Contrast-Enhanced Breast Tomosynthesis: Combining the Best of Both Worlds for Better Breast-Cancer Diagnosis

Similar documents
CURRENTLY FDA APPROVED ARE FULL FIELD DIGITAL MAMMOGRAPHY SYSTEMS AND FILM SCREEN STILL BEING USED AT SOME INSTITUTIONS

Breast Tomosynthesis An additional screening tool in the fight against breast cancer

WHAT TO EXPECT. Breast Tomosynthesis An additional screening tool in the fight against breast cancer HOLOGIC. The Women's Health Company

Since its introduction in 2000, digital mammography has become

Digital breast tomosynthesis

A Breast Surgeon s Use of Three Dimensional Specimen Tomosynthesis

Update of Digital Breast Tomosynthesis. Susan Orel Roth, MD

TOMOSYNTHESIS: WORTH ALL THE HYPE?

WHAT TO EXPECT. Genius 3D MAMMOGRAPHY Exam. The most exciting advancement in mammography in over 30 years

3D Mammography. The most exciting advancement in mammography in over 30 years

Breast tomosynthesis reduces radiologist performance variability compared to digital mammography

WHAT TO EXPECT. Genius 3D Mammography Exam. The most exciting advancement in mammography in over 30 years

Financial Disclosures

Digital Breast Tomosynthesis from a first idea to clinical routine

Fundamentals of Breast Tomosynthesis

the one name in cancer care.

Breast positioning system for full field digital mammography and digital breast tomosynthesis system

Breast Tomosynthesis. What is breast tomosynthesis?

Mammography limitations. Clinical performance of digital breast tomosynthesis compared to digital mammography: blinded multi-reader study

Corporate Medical Policy

Volume 14 - Issue 3, Matrix

WHAT TO EXPECT. Genius 3D MAMMOGRAPHY Exam. The most exciting advancement in mammography in over 30 years

8/3/2016. DBT Physics Basic to Advanced: Primer On Tomosynthesis. Tomosynthesis Pedigree

Emerging Techniques in Breast Imaging: Contrast-Enhanced Mammography and Fast MRI

Standard Breast Imaging Modalities. Lilian Wang, M.D. Breast Imaging Section Department of Radiology Northwestern Medicine

Contrast-Enhanced Digital Mammography

EARLY DETECTION: MAMMOGRAPHY AND SONOGRAPHY

Epworth Healthcare Benign Breast Disease Symposium. Sat Nov 12 th 2016

THE DIAGNOSTIC WORKUP: THE TEAM APPROACH

The Radiology Aspects

Breast Cancer Screening and High Risk

#46: DIGITAL TOMOSYNTHESIS: What is the Data Really Showing? TERMS (AKA) WHAT IS TOMOSYNTHESIS? 3/3/2014. Digital breast tomosynthesis =

Image processing mammography applications

Radiation Dosimetry in Digital Breast Tomosynthesis. March, 2015 William J. O Connel, Dr. Ph, Senior Medical Physicist

Pitfalls and Limitations of Breast MRI. Susan Orel Roth, MD Professor of Radiology University of Pennsylvania

Women s Imaging Original Research

Updates in Mammography. Dr. Yang Faridah A. Aziz Department of Biomedical Imaging University Malaya Medical Centre

Mammographic imaging of nonpalpable breast lesions. Malai Muttarak, MD Department of Radiology Chiang Mai University Chiang Mai, Thailand

Mammography. What is Mammography?

Diagnostic Medical Physicist Via Christi Hospitals Wichita, Wichita, KS

Advances in Breast Cancer Diagnosis and Treatment. Heidi Memmel, MD FACS Surgical Director of Caldwell Breast Center September 26, 2015

The Future of Breast MRI Improving Outcomes

Anyone can get breast cancer BREAST MRI BREAST CANCER. The incidence of getting breast cancer is 1:19 in Malaysia

What s New in Breast Imaging. Jennifer A. Harvey, M.D., FACR Professor of Radiology University of Virginia

Digital breast tomosynthesis (DBT) occult breast cancers: clinical, radiological and histopathological features.

BREAST IMAGING and NEW IMAGING MODALITIES- A Surgeons view

Digital Breast Tomosynthesis: A Technological Review

Current Status of Supplementary Screening With Breast Ultrasound

Here are examples of bilateral analog mammograms from the same patient including CC and MLO projections.

Contrast Enhanced Spectral Mammography (CESM) Updates

Breast Imaging & You

Tomosynthesis and breast imaging update. Dr Michael J Michell Consultant Radiologist King's College Hospital NHS Foundation Trust

FDA Executive Summary

Screening Mammography: Who, what, where, when, why and how?

Outline. Digital Breast Tomosynthesis: Update and Pearls for Implementation. Tomosynthesis Dataset: 2D/3D (Hologic Combo Acquisition)

MANAGEMENT OF DENSE BREASTS. Nichole K Ingalls, MD, MPH NW Surgical Specialists September 25, 2015

AN ALGORITHM FOR EARLY BREAST CANCER DETECTION IN MAMMOGRAMS

Breast Tomosynthesis

arxiv: v2 [cs.cv] 8 Mar 2018

Correlation between lesion type and the additional value of digital breast tomosynthesis

CenSSIS Multimode Cancer Imaging via Digital Breast Tomosynthesis

Breast Imaging & You

Supplemental Screening for Dense Breasts. Reagan Leverett, MD, MS

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Armed Forces Institute of Pathology.

Henda s Law. Supplemental screening for women with dense breast tissue and increased risk

Benign Intraparenchymal Scarring in the DBT Era

Why Choose Breast Radiology?

Case Report Tubular Carcinoma of the Breast: Advantages and Limitations of Breast Tomosynthesis

Molecular Breast Imaging: History and Recent Developments

Breast Tomosynthesis

EARLY DETECTION: MAMMOGRAPHY AND SONOGRAPHY

Breast MRI, digital mammography and breast tomosynthesis: Comparison of three methods for early detection of breast cancer

Innovations and Applications of Tomosynthesis. Andrew D. A. Maidment, Ph.D. University of Pennsylvania Department of Radiology

Policy Library Clinical Advantages of Digital Breast Tomosynthesis in Symptomatic Patients

Digital Breast Tomosynthesis in the Diagnostic Environment: A Subjective Side-by-Side Review

Breast asymmetries in mammography: Management

Experience with Tomosynthesis (3-D) Mammography in a Mobile Setting and Current Controversies

DOUG LAKE, MD, MRMD (MRSC) RADIOLOGIST, MCFARLAND CLINIC, PC ADJUNCT CLINICAL ASSISTANT PROFESSOR, DEPARTMENT OF RADIOLOGY, STANFORD HEALTH CARE

now a part of Electronic Mammography Exchange: Improving Patient Callback Rates

TOMOSYNTHESIS. Daniela Bernardi. U.O. Senologia Clinica e Screening mammografico APSS Trento, Italy

1. Screening, Diagnosis and Surgical Management of Breast Cancer

Effect of non- homogeneous breast 3ssue on mean glandular dose assessment in digital breast tomosynthesis

Breast Imaging Update: Old Dog New Tricks

Look differently. Invenia ABUS. Automated Breast Ultrasound

Objectives. Explanation of Radiation Dose Terminology 10/9/2018. What are these lines?

What Does Mammography Follow Up Involve?

Melissa Hartman, DO Women s Health Orlando VA Medical Center

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE

BREAST HEALTH SOLUTIONS. See what others miss.

Can Digital Breast Tomosynthesis(DBT) Perform Better than Standard Digital Mammography Workup in a Breast Cancer Assessment Clinic?

Digital Breast Tomosynthesis

Opportunities and Innovations in Digital Mammography John M. Sandrik, Ph.D. GE Healthcare Milwaukee, WI

8/31/2016 HIDING IN PLAIN SITE, ARCHITECTURAL DISTORTIONS AND BREAST ASYMMETRIES ARCHITECTURAL DISTORTIONS ARCHITECTURAL DISTORTIONS

Improving Reading Time of Digital Breast Tomosynthesis with Concurrent Computer Aided Detection

Screening Mammograms: Questions and Answers

Detailed Program of the second BREAST IMAGING AND INTERVENTIONS PROGRAM am am : Clinician s requirements from breast imaging

Ge elastography cpt codes

B R E A S T I M A G I N G S O L U T I O N S. Selenia Dimensions A Revolution in Breast Imaging

Full ultrasound breast volumes. Faster scans. Streamlined workflow. ACUSON S2000 Automated Breast Volume Scanner. Answers for life.

Transcription:

Contrast-Enhanced Breast Tomosynthesis: Combining the Best of Both Worlds for Better Breast-Cancer Diagnosis T Wu (twu2@partners.org), E Rafferty, R Moore, D Kopans, Massachusetts General Hospital, Boston, MA Lay-language description of paper TU-E-317-4 Tuesday, July 27, 4PM 2004 AAPM Annual Meeting, Pittsburgh, PA Introduction Mammography is currently the most effective breast cancer screening technique. It has been shown by clinical studies that mammography has reduced the mortality by 30~50%. However, mammography is not a perfect technique in that about 30% of breast cancers are missed. A major limit to the sensitivity of conventional mammography is the superimposition of the breast tissue. A mammogram is a two-dimensional (2D) projection image from a three-dimensional breast volume. As a result, the various layers of the breast tissues are superimposed on each other in a single 2D image. For this reason, normal tissue may obscure more deeply buried tumors, making difficult to detect the tumor. Conversely, superimposed normal breast tissues have been known to sometimes produce "false lesions" that appear like a cancerous tumor on a mammogram. This is one reason for the unnecessary call-backs of the patient in 2D mammography. Digital breast tomosynthesis (DBT) is a technique that provides 3D structural information of the breast. By removing the superimposition of breast tissues, DBT potentially can improve the detection and diagnosis of breast cancers, as well as reducing unnecessary call-backs. The diagnostic capability of DBT may be further improved by the use of contrast agent. A contrast agent provides "functional" information of the breast lesion and its usage with 2D digital mammography is being investigated. Digital Breast Tomosynthesis (DBT) DBT is an exciting new development in breast imaging. It yields multiple high-resolution image slices that are located at different depth in a breast volume. As a result, it greatly reduces the problems of superimposed tissue that obscure tumors or create the illusion of cancer. Other researchers have investigated tomosynthesis for applications such as angiography, chest imaging, hand joint imaging and dental imaging. We have conducted the first clinical studies on using tomosynthesis for breast imaging. Our initial clinical studies showed compared with conventional mammography, DBT found more cancers (~16%) by removing the obscuring effects of superimposed normal tissue. It also reduced false-positive patient callbacks (85%) by eliminating fake lesions" that appeared in mammograms caused by the superimposed normal structures projected on a 2D image. Currently, DBT is at the research stage. A 3000-patient DBT screening study is being performed at the Massachusetts General Hospital (MGH). We believe the result will further prove the advantage of DBT. GE has obtained a license from MGH for building clinical DBT units. While

further FDA approval is still needed, there should not be any technological obstacles to the clinical use of DBT. Figure 1. Schematic of a tomosynthesis setup for breast imaging.

A B C Figure 2. Comparison of conventional mammography and breast tomosynthesis: potential of tomosynthesis to improve sensitivity. (A) The MLO-view mammogram of the left breast of a patient. A cancer (arrow) is obscured by superimposed breast tissues. (B) A tomosynthesis slice located 12 mm under the breast surface, which shows normal breast tissue. (C) A tomosynthesis slice located 28 mm under the breast surface that clearly shows the cancer (arrow).

3A

Z = 10 mm Z = 20 mm Z = 30 mm Z = 40 mm 3B

Figure 3. Comparison of conventional mammography and breast tomosynthesis: potential of tomosynthesis to improve specificity. (A) Two mammogram views show a finding with illdefined boundary (marked by arrows) in the left breast of a patient. (B) The finding is not shown in tomosynthesis slices from Z = 10 mm to 40 mm. The patient was called back and additional diagnostic mammograms proved that the finding in her original mammograms was caused by superimposed breast tissues. Contrast-Enhanced Imaging The "functional" information (i.e., the dynamics of tumor blood supply) of a lesion can be yielded by contrast agents. A contrast agent is usually required in breast MRI, which is approved by the FDA for use as a supplemental tool to mammography to help diagnose breast cancer. In the technique, patients get an injection of a gadolinium-based contrast agent that concentrates in abnormal breast tissue and lights up these regions. Although breast MR has very good sensitivity (detecting the abnormalities), its specificity (distinguishing between cancerous and noncancerous findings) is relatively poor, which may lead to unnecessary breast biopsies. In addition, MRI is an expensive exam and takes longer time (>30 minutes) than mammography. Contrast-enhanced digital mammography is being investigated, but it is still a 2D imaging technique compromised by overlapping structures. Combination of DBT and Contrast-Enhancement Our goal is to combine the advantages of DBT and contrast imaging. DBT is a 3D mammography technique while a contrast agent provides physiological information of the findings. Compared with 2D contrast-enhanced digital mammography, the superimposed enhanced breast tissue can be separated by DBT, so the morphology (shape) information of the enhanced lesion can be better characterized. Compared with breast MRI, contrast-enhanced DBT has significantly higher resolution (~0.1mm) than MRI (~1mm) because of the high spatial resolution of the digital detector used in DBT. The tumor can also be segmented from surrounding the tissue in order to measure the dynamic curve of the contrast as done in MR. The current experiments on contrast-enhanced DBT study the capability of DBT in separating superimposed tissues that are enhanced by contrast agent, as well as the change in contrast enhancement over time. The experiments on specimens are different than in vivo imaging because contrast agent is injected and flow in interstitial spaces in the specimen, and the change in contrast enhancement in a specimen is different than that in a patient s breast. Our result shows that DBT can separate superimposed tissues are enhanced by contrast agent and the borders of the enhanced features are much better characterized. The change in contrast enhancement over time (take-up and wash-out of the contrast agent) can also be qualitatively characterized. For in vivo imaging, some practical issues need to be studied such as breast compression, registration of pre- and post-injection images.

Figure 4A

Figure 4B Figure 4. An experiment in contrast-enhanced tomosynthesis was performed using a 52 mm thick mastectomy specimen. The pre-contrast and post-contrast subtraction can be easily performed since the specimen did not move during the injection. (A) The pre-contrast (left) and post-contrast (middle) projections and the subtraction image (right). (B) Pre-contrast (left column) and post-contrast (middle column) tomosynthesis slices, and the subtraction images (right column). The depths of the three slices are 15 mm (1st row), 25 mm (2nd row) and 33 mm (3rd row) respectively. Structures and spaces between tissues in the specimen are enhanced in both projection and reconstruction images, while the reconstruction images separate the enhanced tissues and spaces that are overlapped in projection images.

2 mm 5A Z = 11 mm Z = 15 mm 5B 5C

Figure 5. Magnified field of views (FOVs) (A) A FOV on a projection image after subtraction. (B) A FOV at the same in-plane location on a tomosynthesis slice 11 mm under the specimen surface. (C) A FOV on another tomosynthesis slice 15 mm under the specimen surface. Two features that are enhanced by the contrast agent are marked by circles in (A). The conspicuity of the features is compromised by the overlapping structures that are also enhanced by the contrast agent. The features are better perceived in tomosynthesis slices (B) and (C), with their borders clearly characterized.