PROFEMUR Total Hip System P R O D U C T C A T A L O G

Similar documents
STATURE. Never Compromise. Modular Hip Reconstruction PRODUCT CATALOG. Your stem philosophy. Your neck choice. Your cup preference.

Hip Product Brochure

The Leader in Orthopaedic Innovation

Wright Medical Technology, Inc Airline Road Arlington, TN phone toll-free

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Specifications guide ECHELON. Hip System

9800 Metric Blvd. Austin, Texas

Optimum implant geometry

Optimum implant geometry

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Bone Preservation Stem

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Revision. Hip Stem. Surgical Protocol

S U R G I C A L T E C H N I Q U E

Bone Bangalore

AML Hip System. Design Rationale/ Surgical Technique

Approach Patients with Confidence

Surgical Technique. Hip System

Reaching new heights. Comprehensive. Efficient. Simple.

Approach Patients with Confidence

Optimum implant geometry

PLR. Proximal Loading Revision Hip System

Design Rationale. ECHELON Primary Hip System

Featuring. Technology. Product Rationale

Preoperative Planning. The primary objectives of preoperative planning are to:

Answer. Hip System Design Features:

Clinical Evaluation Surgical Technique

Cementless Tapered Femoral Stem Surgical technique

Ovation Hip System. Surgical Technique

One system for all revision types

Profemur TL Classic. Hip System: Classic Stems SURGICAL TECHNIQUE

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

HELIOS h i p s y s t e m

Cementless Tapered Femoral Stem Surgical technique

Inspiring people, Enriching lives

ZMR CROSSOVER INSTRUMENTS AND SURGICAL TECHNIQUE. Surgical Technique for Revision Hip Arthroplasty

*smith&nephew SL-PLUS Cementless Femoral Hip System. Product Information

Following a tradition of success. VerSys Heritage Primary Hip Prosthesis Surgical Technique

MetaFix. Cementless Total Hip Replacement Surgical technique

LPS SYSTEM POCKET GUIDE

ZMR Crossover Instruments. Abbreviated Surgical Technique

HIP SYSTEM SURGICAL TECHNIQUE

Progeny Hip Stem. Surgical Protocol and Product Specifications

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

operative technique Kent Hip

RECLAIM REVISION HIP SYSTEM

Arcos Modular Femoral Revision System

Surgical Technique r5.indd 1 12/8/10 10:36 AM

Integral 180 Surgical Technique

Wright Medical Italy Srl Via Liguria Peschiera Borromeo (MI) - Italy Tel: Fax:

21st Century Fracture Management ETS. Surgical Protocol

Product Rationale. Where Strength and Modularity Connect

28 Surgical Technique

Comprehensive. Simple. Efficient.

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

THE P.F.C. SIGMA FEMORAL ADAPTER. Surgical Technique

Metha Short Hip Stem System

Arcos Modular Femoral Revision System. Broach and Calcar Proximal Bodies Surgical Technique

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

SURGICAL TECHNIQUE. Entrada Hip Stem

Restoration Modular Revision Hip System. Choice Matters

ACETABULAR CUP SURGICAL TECHNIQUE

VERSYS HERITAGE REVISION HIP PROSTHESIS. Surgical Technique for Revision Hip Arthroplasty

Approach Patients with CONFIDENCE

Profemur R. Surgical Technique SURGICAL TECHNIQUE

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

TaperFill. Surgical Technique

Continuing the Tradition. VerSys Heritage Hip System

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

Absolut TM Cemented Stem. Surgical Technique

Surgical technique MkII instrumentation

Section of Modular Hip Prostheses cemented. TMC-3 Modular Hip Prosthesis, cemented. TMC-3 Modular Hüftprothese, zementiert

RESTORATION MODULAR. Surgical Protocol REVISION HIP SYSTEM

Restoration Modular. Revision Hip System Surgical Protocol

EXACTECH HIP. Operative Technique. Tapered and Splined Press-Fit Stems. Cemented Femoral Stems. Renewing Innovations. Enduring Solutions.

Versys Advocate V-Lign and Non V-Lign Cemented Hip Prosthesis

RESTORATION MODULAR. Surgical Protocol REVISION HIP SYSTEM

Manza Cup HA SURGICAL TECHNIQUE.

CPCS. Training Manual. Collarless Polished Cemented Stem

RESTORATION MODULAR. Surgical Protocol REVISION HIP SYSTEM

Surgical Technique. Unisyn Hip System

DUAL MOBILITY CUP, CEMENTED OR CEMENTLESS

UTF Stem. reduced. Surgical Protocol

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

FLH /11

Hype Femoral stems. Surgical technique

ZMR Porous Revision Hip Prosthesis. Surgical Technique IMAGE TO COME

M-SERIES. Modular Femoral Stem AN ACCURATE MATCH EVERY TIME

AVANTEON. Operative Technique & Catalogue Information AVANTEON

Zimmer Segmental System

DOWNLOAD OR READ : TECHNIQUES IN REVISION HIP AND KNEE ARTHROPLASTY PDF EBOOK EPUB MOBI

RESTORATION MODULAR. Surgical Technique REVISION HIP SYSTEM

RECLAIM REVISION SOLUTIONS

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

Transcription:

PROFEMUR Total Hip System P R O D U C T C A T A L O G

The PROFEMUR Total Hip System Superior Product Modular Neck Technology Seat stem in best possible bone stock Control leg length, offset, and version Multiple Stem Options PROFEMUR Plasma Z PROFEMUR Z PROFEMUR T PROFEMUR RENAISSANCE PROFEMUR R PROFEMUR RAZ PROFEMUR LX PROFEMUR X m PROFEMUR TL Ease of Use Multiple Broach-Only Techniques PROFEMUR Plasma Z PROFEMUR Z PROFEMUR TL PROFEMUR RAZ PROFEMUR X m Modular Neck Technology Intraoperative flexibility Tissue-Preserving Implants Streamlined implants for tissue sparing insertion Modular Necks - Optimal Restoration of Normal Hip Biomechanics Leg length Varus, Valgus Anteversion, Retroversion PROFEMUR Total Hip System

PROFEMUR Total Hip Modular Neck System 4 / 8 / 15 Anteversion or Retroversion Technology You Can Trust Over 80,000 modular necks implanted worldwide since 1985. 1 And Use Avoid impingement Improved ROM results in decreased dislocation Independently adjust leg length and offset Correct minor variations in cup position without changing stem version Minimize incision and soft tissue trauma 6 / 8 / 15 Varus or Valgus 1. Data on file at Wright. Utilize PROFEMUR Modular Necks with Wright s DYNASTY Acetabular Cup System and ConservE Total Hip System. PROFEMUR Total Hip Modular Neck System

PROFEMUR Z / Plasma Z s Abbreviated Technique: Broach-only Sequentially broach for optimal fit Implant size corresponding to broach size Driving Platform Dimpled driving platform for stem insertion Templates PRFZ-XR15 Surgical Technique MH 004-104 Instruments Implants 4251-KIT1 PRZS-KIT2 (In-line Broaches) 4251-KITA (Z) 4251-KITB (Plasma Z) 3251-KITN (Mod. Necks) Rectangular Cross-Section Provides rotational stability and conserves bone for increased vascularization Trochanteric Wing Increased trochanteric wing contributes to proximal fill and rotational stability Dual Taper Geometry Provides optimal primary fixation and load transfer Plasma Z Plasma Spray Provides additional.5mm press-fit (.25mm per side) for initial stability and longterm ingrowth Heavy grit blast texture (6Ra µm) of titanium stem promotes bone ongrowth and implant stability Heavy grit blast texture (6Ra µm) of titanium stem promotes bone ongrowth and implant stability Available in sizes 1-9 Rounded Distal Tip Reduces the potential for thigh pain Rounded Distal Tip Reduces the potential for thigh pain PROFEMUR Z / Plasma Z s

PROFEMUR T Proximal Loading Stem: Maintains physiologic stress on the proximal femur Reduces stress shielding Provides axial and rotational stability Self-stabilizing geometry Driving Platform Threaded driving platform for rotational and axial implant control during insertion Lateral Shoulder Rounded lateral shoulder eases stem insertion and minimizes risk of fracture Abbreviated Technique: Ream and Broach Ream to templated size or cortical chatter Broach to corresponding reamer size Implant size corresponding to broach size Proximal Taper 3 proximal anterior/lateral/posterior taper improves proximal fill Plasma Spray Provides additional.5mm pressfit (.25mm per side) for initial stability and long-term ingrowth Templates PRFT-XR15 Surgical Technique MH 137-604 Instruments Implants PRGI-KIT1 (General) PRTB-KIT1 (Reamers/Broaches) PTSB-KIT1 (Slotted Reamers/ Broaches) 6251-KITI (Stems) 3251-KITN (Modular Necks) Heavy grit blast texture (5Ra µm) of titanium stem promotes bone ongrowth and implant stability Anti-Rotation Splines Provides additional 1.5mm press-fit (.75mm per side) for rotational and torsional stability. Available in 9-18 Narrow Distal Taper Bullet-shaped, polished tip reduces potential for thigh pain and minimizes reaming PROFEMUR T

PROFEMUR Renaissance Abbreviated Technique: Ream and Broach Ream to templated size Sequentially broach with reduced flare broaches to corresponding reamer size If fit is not secure, switch to standard flare broach or ream and broach to larger stem size Implant size and flare corresponding to broach size and flare Templates PLS0-XR15 Surgical Technique MH 143-405 Instruments Implants PRGI-KIT1 (General) PLRE-KIT1 (Reamers) PLBR-KIT1 (Broaches) PLIM-KITA (Stems) 3251-KITN (Modular Necks) Proximal Taper 3 proximal anterior/ lateral/posterior taper improves proximal fill Flare Standard and Reduced flare options ensure metaphyseal fit Driving Platform Threaded driving platform for rotational and axial implant control during insertion Lateral Shoulder Rounded lateral shoulder eases stem insertion and minimizes risk of fracture Light grit blast texture of titanium stem promotes bone ongrowth and implant stability Distal Splines Provide additional 1mm press-fit (.5mm per side) for rotational stability Distal Slot Reduces potential for thigh pain and risk of fracture during stem insertion Available in Reduced Flare, 10-16 and Standard Flare, 10-18 CaSO4-coated PROFEMUR RENAISSANCE Stem also available Distal Bullet Tip Round distal tip reduces stress between implant and bone, decreasing potential for thigh pain and risk of fracture during stem insertion PROFEMUR Renaissance

PROFEMUR RAZ Abbreviated Technique: Broach-only Sequentially broach for optimal fit Implant size corresponding to broach size Driving Platform Threaded driving platform for rotational and axial implant control during insertion Templates PYRD-XR15 Surgical Technique MH 281-905 Instruments Implants PRGI-KIT1 (General) PYRD-KIT1 (Broaches) PYRD-KITA (Stems) 3251-KITN (Mod. Necks) Rectangular Cross-Section Provides rotational stability and conserves bone for increased vascularization Dual Taper Geometry Provides optimal primary fixation and load transfer Trochanteric Wing Increased trochanteric wing contributes to proximal fill and rotational stability Heavy grit blast texture (6Ra mm) of titanium stem promotes bone ongrowth and implant stability Lateral View Available in 1-9 Proximal A/P Surface Increased material contributes to proximal fill and rotational stability Rounded Distal Tip Reduces the potential for thigh pain PROFEMUR RAZ

PROFEMUR TL Abbreviated Technique: Broach-only Sequentially broach for optimal fit Implant size corresponding to broach size Driving Platform Dimpled driving platform for stem insertion Templates PRTL-XR15 Surgical Technique MH 271-906 Instruments Implants PRGI-KIT1 (General) PRTL-KIT2 (Broaches) PRTL-KITA (Stems) 3251-KITN (Mod. Necks) Lateral Shoulder Reduced material helps to conserve bone and ease insertion Plasma Spray Provides additional.5mm pressfit (.25mm per side) for initial stability and long-term ingrowth Flat Tapered Wedge Geometry Provides firm mediolateral stability within the femoral canal Slim A/P Dimension Conserves bone while providing excellent torsional stability Light grit blast texture of titanium stem promotes bone ongrowth and implant stability Available in 1-12 PROFEMUR TL

PROFEMUR LX Abbreviated Technique: Ream and Broach Ream to templated size or cortical chatter Broach to corresponding reamer size Implant size corresponding to broach size Driving Platform Threaded driving platform for rotational and axial implant control during insertion Templates PLX0-XR15 Surgical Technique MH 282-905 Instruments Implants PRGI-KIT1 (General) PRLX-KIT1 (Broaches) PRLX-KIT2 (Reamers) PRLX-KITA (Stems) 3251-KITN (Mod. Necks) Plasma Spray Provides additional.5mm press-fit (.25mm per side) for initial stability and long-term ongrowth Heavy grit blast texture (8Ra µm) of titanium stem promotes bone ongrowth and implant stability Lateral View Available in 11-19 Lateral Shoulder Rounded lateral shoulder eases stem insertion and minimizes risk of fracture Proximal Taper 3 proximal anterior/ lateral/posterior taper improves proximal fill Distal Splines Provide additional 0.25mm press-fit for rotational stability Distal Slot Reduces potential for thigh pain and risk of fracture during stem insertion Distal Bullet Tip Round distal tip reduces stress between implant and bone, decreasing potential for thigh pain and risk of fracture during stem insertion PROFEMUR LX

PROFEMUR X m Abbreviated Technique: Broach-only Sequentially broach for optimal fit Implant size corresponding to broach size (Broach prepares for 2mm circumferential cement mantle) Templates PRXM-XR15 Surgical Technique MH 260-906 Instruments PXTR-KIT1 (Broaches) 4251-KIT1 (General) Implants PHA0-6000 (Sz. 0) PHA0-6002 (Sz. 1) PHA0-6004 (Sz. 2) PHA0-6006 (Sz. 3) PHA0-6008 (Sz. 4) 3251-KITN (Mod. Necks) Dual Taper Geometry Promotes cement engagement and provides rotational stability Surface Highly polished, forged CoCr stem reduces friction at the cement-implant interface, reducing the potential for wear Rounded Edges Promotes radial compressive loading Available in sizes 0-4 Distal Centralizers Allow distal stem engagement within the cement mantle PROFEMUR X m

Neck Options Short Straight Long Straight Valgus Short Varus Short Valgus Long Varus Long Short Straight Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset +7.5 +7.5 +3-2 -2 +3 +11 +4 +4 +11 Long Straight Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset -7.5-7.5-4.5-9.5-9.5-4.5 +4-3 -3 +4 Valgus Short Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset -3 +2 +4.5 +9.5-5 +5 +8.5 +6.5 +1.5 +13.5 Varus Short Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset +2-3 +9.5 +4.5 +5-5 +13.5 +1.5 +6.5 +8.5 Valgus Long Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset -11.5-4 -4 +3-8.5-6.5-13.5-1.5-7 +7 Varus Long Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset Leg Length Offset -4-11.5 +3-4 -1.5-13.5-6.5-8.5 +7-7 Chart Rules: 1. Changing from a neutral neck to an anteverted/retroverted neck does not significantly change leg length or offset (as long as neck length stays the same). a.treat A/R 8 and A/R 15 necks just like straight necks. b.treat ARVV1 and ARVV2 necks just like varus or valgus necks, depending upon hip* 2. A change in femoral head neck length, increases or decreases both leg length and offset by 2.5mm (assuming no neck change). a. Going from a Medium head to a Long head, increases both leg length and offset by 2.5mm. b. Going from a Medium head to a Xtra Long head, increases both leg length and offset by 5mm. c. Going from a Medium head to a Xtra-Xtra Long head, increases both leg length and offset by 7.5mm. d. Going from a Medium head to a Short head, decreases both leg length and offset by 2.5mm. * Left Hip * Right Hip ARVV1 ARVV2 ARVV1 ARVV2 Anteverted/Valgus Retroverted/Varus Anteverted/Varus Retroverted/Valgus Anteverted/Varus Retroverted/Valgus Anteverted/Valgus Retroverted/Varus * Modular neck chart should be used to approximate changes in leg length and offset. Ultimately, final neck selection should be based on intraoperative evaluation of joint stability during trial reduction. www.wmt.com Current Neck

Additional Products To Preserve Tissue, Use PATH Tissue-Preserving Total Hip Arthroplasty PATH - KIT3 PHRM KIT1 PBFH KIT1 PATH General instruments PATH Reamer baskets PATH BFH Suction Impactor and Alignment Handles PATH (Percutaneous Assisted Total Hip Arthroplasty) Minimally Invasive Total Hip Arthroplasty S U R G I C A L T E C H N I Q U E MH039-105 PATH Surgical Technique MH313-1006 PATH Surgical Animation DVD Wright Medical Technology, Inc. 5677 Airline Road Arlington, TN 38002 901.867.9971 phone 800.238.7188 toll-free www.wmt.com Wright Medical Europe, SA Commerce Parc Gebouw B, 6th Floor Krijgsman II 1186 DM Amsterdam The Netherlands Tel +31(0) 205450100 Trademarks and Registered marks of Wright Medical Technology, Inc. Covered by one or more of the following US Patents: 4,957,510. Patents pending. 2006 Wright Medical Technology, Inc. All Rights Reserved. MH 100-305 Rev. 11.07