The Cun Measurement System: an Investigation into its Suitability in Current Practice

Similar documents
Variability in the Precision of Acupoint Location Methods

All WALES LYMPHOEDEMA GUIDANCE:

The Reliable Measurement of Radial Pulse: Gender Differences in Pulse Profiles

Therapy Manual DO NOT PRINT

Set Your World in Motion. Skeleton measurement

Lever system. Rigid bar. Fulcrum. Force (effort) Resistance (load)

Basic human body measurements for technological design. Part 1: Body measurement definitions and landmarks

Radiographic Positioning Summary (Basic Projections RAD 222)

Reliability of Measuring Trunk Motions in Centimeters

Clinical assessment of the relative lengths of the fingers of the human hand

Koryo Hand Acupuncture Therapy

ISPUB.COM. D Adeyemi, O Komolafe, A Abioye INTRODUCTION

RADIOGRAPHY OF THE HAND, FINGERS & THUMB

Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body weight, height, and sex in 178 healthy subjects

Exercise 11. The Appendicular Skeleton

Department of Community Health, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Selangor, Malaysia INTRODUCTION

Hands on Nerve Conduction Studies

ORTHOSCAN MOBILE DI POSITIONING GUIDE

Body Organizations Flashcards

10/12/2010. Upper Extremity. Pectoral (Shoulder) Girdle. Clavicle (collarbone) Skeletal System: Appendicular Skeleton

Introduction to Biomechanical Analysis

BC Alpine Fitness Testing Field Protocols Revised June 2014

Functional Movement Screen (Cook, 2001)

Version February 2016

Office Chair Design: A Systematic Approach of Ergonomic Design Based on the Anthropometric Measurement of Bangladeshi People

Names: Block: Date: Building an Articulated Model of the Hand

E. Copies of the photo Bones gathered from the Battlefield of Big Horn also found on

Country Health SA Medical Imaging

Spinal Biomechanics & Sitting Posture

For convenience values outside the normal range are bolded. Normal values for the specified patient are stated below the tables.

ACUPUNCTURE POINTS STIMULATION WITH ACUPUNCTURE PEN A GENERAL GUIDE TO PAIN RELIEF

Radiographic Procedures 1

Shiatsu Therapy Association of Australia Inc. SHIATSU THERAPY CODE OF PRACTICE

2452 Lincolnway East Goshen, IN Toll Free: Phone:

Proteus XR/f Patient positioning guide

PFT TRAINING. Improve student performance in preparation for the State Physical Fitness Test (PFT).

PoS(ISCC2015)036. The Research and Design of Children's Dental Treatment Machine Based on Ergonomics. Speaker. Yingjun Su1

Title: EZ-IO. Effective Date: January SOG Number: EMS Rescinds:

School Visits Fitness Testing

Higher National Unit Specification. General information for centres. Unit code: F1BE 35

ESI Wellness Program The BioSynchronistics Design. Industrial Stretching Guide

Module Three: Components of Physical Fitness

OPNAVINST G 30 Dec 05

Evidence-Based Examination of the Foot Presented by Alexis Wright, PT, PhD, DPT, FAAOMPT Practice Sessions/Skill Check-offs

Intraosseous Vascular Access. Dr Merl & Dr Veera

WHOLE-BODY CENTER OF MASS LOCATION IN SEATED POSTURES

Post test for O&P 2 Hrs CE. The Exam

CHAPTER 8 LECTURE OUTLINE

CHAPTER III METHODOLOGY

A Comparison of the Immediate Effects of Eccentric Training vs Static Stretch on Hamstring Flexibility in Basketball Players Dr.

S. Dasgupta Siliguri Institute of Technology, Siliguri, India

National Boards Part 4 Technique. Exam Format 5 stations (1 doctor and 1 patient). 2 setups per station (5 minutes) cervical

Injuries to the Extremities

Predicting the Position of the Femoral Head Center

It is recommended that a person break for 5-10 minutes for every hour spent at a workstation.

JMSCR Vol 05 Issue 07 Page July 2017

Evaluation of handles in a maximum screwdriving torque task

Volumetric and Space Requirements of the Offshore Workforce: The Effects of Donning a Survival Suit.

Normative data for adults referred for specialist pain management in Australia

DEVELOPMENT OF ANTHROPOMETRIC CHAIR BASED ON ARM SPAN, KNEE HEIGHT, AND SITTING HEIGHT FOR ELDERLY

Basics of kinetics. Kinesiology RHS 341 Lecture 7 Dr. Einas Al-Eisa

Practicing Traditional Chinese medicine in New Zealand: The views and experiences of Auckland-based TCM practitioners

Overview of the FITNESSGRAM Body Composition Standards

Disclosure. Entrapment Neuropathies - Overview. Common mononeuropathy sites. Definitions. Common mononeuropathy sites. Common mononeuropathy sites

Resources: Ergonomic/Musculoskeletal Hazards in Patient Handling. Sustained and/or Awkward Postures. Contact Stresses or Pressures

Reaction time MATERIALS. - Pencil - Chair - Ruler

Ergonomic Education For Computer Workstations

SOFTBALL UMPIRE FITNESS TESTING PROTOCOLS

Work Environment Physics

SFPD Physical Ability Test (PAT) Instructions and Score Table

Thai Table Massage. SoaringCraneMassage.com. Copyright 2018 Eric Spivack

ELECTROMYOGRAM ANALYSIS OF MUSCLE FUNCTION INTRODUCTION

Makka HO Stretches. Yours in health and prosperity. Frank Panetta. Shiatsu Practitioner

An Investigation of Hand Force Distribution, Hand Posture and Surface Orientation

Functional Movement Test. Deep Squat

Risk of Axillary Nerve Injury in Standard Anterolateral Approach of Shoulder: Cadaveric Study

16 th Annual Primary Care & Sports Medicine Symposium January 29th, 2016

PREEHCO PROJECT ANTHROPOMETRIC AND MOBILITY TESTING PROCEDURES

What is reflexology? physiological benefits general benefits

Ergonomics Product Assessment

Cognitive and Physical Ergonomics of Translation What can we do to make a computer workplace more ergonomic?

Advanced Life Support (ALS) Paramedic. Physical Capacity Testing Protocols Pre-Employment Candidate Pack

Feel Better. Stanford University ADJUSTING YOUR WORKSTATION PROPER ERGONOMIC POSTURE. USEFUL ERGONOMIC TIPS Work Better.

OFFICE ERGONOMICS SELF-ASSESSMENT

Goniometric Reliability in a Clinical Setting

The Evolution of Human s? Objectives. Agenda. Defining Ergonomics. History of Ergonomics. Office Ergonomics Train the Trainer.

Pectoral (Shoulder) Girdle

Courtesy of your source for the best ergonomic office furniture.

Chapter 8. The Pectoral Girdle & Upper Limb

Research Article Surface Projection of Interosseous Foramen of the Leg: Cadaver Study

MSK CT Extremities: Positioning and Reformations

ACUPUNCTURE AND TOUCH PROTOCOL

"Anatomy is the foundation of medicine and should be based on the form of the human body." Hippocrates

NHS Training for Physiotherapy Support Workers. Workbook 11 The articular system

Sensitivity and Specificity of the Minimal Chair Height Standing Ability Test: A Simple and Affordable Fall-Risk Screening Instrument

Stülpa Instructions for dressing retention with tubular bandages

Chapter 10: Flexibility

Section 2 - Body. Suit/Vest/Leotard/Shorts/Pants. Style Options Reinforcement Options Zip Options Measuring Guide

DESIGN OF ERGONOMIC STOOL (DINGKLIK) FOR BATIK CRAFTERS

Instructions. Print out all three tabs of the guide to be used as a reference.

Transcription:

The Measurement System: an Investigation into its Suitability in Current Practice Meaghan Coyle, Mark Aird, DM Cobbin, C Zaslawski This article is based on a paper presented at the Fifth Australasian Acupuncture and Chinese Herbal Medicine Conference held in Sydney in July 1999 Summary The Chinese anatomical inch (cun) measurement system is an essential component of traditional point location methods used in acupuncture. This study used the cun system to investigate any variation between the traditional measurements and the sample means for selected finger measurements, and for the forearm and lower leg lengths obtained from 50 volunteer subjects randomly selected from staff and students of the College of Traditional Chinese Medicine, University of Technology, Sydney. Subjects were seated while the finger and arm measurements were recorded, and were standing for leg measurement. Data were converted to ratios for analysis, with the one cun measurement for the thumb designated as the standard. There were significant differences between the traditional measurements and the sample means for all hand and leg measurements in the sample. The results were generally the same for gender and the age groups studied. The authors conclude that the cun measurement system does not provide accurate estimates for contemporary Australian adults with respect to hand and lower leg measurements nor, to a lesser extent, with respect to measurements of the forearm. Consequently, it is recommended that methods of point location that are less reliant on the cun measurements (such as the proportional method) should be used in preference to the cundependent directional method. Key words Acupuncture, Acupuncture point location, Chinese anatomical inch (). Introduction The need for a standardised system of measurement was recognised by even the earliest civilisations. That developed by the Chinese has been found to date back to 2900 BC, when pieces of jade resembling rulers were used for measurement. These rulers were divided into equal sized increments, with each section measuring approximately 23mm or multiples thereof. It is believed that the 23mm was equivalent to the breadth of the adult thumb joint at the time (1). This was used as the basis for a system of measurement, and it is now known as one Chinese anatomical inch (one cun). The Chinese used the one cun measurement as well as various lengths and breadths of the fingers in order to locate acupuncture points (Figure 1). These reference measurements include: i. the width of the inter-phalangeal joint of the thumb (1 cun) ii. the width of the index and middle finger, measured at the level of the proximal interphalangeal joint of the index finger (1.5 cun) iii. the length of the two distal phalanges of the index finger (2 cun) iv. the width of all four fingers, measured at the level of the proximal inter-phalangeal joint of the index finger (3 cun). Measurements are also defined for other areas of the body. Two such areas examined in this study were the distance between the elbow crease and the wrist crease (12 cun), and the distance between the middle of the patella (with the knee extended) to the lateral extremity of the lateral 1 cun 1.5 cun 3 cun 2 cun 1 cun Figure 1. Diagram to show cun measurements using the fingers. 10

LT1 LF 1.5 LF2 LF3 RT1 RF1.5 RF2 RF3 0 0.5 1 1.5 2 2.5 3 3.5 Figure 2. Comparison of traditional measurements and sample means for the measurements of the hand (L = Left, R = Right, T = Thumb, F = Finger). malleolus (16 cun) (2). These are referred to as traditional measurements. The reference measurements are important when locating acupuncture points that are not situated near anatomical landmarks. Two commonly used methods for acupuncture point location are the proportional and the directional methods. The proportional method divides a distance between two landmarks or reference marks into equal sized sections. The directional method measures from one landmark or reference mark to an acupuncture point, using the cun reference measurements. Examination of the reference measurements themselves and their application was completed in two stages. Firstly, the study compared each subject s hand, arm and leg measurements with the traditional measurements, giving attention to any differences between left and right sides of the body, between the genders, and between three age categories. Secondly, the two and three cun reference measurements of the hand were tested against the forearm and lower leg lengths. These were examined because they are most commonly used to locate points on the limbs. Method The 50 subjects consisted of staff and students from the College of Traditional Chinese Medicine at the University of Technology, Sydney. There were 22 male and 28 female, with a mean age of 29.7 years (SD ± 8.58). They were categorised into groups by age, with 29 being in the 20-30 year age group, 13 in the 31-41 group and 8 in the 42-52 group. The lengths of each of the finger reference measurements and the lengths of the forearm and lower leg were recorded in millimetres for each subject. The measurements of the fingers and the arm were recorded while the subject was seated with the arm straight and that of the lower leg was taken while the subject was standing. The measurements on the fingers were made using calipers and those of the forearm and lower leg were made with a tape-measure. Since the cun reference system is essentially ratio based, data were converted to ratios for analysis. This required the assumption of a standard: the one cun measurement of the thumb was chosen. For example, the measurements for subject number 1 are outlined in Table 1. The conversion of these values into ratio form required each measurement (in mm) to be divided by the thumb measurement (the designated standard one cun measurement). In the example, the left finger 1.5 cun measurement as a ratio was found by dividing 32mm by 17mm giving a ratio value of 1.88; the left finger two cun ratio was found by dividing 43mm by 17mm, giving a ratio of 2.53, and so on. This process was applied to all measurements, with the left thumb being used as the standard for the left side of the body and the right thumb being used for the right side. A similar process was applied to determine the ratio values of the arm and leg with the two and three cun measurements as the standards. The millimetre measurements were used only to convert data to ratios for analysis, and are not referred to elsewhere in the paper. The results reported below refer to ratio measurements. Statistical analyses of the ratio values were completed using t-tests, one way analysis of variance (ANOVA) and Pearson s product moment correlation coefficient. Departmental ethics committee approval was granted. Table 1 FINGER MEASUREMENTS IN mm AND CUN (Example for Subject Number 1) Measurement Left hand Right hand Reference (cun) 1 1.5 2 3 1 1.5 2 3 Subject s hand in mm 17 32 43 58 18 33 45 60 Subject s hand in cun (as a ratio of mm) 1.00 1.88 2.53 3.41 1.00 1.83 2.50 3.33 11

Measurement JUNE 2000 VOL 18 (1) Figure 2. Comparison of traditional measurements and sample means for the measurements of the arm and leg. 0 2 4 6 8 10 12 14 16 18 20 22 Figure 3. Comparison of traditional measurements and sample means for the measurements of the arm and leg (LA = Left arm, RA = Right arm, LA = Left leg, RL = Right leg). Results Figures 2 to 5 summarise the study results. In each figure, the measurements are listed along the y-axis, with L referring to the left side of the body and R referring to the right side of the body. The letter T following indicates that this measurement was taken from the thumb, while F refers to measurements taken from the fingers, similarly A refers to the arm and L to the leg. Following these letters is a number which is the length (in cun) of the measurement. The number of cun is shown along the x-axis. Figure 2 shows the results of the comparison of the sample means and the traditional measurement for each of the measurements of the hand. The sample mean for each of the reference measurements was significantly greater than the traditional measurements (13.16<t<31.85, in each case, p<0.0001). Note that the thumb measurements for the sample mean and the traditional measurements are the same because the thumb measurement was the standard. Figure 3 shows the comparison of the sample mean to the traditional measurements for both arm and leg measurements. A significant difference was found for the leg measurements (-1.32<t<19.93, in each case, p<0.0001) for both left and right legs, while little difference was found between the sample and traditional measurements for either left or right arms (t=0.62, p=0.54 and t= -1.32, p=0.19, respectively). Figure 4 shows the comparison of the sample means and traditional measurements for both the arm and leg when the two cun is designated as the standard. The sample means were significantly less than the traditional measurements for the arms, and significantly greater than the traditional measurements for the legs (-22.38<t<12.11, in each case, p<0.0001). Figure 5 shows the comparison of the traditional measurements to the sample means for arm and leg measurements using the three cun measurement as the standard. In all cases, statistically significant differences were found (-13.54<t<11.70, in each case, p<0.0001) with the sample means being less than the traditional measurements for the arms, and greater than the traditional measurements for the legs. Left vs Right A significant correlation was found between the sample means for both the left and right sides of the body, for the two cun (r = 0.65, p<0.05), the three cun (r = 0.47, p<0.05), the 12 cun (r = 0.78, p<0.05) and the 16 cun measurements (r = 0.76, p<0.05). Gender With one exception, results for men and women did not differ from those for the total sample. The exception was the right arm measurement in men, which was significantly less than the traditional measurement (t = -4.64, p<0.0001). The sample means for the finger measurements were significantly larger than the traditional measurements for both genders, as were the leg measurements (8.46<t<24.67, p<0.0001 for all finger and both leg measurements). One way ANOVA revealed significant differences when comparing the measurements of men and women with each other. In each case the cun ratio measurements of women were found to be proportionally larger than those of men. The differences found are shown in Table 2. Age The sample was subdivided by age into three 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Figure 4. Comparison of traditional measurements and sample means using the 2 cun measurement as standard (LA = Left arm, RA = Right arm, LL = Left leg, RL = Right leg). 12

Table 2 SIGNIFICANT DIFFERENCES IN RESULTS: IMPLICATIONS FOR MEASUREMENT BETWEEN GENDERS Measurement F p Left hand 2 cun F 1,48 = 5.52 0.02 Right hand 2 cun F 1,48 =15.56 0.0003 Left arm 12 cun F 1,48 = 5.88 0.0192 Right arm 12 cun F 1,48 =17.48 0.0001 Left leg 16 cun F 1,48 =15.89 0.0002 Right leg 16 cun F 1,48 =30.57 0.0001 In each case, using the directional method would result in a point location further from the real point for women than for men groups (20-30, 31-41 and 42-52 years) to determine whether age was a factor in the accuracy of the cun measurement system. However, the findings illustrated in Figures 2 to 5 also applied to each of the three age groups (3.96<t<24.10, in each case, p<0.005), with the one exception of the right arm measurement in the 42-52 year age group (t=-2.43, p<0.05). This sole significant finding when comparing the three age groups was that the mean right leg measurement of the 42-52 year group was smaller than that of the other two groups (F 2,47 =4.63, p<0.005). Summary of results The findings indicate that the cun measurement system is not accurate for the contemporary Australian population. The ratio measurements of the hand and leg are consistently greater than the traditional means (with exception of the right arm measurement in men, and the left leg measurement in the third age group studied) when the one cun measurement of the thumb was set as the standard. However, the system is reasonably accurate for the arms with the one cun (thumb) as the standard. When the two and three cun measurements were designated as standards, the measurements were significantly less than the traditional measurements for the arms, and significantly greater than the traditional measurements for the legs. Discussion The results show that the cun measurement system does not accurately represent contemporary measurements for the hand and leg, and as a consequence will not produce accurate point locations when using the directional method. This result may be explained if the measurement on which the system was based (i.e. the standard) was not the one cun measurement of the thumb. Another traditional measurement exists that is also one cun: the distance between the skin creases of the middle phalanx of the middle finger (Figure 1). However a survey of final year acupuncture students conducted as part of this research showed that only three of 30 students surveyed knew the correct location of this measurement, and only two actually used it in clinical practice. While this could have been designated as the standard, there is little value in basing research on a measurement that is rarely used. Alternatively, the two or three cun measurements could have been taken as the standard for comparison with the other hand measurements. However, as is shown in Figures 4 and 5, they produce substantially different measurements for the arms and legs. The only possible conclusion is that the cun measurement system is not an accurate representation of the hand and leg measurements for contemporary Australians. Measurements showed a positive correlation between left and right sides of the body. This was expected, given that the human form is generally symmetrical. An interesting finding to emerge from this study was the significant difference between male and female subjects for the two cun hand measurement and the arm and leg measurements. These are all measurements of length (measuring along one or more bones) rather than breadth (measuring across one or more fingers or bones). The two cun, arm and leg measurements were proportionally greater for women than for men. This could possibly be explained by men having broader hands (rather than longer) if the occupations of the men studied were predominantly manual labourers, but in this study the group was comprised of university students or clinicians. Also, men would have greater measurements if the study was referring to actual measurements (mm), however analysis using ratio values shows that women have proportionally longer measurements for the 2 cun, the arm and the leg. The lack of difference between age groups was expected, because age-related body changes are generally restricted to shortening of the spine (3). This does not affect the limbs, or the cun system. Also, the significant difference found between the traditional measurements and the sample means was found in a group that included only eight 13

subjects. This small number may have produced results that do not truly represent that age group. When the two and three cun measurements of the hand were taken as the standards, the proportional lengths of the arms and legs were altered dramatically. Therefore, in clinical practice, a practitioner using the directional method of point location would tend to overmeasure (measure too far from the reference landmark and pass the acupuncture point) for the arms, or under-measure (not measure far enough from the reference land mark and therefore fall short of the acupuncture point) for the legs. Potentially this could reduce the effectiveness of treatment and introduce an alternative explanation for research outcomes. It is quite possible that errors due to the use of this measurement system could have negated results and conclusions drawn from previous clinical trials of acupuncture. A reason for these differences in body dimensions can be found through reference to anthropometry, which is the measurement of the size and proportions of the human body. Current anthropometric data show a substantial diffrience between the body dimensions of the North American (US) white male, the African American (US) male and the Japanese male (4), and also between the stature of Saudi Arabian males, and those of Canadians, Taiwanese, West Germans, British, Japanese, South Koreans, Thai and Americans (5). This would pose problems in terms of accurate acupuncture point location if, for example, the proportional measurements of the leg were smaller in one population than in another and the hands did not vary accordingly. Using the directional method of point location in this situation would give similar results as when the two and three cun measurements were used as the standard, that is: over-measurement and under-measurement. Conclusions The system of using body measurements for the location of acupuncture points was designed over 2000 years ago on a specific, Chinese, ethnic population. Data suggest that there are significant differences in both the reference and traditional body measurements between various populations. Consequently, the assumption that the cun measurement system is applicable in contemporary Western populations is questionable. While the cun measurement system provides reasonably accurate measurements and distances Figure 4. Comparison of traditional measurements and sample means using the three cun as the standard. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Figure 5. Comparison of traditional measurements and sample means using the 3 cun measurement as standard (LA = Left arm, RA = Right arm, LL = Left leg, RL = Right leg). for the arms when using the one cun (thumb) measurement, it is far from accurate for the measurements of the hands and legs. As a consequence, locating acupuncture points using these measurements will be inaccurate. We recommend that the proportional method of point location be examined in order to test whether its use in preference to the directional method provides greater accuracy when locating acupuncture points. ME Coyle BHSc in Acupuncture M Aird BHSc in Acupuncture DM Cobbin PhD C Zaslawski BAppSc MHlthEd College of Traditional Chinese Medicine Department of Health Sciences University of Technology, Sydney Address for correspondence Meaghan Coyle Department of Health Sciences City Campus, University of Technology, Sydney PO Box 123, Broadway NSW 2007, Australia Email: Meaghan.Coyle@uts.edu.au References 1. Keightley D. A measure of man in early China: in search of the neolithic inch. Chinese Science 1995; 12: 18-40. 2. Rogers C, Rogers C. Point Location and Point Dynamics Manual. Sydney: Acupuncture Colleges (Australia); 1989. 3. Tortora GJ, Grabowski SR. Principles of Anatomy and Physiology. 7th edition. New York: Harper Collins College Publishers; 1993. 4. Diffrient N, Tilley A, Bardajgy J. Humanscale 1/2/3. Massachusetts: The MIT Press; 1973. 5. Al-Haboubi M. Anthropometry for a mix of different populations. Applied Ergonomics 1992; 23(3): 191-6. : Additional Material is available at: www.medical-acupuncture.co.uk/aimintro.htm 14