Integra BraIn MaPPIng

Similar documents
Activated Transponder & Activator Instruction Manual

TECH 2 Dew Point Retrofit Kit

Integra Cranial Stabilization Product Catalogue

Model 380B DNA Synthesizer Version 1.1

THE LOCATOR OVERDENTURE IMPLANT SYSTEM PRODUCT ORDERING INFORMATION AND PRICE LIST

FURNITURE TERMS / POLICIES. TERMS OF FURNITURE SALE [agreement is required with all orders] FURNITURE ORDERS

Instructions for Use Reprocessed Arthroscopic Shavers

STANDARD INDOOR SIGNS INSTRUCTION MANUAL REVISION DATE: PART#:

large qwix Positioning and fixation screws Surgical Technique lower large qwix English PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST and AFRICA ONLY

StrataCooler Cryo Preservation Module and StrataCooler Cryo Lite Preservation Module

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

Integra Flowable Wound Matrix

Integra. Solustaple Standard staple SURGICAL TECHNIQUE. Uni-Clip Compression staple. Products for sale in Europe, Middle-East and Africa only.

KATALYST. Bipolar Radial Head System. Surgical Technique. orthopedics. KATALYST English. PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST and AFRICA ONLY

Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

Integra. surgical technique. Advansys Midfoot Plating System. eng. D.L.P. Dorsal Lisfranc Plate. M.L.P. Medial Lisfranc Plate

Product Catalog. newdeal HALLU -FIX. New ideas for foot surgery

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology

Integra. Because we are committed to limiting uncertainty, we provide a specific design dedicated to Pediatric procedures.

OWNER S MANUAL. Quick Insertion Guide: INSERT EARTIP into ear canal and rotate earpiece backwards & into position CHECK FOR SEAL

AquaJogg Hydro Treadmill

Smarter Thinking. Simpler Design. Z-MAX. Product Catalog

AquaJogg Hydro Treadmill

Quick Start Guide. Congratulations on your journey to better hearing

Smarter Thinking. Simpler Design. TILOBEMAXX TM. Product Catalog

NEPHROCHECK Calibration Verification Kit Package Insert

Quick Start Guide. Congratulations on your journey to better hearing

D. The following factors are of extreme importance to the eventual success of the procedure.

E. SelectTech 5.1 Bench Owner s / Assembly Manual

Integra Jarit Laparoscopic Instruments Product Catalog 2017 Edition

USER S MANUAL QUESTIONS? CAUTION. For a great selection of new CD and MP3 workouts. Visit our website at. or call

EXERTEC FLAT BENCH ETC-2.1. Model ETC-2.1. Retain This Manual for Reference OWNER'S MANUAL IMPEX INC.

Quick Start Guide. Congratulations on your journey to better hearing

APEX 3-Level Dumbbell Rack

Dumbbell Rack IVK 400. Model IVK 400. Retain This Manual for Reference OWNER'S MANUAL

Restoration not just repair

IGS-02 CALF RAISE BENCH. Model IGS-02. Retain This Manual for Reference OWNER'S MANUAL

Instructions for Use Reprocessed 3D Diagnostic Ultrasound Catheters

MARCY DIAMOND ELITE UTILITY BENCH MD-440. Model MD-440. Retain This Manual for Reference OWNER'S MANUAL

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6

INSTALLATION MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.

Fibrlok II 2529 Universal Optical Fiber Splice

Electrical Markets. 3M TM Heat Shrink Tubing Promotion for Construction & Industrial. Heat Shrink Tubing USA. Made in the

Device Preparation (all steps to be performed per standard interventional technique)

Integra. Uni CP Compression Plating System PRODUCTS FOR SALE IN EUROPE, MIDDLE EAST AND AFRICA ONLY

CE Columns and Accessories

OPERATING INSTRUCTIONS. Orascoptic DK

USER S MANUAL QUESTIONS? CAUTION. Visit our website at. new products, prizes, fitness tips, and much more!

E. SelectTech 3.1 Bench Assembly / Owner s Manual

Quick Start Guide. Congratulations on your journey to better hearing

Mixing Degas Vessel (MDV) Mixing Degas Vessel (MDV) EC-1, EC-2, and EC-4 Flip Booklet for Total Eclipse Applications

Sag Shoe Assembly. Instruction Manual # Updated 10/19/2017 Ver. 2.0

USER S MANUAL QUESTIONS? CAUTION. Visit our website at.

Ultra View Manual Rev. 2 Effective 7/05

APEX FLAT BENCH JD 2.1

Fibrlok II 2529 Universal Optical Fiber Splice

LED Strobe Light with Adjusting Magnetic Base Instruction Manual

Advisor FL Circular Mapping Catheter, Sensor Enabled D-AVSE-D10-F20, D-AVSE-DF10-F20, D-AVSE-D10-F15, D-AVSE-DF10-F15. Instructions for Use

Owner s Manual. Customer Service (Option 3) Monday-Friday 6:00am to 5:00pm Pacific OR Support

LET OUR IMAGE ENHANCE YOUR IMAGE. Operating Instructions MedRx Video Portable OtoScope System

Instructions for Use Reprocessed Diagnostic Electrophysiology Catheters

USER S MANUAL CAUTION ACTIVATE YOUR WARRANTY CUSTOMER CARE. Model No. WEBE Serial No.

VeriFit Irritant Smoke Generators for Respirator Fit Testing SENSITIVITY CHECK PROTOCOL. Introduction. Warnings

User Manual RECHARGEABLE KIT. Includes: 1 PLUS+ rechargeable pack 2 PLUS+ batteries 1 wall charger 1 USB cable 3 Classic Tobacco flavor tanks

C200 bands are available in a variety of colors. Visit us at LifeTrakUSA.com

User Bulletin 7500 Fast Precision Plate Holder for MicroAmp Tube Strips

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use.

limited warranty extends only to the original purchaser and is non-transferable.

VISTA400 REMOVABLE FOOT PLATE. Instructions For Use. Step on yellow pedals to close and open legs to go around chairs & ambulate.

MARCY ECLIPSE BE5000 OLYMPIC WIDTH BARBELL BENCH

Mammographic Accreditation Phantom

low ProfIle neuro PlaTIng system

NEPHROCHECK Liquid Control Kit Package Insert

FLAT BENCH SB Model SB Retain This Manual for Reference OWNER'S MANUAL

WARNING To reduce the risk of burns, fire, electric shock, or injury to persons:

Lag Screw Device Intended for symphyseal fracture fixation of the mandible

Integra B: Camino OLM Intracranial Pressure Monitoring Kit SURGICAL TECHNIQUE

Flex-Point HEATED MUSCLE MASSAGER

Hot & Cold Therapy with the Power of Magnets: Elbow Wrap


3.5 mm Locking Attachment Plate

Universal Monitor User s Guide. Insertion Instructions Care and Maintenance Hearing Care Information Warranty

Guidance System Manual

SelectTech 3.1 Bench Assembly / Owner s Manual

AXS Catalyst Distal Access Catheter

Dip Station G

USER S MANUAL CAUTION ACTIVATE YOUR WARRANTY CUSTOMER CARE. Model No. WEBE Serial No.

WhaT s included. gun requires. Gun Connector Kit Gun Liner

Hearit M. user guide. To find your local supplier visit

MANUAL

NS-1104U MAGNETIC-RESISTANCE UPRIGHT BIKE. Model NS-1104U. Retain This Manual for Reference OWNER'S MANUAL

Low Profile Neuro Plating System. Surgical Technique

Contents.

Owner s Manual. General Information Care & Maintenance Warranty Hearing Care Information

MARCY Foldable Bike NS-652. Model NS-652. Retain This Manual for Reference OWNER'S MANUAL IMPEX INC.

Installation and Maintenance Instructions

Transcription:

Integra BraIn MaPPIng Product catalogue Innovations. For Life. brain mapping

Ordering and Warranty Information Pricing: Prices stated in specific written quotations are firm for thirty days from the date given, and are otherwise subject to change without prior notice. Pricing terms stated on written agreements are governed by such agreements. Minimum Order Requirements: Minimum order requirement is 250 (a 20 handling charge will be added to any order under 250). Ordering Procedure: A written purchase order on the customer s form may be requested for purchases of Integra LifeSciences products. Acceptance of Orders: Orders are accepted upon approval by Integra Customer Service. Return Policy: Authorization from customer service must be obtained prior to returning product. Sterile product must be returned in unopened, undamaged cartons, packed to prevent damage. Non-sterile product must be returned in unused saleable condition in original package. Custom or special order products will not be accepted for credit. Credit will be issued for goods returned prior to ninety days from ship date with a 20% restocking charge. This assumes that the product returned is not damaged and can be verified to have not been used or opened. Customer Service Contact Information International +33 (0)4 37 47 59 50 +33 (0)4 37 47 59 25 (Fax) csemea@integra-ls.com Benelux +32 (0)2 257 4130 +32 (0)2 253 2466 (Fax) custsvcbenelux@integra-ls.com France +33 (0) 4 37 47 59 10 +33 (0) 4 37 47 59 29 (Fax) custsvcfrance@integra-ls.com United Kingdom +44 (0) 1264 345 780 +44 (0) 1264 363 782 (Fax) custsvcuk@integra-ls.com Germany +49 (0) 2102 5535 6200 +49 (0)2 102 5536 636 (Fax) custsvcgermany@integra-ls.com Switzerland +41 (0) 2 27 21 23 30 +41 (0) 2 27 21 23 99 (Fax) custsvcsuisse@integra-ls.com Integra Limited Warranty INTEGRA LIFESCIENCES CORPORATION and its wholly owned subsidiaries («INTEGRA») warrant to INTEGRA authorized distributors and the original purchaser only that each new INTEGRA product is free from manufacturing defects in material and workmanship under normal use and service for a period of two (2) years (except as otherwise expressly provided as to accessory items) from the date of delivery by INTEGRA (or its authorized distributor) to the original purchaser, but in no event beyond the expiration date stated on any product labeling. For purposes of products sold by INTEGRA through an authorized distributor of INTEGRA, «original purchaser» shall include the purchaser of INTEGRA products to whom the distributor first sells the product. Surgical instruments are guaranteed to be free from defects in material and workmanship when maintained and cleaned properly and used normally for their intended purpose. Any covered product that is placed by INTEGRA under a lease, rental or installment purchase agreement and that requires repair service during the term of such placement agreement shall be repaired in accordance with the terms of such agreement. If any covered defect occurs during the warranty period or term of such placement agreement, the purchaser or distributor should communicate directly with INTEGRA. If purchaser or distributor seeks to invoke the terms of this warranty, the product must be returned to INTEGRA. The defective product should be returned promptly, properly packaged and postage prepaid. Loss or damage in return shipment to INTEGRA shall be at sender s risk. INTEGRA s sole responsibility under this warranty shall be repair or replacement, at INTEGRA s sole discretion at INTEGRA s expense, subject to the terms of this warranty and applicable agreements. IN NO EVENT SHALL INTEGRA BE LIABLE FOR ANY INCIDENTAL, INDIRECT, CONSEQUENTIAL OR PUNITIVE DAMAGES IN CONNECTION WITH THE ACQUISITION OR USE OF ANY INTEGRA PRODUCT. Further, this warranty shall not apply to, and INTEGRA shall not be responsible for, any loss arising in connection with the purchase or use of any INTEGRA product that has been repaired by anyone other than an authorized INTEGRA service representative or altered in any way so as, in INTEGRA s judgment, to affect its stability or reliability, or which has been subject to misuse, negligence or accident, or which has been used otherwise than in accordance with the instructions furnished by INTEGRA. THIS INTEGRA LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON INTEGRA S PART OR THE PART OF ITS DISTRIBUTORS, AND INTEGRA NEITHER ASSUMES NOR AUTHORIZES ANY REPRESENTATIVE OR OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH INTEGRA S PRODUCTS. INTEGRA DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE OR APPLICATION OR WARRANTY OF QUALITY AS WELL AS ANY EXPRESS OR IMPLIED WARRANTY TO PATIENTS. No warranty or guarantee may be created by any act or statement nor may this Standard Warranty be modified in any way, except as a result of a writing signed by an officer of INTEGRA. These limitations on the creation or modification of this warranty may not be waived or modified orally or by any conduct. IN NO EVENT SHALL INTEGRA AUTHORIZED DISTRIBUTORS BE LIABLE TOWARDS THE ORIGINAL PURCHASER FOR ANY INCIDENTAL, INDIRECT, CONSEQUENTIAL OR PUNITIVE DAMAGES IN CONNECTION WITH THE ACQUISITION OR USE OF ANY INTEGRA PRODUCT. Further, this warranty shall not apply to, and INTEGRA authorized distributors shall not be responsible towards the original purchaser for, any loss, arising in connection with the purchase or use of any INTEGRA product that has been repaired by anyone other than an authorized INTEGRA service representative or altered in any way so as to affect its stability or reliability, or which has been subject to misuse, negligence or accident, or which has been used otherwise than in accordance with the instructions furnished by INTEGRA. THIS INTEGRA DISTRIBUTOR LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES TOWARDS THE ORIGINAL PURCHASER, EXPRESS OR IMPLIED, AND OF ALL OTHER OBLIGATIONS OR LIABILITIES TOWARDS THE ORIGINAL PURCHASER ON INTEGRA AUTHORIZED DISTRIBUTOR S PART. INTEGRA AUTHORISED DISTRIBUTORS DISCLAIM ALL OTHER WARRANTIES TOWARDS THE ORIGINAL PURCHASER, EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE OR APPLICATION OR WARRANTY OF QUALITY AS WELL AS ANY EXPRESS OR IMPLIED WARRANTY TO PATIENTS. www.integra-ls.com

Table of contents Strip Electrodes...1 Cortical Strip Electrode with Cylindrical Connector... 1-2 Dual-Sided Cortical Strip Electrode with Cylindrical Connector...3 Grid Electrodes...4 Cortical Grid Electrode with Cylindrical Connector... 4-7 3D Conformal Grid 8x8...7 Curved Grid Electrode with Cylindrical Connector...8 Curved Dual-Sided Grid Electrode with Cylindrical Connector... 9-10 Epidural Peg Electrodes...11 Sphenoidal Electrodes...12 Electrode Connecting Cables...13 CamLock Connection System...13 Micro Connecting Cable...13 Ojemann Cortical Stimulator...14 Indexes...15 www.integra-ls.com

Strip Electrodes Auragen Cortical Strip Electrode with Cylindrical Connector Auragen cortical strip electrodes are extra thin and flexible to facilitate intracranial placement through a burr hole. The narrow cylindrical connector design simplifies tunneling, using a 14G tunneling needle, and enables quick and secure attachment to the patented connection system. They are available with Auragen contacts. Contacts are dimpled for maximum contact with cortex. 2 Contact Electrode AU1X2P 2 AURAGEN CONTACTS CABLE: ECCFS02 Color coding for better identification 4 Contact Electrode 3 chiffres identification AU1X4P 4 AURAGEN CONTACTS CABLE: ECCFS04 6 Contact Electrode AU1X6P 6 AURAGEN CONTACTS CABLE: ECCFS06 3 chiffres identification 6 Contact Electrode 7,5mm contact spacing AU1X6PM75 6 CONTACTS AURAGEN CABLE: ECCFS06 1 www.integra-ls.com PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST AND AFRICA ONLY.

Strip Electrodes 3 chiffres identification 8 Contact Electrode AU1X8P 8 AURAGEN CONTACTS CABLE: ECCFS08 8 Contact Electrode AU8X1P 8 AURAGEN CONTACTS CABLE: ECCFS08 Color coding for better identification 10 Contact Electrode AU1X10P 10 AURAGEN CONTACTS CABLE: ECCFS10 12 Contact Electrode AU1X12P 12 AURAGEN CONTACTS CABLE: ECCFS12 www.integra-ls.com 2

Strip Electrodes Auragen Dual-Sided Cortical Strip Electrode with Cylindrical Connector 8 Contact Electrode AU1X4PD 8 AURAGEN CONTACTS CABLE: ECCFS08 Contact exposures are shown facing up 12 Contact Electrode AU1X6PD 12 AURAGEN CONTACTS CABLE: ECCFS12 Contact exposures are shown facing up 16 Contact Electrode AU1X8PD2 16 AURAGEN CONTACTS CABLE: ECCFS16 Contact exposures are shown facing up 3 www.integra-ls.com

Grid Electrodes Auragen Cortical Grid Electrode with Cylindrical Connector Auragen grid electrodes are thin and flexible for easier placement and to conform to the curvature of the cortical surface. The narrow cylindrical connector design simplifies tunneling, using a 14G tunneling needle, and enables quick and secure attachment to the patented connection system. They are available with Auragen contacts. Contacts are dimpled for maximum contact with cortex. 8 Contact Electrode AU2X4P1 8 AURAGEN CONTACTS CABLE: ECCFS08 12 Contact Electrode AU2X6P1 12 AURAGEN CONTACTS CABLE: ECCFS12 10 mm 16 Contact Electrode 10 mm AU4X4P1 16 AURAGEN CONTACTS CABLE: ECCFS16 Color coding for better identification 16 Contact Electrode AU2X8P2 16 AURAGEN CONTACTS CABLE: ECCFS16 S 20 Contact Electrode AU4X5P2 20 AURAGEN CONTACTS CABLE: ECCFS20 www.integra-ls.com 4 PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST AND AFRICA ONLY.

Grid Electrodes Auragen Cortical Grid Electrode with Cylindrical Connector (continued) 20 Contact Electrode AU4X5P12 20 AURAGEN CONTACTS CABLE: ECCFS20 Color coding for better identification 24 Contact Electrode AU4X6P2 24 AURAGEN CONTACTS CABLE: ECCFS24 TANTALALUM MARKER 32 Contact Electrode AU4X8P4 32 AURAGEN CONTACTS CABLE: ECCFS32 40 Contact Electrode 10 mm AU5X8P15 40 AURAGEN CONTACTS CABLE: ECCFS48 10 mm 1 9 17 25 33 2 10 18 26 34 3 11 19 27 35 4 12 20 28 36 5 13 21 29 37 6 14 22 30 38 7 15 23 31 39 8 16 24 32 40 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 460 mm 48 Contact Electrode AU6X8P6 48 AURAGEN CONTACTS CABLE: ECCFS48 64 Contact Electrode AU8X8P8 64 AURAGEN CONTACTS CABLE: ECCFS64 5 www.integra-ls.com PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST AND AFRICA ONLY.

Grid Electrodes Auragen Cortical Grid Electrode with Cylindrical Connector (continued) 16 Contact Electrode AU2X8P1 16 auragen CONTACTS CABLE: 17185C16 32 Contact Electrode AU4X8P2 32 auragen CONTACTS CABLE: 17185C32 32 Contact Electrode AU8X4P14 32 auragen CONTACTS CABLE: ECCFS32 Color coding for better identification 48 Contact Electrode AU6X8P3 48 auragen CONTACTS CABLE: 17185C48 www.integra-ls.com 6

Grid Electrodes Auragen Cortical Grid Electrode with Cylindrical Connector (continued) 64 Contact Electrode AU8X8P4 64 AURAGEN CONTACTS CABLE: 17185C64 64 Contact Electrode 4 mm contact spacing AU8X8P4M4 64 AURAGEN CONTACTS CABLE: 17185C64 64 Contact Electrode 7.5 mm contact spacing AU8X8P4M75 64 AURAGEN CONTACTS CABLE: 17185C64 64 Contact Electrode 10 mm AU8X8P4V 64 AURAGEN CONTACTS CABLE: 17185C64 10 mm 63 61 59 57 55 53 51 49 64 62 60 58 56 54 52 50 45 43 41 39 37 35 47 33 48 46 44 42 40 38 36 34 31 29 27 25 23 21 19 17 32 30 28 26 24 22 20 18 15 13 11 9 7 5 3 1 3D Conformal Grid 8x8 64 Contact Electrode AU8X8P14S 64 CONTACTS AURAGEN CABLE: 17185C64 16 14 12 10 8 6 4 2 3D Conformal Grid 8x8 64 Contact Electrode 64 AURAGEN CONTACTS AU8X8P4S CABLE: 17185C64 1 cm 1 9 17 25 33 41 49 57 2 10 18 26 34 42 50 58 1 cm 59 3 11 19 27 35 43 51 60 4 12 20 28 36 44 52 5 13 21 29 37 45 53 61 6 14 22 30 38 46 54 62 7 15 23 31 39 47 55 63 8 16 24 32 40 48 56 64 63 61 59 57 55 53 51 49 64 62 60 58 56 54 52 50 45 43 41 39 37 35 47 33 48 46 44 42 40 38 36 34 31 29 27 25 23 21 19 17 32 30 28 26 24 22 20 18 15 13 11 9 7 5 3 1 16 14 12 10 8 6 4 2 7 www.integra-ls.com PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST AND AFRICA ONLY.

Grid Electrodes Auragen Curved Grid Electrode with Cylindrical Connector 8 Contact Electrode AU4X2P1C 8 auragen CONTACTS CABLE: ECCFS08 12 Contact Electrode AU6X2P1C 12 CONTACTS auragen CABLE: ECCFS12 16 Contact Electrode AU8X2P2C 16 CONTACTS auragen CABLE: ECCFS16 www.integra-ls.com 8

Grid Electrodes Auragen Curved Dual-Sided Grid Electrode with Cylindrical Connector 16 Contact Electrode AU4X2P2CD 16 auragen CONTACTS CABLE: ECCFS16 Contact exposures are shown facing up 24 Contact Electrode AU6X2P2CD 24 auragen CONTACTS CABLE: ECCFS24 Contact exposures are shown facing up 9 www.integra-ls.com

Grid Electrodes Auragen Curved Dual-Sided Grid Electrode with Cylindrical Connector (continued) 32 Contact Electrode AU8X2P2CDL 32 auragen CONTACTS CABLE : 17185C32 Contact exposures are shown facing up 32 Contact Electrode AU8X2P4CD 32 auragen CONTACTS CABLE: ECCFS32 Contact exposures are shown facing up www.integra-ls.com 10

Epidural Peg Electrodes Epidural Peg Electrodes Peg electrodes are typically positioned in a burr hole to enable extradural recording of brain activity. They have platinum contacts and are furnished in several lengths to accommodate various skull thicknesses. A 4.6 mm twist drill is suitable for installation of peg electrodes in the patient. EP3 EP5 EP7 EP9 EP11 EP13 EP15 EP17 EP19 Length (L) 3 mm 5 mm 7 mm 9 mm 11 mm 13 mm 15 mm 17 mm 19 mm EDSCF EEG CONNECTING CABLE for EP- ELECTRODES with female pins Cable 11 www.integra-ls.com

Sphenoidal Electrodes Sphenoidal Electrodes Sphenoidal electrodes provide a less invasive method of recording brain activity in the epilepsy patient. Sphenoidal electrodes are fabricated from platinum materials. Needle Electrode EDSEP SPHENOIDAL electrode with INSERTION needle, platinum Cable EDSCF EEG CONNECTING CABLE for EP- ELECTRODES with female pins www.integra-ls.com 12

Electrode Connecting Cables CamLock Connection System CamLock Connection System provides quick and secure electrode connections (sold non sterile). Connecting cables - 2.4 m 2 pieces with breakaway for safety release or rapid disconnect away from the patient ECCFS02 2 CONTACT CABLE ECCFS04 4 CONTACT CABLE ECCFS06 6 CONTACT CABLE ECCFS08 8 CONTACT CABLE ECCFS10 10 CONTACT CABLE ECCFS12 12 CONTACT CABLE ECCFS16 2x8 CONNECTOR CABLE ECCFS20 2x10 CONNECTOR CABLE ECCFS24 2x12 CONNECTOR CABLE ECCFS32 4x8 CONNECTOR CABLE ECCFS48 6x8 CONNECTOR CABLE ECCFS64 8x8 CONNECTOR CABLE * Break-away (only for ECCFS cables) Connecting cables - cyl conn 16 contacts-2,4 m 17185C16 1x16 CONNECTOR 17185C32 2x16 CONNECTOR 17185C48 3x16 CONNECTOR 17185C64 4x16 CONNECTOR Locked Unlocked Micro Connecting Cable Micro Connector, Female Pins, 2,5 m EDSCF PEG and SPHENOIDAL ELECT CONN CABLE Cable 13 www.integra-ls.com

Ojemann Cortical Stimulator Ojemann Cortical Stimulator Designed in collaboration with Dr. George Ojemann at the University of Washington, the Ojemann Cortical Stimulator is the industry standard for cortical stimulation mapping procedures. This portable, constant current unit has simple, uncomplicated controls and current settings suitable for use in the awake or anesthetized patient. The Ojemann Cortical Stimulator is a compact, battery-powered unit and supplies up to 20 milliamps current (peak to peak). OCS2 OCS2PND OjEMANN CORTICAL STIMULATOR OjEMANN CORTICAL STIMULATOR PROBE 5 mm www.integra-ls.com 14 PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST AND AFRICA ONLY.

Index - Numerical References 17185C16... 13 17185C32... 13 17185C48... 13 17185C64... 13 AU1X2P... 1 AU1X4P... 1 AU1X4PD... 3 AU1X6P... 1 AU1X6PD... 3 AU1X6PM75... 1 AU1X8P... 2 AU1X8PD2... 3 AU1X10P... 2 AU1X12P... 2 AU2X4P1... 4 AU2X6P1... 4 AU2X8P1... 6 AU2X8P2... 4 AU4X2P1C... 8 AU4X2P2CD... 9 AU4X4P1... 4 AU4X5P2... 4 AU4X5P12... 5 AU4X6P2... 5 AU4X8P4... 5 AU4X8P2... 6 AU5X8P15... 5 AU6X2P1C... 8 AU6X2P2CD... 9 AU6X8P3... 6 AU6X8P6... 5 AU8X1P... 2 AU8X2P2C... 8 AU8X2P2CDL... 10 AU8X2P4CD... 10 AU8X4P14... 6 AU8X8P14S... 7 AU8X8P4... 7 AU8X8P4M4... 7 AU8X8P4M75... 7 AU8X8P4S... 7 AU8X8P4V... 7 AU8X8P8... 5 ECCFS02... 13 ECCFS04... 13 ECCFS06... 13 ECCFS08... 13 ECCFS10... 13 ECCFS12... 13 ECCFS16... 13 ECCFS20... 13 ECCFS24... 13 ECCFS32... 13 ECCFS48... 13 ECCFS64... 13 EDSCF...11, 12, 13 EDSEP... 12 EP3... 11 EP5... 11 EP7... 11 EP9... 11 EP11... 11 EP13... 11 EP15... 11 EP17... 11 EP19... 11 OCS2... 14 OCS2PND... 14 15 www.integra-ls.com

Index - Alphabetical 0-9 3D Conformal Grid 8x8... 7 C Cables... 13 Cortical Grid Electrode with Cylindrical Connector...4-7 Cortical Strip Electrode with Cylindrical Connector...1-2 Curved Dual-Sided Grid Electrode with Cylindrical Connector...9-10 Curved Grid Electrode with Cylindrical Connector... 8 D Dual-Sided Cortical Strip Electrode with Cylindrical Connector... 3 E Electrode Connecting Cables... 13 Epidural Peg Electrodes... 11 G Grid Electrodes...4-10 O Ojemann Cortical Stimulator... 14 S Sphenoidal Electrodes... 12 all text and diagrams contained in this catalog are intended as guidelines and are for illustrative purposes only. No information included in this catalog is intended to replace the directions for use packaged with each Integra product. always refer to the appropriate directions for use for complete clinical instructions. For technical and additional clinical information on Integra products, please contact your Integra NeuroSpecialist. auragen, Integra Brain Mapping and the Integra Wave logo are trademarks of Integra lifesciences corporation or its subsidiaries. www.integra-ls.com 16 PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST AND AFRICA ONLY.

v Integra LifeSciences Services (France) SAS Immeuble Séquoia 2 97 allée Alexandre Borodine Parc technologique de la Porte des alpes 69800 Saint Priest FRANCE www.integra-ls.com France / International United Kingdom Benelux Germany Switzerland +33 (0) 437 47 59 00 +44 (0) 1264 345 700 +32 (0) 2 257 41 30 +49 (0) 0800 10 10 755 +41 22 721 23 00 +33 (0) 437 47 59 99 (Fax) +44 (0) 1264 332 113 (Fax) +32 (0) 2 253 24 66 (Fax) +49 (0) 2102 5536 636 (Fax) +41 22 721 23 99 (Fax) 2009 Integra LifeSciences Corporation. All rights reserved. Printed in France. ILS 12-02-001-01-09 PRODUCTS FOR SALE IN EUROPE, MIDDLE-EAST AND AFRICA ONLY.