The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Similar documents
Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

Restoring Straumann implants. with Locator abutments.

Ankylos. Acuris conometric concept. Manual and product catalog

SIMPLANT Guided Surgery delivering restorative-driven implant treatment

Guided surgery manual

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Simplant. Guided Surgery. delivering restorative driven implant treatment

Including product catalog

Legacy Prosthetic Catalog

ENTRY POINT DEPTH CONTROL ANGULATION CONTROL Simplant. The LongStop concept. Depth and angulation control for all implant systems

How something small, can make such a big difference!! Your best choice in overdenture

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

Astra Tech Implant System. Manual and product catalog OsseoSpeed TX Profile

Ankylos. Product Catalog

OT EQUATOR CASTABLE Single Attachment for Overdentures

Acuris conometric concept Retention redefined. Time-saving has never been easier

SwissPlant Prosthetic Catalog. SwissPlant

IMPRESSION PROCEDURES TRAINING MANUAL

Available for CEREC SW, inlab CAD SW, 3Shape, Dental Wings, DWOS Lava Edition, exocad, Open design software. Atlantis. Atlantis Core File.

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

Xive. Product Catalog

Astra Tech Implant System. SmartFix concept. Manual and product catalog Astra Tech Implant System EV

Straight Octagon Abutment for Tissue Level Implant

LOCATOR abutment and collar for VARIOmulti

WE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP. NO SCREWS. NO CEMENT. NO COMPROMISES.

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

Welcome to DENTSPLY Implants

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

SIC invent. SIC P2F Abutment Dr. Galip Gurel From the gingiva shaper to a provisional crown to the final aesthetic restoration

SS Implant System 2013 PROSTHETIC PROCEDURE

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

HEXAGON Implant System

Atlantis. Atlantis Viewer (app) User guide

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

LOCATOR ROOT ATTACHMENT SYSTEM

Simplant. Immediate Smile. featuring Atlantis Abutment, Clinical and laboratory procedures

SimpleLine II Surgical / Prosthesis Manual

OPENING MINDS AND EXPANDING PRACTICE REVENUE OPPORTUNITIES

US Implant System 2013 PROSTHETIC PROCEDURE

Astra Tech Implant System. Attachment-retained restorations. Clinical and laboratory procedures OsseoSpeed TX

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

prosthetic technique manual

NARROW DIAMETER implant

OPENING MINDS AND EXPANDING PRACTICE REVENUE OPPORTUNITIES

Astra Tech Implant System. Manual and product catalog. Guided surgery. Computer guided implant treatment with the Astra Tech Implant System EV

WE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP.

Implant Phase Flow Chart

» For multi-unit restorations -

RePlant System Prosthetic Catalog

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

cement-retained single crowns using cementable abutments

SMARTbase Beauty Done Better

Osteotome inserts kit, angled. Impression tube (open tray) Selection abutment kit / Selection measurement post. Bar base PMMA & Finisher

- RESTORATIVE PRODUCT CATALOG

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

4766 Research Dr. San Antonio, TX insightdentalsystems.com

Opening minds and expanding practice revenue opportunities

Ankylos. Laboratory Manual

Hex-Lock Abutment System. Restorative Manual

STRAUMANN DENTAL IMPLANT SYSTEM RESToRATIVE SELECTION GUIDE

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

TITANIUM BASES CAD/CAM FOR CROWN AND BRIDGE RESTORATIONS CAD/CAM PROSTHETICS ON CAMLOG AND CONELOG IMPLANTS

Quick start Prosthetics

isy indications and techniques

PROSTHETIC EFFICIENCY. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance.

ANKYLOS Planning Components 100. ANKYLOS Implants 102. ANKYLOS Surgical Kits 103. ANKYLOS Surgical Unit, Handpieces 106

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

CAD/CAM SMARTbase Beauty Done Better

Bridge. For more detailed information, please check the Immediate Smile bridge guidelines.

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free

Z5mlc (Locator *) Implants

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

FIXED-HYBRID EMERGENCY! Why Redo When You Can Rescue?

CHECK-UP Determination of Impression type & Method after implant placement

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

Preci Clix Instructions for Ball Retained Overdenture Attachments

Product Information. Straumann Novaloc. A reliable connection that endures.

Prosthodontic Procedure

The intelligent system.

Leading material offering and application range. Straumann CARES CADCAM

CONTENTS PLANNING SURGERY PROSTHETICS MATERIALS 50

Astra Tech Implant System. Manual and product catalog. Repair procedures. Removal and retrieval of screw fragment, abutment and implant

Multi-Unit Abutment Guide

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir

Advanced individual solutions for esthetic prosthetics. new

Bridging the Gap Between Original and Multi-Platform Systems.

Biomimetic PEARL. Product catalogue

The REAL Mini Implant

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

Straumann Mini Implant System Basic Information. Technical Information

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

Preci Clix Instructions for Ball Retained Overdenture Attachments

1 mm 2 mm 3 mm 4 mm 5 mm 6 mm

OD Secure chairside pick-up using existing denture

Conus Concept: A Rewarding Complete Denture Treatment

Type 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES «

Transcription:

The concept Simplicity and versatility for prosthesis fixation

The concept Experience the freedom in prosthesis fixation Simple and secure fixation of implant-supported prostheses is essential for successful restorations, mainly in elderly patients. The self-aligning LOCATOR makes correct placement of overdentures easy in both the maxilla and mandible and in cases with divergent implants. Its low vertical height makes it an ideal solution, even for patients with restricted mobility or limited occlusal space.

Simplicity and safety Self-aligning design fixation with one click Easy alignment of the prosthesis Clicks into the exact position by light pressure on the prosthesis Low overall height room to move even in limited occlusal spaces Low profile retention of the abutment Sufficient space for easy insertion of the prosthesis even with restricted interocclusal clearance Flexible retention compensation for divergence Retention can be customized using colorcodes inserts, the so-called replacement males, that offer a range of retentive holding forces Axial divergences up to 40 between two implants can be compensated with these inserts Secure retention enduring durability of the prosthesis Double retention of the LOCATOR abutment in comparison with conventional attachments for a significantly improved seating of the prosthesis Optimum prosthesis durability and signifi - cantly less wear with the rotatable replace - ment males

Step-by-step Placement of LOCATOR abutments After removal of the gingiva former, select the LOCATOR abutments that match the gingival height. Screw in the abutments with the LOCATOR insert for prosthetic ratchet or the LOCATOR driver (gold-colored end of the three-piece LOCATOR core tool). For secure handling, slide the abutment holder sleeve on the LOCATOR driver. The LOCATOR abutment will snap into the holder sleeve and will be retained in place. Tighten the LOCATOR abutments to 30 Ncm with the insert and the prosthetic ratchet. If the prosthesis is manufactured in the laboratory, an impression of the clinical situation should be made after delivery of the LOCATOR abutments. If an existing prosthesis is adjusted chairside, cement the female component directly into the prosthesis. Measuring the divergence Position the black parallel posts on to the abutments and measure the degree of divergence with the LOCATOR angle measurement guide. If the divergences are 10 or less per implant, the clear, pink or blue replacement male can be used depending on the amount of retention required. If the divergences are 10-20 per implant, use the replacement male in green, orange, red or grey. Adjusting the existing prosthesis chairside Manufacturing a new prosthesis in the laboratory Practice: Position the LOCATOR impression copings with integrated black replacement male on the LOCATOR abutments and make an impression of the complete jaw. Laboratory: Insert the female analog into the impression copings with the black processing inserts in the impression and make a cast from the impression with dental stone (class IV). The impression is then given to the laboratory. Please make sure that the black replacement males remain in the impression copings.

Placement of females and preparation of the prosthesis Position the white block-out spacers on the heads of the LOCATOR abutments. Position females with inte grated black processing insert (part of the male processing package) on the LOCATOR abutments. If necessary, add additional block-out spacers until no gap is visible between the female, block-out spacer and gum. Grind the prosthesis in the region of the subsequent females. Cementing in the females Coat the prosthesis with polymer or cold-cured polymer, position it and fix it until the polymer is cured.* Then remove the prosthesis, remove the black processing replacement males from the females and smooth any sharp edges. * Please follow the directions of the polymer manufacturer. Delivery of replacement males Press the color-coded replacement males selected for the divergence and desired retention force firmly into the females with the specified part of the LOCATOR core tool. The replacement male must be flush with the margin of the female. Delivery of prosthesis Check the retention and insert the prosthesis. Measuring the divergence Position the black parallel posts on the female analogs and measure the degree of divergence with the LOCATOR angle measurement guide. If the divergences are 10 or less per implant, the clear, pink or blue replacement male can be used depending on the amount of retention required. If the divergences are 10 to 20 per implant, use the male in green, orange, red or grey. Manufacturing the prosthesis Position the white block-out spacers on the heads of the LOCATOR female analogs. Position the females with integrated black processing replacement male (part of the male processing package) on the LOCATOR abutments. If necessary, add additional block-out spacers until no gap is visible between the female, block-out spacer and gum. Then, manufacture the prosthesis in accordance with the process for complete dentures. During the fabrication, a processing spacer serves as a place holder for the subsequent female. Send the finished prosthesis to the dental practice for delivery. Practice: Remove the black processing replacement males from the females of the prosthesis supplied by the laboratory. Press the colored replacement males selected by the laboratory for the divergence and desired retention force firmly into the females with the specified part of the LOCATOR tool. The replacement male must be flush with the margin of the female. Delivery of prosthesis Clean and disinfect prosthesis. Tighten the LOCATOR abutments with the prosthetic ratchet and the appropriate LOCATOR insert. Then insert the prosthesis and determine the retention.

Content Male Processing Package: Replacement Male Retention force Max. axial divergence 2 x Female 2 x Block-Out Spacer 2 x Replacement Male clear, strong retention 2 x Replacement Male pink, light retention 2 x Replacement Male blue, extra light retention 5.0 lbs, 2268 g 3.0 lbs, 1361 g 1.5 lbs, 680 g 20 between two implants (10 per implant) Order No. Article 0 lbs, 0 g 45 3347 Male Processing Package Titanium (2 pieces) 45 3348 Male Processing Package Stainless steel (2 pieces) 4.0 lbs, 1814 g 2.0 lbs, 907 g 1.0 lbs, 454 g 40 between two implants (20 per implant) All treatment steps are conducted with the three-piece Core Tool ANKYLOS Insert for Prosthetic Ratchet for Delivering LOCATOR abutments manually Insertion of replacement males Removal of replacement males Note: Use the specified torque insert for final placement of the LOCATOR abutment in the implant. Note: Tighten abutments with a torque of 30 Ncm.

ANKYLOS : Products Scale 1.2:1 GH 2 GH 3 GH 4 GH 5 GH 6 Order no. 3102 2610 3102 2612 3102 2614 3102 2616 3102 2618 Replacement Male 41 (4 pieces) Scale 1.2:1 clear, strong pink, light blue, extra light extended range: gray, zero extended range: green, strong extended range: orange, light extended range: red, extra light Order no. 45 3349 45 3350 45 3351 45 3360 45 3352 45 3353 45 3354 Impression Coping 42 (4 pieces) Male Processing Package (Contents: 2 piece each) Female Analog 44 (4 pieces) D 4 Scale 1.2:1 Titanium 43 Stainless Steel 43 Order no. 45 3355 45 3347 45 3348 45 3356 Black Processing Replacement Male 46 (4 pieces) Block-Out Spacer 47 (20 pieces) Processing Spacer 48 (4 pieces) Abutment Holder Sleeve 50 (4 pieces) Scale 1.2:1 Order no. 45 3358 45 3359 45 3361 45 3341 Core Tool 49 3-piece with Abutment Holder Sleeve ANKYLOS Insert for Prosthetic Ratchet 6 for Angle Measurement Guide 51 Parallel Post 46 (4 pieces) Reduced scale Order no. 45 3340 3103 3635 45 3345 45 3346

DENTSPLY Implants does not waive any right to its trademarks by not using the symbols or. 32670029-USX-1310 2013 DENTSPLY. All rights reserved. About DENTSPLY Implants DENTSPLY Implants offers comprehensive solutions for all phases of implant therapy, including ANKYLOS, ASTRA TECH Implant System and XiVE implant lines, digital technologies, such as ATLANTIS patient-specific CAD/CAM solutions and SIMPLANT guided surgery, SYMBIOS regenerative solutions, and professional and business development programs, such as STEPPS. DENTSPLY Implants creates value for dental professionals and allows for predictable and lasting implant treatment outcomes, resulting in enhanced quality of life for patients. About DENTSPLY International DENTSPLY International Inc. is a leading manufacturer and distributor of dental and other healthcare products. For over 110 years, DENTSPLY s commitment to innovation and professional collaboration has enhanced its portfolio of branded consumables and small equipment. Headquartered in the United States, the Company has global operations with sales in more than 120 countries. Follow DENTSPLY Implants www.dentsplyimplants.com