150: 848 56. 6. Brembilla-Perrot B, Marcon F, Bosser G, et al. Paroxysmal tachycardia in children and teenagers with normal sinus rhythm and without heart disease. Pacing Clin Electrophysiol 2001;24:41 5. 7. Krahn AD, Klein GJ, Yee R, Skanes AC. Randomized assessment of syncope trial: conventional diagnostic testing versus a prolonged monitoring strategy. Circulation 2001;104:46 56. 8. Krahn AD, Klein GJ, Yee R, Hoch JS, Skanes AC. Cost implications of testing strategy in patients with syncope. Randomized assessment of syncope trial. J Am Coll Cardiol 2003;42:495 501. 9. Ermis C, Zhu AX, Pham S, et al. Comparison of automatic and patient-activated arrhythmia recordings by implantable loop recorders in the evaluation of syncope. Am J Cardiol 2003;92:815 9.