Prevent Cancer Foundation Quantitative Imaging Workshop XIII

Similar documents
Premise. Variation in clinical practice results in poorer outcomes and higher costs.

Outcomes in the NLST. Health system infrastructure needs to implement screening

CT Quality Control Manual FAQs

Crowd-Sourcing Quality in Imaging

AAPM Annual Meeting. ACR Accreditation Update in CT

Chapter 6. Hester Gietema Cornelia Schaefer-Prokop Willem Mali Gerard Groenewegen Mathias Prokop. Accepted for publication in Radiology

A Meta-Analysis on repeatability of Magnetic Resonance Elastography of Liver.

MEASUREMENT OF EFFECT SOLID TUMOR EXAMPLES

Radiographic Assessment of Response An Overview of RECIST v1.1

Ultralow Dose Chest CT with MBIR

Imaging Tissue Response to Therapeutic Radiation

Low-dose CT Lung Cancer Screening Guidelines for Pulmonary Nodules Management Version 2

CT Low Dose Lung Cancer Screening. Part I. Journey to LDCT LCS Program

WG-16 Update fmri & QIBA

Performance Evaluation of Ultrasound Systems: Advanced Methods and Applications

X-Ray & CT Physics / Clinical CT

VA PARTNERSHIP Increase ACCESS to LUNG SCREENING

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

BICOE Breast Imaging Center of Excellence. What is it? - Requirements. National Mammography Database. What do you get? ACR Accreditation in:

Copyright 2007 IEEE. Reprinted from 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, April 2007.

Fetal Dose Calculations and Impact on Patient Care

Pulmonary Nodule Volumetric Measurement Variability as a Function of CT Slice Thickness and Nodule Morphology

Standardize and Optimize. Trials and Drug Development

C2 COMPLETION INSTRUCTIONS

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

Imaging Rotation. University of Michigan Department of Radiation Oncology Division of Radiation Physics. Resident:

Lung nodule volumetry: segmentation algorithms within the same software package cannot be used interchangeably

ACR MRI Accreditation: Medical Physicist Role in the Application Process

AAPM Initiatives in Quantitative Imaging

Low Dose CT Lung Screening: What is Technically Required?

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

2014 EXECUTIVE SUMMARY

Mammography Quality Control: A Refresher

Automatic quality control processing for detection of element/channel dropout in ultrasound transducers

and Tobacco-induced Disease Managment

Overview. ACR Accreditation Update in Mammography. New ACR Activities. Requirements Today. What s New For Tomorrow. ACR: Recognized by FDA and CMS

By choosing to view this document, you agree to all provisions of the copyright laws protecting it.

Prepublication Requirements

relieve pressure on the lungs treat symptoms such as shortness of breath and pain determine the cause of excess fluid in the pleural space.

CT Chest HRCT CT Chest WO

Radiation Protection education of Radiology trainees

University of Groningen. Quantitative CT myocardial perfusion Pelgrim, Gert

HI-Res Extremity Sensation 16

Guidelines for the Management of Pulmonary Nodules Detected by Low-dose CT Lung Cancer Screening

Gender differences in CT calcium scoring: A phantom study

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

Imaging Decisions Start Here SM

RECIST 1.1 Criteria Handout. Medical Imaging. ICONplc.com/imaging

Metabolic volume measurement (physics and methods)

Managing Radiation Risk in Pediatric CT Imaging

Children's (Pediatric) Contrast-enhanced Voiding Urosonography

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell

Justification, Optimization and Communication in Pediatric CT Imaging: Recent Improvements and Persistent Challenges Designated Emphasis in Nuclear

An abdominal ultrasound produces a picture of the organs and other structures in the upper abdomen.

Introduction to ROC analysis

Gemstone Spectral Imaging quantifies lesion characteristics for a confident diagnosis

Kish chakrabarti, Ph.D. Senior Physicist CDRH/FDA

relieve pressure on the lungs treat symptoms such as shortness of breath and pain determine the cause of excess fluid in the pleural space.

Current Status of Supplementary Screening With Breast Ultrasound

MR QA/QC for MRgRT. Rick Layman, PhD, DABR Department of Radiology July 13, 2015

Welcome to the RECIST 1.1 Quick Reference

CTA Pulmonary Embolism CTA Chest W (arterial)

Radiologic assessment of response of tumors to treatment. Copyright 2008 TIMC, Matthew A. Barish M.D. All rights reserved. 1

PHYSICS NEEDS IN RADIATION SCIENCES. James Deye, Ph. D. Contractor, NCI Radiation Research Program

Outline. Lifetime Attributable Risk 10 mgy in 100,000 exposed persons (BEIR VII 2006) SPECT/CT and PET/CT Dosimetry

Implementation of a New Tomosynthesis Program: A Physicists Perspective

CTA Chest Pulmonary Embolism & Routine CT Abdomen + Pelvis W CTA Chest W (arterial) & CT Abdomen + Pelvis W (venous)

Washington State Hospital Association Safe Table Webcast 100K Children Campaign Safe Imaging September 15, 2014

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Computer-Aided Volumetry of Pulmonary Nodules Exhibiting Ground-Glass Opacity at MDCT

Debra Pennington, MD Director of Imaging Dell Children s Medical Center

Progress in CT. Jim Green Senior Vice President & General Manager Philips CT

Small Pulmonary Nodules: Our Preliminary Experience in Volumetric Analysis of Doubling Times

Ureteral Stenting and Nephrostomy

Computer-Aided Detection in Screening CT for

Copyright 2009 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 7260, Medical Imaging 2009:

Hi RES Extremity - (04/18/2011) CTDI: ~13 mgy per acquisition Used for evaluation of: Ankle Elbow Hand Wrist Foot /Calcaneous Toes Fingers

Abdominal Ultrasound

Translating Protocols Across Patient Size: Babies to Bariatric

New Horizons in the Imaging of the Lung

Measure #195 (NQF 0507): Radiology: Stenosis Measurement in Carotid Imaging Reports National Quality Strategy Domain: Effective Clinical Care

IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 25, NO. 4, APRIL

ACR Accreditation Toolkit for Validation Site Surveys

(Non-EKG Gated) CTA Thoracic Aorta = CTA Chest

Lung Cancer Screening: Current Status

Overview. ACR Update on FFDM Accreditation. New ACR Activities. QC Today. QC Tomorrow. ACR Breast Imaging Centers of Excellence BICOE

Quantitative Molecular Imaging Using PET/CT to Assess Response to Therapy

Austin Radiological Association BRAIN AMYLOID STUDY (F-18-Florbetapir)

Quality ID #195 (NQF 0507): Radiology: Stenosis Measurement in Carotid Imaging Reports National Quality Strategy Domain: Effective Clinical Care

I. Equipments for external beam radiotherapy

HEALTHCARE AI DEVELOPMENT CYCLE

Routine CT Chest + Abdomen WO

Biases affecting tumor uptake measurements in FDG-PET

Christine Argento, MD Interventional Pulmonology Emory University

Identification of Missed Pulmonary Nodules on Low Dose CT Lung Cancer Screening Studies Using an Automatic Detection System

International Early Lung Cancer Action Program: Screening Protocol PI: Claudia I. Henschke, PhD, MD New York, New York

MRI FAQs. After reading these documents and checking your protocols, you can apply online here:

Morita 3D Accuitomo Scanning Protocol

Transcription:

Status of the Quantitative Imaging Profile Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening Prevent Cancer Foundation Quantitative Imaging Workshop XIII June 13-14, 2016 David S. Gierada, MD Washington University Professor of Radiology QIBA Working Group Co-Chair

QIBA Goal Advance the science and implementation of quantitative imaging in clinical trials and practice Use imaging devices as automated, reproducible measurement systems for specific tasks

QIBA Approach Conduct rigorous assessment of the variability inherent in image-based measurements Determine performance capabilities of specific imaging biomarkers and requirements for achieving them

QIBA Biomarker Committees CT Volumetry FDG-PET PET Amyloid SPECT CT Lung Density fmri MR Elastography Ultrasound Shear Wave Speed Ultrasound Volume Blood Flow

QIBA Collaboration Imaging science experts (physicists, engineers, image processing scientists) Biostatisticians and metrologists Physicians Biologists, chemists Manufacturers Regulators Patient advocates

The QIBA Profile Describes measurement performance achievable and conditions required Claims Specifications Assessment Procedures

QIBA Activities Literature review Groundwork studies Clinical trial data analysis Theoretical analysis and simulations Discussion and expert consensus

CT Volumetry vs. Advantages : Independent of lesion and measurement orientation Independent of selected slice and orientation Sensitive to size change in all directions Reproducible

CT Volumetry Biomarker Committee Profiles Change Measurements in Solid Tumors (Lung 10 mm) Publicly reviewed 2011 (http://qibawiki.rsna.org/images/e/e3/2011_07_28_profile_ct_advanced_disea se_v2_0f.pdf) Updated version in progress, liver lesions being addressed Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening Released for Public Comment 6/2/16-8/1/16 Open at http://qibawiki.rsna.org/index.php/work_product_for_review

Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening Claim 1 Nodule Volume 95% confidence interval = ±(measured volume x 1.96 x CV) Nodule Diameter (mm) Nodule Volume (mm 3 ) Coefficient of Variation (CV) 95% Confidence Interval 6 and < 8 mm 113 and < 268 0.29 ± 57% 8 and < 10 mm 268 and < 524 0.19 ± 37% 10 and < 12 mm 524 and < 905 0.14 ± 27% 12 mm > 905 0.11 ± 22%

Claim 1 Examples Nodule Volume Nodule volume CV 95% CI Corresponding diameter 95% CI (diameter) 150 mm 3 0.29 65-235 mm 3 6.6 mm 5.0-7.6 mm 500 mm 3 0.19 314-686 mm 3 9.8 mm 8.4-11.0 mm 800 mm 3 0.14 580-1020 mm 3 11.5 mm 10.4-12.4 mm Calculator at http://www.accumetra.com/nodulecalculator.html Currently for investigational use only

Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening Claim 2 Change in Nodule Volume (95% confidence) Real if measured %change>2.77xcv1x100 Amount of change ± 1.96 ([Y 1 CV1] 2 + [Y 2 CV2] 2 ) Nodule Diameter (mm) Nodule Volume (mm 3 ) Coefficient of Variation (CV) % Change Required 6 and < 8 mm 113 and < 268 0.29 80% 8 and < 10 mm 268 and < 524 0.19 53% 10 and < 12 mm 524 and < 905 0.14 39% 12 mm > 905 0.11 30%

Claim 2 Examples % Change in Volume Change % Change Min required (2.77xCVx100) Real change? (95% confidence) 524-917 mm 3 (10.0-12.0 mm) 75% (20%) 2.77 x 0.14 x 100= 39% Yes (149-637 mm 3 ) 180-270 mm 3 (7.0-8.0 mm) 50% (14%) 2.77 x 0.29 x 100= 80% Uncertain Calculator at http://www.accumetra.com/nodulecalculator.html Currently for investigational use only

Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening Profile Conditions Solid nodules close to spherical (shortest dimension is at least 60% of longest dimension) Nodule segmented without manual editing Subject handling, acquisition, reconstruction, analysis specifications followed Volume: Zero measurement bias and covariance Change: Measurement system components same at both time points CT scanner meets conformance requirements

Solid, Spherical, Isolated Initial Follow-up T0 T1 T2 Initial Follow-up

Attached, Non-spherical

Subsolid/Ground Glass Semisolid/Mixed

Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening Specifications Subject selection and handling Symptoms, positioning, breath holding Image Data Acquisition kvp, mas, collimation, pitch Image Data Reconstruction Slice thickness and interval, kernel Image analysis Software, reading paradigm

Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening Assessment Procedures CT Equipment ACR and manufacturer guidelines Technologist, Radiologist, Image Analyst ACR guidelines, relevant training Image Analysis Software TBD

QIBA Profile: Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening Post-comment period http://qibawiki.rsna.org/index.php/work_product_for_review Address issues raised and finalize Verify in practice and modify as needed Update with technical improvements Assess clinical value

Acknowledgements Profile Co-Chairs: Sam Armato and Jim Mulshine Claims: Rick Avila, Nancy Obuchowski, David Yankelevitz CT Coordinating Committee and CT Volumetry Biomarker Committee (QIBA wiki) Dan Sullivan, Ed Jackson, and QIBA Leadership RSNA Staff: Fiona Miller, Joe Koudelik, Julie Lisiecki, Susan Weinmann